Tender For maintenance of electrical installation & Fans I/C repair maintenance Pump Sets, Compound Lights, Air-Conditioning And Other E & M Services At Ncc Building B-6 Safdarjang Enclave I/C Pwd Offices, New Delhi Under Ae (E), Sub-Div-Iii, Pwd Emd
Tender Overview
Project Description
Tender for maintenance of electrical installation & Fans I/C repair maintenance Pump Sets, Compound Lights, Air-Conditioning And Other E & M Services At Ncc Building B-6 Safdarjang Enclave I/C Pwd Offices, New Delhi Under Ae (E), Sub-Div-Iii, Pwd Emd South West During 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Sub-Head-1(Maintenance of EI) |
| 2 | Maintenance and operation of Pumps, light points, fan points, exhaust fan point, call bell point, light plugs, power plugs, circuit wiring, street light and flood light i/c DBs main boards and other electrical installation in the building during the month including Sundays & Holidays by providing following staff and as per terms & conditions attached:Staffs: |
| 3 | Wireman cum Pump Operator - 3 Nos. (Round the clock) |
| 4 | Khallasi- 1 No. (General Shift) |
| 5 | Sub-Head-II (Maintenance of AC ) |
| 6 | Comprehensive & Routine maintenance of 24 Nos. WTAC / STAC unit i/c attending day to day complaints and rectify the defects, supplying and replacement of wornout parts such as starting / running capacitors, starting relays, overload relay, tharmostat, selector switches, sleeves, knobes, connector and associated control wiring, filter, drain pipe etc which reqd to be replace during routine maintenance and monthly cleaning of filters etc. (Replacement of compressor, condensor unit, cooling coil unit, blower, fan blower motor, front grill, man leads, gas charging etc not covered under routine maintenance) complete as per terms & conditons. |
| 7 | Servicing of existing installed WTAC / STAC of 1.5 TR & 2.0 TR capacity AC and water coolers of 80/150/250 LPH, checking for unit, inspection, greasing, oiling etc i/c chemical cleaning of the condensing coil with high pressure pump changing the air filter, checking & tightening all electic connection, testing the machine etc as reqd. |
| 8 | Dismantling & Re-installation of exisiting installed STAC / WTAC of 1.5 TR & 2.0 TR capacity with outdoor unit from its location to another location, unloading for reinstallation checking for unit, inspection and reconnection of drainage pipe, reconnection and tightening the loose connection, testing the machine etc as reqd. |
| 9 | Supplying & charging of M-22 / R-22 gas in the exising WTAC / STAC of 1.5TR unit i/c pressure testing, flushing the system & gas charging complete etc |
| 10 | Supplying & charging of M-22 / R-22 gas in the exising WTAC / STAC of 2 TR unit i/c pressure testing, flushing the system & gas charging complete etc as reqd. |
| 11 | Supplying & fixing of 25 mm dia PVC heavy duty pipe drainage in the existing split type AC unit with supporting clamps etc complete as reqd |
| 12 | Repair of damaged PCB of indoor and outdoor unit i/c tightening the loose connection, testing the machine etc as |
| 13 | Supplying & fixing of copper refrigerant pipe of size 1/4\\", 5/8\\" with insulation and copper wire 3 core 80-20 i/c all connection in the existing AC units etc. as per reqd at site. |
| 14 | SH- III (Supply of material) |
| 15 | Following material /electrical accessories shall be supply by agency and fixing will be done by the existing man power for replacement on day to day maintenance works etc as required. (Labour already included in Item No. 1 o Sub Head - I : EI & FANS ) |
| 16 | 5 Amp Modular Switch |
| 17 | 5 Amp Modular Socket |
| 18 | 15/16 Amp Modular Switch |
| 19 | 15/16 Amp Modular Socket |
| 20 | S.P. 5/6 A, one way switch, piano type ISI marked |
| 21 | 3 pin 5/6 A socket outlet, piano type ISI marked |
| 22 | 3 mm thick phenolic laminated sheet |
| 23 | 6 to 32 Amp c Curve SP MCB, \\"C\\" curve, 10 kA breaking capacity |
| 24 | 6 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity |
| 25 | 6 amps. to 32 amps. ratings , SPN MCB, “C” curve, 10 KA breaking capacity |
| 26 | 6 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity |
| 27 | 6 amps. to 32 amps. ratings , TPN MCB, “C” curve, 10 KA breaking capacity |
| 28 | 40 amps., 2 pole isolator |
| 29 | 63 amps., 2 pole isolator |
| 30 | 40 amps., 4 pole isolator |
| 31 | 63 amps., 4 pole isolator |
| 32 | 100 amps., 4 pole isolator |
| 33 | 1.5 sq.mm FRLS PVC insulated copper conductor single core wire |
| 34 | 4 Sq.mm sq.mm FRLS PVC insulated copper conductor single core wire |
| 35 | 6 Sq.mm sq.mm FRLS PVC insulated copper conductor single core wire |
| 36 | 2.50 mfd fan capacitor |
| 37 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 38 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 39 | 300 mm sweep heavy duty exhaust fans |
| 40 | 400 mm Wall Fan Oscillating type |
| 41 | 380 mm sweep heavy duty exhaust fans |
| 42 | 250 mm sweep PVC Air Ventilation fans |
| 43 | Stepped type Modular Fan regulator (2 module) |
| 44 | Modular bell push, ISI marked |
| 45 | Modular base & cover plate for 3 module |
| 46 | Modular base & cover plate for 6 module |
| 47 | Modular base & cover plate for 8 module |
| 48 | Modular base & cover plate for 12 module |
| 49 | 3 pole MCCB, 100A, 16kA |
| 50 | 3 pole MCCB, 125A, 16kA |
| 51 | 3 pole MCCB, 150A, 16kA |
| 52 | 20 mm diA, ISI marked, steel conduit |
| 53 | 25 mm diA, ISI marked, steel conduit |
| 54 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 55 | 3 x 1.5 sq. mm |
| 56 | 3 x 4 sq. mm |
| 57 | 3 x 6 sq. mm |
| 58 | Supply of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor m single core cable and earthing etc. as required with Minimum 5 year OEM mwarranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by mEngineer-in-Charge as per requirement. (Thermal management: heat sink nof aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness > 0.50 mm) |
| 59 | 36 watt |
| 60 | Supply of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness > 0.50 mm) |
| 61 | 36 watt |
| 62 | Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium armoured cable of following size on wall surface as required. |
| 63 | 3 x 10 sqmm |
| 64 | 3.5 x 50 sqmm |
| 65 | SH- IV( Pump) |
| 66 | Lowering of 3/5/7.5/10 H.P. Submersible/ Monosubmersible pump sets in the underground tank or Borewell along with existing GI Pipe submersible cable etc. With the help of tri-port and chain pully block including P/F nub bolts, rubber packing, including testing, commissioning etc as required. |
| 67 | Submersible pump set. |
| 68 | Lifting of 3/5/7.5/10 H.P. Submersible/ Monosubmersible pump/sets from the underground tank or Borewell with the help of tri-port and chain pully block along with existing GI pipe and submersible cable etc complete as required. |
| 69 | Submersible pump set. |
| 70 | Rewinding of 5 HP Submersible pump sets of following rating including cutting the burnt winding wire including rewinding the same with high quality motor resistance PVC Insulated copper winding the wire and rematling of shaft and turning & polishing of rotor sleeve i/c testing & commissioning complete etc. as reqd. |
| 71 | 5 HP |
| 72 | Providing and fixing of following 7.5/5 HP Submersible spare parts in the above motor i/c credit of old dismantled material etc as reqd. |
| 73 | Rematling of shaft and Turning & Polishing of Rotor sleeve- 1 job |
| 74 | G.M. Bush - 4 Nos. |
| 75 | PVCImpeller and duffuser with Neck ring & distance bush - 10 Nos. |
| 76 | Oil/Water Seal- 2 Nos. |
| 77 | Flat Cable 3X2.5 Sq.mm- 5 Mtr. |
| 78 | Thrust plate and Thrust Bearing- 1Set |
| 79 | Supplying, installation, testing & commission of Submersible pump set of following capacity suitable for working on 3 phase,415 volts A.C. supply 50 Hz i/c lowering in the sump well with the help of chain pulley block and tripod stand, connecting with existing delivering pipe lines, connections 5 HP i/c connection etc as required. |
| 80 | Head 10-380 mtrs., Discharge 15-66 LPM, Bore size 100mm, outlet size- 32 mm |
| 81 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 82 | 50mm dia |
| 83 | Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal gate valve (Screwed type) on the existing pipeline, including testing & Commissioning etc. complete as required.. |
| 84 | 50 mm dia |
| 85 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. |
| 86 | 50 mm |
| 87 | SH- V (Credit for old dismantle material as and where basis etc as reqd) |
| 88 | Old assorted copper/aluminium wire |
| 89 | Old assorted 6/16 Amp Switch & sockets |
| 90 | Old assorted light fitting |
| 91 | Old assorted 1200 mm Ceiling Fan |
| 92 | Old assorted 1400 mm sweep Ceiling fans |
| 93 | Old assorted 300 mm sweep heavy duty exhaust fans |
| 94 | Old assorted 400 mm Wall Fan Oscillating type |
| 95 | Old assorted MCB (5-32 Amp) |
| 96 | Old assorted DP/TP (63/100Amp) |
| 97 | Old assorted G.I. Pipe Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender