Project Description
Tender for Periodical Services To Md And Otm Accn At Darjipura At Afs Baroda.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Aug-2026 | OTHER | Other | 21-Aug-2026 |
| 2 | 21-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for prepration of the old decorated surfaces of wall by wire brushing and scraping and appling one coat of cement base paint, etc. complete all as specified and directed. |
| 2 | M&L for preparation of old decorated surfaces of wall rubbing down and applying one coats of Exterior acrylic Emulsion paint over a coat of primer, complete all as specified and directed. |
| 3 | Complete removal of existing treatment of old decorated surfaces of wall, plastered or unplastered including cornices pilasters by brooming down or steel wire brushing, scraping down, smoke shoot, moulds, mors and efforescent salts and treating oil and greasy spots and applying Two coats of Exterior acrylic Emulsion over one coat of primer complete all as specified and directed. |
| 4 | M&L for preparation of old decorated surfaces of wall rubbing down and applying one coat of oil bound distemper (any tint shade) all as specified and as directed by Engineer -in-Charge. |
| 5 | M&L preparation of old surfaces of wall / ceiling and applying 1-1.5mm thick of JK/Birla Cement putti finished complete all as specified and directed. |
| 6 | Complete removal of existing treatment of old decorated surfaces plastered or unplastered on walls including cornices pilasters by brooming down or steel wire brushing, scraping down, smoke shoot, moulds, mors and efforescent salts and treating oil and greasy spots and applying Two coat of oil emulsion distemper over one coat of primer, complete all as specified and directed. |
| 7 | M&L for preparation of old decorated surfaces of wall rubbing down and applying One coat of white wash on walls, complete all as specified and directed. |
| 8 | M&L for preparation of old decorated surfaces of ceiling, rubbing down and applying One coat of white wash, complete all as specified and directed. |
| 9 | Preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 10 | Preparation of old painted surfaces of steel and iron surfaces over 10cm width or grith and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 11 | Cutting down Vegetation growths like plants/trees of girth n.exc 15cm from roof tops/sides, external walls of bldgs, Chajjas, wall junctions at junctions of rain water/ CI waste water pipe junctions including removal of roots and taking out carefully possible quantity of concrete in roofs embedded in walls/slab surfaces including repairing the GI/ CI/ PVC pipe joints of that affected locations and applying TUFALO chemical (herbal rnedicine) to arrest further growth and making good the distrubed surfaces with PCC (1:2:4) type B-1 or CM 1:2 or brick work in CM 1:4 and plastering with CM 1:4 and treating tthe surfaces to match with the adjoining surfaces all as specified and directed by the Engr-in-Charge.Note :-(i) The unit rate quoted shall be deemed to include the cost of scafolding/staging etc.(ii) Any CI/AC/PVC special damaged during work shall be replaced by new one to ensure leak/seapage free joint unit rate quoted shall deemed to be include cost of replacement of specials. |
| 12 | M&L for writing letter or figures (block, roman, Italic or Indian) n.exc. 30 cm high on building with synthetic enamel paint, complete all as specified and directed. |
| 13 | M&L filling surface cracks not exc 5 mm to 7 mm wide with \\"Dr fixit\\" cracks X power or equivalent polymer molified cracks filler all as per manufacturer instructions, complete all as specified and directed. |
| 14 | Taking dawn cement plaster any description on brick or stone wall/ celling including raking out joint , haking for key scrubing with water etc, complete all as specified and directed. |
| 15 | M&L for 15 mm thick rendering in CM 1:6 and finishing using water proofing compound on faces of brick masonary wall, finished even and fair etc, complete all as specified and directed. |
| 16 | M&L for 10 mm thick rendering in CM 1:4 on concrete surfaces / fair faces of brick masonary wall, finished even and smooth with thin layer of sagol, complete all as specified and directed. |
| 17 | Supply only intergral water proofing compound. |
| 18 | M&L for preparation of new surfaces of wall and applying two coat of oil bound distemper all as specified (any tint shade as approved by GE) as directed by Engineer -in-Charge. |
| 19 | M&L Preparation of New plastered Surface of wall and application of two coats of Exterior Emulsion Paint over one Coat Primer complete all as specified and directed. |
| 20 | Dismantling / taking up of CI/PVC or reinforced concrete drain pipes 75/100mm internal dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 21 | S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 22 | S&F in repair 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 23 | S&F 110 mm dia PVC (SWR) bends any length any type, complete all as specified and directed. |
| 24 | S&F 75 mm dia PVC (SWR) bends any length any type, complete all as specified and directed. |
| 25 | S&F 110mm PVC (SWR) branch piece double (double Y) equal or unequl, complete all as specified and directed. |
| 26 | S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed. |
| 27 | S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed. |
| 28 | S&F 110mm PVC (SWR) branch piece double (Single Y) equal or unequl, complete all as specified and directed. |
| 29 | S&F 75mm PVC (SWR) branch piece double (Single Y) equal or unequl, complete all as specified and directed. |
| 30 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 31 | S & F stack clamp made of 50 mm X 5 mm flat iron and 16 mm dia round iron stay including nut bolts and securing ends of stay to wall or roof suitable for 100 mm bore pipe complete all as specified and directed. |
| 32 | M&L for Preperation of old painted surface of Pipes and Eaves gutter any description, n. exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc. and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 33 | Cutting around pipe 100mm bore and open the lekage joint and repair with cement morter 1:1 with water proofing compound and making good the surface with CM 1:3 and touch with cement base paint(externally from first floor to third floor complete all as specified and directed. |
| 34 | Note for all items :- If any item gets repeated in this schedule, the lowest rate quoted for those same items by the L-1 bidder shall be considered for payment and decision of Accepting Officer i.e. GE(AF) Baroda in this regard shall be final and binding. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender