Tender For Repair And Maintenance To Lt Oh, Underground Electric Supply Network, Connected Works And Distribution Network At Nabha And Sangrur Under Ge (S) Patiala.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Aug 2026
20 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance To Lt Oh, Underground Electric Supply Network, Connected Works And Distribution Network At Nabha And Sangrur Under Ge (S) Patiala.
BOQ
| Sl. No. | Item Description |
| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed.(Qty Nabha- 343.44 & Sangrur - 357.48) |
| 3 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed.Note: Only Punned sand shall be measured and paid. |
| 4 | Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable complete all as specified and directed. |
| 5 | Returning filling in including ,spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed |
| 6 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 7 | M&L for painting of sign board (size 1x1 mtr to 1.5x1.5 mtr) at sub stations by cleaning of surface by emery paper, applying single coat of redoxide as primer and double coat of synthetic enamel paint and marking of nomeclature of the installation with suitable size letter writting in capital letters complete all as specified and directed.Note:- Size of letter, colour of paint will be decided by Engr-in-Charge.(Qty Nabha- 5) |
| 8 | M&L painting of Rolling Shutter, Iron Gates, LT Panels and AFPC Panels etc. by prepareing & cleaning of surface by removing girth, applying single coat of redoxide as primer and double coat of paint by spay painting complete all as specified and directed.(Qty Nabha- 90) |
| 9 | M&L for Numbering of Poles (Steel & RCC poles) by painting of surface in circular Shape in Yellow Colour and numbering in black colour complete all as specified and directed.(Qty Nabha- 150 & Sangrur - 130) |
| 10 | M&L Painting of Steel tubular LT Poles (approx 7 mtr height) by cleaning of surface by emery paper, applying single coat of redoxide as primer and double coat of aluminium paint and above coping level in five alternate layers of black and yellow colour of width 15 cm each and including aluminium paint of brackets, clamps, junction boxes other fittings fixed on the pole complete all as specified and directed.(Qty Nabha- 100 & Sangrur - 100) |
| 11 | M&L for painting the Poles (RCC poles) above coping level in five alternate layers of black and yellow colour of width 15 cm each and including silver painting of brackets, clamps, junction boxes and other fittings fixed on the pole complete all as specified and directed.(Qty Nabha- 150 & Sangrur - 400) |
| 12 | Dismantling of old unsv LT PCC Pole any type from root incl PCC & masonary work completely from ground and complete all as specified and directed.Note :- Removal item will be deposited at site as directed(Qty Nabha- 6 & Sangrur - 6) |
| 13 | S&F Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 incl erection of LT OH ACSR conductor complete all as specified and directed.(Qty Nabha- 14 & Sangrur - 14) |
| 14 | Dismantling of Cross arms, bracing, supports, clamps and back plates etc from LT poles complete all as specified and directed.(Qty Nabha- 1 & Sangrur - 0.5) |
| 15 | S&F Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.(Qty Nabha- 1 & Sangrur - 0.5) |
| 16 | Dismantling of insulators any type, any size from LT Pole complete all as specified and directed.(Qty Nabha- 30 & Sangrur - 30) |
| 17 | S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and as directed.(Qty Nabha- 30 & Sangrur - 15) |
| 18 | M&L for Dismantling stay assembly complete incl demolition of concrete, etc. and excavation. S&F Stay assembly with stay rod of size 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, plates incl cost of excavation and concrete cement & masonary work all as directed. (Qty Nabha- 6 & Sangrur - 6) |
| 19 | M&L for dismantling unsv Stay strand, Supply & Fix Galvanised stay strand, 7/4 mm with accessories complete all as specified and directed.(Qty Nabha- 0.5 & Sangrur - 0.5) |
| 20 | S&F in replacement of PVC insulated jumpers of suitable size PVC cable suitable for LT OH Conductor line 1100 volts of suitable size & length complete all as specified and directed.(Qty Nabha- 40 & Sangrur - 40) |
| 21 | Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) ncluding nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.(Qty Nabha- 0.6 & Sangrur - 0.6) |
| 22 | S&F in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.(Qty Nabha- 100 & Sangrur - 100) |
| 23 | S&F No Admission Board notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures in signal red colour and fixed with M.S. clamps, bolts and nuts of suitable size of 30x20 cm size complete all as specified and directed.(Qty Nabha- 6 & Sangrur - 6) |
| 24 | S&F in replacement of Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia to safeguard from OH LT lines 1100 volt grade complete all as specified and directed.(Qty Nabha- 1 & Sangrur - 1) |
| 25 | S&F in replacement of Shackle Type, Porcelain, vitreous, Brown insulator of 1100 volts garde, height 100 mm and dia 115 mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts complete all as specified and directed.(Qty Nabha- 30 & Sangrur - 30) |
| 26 | M&L for Servicing and Calibration of LT ACB circuit breaker installed in LT panel 440 volts of rating 630/800 Amp grade by cleaning of Panel & ACB by air blower, cleaning of deposited carbon and applying petrolium jelly, setting of tripping time and short circuit relay, earth fault, fault relay etc by engaging of experienced technician complete all as specified and directed.(Qty Nabha- 2) |
| 27 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth wire 4 sqmm by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC/CI cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I.(Qty Nabha- 8 & Sangrur - 8) |
| 28 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 Sqmm dia galvanised iron or steel wire complete all as specified and directed.(Qty Nabha- 30 & Sangrur - 30) |
| 29 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32x6 mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I(Qty Nabha- 8 & Sangrur - 8) |
| 30 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm size GI Strip complete all as specified and directed.(Qty Nabha- 20 & Sangrur - 20) |
| 31 | Taking out unsv LT Cable & Supply, laying, Jointing connecting new LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 sqmm 3.5 core laid in trenches/on poles/walls/in ducts/passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.(Qty Nabha- 45) |
| 32 | All as per serial item no 31 above but for 185 Sqmm 3.5 Core complete all as specified and directed.(Qty Nabha- 30 & Sangrur - 20) |
| 33 | All as per serial item no 31 above but for 150 Sqmm 3.5 Core complete all as specified and directed.(Qty Nabha- 50) |
| 34 | All as per serial item no 31 above but for 120 Sqmm 3.5 Core complete all as specified and directed.(Qty Nabha- 80) |
| 35 | All as per serial item no 31 above but for 95 Sqmm 3.5 Core complete all as specified and directed.(Qty Nabha- 100 & Sangrur - 100) |
| 36 | All as per serial item no 31 above but for 70 Sqmm 3.5 Core complete all as specified and directed.(Qty Nabha- 100 & Sangrur - 100) |
| 37 | All as per serial item no 31 above but for 50 Sqmm 3.5 Core complete all as specified and directed.(Qty Nabha- 200 & Sangrur - 100) |
| 38 | All as per serial item no 31 above but for 35 Sqmm 3.5 Core complete all as specified and directed.(Qty Nabha- 200 & Sangrur - 200) |
| 39 | All as per serial item no 31 above but for 25 Sqmm 4 Core complete all as specified and directed.(Qty Nabha- 150 & Sangrur - 200) |
| 40 | All as per serial item no 31 above but for 16 Sqmm 4 Core complete all as specified and directed.(Qty Nabha- 150 & Sangrur - 200) |
| 41 | All as per serial item no 31 above but for 16 Sqmm 2 Core complete all as specified and directed.(Qty Nabha- 200 & Sangrur - 200) |
| 42 | All as per serial item no 31 above but for 10 Sqmm 2 Core,complete all as specified and directed.(Qty Nabha-100 & Sangrur - 150) |
| 43 | All as per serial item no 31 above but for 10 Sqmm 4 Core,complete all as specified and directed.(Qty Nabha- 200 & Sangrur - 200) |
| 44 | All as per serial item no 31 above but for 6 Sqmm 2 Core, complete all as specified and directed.(Qty Sangrur - 150) |
| 45 | S&F in replacement of Aluminum thimbles suitable for 150 to 240 Sqmm 3.5 Core LT Cable by dismantling of LT cable from transformer/MCCB/Bus bar etc and cutting cable core ends and making fresh for fixing of new thimbles by using crimping tool, applying LT insulation tap & testing complete all as specified and directed.Note :(Thimles for RYB & N will be count as one set)(Qty Nabha- 12) |
| 46 | All as per item no 45 above but for 70 to 120 Sqmm,complete all as specified and directed.(Qty Nabha- 12) |
| 47 | All as per item no 45 above but for 25 to 50 Sqmm, complete all as specified and directed.(Qty Nabha- 30) |
| 48 | S&F Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor/indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 2/3.5/4 Core XLPE armoured /PVC aluminium conductor cable of size16 to 35 Sqmm complete all as specified and directed.(Qty Nabha-5 & Sangrur - 5) |
| 49 | All as per serial item no 48 above but for cable of size 50- Sqmm to 95 Sqmm complete all as specified and directed.(Qty Nabha- 6 & Sangrur - 5) |
| 50 | All as per serial item no 48 above but for cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.(Qty Nabha- 3 & Sangrur - 1) |
| 51 | All as per serial item no 48 above but for cable of size 240 Sqmm complete all as specified and directed.(Qty Nabha- 1) |
| 52 | S&F Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured /PVC aluminium conductor cable of size 70-185 Sqmm complete all as specified and directed.(Qty Nabha- 3 & Sangrur - 4) |
| 53 | Supply and fix in replacement of 630 Amps MCCB, 415 Volts, 50 HZ, Breaking capacity 50 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed.(Qty Nabha- 2 & Sangrur - 2) |
| 54 | Supply and fix in replacement of 400 Amps MCCB, 415 Volts, 50 HZ, Breaking capacity 36 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed.(Qty Nabha- 4 & Sangrur - 3) |
| 55 | Supply and fix in replacement of MCCB 250 Amps, 415 Volts, 50 HZ, Breaking capacity 25 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed(Qty Nabha- 4 & Sangrur - 4) |
| 56 | Supply and fix in replacement of MCCB FP 200 Amps, 415 Volts, 50 HZ, Breaking capacity 25 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed.(Qty Nabha- 2) |
| 57 | Supply and fix in replacement of MCCB FP 160 Amps, 415 Volts, 50 HZ, Breaking capacity 25 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed.(Qty Nabha- 4 & Sangrur -5) |
| 58 | Supply and fix in replacement of MCCB FP 125 Amps, 415 Volts, 50 HZ, Breaking capacity 25 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed.(Qty Nabha- 2 & Sangrur - 5) |
| 59 | Supply and fix in replacement of MCCB FP 100 Amps, 415 Volts, 50 HZ, Breaking capacity 25 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed.(Qty Nabha- 4 & Sangrur - 4) |
| 60 | Supply and fix in replacement of MCCB FP 63 Amps, 415 Volts, 50 HZ, Breaking capacity 25 KA, 4 Pole, with thermal and Magnetic adjustment complete all as specified and as directed.(Qty Nabha- 3 & Sangrur - 4) |
| 61 | Supply and fix in replacement of digital type Voltmeter 3 phase system with selector switch 440 volts AC incl taking out the old one complete all as specified and as directed.(Qty Nabha - 2 & Sangrur - 2) |
| 62 | Supply and fix in replacement of digital type Ammeter 3 phase system with selector switch alon with suitable CTS, 440 volts AC with input current 5Amps incl taking out the old one complete all as specified and as directed.(Qty Nabha- 2 & Sangrur - 2) |
| 63 | Supply and fix in replacement LED type indication lamp set R-Y-B working at 220/240 V0lts AC incl taking out the old one complete all as specified and as directed. (Qty Nabha- 12 & Sangrur - 12) |
| 64 | S&F in replacement of RYB selector switch for LT Panel/APFC Panel complete all as specified and directed.(Qty Nabha- 6 & Sangrur - 4) |
| 65 | S&F in replacement of 415V 10KA 'C' Curve MCB TP 25 to 63 Amps rating, 10 KA in the DB/LT Panel/APFC Panel complete with connection testing and commissioning complete all as specified and directed.(Qty Nabha- 6 & Sangrur - 4) |
| 66 | S&F in replacement of Start Push Button (Green Colour) and Stop Button (Red Colour) in RYB selector switch for APFC/Starter Panel complete all as specified and directed.(Qty Nabha- 4) |
| 67 | M&L for treaming of tree/ tree branches spreaded over/touching the LT OH ACSR conductors/LT Poles/ LT Panels etc by taking proper shut down from MES all as directed by Engr-in-Charge. Note:- Contractor will provide all tools, ladder and safety equipments required for treaming of tree /tree branches.(Qty Nabha- 130) |
| 68 | Dismantling of OH ACSR conductor from LT Poles and jointing/tightening of the broken/loose conductors and refixing the same on the LT Poles as in position as existing incl cost of jointing material, cleaning of pin insulators complete all as specified and directed.(Qty Nabha- 40 & Sangrur - 40) |
| 69 | M&L for Dismantling of ACSR conductors and, S&F Auminium conductor steel reinforced as per IS-398 (Part-2) of of 1996 suitable for 1100 volts OH line complete all as specified and directed.(Qty Nabha- 2 & Sangrur - 1) |
| 70 | S&F in replacement of CT Coil ratio of rating 200/5, 50 Hz, Line voltage 440V, as per ISS-2705-1992 suitable for Existing LT Panel incl taking out unsv CT any type all as specified and directed. (for RYB will be count as 01 set) complete all as specified and directed.(Qty Nabha- 2) |
| 71 | S&F in replacement of CT Coil ratio of rating 400/5, 50 Hz, Line voltage 660V, as per ISS-2705-1992 suitable for Existing LT Panel incl taking out unsv CT any type all as specified and directed.(Qty Nabha- 2) |
| 72 | S&F PVC spacer 4/5 way suitable for LT OH conductor 1100 Volts grade complete all as specified and directed. (Qty Nabha- 120 & Sangrur - 100) |
| 73 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including PCC/masonary work to fix lanterns on post top all as specified and directed. (Qty Nabha- 8 & Sangrur - 4) |
| 74 | M&L Cutting of road /PCC path upto the depth of pipe & making good the disturbed surface with PCC 1:2:4 (20 mm aggregate) using extra cement including earth work complete all as specified and directed.(Qty Nabha- 40 & Sangrur - 10) |
| 75 | M&L for trench less drilling of road/PCC surface by machine without damaging near by area, depth as per site requirement for crossing of LT cables protection pipe including cost of PCC 1:3:4 for making good the disturbed surface of road/floor/PCC complete all as specified and directed.(Qty Nabha- 20 & Sangrur -15) |
| 76 | M&L for GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole bend type for junction box complete all as specified and directed(Qty Nabha- 80) |
| 77 | All as per item no 76 above but for 50 mm bore complete all as specified and directed.(Qty Nabha- 30 & Sangrur - 15) |
| 78 | All as per item no 76 above but for 80 mm bore complete all as specified and directed.(Qty Nabha- 20 & Sangrur - 15) |
| 79 | M&L PCC 1:2:4 ype B2 ( using 20/40 mm graded stone aggregate) as in coping/ foundation / filling and mass concrete (new & existing poles) complete all as specified and directed.(Qty Nabha- 2 & Sangrur - 2) |
| 80 | M&L PCC 1:3:6 ype B2 ( using 20/40 mm graded stone aggregate) as in foundation / filling and mass concrete (new & existing poles) complete all as specified and directed(Qty Nabha-4.04 & Sangrur - 7.07) |
| 81 | M&L PCC 1:4:8 type D2 ( using 40 mm graded stone aggregate) as in foundation of poles and stay etc complete all as specified and directed.(Qty Nabha- 0.43 & Sangrur -0.76) |
| 82 | M&L for Cable route indicator shown \\"LT UG Cables\\" painted in blue/red colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in suitable size MS angle/rod, 60 cm long ( all word embosed) and embaded in PCC block of size 20 x 20 x 50cm in ground, complete all as specified and directed.(Qty Nabha- 20 & Sangrur - 10) |
| 83 | M&L for Servicing of High Mast Light complete incl cleaning and greasing and testing for satiafactory operation as per manufacturer standards complete all as specified and directed.(Qty Nabha- 2 & Sangrur -6) |
| 84 | Supply and replacement of High Mast Light forward and reverse starter and 24 hrs timer as per existing make and model and making all connections as per existing complete all as specified and directed.(Qty Nabha- 1 & Sangrur - 2) |
| 85 | S&F in repairs LED aviation light 10 watt as per existing make and model and making all connections as per existing at height of 15 mtr long high mast pole complete all as specified and directed.(Qty Nabha- 2 & Sangrur - 5) |
| 86 | M&L for servicing and complete repair of Servo voltage stabilizer 200 KVA including replacement of all defective parts,calibration/setting of all parameters, cleaning and greasing and testing for satiafactory operation as per manufacturer standards complete all as specified and directed.Note- UNSV parts incl in qtd rates.(Qty Nabha- 1) |
| 87 | M&L for servicing and complete repair of Servo voltage stabilizer 100 KVA including replacement of all defective parts,calibration/setting of all parameters, cleaning and greasing and testing for satiafactory operation as per manufacturer standards complete all as specified and directed.(Qty Sangrur - 1) |
| 88 | Supply installed testing and comminsioning , outdoor type,Self standing, double door, front and back openable, APFC panel fabricated ( Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) compartmental type with APFC relay 9 stage with heavy duty MPP capacitor bank 100 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+3x 10 KVAr + 3 x 20KVAr with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each capacitor control and MCCB TPN 160 Amp 16 KA as incomer including control CT & control wiring complete dust and vermin proof double door made out of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys having following assessories including control wiring with HR FRLS copper wire complete all as specified & directed. |
| 89 | (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry(ii) Capacitor installed in removable assemblies for ease of operation and maintenance(iii) Incoming of APFC panel of MCCB TPN 160 Amps, 16 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating.(iv) 100 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+3x 10 KVAr + 3 x 20KVAr) with 7% detuned harmonics filter reactor. with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control (each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor.(v) High performance microprocessor based 3 phase APFC relay 9 stage with Auto/Manual Option. |
| 90 | (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No)(vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors(viii) Induced air system provided with axial flow fan/ centrifugal fan.(ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front(x) The canopy shall be exposed not less then 15cm both side Please Enable Macros to View BoQ information |
| 91 | (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No)(vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors(viii) Induced air system provided with axial flow fan/ centrifugal fan.(ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front(x) The canopy shall be exposed not less then 15cm both side Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender