Tender For Modernization/Upgradation Of Existing Parks/Green Belts.Sub Head :- Supply Installation Testing and Commissioning of 4 Kwp Off Grid Solar Power Plant And Internal Electrical Works For Site Office Of Yamuna Vanasthali. Estimated Cost :- ₹ 7
Tender Overview
Project Description
Tender for Modernization/Upgradation Of Existing Parks/Green Belts.Sub Head :- Supply Installation Testing and Commissioning of 4 Kwp Off Grid Solar Power Plant And Internal Electrical Works For Site Office Of Yamuna Vanasthali. Estimated Cost :- ₹ 7,89,356.00
BOQ
| Sl. No. | Item Description |
| 1 | Supplying Installation, Testing and Commissioning of Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of N-Type TOPC on Solar module, necessary control, protections, earthing, cabling, Aluminium/GI mounting structure, junction boxes, Distribution panels, conduits, pipes, cable trays and other accessories etc. as required. High Energy Efficiency Solar Photovoltaic Module of capacity 590 Wp or above havingModule conversion efficiency not less than 23% at STC with temperature coefficient of Pmax better than -0.30% per deg.C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Fixing of Array junction box & Main junction box with IP65protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.Lightning and surge voltage protection.Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. |
| 2 | SITC of 200 AH( 4 Nos , 48 V) battery suitable for min. 6 hrs. battery backup duly for (Night times) complete with solar Inverter (48V/5 KVA ) with MPPT controller and having required protection. Battery & Inverter set up shall be installed on a suitable size MS angle frame and covered with suitable size Tin housing complete with door for protection against rain and theft etc. as reqd. |
| 3 | Supplying of following sizes of XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part-I) i/c connection & testing etc. complete as required. |
| 4 | 4C x 16 Sq.mm |
| 5 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC pipe / pole as required. |
| 6 | Up to 35 Sq.mm |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 8 | 4x16 sq.mm (28 mm) |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 12 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 13 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.. Group A |
| 14 | Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modularswitches in recess etc. as required. |
| 17 | 3 Module (100mmX75mm) |
| 18 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. |
| 19 | 3 pin 5/6 A socket outlet |
| 20 | 15/16 A switch |
| 21 | 6 pin 15/16 A socket outlet |
| 22 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 23 | Single pole |
| 24 | Double pole |
| 25 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 18- 22 Watt |
| 26 | Earthing with G.I. Earth Pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 27 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for conneciton etc. as required. |
| 28 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia GI pipe from earth electrode including connection with GI nut bolt , spring washer, excavation, refilling etc. as required. |
| 29 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface /recessed conduit submain wiring /cable as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender