Public Administrative Department Local Bodies Closing in 9 days TDR #56769127

Tender For Provision Of Temporary Electric Lighting For Municipal Council Dharashiv On A Contract Basis, Electrification Of Municipal Administrative Buildings, Schools, Etc., Road Lighting Repair, Transformer Repair Work In Water Supply Department An

Issued by Local Bodies · Osmanabad, Maharashtra
Tender Value
30 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
9 days left
EMD
30000
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Osmanabad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Temporary Electric Lighting For Municipal Council Dharashiv On A Contract Basis, Electrification Of Municipal Administrative Buildings, Schools, Etc., Road Lighting Repair, Transformer Repair Work In Water Supply Department And Other Ancillary Electrical Works.

BOQ

Name of Work:- नगरपरिषद धाराशिव करिता दर करार पद्धतीने तात्पुरती विद्युत रोषणाई करणे, नगरपरिषदेच्या प्रशासकीय इमारती, शाळा, इत्यादी ठिकाणी विद्युतीकरण करणे, पथदिवे दुरुस्ती विषयक, पाणीपुरवठा विभागातील ट्रान्सफॉर्मर दुरुस्ती विषयक कामे करणे व इतर अनुषंगिक विद्युत कामे करणे.
Sl. No. Item Description
1Temporary Electrification, CCTV Etc.
2Providing temporary illumination consisting of LED flood light fitting 100w, having colour temp up to 6500k, IP65, housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete erected with mains, switchgears with continuous earth wire erected and dismantled with using scaffolding up to three days
3Providing temporary illumination consisting of flood light fitting 200 W complete LED fitting having colour temp up to 6500k, IP65, housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete required switchgear erected and dismantled with using scaffolding up to three days.
4Providing temporary illumination consisting of flood light fitting 300 W complete LED fitting having colour temp up to 6500k, IP65, housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete required switchgear erected and dismantled with using scaffolding up to three days.
5Providing temporary illumination consisting of white/colour series lights with 8mm LED miniature lamps of 2 to 3.4V [1000nos] with cap with required switchgears erected and dismantled with rotor effect as approved without scaffolding up to three days.
6Providing temporary illumination consisting of white/colour series lights with 8mm LED miniature lamps of 2 to 3.4V [1000nos] with cap with required switchgears erected and dismantled with rotor effect as approved with scaffolding up to three days.
7Providing temporary illumination consisting of water proof LED Par Light, 54 pieces x 3W, 230v, 50Hz, with RGBW controller complete erected with mains, switchgears with continuous earth wire erected and dismantled without using scaffolding up to three days
8Providing temporary illumination consisting of water proof LED Par Light, 54 pieces x 3W, 230v, 50Hz, with RGBW controller complete erected with mains, switchgears with continuous earth wire erected and dismantled with using scaffolding up to three days
9Providing temporary illumination consisting of water proof HMI Par Light, 4000 w, 230v, 50Hz, colour temp 6500k housing of pressure die cast aluminium alloy [multi colour] complete erected with mains, switchgears with continuous earth wire erected and dismantled without using scaffolding up to three days
10Providing temporary illumination consisting of water proof HMI Par Light, 4000 w, 230v, 50Hz, colour temp 6500k housing of pressure die cast aluminium alloy[multi colour] complete erected with mains, switchgears with continuous earth wire erected and dismantled with using scaffolding up to three days
11Providing temporary XLPE/PVC armoured cable 4 core 50 sq mm Aluminium conductor with continuous 12 SWG G.I. Earth wire complete erected with gland and lugs and switchgears and required cable protector wherever necessary up to three days
12Providing temporary XLPE/PVC armoured cable 4 core 95 sq mm Aluminium conductor with continuous 10 SWG G.I. Earth wire complete erected with gland and lugs and switchgears and required cable protector wherever necessary up to three days
13Providing temporary digital projector having Full HD 1080p resolution with White and Colour Brightness at range of 3000-4000lm,HDMI port, USB port, AV port, computer port with spring loaded white screen connected with necessary mains, required switchgears and maintaining the same during the function including dismantling.
14Providing, maintaining and operating temporary public address system on hire consisting 02 Nos. solid state heavy wattage amplifier 250 watts ( one for working and another for stand by emergency ) working on AC / generator and 24 volt car battery supply, 06 Nos. of matching of 100 volt line (200 watts) box type speakers/sound column, 02 Nos super sensitive microphone with suitable size of microphone holding stand. The system shall be in
15Providing, maintaining and operating temporary dual PA UHF wireless microphone on hire consisting 01 Nos. receiver having S/N ratio 100dB, frequency response 50-15000Hz, controls like ON/OFF Switch, Volume control and 02 Nos. of handheld wireless transmitter with new AA batteries having ON/OFF Switch, channel frequency display, carrier frequency range 630-664MHz for one day.
16Providing and maintaining temporary cordless ( Hand type or lapel type ) super sensitive UHF microphone (1 no stand by) for one day.
17Providing, commissioning and maintaining temporary CCTV system with 8 channel NVR, IP video/audio input - 1 no, IP based 4.0 MP, Full HD, IR IP dome camera - 2 nos, IP based 4.0 MP, Full HD, IR IP PTZ camera - 2 nos, 4TB Hard Disk - 2 no, 42'' Full H D professional display - 1 no, 8 port PoE Switch - 1 no, Power supply unit to camera - 1 no, On Line UPS - 1 no with necessary mains, switchgears on hire basis for one day
18Providing, commissioning and maintaining additional IP based 4.0 MP, Full HD, IP67, IR IP PTZ camera in existing CCTV system with necessary mains, switchgears on hire basis for one day.
19Hiring charges for supplying and maintaining 230/415 V, 50 cycles AC generating set 3 to 10 kVA capacity with necessary fuel, mains, switchgears and accessories complete with continuous running on load/no load as per requirements complete with self certification.
20मंडप (10 x 10 ) ( बांबु पद्धत)
21बॅरागेटींग 5 फुट ऊंच विना कव्हर
22बॅरागेटींग 5 फुट ऊंच मंडप/पत्रा कव्हर
23मंडप (10 x 10 ) ( जी. आय. पाईप पद्धत)
24मेघडंबरी मंडप (डॉ. बाबासाहेब आंबेडकर पुतळा अच्छादन करिता/ छ. शिवाजी महाराज पुतळा अच्छादन)
25Office, Admin Building, Schools electrification, street light repair, flood light for water pump house, generator repair, AC Repair EtcSupplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
26Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
27Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
28Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
29Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.
30Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire
31Supplying and erecting mains with WP 4 x 4 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire
32Supplying and erecting mains with WP 4 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire
33Supplying and erecting mains with WP 3 x 4 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire
34Supplying and erecting mains with WP 3 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire
35Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
36Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
37Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections
38Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
39Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected
40Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
41Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected
42Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected.
43Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected
44Supplying and erecting 16 to 32 A, 10kA, DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected.
45Supplying and erecting PVC Surface modular double mounting plate 1 module complete duly erected.
46Supplying and erecting PVC Surface modular double mounting plate 2 module complete duly erected.
47Supplying and erecting PVC Surface modular double mounting plate 6 module complete duly erected.
48Supplying and erecting PVC Surface modular double mounting plate 12 module complete duly erected.
49Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
50Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
51Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
52Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete
53Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete
54Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50 including driver with 1 year warranty.
55Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
56Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/ 1200x300mm and finishing the background to match the original ceiling surface.
57Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection
58Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 x 20W UV Tube Lights to cover min. area of 500 sq.ft with powdered coated M.S./ steel body suitable to work on 230V, AC Supply having top mounting arrangement with SS chain complete and 3 core 1 mtr. flexible wire with 1 year warranty.
59Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply.
60Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
61Supplying and erecting regular/ standard model ceiling fan of 600mm. Sweep complete erected in position as per specification no. FG-FN/CF
62Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF
63Supplying and erecting regular/ standard model ceiling fan of 1400mm. Sweep complete erected in position as per specification no. FG-FN/CF
64Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc.
65Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
66Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
67Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paintand two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
68Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
69Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
70Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC
71Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
72Electrician
73Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
74Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
75Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
76Supplying and erecting 12V/180Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
77Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
78Providing annual comprehensive maintenance contract for 1.5TRsplit/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material.
79Providing annual comprehensive maintenance contract for 2TRsplit/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material.
80Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1.5TR by new one of same capacity with guarantee for one year with provided refrigerant complete
81Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2TR by new one of same capacity with guarantee for one year with provided refrigerant complete.
82Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2.5TR to 4.5TR by new one of same capacity with guarantee for one year with provided refrigerant complete.
83Providing flushing out cooling coil and condenser coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure, complete
84Providing replacement of unserviceable starting relay for AC unit
85Providing replacement of unserviceable starting capacitor for AC unit
86Providing replacement of unserviceable running capacitor for AC unit.
87Providing replacement of unserviceable PCB for AC unit upto 3TR capacity
88Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit.
89Providing replacement of existing unserviceable condenser coil of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant
90Providing replacement of existing unserviceable compressor of 150 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year.
91Supplying and erecting candle filter with filter pot for water cooler
92Providing replacement of base tray of water cooler of any capacity
93Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 200A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6
94Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
95Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
96Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
97Supplying and erecting porcelain base iron clad cut out HC type 415V, 100A erected on polished wooden block
98Supplying and erecting porcelain base iron clad cut out HC type 415V, 200A erected on polished wooden block.
99Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
100Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
101Supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
102Supplying and erecting 50 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
103Supplying and erecting 100 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
104Supplying and erecting 250 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
105Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 400 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
106Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
107Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
108Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
109Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
110Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification No. CB-JT/LT
111Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 300 sq mm., with necessary material as per specification No. CB-JT/LT
112Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 400 sq mm., with necessary material as per specification No. CB-JT/LT
113Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
114Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
115Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x400 sq. mm. with necessary material as per specification no. CB-JT/HT
116Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
117Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x400 sq. mm. with necessary material as per specification no. CB-JT/HT
118Supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm for XLPE armoured cable as per specification No. CB-GL
119Supplying & erecting single compression type brass cable glands for 3½core 300 sq mm for XLPE armoured cable as per specification No. CB-GL
120Supplying & erecting single compression type brass cable glands for 3½core 400 sq mm for XLPE armoured cable as per specification No. CB-GL
121Supplying & erecting crimping type copper lugs for cable 95 sq mm complete as per specification No. CB-CL/CU
122Supplying and erecting rolled steel joist (girder) pole 150 x 80 mm/150 x75 mm (14.9 kg /m) with base plate in provided foundation as per specification no. OH-PL/RSJ
123Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT
124Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from ISM channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT
125Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from ISM channel 75x40x6mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT
126Supplying and erecting V cross arm with ISM channel of 100x50x6mm or 22/33kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1530mm bent at angle of 60 degree keeping base 310mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA
127Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA
128Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing
129Supplying and erecting all aluminium stranded conductors 7/2.21 mm. complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC
130Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC
131Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR
132Supplying and erecting pin type LT medium insulator 100mmx 62mm dia. with suitable G.l. spindle, nut, bolts complete
133Supplying and erecting aluminium bobbin with G.l. (shackle) strip, nuts complete.
134Providing and fixing GI earthing stud with necessary materials
135Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI
136Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN
137Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA
138Supplying and erecting G.I. fly stay set for pole including straining screw, G.l. stay wire, 7/10 SWG (for to 15m long) with pole clamp, made of 50x6mm MS flat, erected on provided RSJ pole complete. (Add. Rs. 25/- per m for extra length beyond 15 m)
139Supplying and erecting guarding loop using G.l. wire no. 8SWG for LT OH line of horizontal formation erected with 20SWG G.l. wire as binding wire and 50mm section on each side complete.
140Supplying and erecting fibre/PVC spacers for LT overhead line 3 to 5 conductors complete erected.
141Supplying and erecting pole clamp made from 50x10mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete.
142Supplying and erecting ‘D’ type pole clamps, fabricated from 50x6mm MS flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint complete
143Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position
144Supplying and fixing MS round base plate 25cm dia and 10mm thick fixed to pole welded and fixed at position
145Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level
146Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes.
147Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
148Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
149Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 200 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.
150Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.
151Supplying and erecting 33 kV outdoor type gang operated air break, triple pole switch 200 A capacity with 3 post pin type insulator double stack per phase, mounted in horizontal position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp
152Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm
153Supplying and erecting, 33 kV outdoor type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm.
154Supplying and erecting 11 kV fuse barrel with metal fittings complete
155Supplying heavy duty operating rod, outer dia 25 mm & inner dia 20 mm suitable for 11 kV with brass couplings etc. for removing drop out fuses at 6 meters length, 4 pieces each with rain shade with hand grip including earthling chain 1.5m complete
156Supplying and erecting copper tubular bus 20 mm dia 1.6 mm (16 SWG) thick for the use of high tension over head bus and erected on provided HT insulators with clamps, nuts and bolts complete. (weight per meter of bus is about 1.7 kg.)
157Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of up to 10 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
158Carrying out Servicing of DG set up to 50 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minorleakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC
159Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR
160Making trench in Hard murum/Tar road having 0.75 m depth andminimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR
161Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
162Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)
163Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
164Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
165Rent for Crane
166Rent for Concrete breaker & Compressor
167Supply & replacement of stainless steel rope wire for all types of highmast
168Supply & replacement of pulley assembly for all types of highmast
169Supply & replacement of winch assembly for all types of highmast
170Supply & replacement of top pully for all types of highmast
171Supply & replacement of bottom pulley for all types of highmast
172Supply & replacement of pulley assembly for all types of highmast
173Supply & replacement of gear box for all types of highmast
174Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 25 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
175Providing & erecting epoxy straight through joint outdoor/indoor for LTXLPE armoured cable 25 to 50 sq mm., with necessary material as perspecification No. CB-JT/LT
176Supplying and erecting integrated LED street light fitting 26 to 30W IP65 &IK08 class having single piece pressure die-cast aluminium housing , havingsystem lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W,CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, includingdriver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
177Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W,CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, includingdriver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
178Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including
179Supplying and erecting integrated LED flood light fitting Max. 155W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
180Supplying and erecting integrated LED flood light fitting Max. 195W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with Ushaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
181Supplying and erecting four pole power contactor 430 V, 40 A for time switchcomplete erected on provided wooden block/ box, with necessary materials.
182Supply and erecting 9m (clear height) Fixed type high-mast (Top-100mm,Bottom- 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. OH-PL/OPL (excluding luminaires).
183Supplying and erecting outdoor stand mounted feeder pillar for high-mast ofthe same manufacturer with 32A TPN MCB incomer, 24hr astronomical timeswitch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TPcontactor for automatic switching of luminaires, 2 no. 9A contactors andraise/lower push button, and provision for termination of adequate size ofincoming and outgoing cables complete erected in min. 14 SWG CRCA sheet boxwith supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
184Supplying & erecting single phase, 240V, street light control panel up to themax load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ CC foundation.
185Supplying & erecting single phase, 240V, street light control panel up to themax load of 12kW, SPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.
186Supplying & erecting three phase, 415V, street light control panel up to themax load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56769127
AUTHORITY Local Bodies
TENDER VALUE 30 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Directorate Of Municipal Administration
Work Description Tender for Provision Of Temporary Electric Lighting For Municipal Council Dharashiv On A Contract Basis, Electrification Of Municipal Administrative Buildings, Schools, Etc., Road Lighting Repair, Transformer Repair Work In Water Supply Department And Other Ancillary Electrical Works.
Basic Detail
Tender No O.No/4073/2026,Dt.30/07/2026
Bidding Type Tender
Location
City Osmanabad
State Maharashtra
Key Dates
Publish Date 31 Jul 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 600
EMD 30000
Exemption Not Available
Document List
BOQ_2267083.xls
f4746d84-bb11-451b-a5c9-2fa191e6fe01.html
SchaduleAyearlytender.pdf
Tendernotice_1.pdf
YearlySLtender.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2267083.xls

html

f4746d84-bb11-451b-a5c9-2fa191e6fe01.html

pdf

SchaduleAyearlytender.pdf

pdf

Tendernotice_1.pdf

pdf

YearlySLtender.pdf

Disclaimer