Tender For Repair/Maint And Maintenance Of Lt Pannel, Feeder Pillar Boxes, Lt Switch Gears, Lt Oh/Ug Cables And Other Connected Wks At Otm Accn Area Under Ge (S) Patiala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Aug 2026
20 days left
EMD
64000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint And Maintenance Of Lt Pannel, Feeder Pillar Boxes, Lt Switch Gears, Lt Oh/Ug Cables And Other Connected Wks At Otm Accn Area Under Ge (S) Patiala
BOQ
| Sl. No. | Item Description |
| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | M&L for supply, laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 120 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately:- |
| 3 | All as per item No.2 here-in before but cable of size 3.5 core 95 sqmm complete all as specified and directed. |
| 4 | All as per item No.2 here-in before but cable of size 3.5 core 70 sqmm complete all as specified and directed. |
| 5 | All as per item No.2 here-in before but cable of size 3.5 core 50 sqmm complete all as specified and directed. |
| 6 | All as per item No.2 here-in before but cable of size 4 core 25 sqmm complete all as specified and directed. |
| 7 | All as per item No.2 here-in before but cable of size 4 core 16 sqmm complete all as specified and directed. |
| 8 | All as per item No.2 here-in before but cable of size 04 core 10 sqmm complete all as specified and directed. |
| 9 | M&L for removing all connections, bindings etc of ACSR/AAC conductor on existing LT poles & stretching of ACSR/AAC conductor upto required sag of any size and cross section of conductor and stretching of GI wire on existing pole including making necessary connection & binding with binding wire including cutting of tree branches from both sides upto the stress on each side complete all as specified and as directed. |
| 10 | Taking down unsv pin type insulator and providing new pin type, porcelain vitreous white brown or green insulator including one galvanized mild steel spindles, two galvanized iron washers and one galvanized iron nut 100mm height, 65 mm dia for 1100 Volt grade complete all as specified and as directed. |
| 11 | M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed. |
| 12 | Taking down U/S stay assy and M&L for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm ling 16mm dia , MS/GI stay bow 40cm lingh with 2 Nos GI thimbles, galvanized stay wire standard size 7/3.5mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and directed.Note : MS clamps will be measured & paid separately in respected items. |
| 13 | M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards, surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed. |
| 14 | Taking down rusted/unsv mild steel work and M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 15 | M&L in replacement of cradles, hexagonal/ rectangular fabricated with galvanised steel wire of size 4mm dia complete all as specified and directed. |
| 16 | M&L in repalcement of existing any type or any size aluminium conductor, steel reinforced including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed. |
| 17 | Excavation in trenches/post holes in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and as directed. |
| 18 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed. |
| 19 | Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed. |
| 20 | Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed.Note: Thickness after punning shall be measured for payment |
| 21 | Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed. |
| 22 | M&L for replacement of unserviceable steel tubular swaged pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial tape plug, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-31 (9.0 metre long) including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height completeincuding all as specified and as directed.Note:- Excavation and PCC works will be measured and paid separatly in respected items of this schedule. |
| 23 | M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed. |
| 24 | M&L for PCC work type D-2 (1:3:6) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed. |
| 25 | M & L for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping ( new and old damage coping) to poles / stays/strutus or basements etc complete all as specified and directed. |
| 26 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 80 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 27 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 28 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 100mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 29 | Supply and fixing in replacement of existing panel MCCB assessoriesd including making in coming /out going connections complete all as specified and directed |
| 30 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 31 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 32 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 33 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 125 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed. |
| 34 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range100 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz25 kA complete all as specified and directed. |
| 35 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 16 kA complete all as specified and directed. |
| 36 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range100 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz25 kA complete all as specified and directed. |
| 37 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 315 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 38 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 39 | S&F Digital Voltmeter of rating 0-500 V, size 96mm square type complete all as specified and as directed. |
| 40 | S&F Digital Ammeter of rating upto 0-600 Amp, size 96mm square type complete all as specified and as directed. |
| 41 | S&F Selector switch rotary type as per existing size complete all as specified and as directed. |
| 42 | LED Indicator assy with colour red/ yellow/ blue. |
| 43 | Copper Current transformer (CT) ratio 200/5 Amp (Set of 3 Nos). |
| 44 | Copper Current transformer (CT) ratio 800/5 Amp (Set of 3 Nos). |
| 45 | Copper Current transformer (CT) ratio 600/5 Amp (Set of 3 Nos). |
| 46 | Copper Current transformer (CT) ratio 500/5 Amp (Set of 3 Nos). |
| 47 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 630 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 50 kA, 50kA,thermal magnitc O/L and S/C protection complete all as specified and as directed. |
| 48 | Supply and fix LT spacer 05 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 05 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed. |
| 49 | Supply and fix LT spacer 04 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 04 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed. |
| 50 | Supply and fix LT spacer 03 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 03 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed. Make BHEL/Pactil/Rastriya/Jaipuria. |
| 51 | M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly in ground vertically in pit of size 900 x 900cm depth not less than 4.0 metre below normal ground level with top edge of the earth plate at a depth not less than2.56 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers (each layer of 0.23 cu. m) upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and as directed.Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. |
| 52 | M&L for replacement of unserviceable sheet metal enclosure power distribution board for independent mounting DRX 100 MCCB enclosure, including 63 Amp four pole, 415 volt,10kA and including necessary connection complete all as specified and directed. |
| 53 | M&L for replacement of unserviceable sheet metal enclosure power TPN , 4 way, DPX3 160 MCCB enclosure distribution board, complete all as specified and directed. |
| 54 | S & F in replacement of u/s MCB TP 32 Amp, 415 Volt, 'C' curve including necessary connection complete all as specified and directed. |
| 55 | S&F in replacement of u/s MCB SP 6 to 32 Amp, 415 Volt,'c' curve including necessary connection complete all as specified and directed. |
| 56 | M&L for paint to existing steel tubular 11 mtr pole of any type complete with two coat of aluminium synthetic enamel paint from bottom to top of the pole inculding black and yellow paint upto 1.5 Mtr height from bottom alernaterely strip 30 cm each including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as specified and directed. |
| 57 | All as per item no 56 but LT Pole upto 9 mtr complete all as specified and as directed. |
| 58 | Dismentaling of old steel tubular pole LT/HT after excavation of PCC and disconecting of cross arm and insulators,and shifting it to new location as required on site including all ACSR conductor any size/ cross arm/insulators connections including PCC work with ratio 1:3:6 and coping and testing of overhead line complete all as specified and directeded. |
| 59 | M&L and testing for end termination jointing kit suitable for 1100V, 16- 50 sqmm x 3.5 core XLPE cable heat shrinkable joint Outdoor complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed |
| 60 | M&L and testing for straight through jointing kit suitable for 1100V, 16- 50 sqmm x 3.5 core XLPE cable heat shrinkable joint Outdoor complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed |
| 61 | M&L and testing for end termination jointing kit suitable for 1100V, 70-120 sqmm x 3.5 core XLPE cable heat shrinkable joint outdoor complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed |
| 62 | M&L for XLPE grade cable for straight through joint kit suitable for 1100V, 70-150 sqmm, 3.5 core XLPE cable heat shrinable joint, complete all as specified and as directed. |
| 63 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed. |
| 64 | M&L for maintenance of outdoor type LT panel/feeder pillar box of any size/ make including insulating to bus bars with shrinkable PVC sleeves of colours red, yellow, blue and black replacement of worn out / us cables as per existing gauge, door rubber beedings, nuts, bolts washers, hinges, thimbles, lugs, cable glands & welding work etc making functional to the system and testing on load complete all as specified and as directed.Note:- Spares required for replacement will be measured & paid separately under respective items. |
| 65 | All as per Srl item No.64 above but indoor type LT Panel/ feeder box, complete all as specified and as directed. |
| 66 | M&L for painting to indoor/outdoor type LT panel/FP box of size not more than 1.8 m height internally as well as external surfaces complete with two coats of synthetic enameled paint of approved quality including preparation of old surfaces, writing of bus bars & outgoing /incoming locations with white paint gridth upto 2” (50mm) complete all as specified and as directed. |
| 67 | Taking out old unserviceable LT panel board, supply installation, testing and commissioning main LT Feeder panel board , outdoor type cubicle panel board suitable for 3 phase, 4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, with inner compartment made out of 2.15 mm the CRCA sheet duly compartmentalized for each MCCB's as incoming and outgoing with MCCB's, lockable arrangement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete all as specified and directed with following accessories. (Beta Complex) |
| 68 | Note:-(i) LT panel maker shall comply the IS/IEC-61439 (Part-1) : 2011 & IS/IEC-61439 (Part-2) : 2011(ii) Approval of panel drawing must obtained from AO before placing the order and PCC shall be measured and paid separately.INCOMING:- (a) MCCB 400 Amps, Adjustable thermal and magnetic type 4 pole, 415 Volts, 36 KA - 01 Nos (Ultimate breaking capacity ICs -Icu = 100 %) OUT GOING:- (a) MCCB 100A,415V 4 Pole,25 KA----8 Nos(b) MCCB 63 A,415V 4 Pole,16KA----01 Nos(c) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.(d) CT of suitable size(e) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(f) Wiring complete with copper wire of suitable size (g) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(h) Cable glands brass of suitable size for cable. |
| 69 | Taking down/removing carefully existing old rusted LT feeder pillar box with accessories and Supply, installation, design, fabrication, testing and commissioning of reputed factory made, outdoor type LT feeder pillar box mounted working on 440V, 3-phase, 50 Hz, AC supply, incluing PCC platform (300mm above from ground level and 450mm depth of foundation ), with double door shutters (front and rear side openable) made out of 3.15 mm CRCA sheet metal weather proof, dust and vermin proof, extendible type on both sides, seperate cubilcle / partition for switchgear (incoming and outgoings) with aluminium busbar (duly insulated PVC sleeves as per colour code) on suitable insulated supports, common earth bus at bottom, earth terminals on both sides of the panel for connecting earth stations, mechanical interlocking system for individual MCCB, ammeter, voltmeter with selector switches, indicating lamps LED type for RYB and on / off position, copper wound CTs for measuring and internal wiring with suitable size of PVC insulated copper wire, angle iron 50x50x6 mm frame at bottom, cable entry boxes with independent gland plates at bottom for each cable, lifting lugs, complete to accommodate including provisions for following switchgears all as per Single Line Diagram and as specified and painted as per the 7-tank process and painted for outdoor, weather proof IP-55 protection installation, including PCC work, excavation complete all as specified and as directed.Note : Panel shall be got fabricated from CPRI approved and company manufaturer only and depth of panel not less than 50CM.Location: KV School & 14scinde hrs offr Mess) |
| 70 | (a) Incomer : MCCB 4 Pole, 250A, DPX3 250 Thermal magnetic O/L and S/C protection , breaking 36kA, Including rotary handle (Cat part No.420249 of make Legrand or euqivalent in Siemens/Hagger)(b) Outgoing feeders : (i) 4 Pole MCCB 160A, 25kA - 2 Nos, Thermal magnetic O/L and S/C protection,Including rotary handle and one additional DPX spreader 3 links set (Cat Part No.420057 of make Legrand or Equivalent in Siemens/ABB.) (ii) MCCB TP 63 Amp , 16kA -2 Nos Including rotary handle and one additional DPX spreader 3 links set. (Cat Part No. 420003 of make Legrand or Equivalent in Siemens/ABB.)(c) Panel Fabrication and TPN alluminium bus bar of capacity 800 Amp, Amp merter 0-800Amps, volts meter 0-500 Votls for incomming MCCB , indicator (RYB) and selector switchs complete all as specified and directed.Note:(i) LT panel maker shall comply the IS/IEC-61439 (Part-1) : 2011 & IS/IEC-61439 (Part-2) : 2011(ii) Approval of panel drawing must obtained from AO before placing the order and PCC shall be measured and paid separately. |
| 71 | M&L for feeder pillar bus bar box of size of size 750x500x500mm of outdoor type 3.15mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 200 Amp mounted on porcelain insulator, including MCCB 160 Amps, adjustable ,36 kA,= 01 No, Amp meter 0-200 Amps, volts meter 0-500 Volts for incoming supply , LED indicator (RYB) and selector switches and 08 Nos holes in bottom for inlet and outlet cable with suitable size of cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 mm X 50 mm X 6 mm, 1.05 meter high (450mm below ground level and 600mm above ground) along with necessary cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed complete with one coat of primer and two coats of synthetic enamel paint complete all as specified and as directed. |
| 72 | Supply and fixing street light junction box of size 300 mm x 200 mm x 105 mm, made out of FRP sheet with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Apms MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed. |
| 73 | Supply and spreading graded coarse aggregate of size 20-63 mm at electrical outdoor installation yard 11KV Substations/ Near DP structures etc including leveling of uneven surface, removing vegetation, grass etc complete all as specified and directed. |
| 74 | Supply and fix PVC electric cable with insulated aluminium conductor (stranded) with inner sheathing of PVC tape and overall PVC sheathed 1100 volts grade, heavy duty, 10 sqmm twin core, weather proof flat with accessories, complete all as specified and directed. |
| 75 | Supply and fix electric cable with insulated aluminium conductor (stranded) with inner sheathing of PVC tape and overall PVC sheathed 1100 volts grade, heavy duty, 6 sqmm twin core, weather proof flat with accessories, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender