Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door, with R Y B Phase indication and MCB position indication through glass front, IP-54, Prewired with HFFR / FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge
28 way, TPN MCB DB with Incomer of 40A, Isc=10kA, Type C, (100mA) 40A DP RCBO for each phase and 24 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
36 way, TPN MCB DB with Incomer of 40A, Isc=10kA, Type C, (100mA) 40A DP RCBO for each phase and 18 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
46 way, TPN MCB DB with Incomer of 32A, Isc=10kA, Type C, (100mA) 32A DP RCBO for each phase and 18 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
56 way, TPN MCB DB with Incomer of 16A, Isc=10kA, Type C, (100mA) 16A DP RCBO for each phase and 18 Nos of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
64 way, TPN MCB DB with Incomer of 40A, Isc=10kA, Type C, (100mA) 40A DP RCBO for each phase and 12 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
74 way, TPN MCB DB with Incomer of 25A, Isc=10kA, Type C, (100mA) 25A DP RCBO for each phase and 12 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
84 way, TPN MCB DB with Incomer of 16A, Isc=10kA, Type C, (100mA) 16A DP RCBO for each phase and 12 Nos of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
9Supply, Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, double door, with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR / FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge
1010 way, DP MCB DB with Incomer of 32A, Isc=10kA, Type C and 10 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
1110 way, DP MCB DB with Incomer of 16A, Isc=10kA, Type C and 10 Nos of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
126 way, DP MCB DB with Incomer of 40A, Isc=10kA, Type C and 6 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
136 way, DP MCB DB with Incomer of 32A, Isc=10kA, Type C and 6 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
146 way, DP MCB DB with Incomer of 16A, Isc=10kA, Type C and 6 Nos of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
154 way, DP MCB DB with Incomer of 32A, Isc=10kA, Type C and 4 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
164 way, DP MCB DB with Incomer of 25A, Isc=10kA, Type C and 4 Nos of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification
17Supply, Installation, Testing and Commissioning of LED light fittings complete with light fitting accessories, including supply of fixing accessories, twin twisted tinned 1.5 sqmm copper flexible cords for terminal connections, 16 SWG copper wire for earthing, flexible PVC coated GI metallic conduit sleeves, PVC conduit bushes, cable lugs and testing and commissioning as per technical specification
18SITC of 4ft Slim LED Batten with a nominal system lumen output of 2100 lumens and a minimum system efficacy of 115 lm/W.The luminaire should have CCT 6500K and CRI > 80. The luminaire shall meet IP20 protection rating with THD < 10% and PF > 0.9. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 19W (including driver)
19SITC of 4ft Industrial Batten with 1x40W LED Tube (Surface or Pendent mounted) with a nominal system lumen output of 4400 lumens and a minimum system efficacy not less than 110lm/W. The luminaire should have a colour temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF>0.95. The luminaire housing should made of white powder coated CRCA sheet steel. The total power consumption should not exceed 42W (including driver)
20SITC of 34 Watt LED wellglass peripheral luminaire with a nominal system lumen output atleast 3700 lumens and a minimum system efficacy 120 lumen/watt. The luminaire should have CCT 6500K, CRI>80 with Opal di„ffuser in polycarbonate cover. The luminaire shall meet IP65, IK 08 rating with THD<10%, PF>0.95 and SDCM<5. The luminaire housing should be made of pressure die cast aluminium
21SITC of Industrial LED Recessed mounted 1X28W Luminaire with a nominal system lumen output of at least 3700 lumens and a minimum system efficacy of 140 lm/W. The luminaire should have a colour temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF >0.95 & SDCM<4. The luminaire housing should made of powder coated metallic CRCA with high efficiency opal diffuser. The total power consumption should not exceed 30W (including driver)
22SITC of Industrial LED Recessed mounted 2X28W Luminaire with a nominal system lumen output of at least 7800 lumens and a minimum system efficacy of 140 lm/W. The luminaire should have a colour temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF>0.95 & SDCM<4. The luminaire housing should made of powder coated metallic CRCA with high efficiency opal diffuser. The total power consumption should not exceed 60W (including driver)
23SITC of LED integral driver 100W flood light Industrial Batten Surface mounted with a nominal system lumen output of 12500 lumens and a minimum system efficacy of 125 lumen/watt. The luminaire should have cool white colour temperature 6500K and a CRI>80. The luminaire shall meet IP66 rating with THD<10% & PF>0.9 complete with light fitting SS accessories, flexible PVC coated GI metallic conduit sleeves, Cu lugs, powder coated pre-galvanised terminal box. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 104 W (including driver)
24SITC of light fitting, LED Bulkhead type with a nominal system lumen output of 1200 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 5700K and CRI>80. The luminaire shall meet IP65 rating with THD<10% and PF>0.95 , L70B50 shall be 50000 hours, complete with light fitting SS accessories, PVC coated flexible GI metallic conduit sleeves, Cu lugs, 3 inch pvc terminal box. The luminaire housing should have made of High pressure die cast Aluminium with high quality PMMA diffuser. The total power consumption should not exceed 10W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications
25SITC of LED surface type sleek Downlighter with a nominal system lumen output of 1300 lumens and a minimum system efficacy of not less than 105lm/W. The luminaire should have a colour temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF>0.9. The luminaire housing should be made of polycarbonate with high efficiency diffuser. The total power consumption should not exceed 12W (including driver)
26SITC of light fitting, LED High-bay type with a nominal system lumen output of 12,500 lumens and a minimum system efficacy of not less than 140 lm/W. The luminaire should have a CCT of 5700K and CRI>80. The luminaire shall meet IP66 and IK 08 rating with THD<10% and PF>0.95, L70B50 shall be 50000 hours, complete with light fitting SS accessories, flexible PVC coated GI metallic conduit sleeves, Cu lugs, powder coated pre-galvanised terminal box. The luminaire should be tested from NABL accredated LAB and should have proper IES file The luminaire housing should have made of High Pressure die cast Aluminium with wide beam optics. The total power consumption should not exceed 90W and other requirements shall be as per tender technical specifications
27Supply, Installation, Testing and Commissioning of LED Highbay with a nominal system lumen output of 19500 lumens and a minimum system efficacy of 130 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI > 80 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV complete with light fitting SS accessories, flexible PVC coated GI metallic conduit sleeves, Cu lugs, powder coated pre-galvanised terminal box. The luminaire should be tested from NABL accredated LAB and should have proper IES file. The luminaire housing should made of High Pressure die cast Aluminium with narrow beam optics and having gasket of heat proof siliconerubber ring. The total power consumption should not exceed 157W (including driver)
28Supply and Installation of the following modular heavy duty polycarbonate, Fire Retardant, ISI marked switches, sockets, plug tops and combined face plates ( size suit at site) in the existing recess mounted GI box / surface mounting as per technical specification
291 Nos of 1M 6 Amp switch and suitable heavy duty polycarbonate, fire Retardant, ISI marked combined face plate for existing recess mounted GI box
302 Nos of 1M 6 Amp switch and suitable heavy duty polycarbonate, fire Retardant, ISI marked combined face plate for existing recess mounted GI box
311 Nos of 1M 6 Amp switch and suitable 1M heavy duty polycarbonate, fire Retardant, ISI marked combined face plate and box for surface mounting
322 Nos of 1M 6 Amp switch and suitable 2M heavy duty polycarbonate, fire Retardant, ISI marked combined face plate and box for surface mounting
331 Nos of 6 / 16 Amp (compatible with both 6 and 16 Amp) 2M Heavy duty Shuttered socket with suitable heavy duty polycarbonate, fire Retardant combined face plate for existing recess mounted GI box with 1 Nos of 2M Plug Top
341 Nos of 1M 16 Amp switch, 1 Nos of 6 / 16 Amp (compatible with both 6 and 16 Amp) 2M Heavy duty Shuttered socket with suitable heavy duty polycarbonate, fire Retardant combined face plate for existing recess mounted GI box with 1 Nos of 2M Plug Top
352 Nos of 1M 16 Amp switch, 2 Nos of 6 / 16 Amp (compatible with both 6 and 16 Amp) 2M Heavy duty Shuttered socket with suitable heavy duty polycarbonate, fire Retardant combined face plate for existing recess mounted GI box with 2 Nos of 2M Plug Top
361 Nos of 1M 16 Amp switch, 1 Nos of 6 / 16 Amp (compatible with both 6 and 16 Amp) 2M Heavy duty Shuttered socket with suitable 3M heavy duty polycarbonate, fire Retardant combined face plate and box for surface mounting with 1 Nos of 2M Plug Top
372 Nos of 1M 16 Amp switch, 2 Nos of 6 / 16 Amp (compatible with both 6 and 16 Amp) 2M Heavy duty Shuttered socket with suitable 6M heavy duty polycarbonate, fire Retardant combined face plate and box for surface mounting with 2 Nos of 2M Plug Top
384 Nos of 1M 16 Amp switch, 4 Nos of 6 / 16 Amp (compatible with both 6 and 16 Amp) 2M Heavy duty Shuttered socket with suitable 12M heavy duty polycarbonate, fire Retardant combined face plate and box for surface mounting with 4 Nos of 2M Plug Top
39Supply of Single Core HFFR wires (Copper) of size 1.5 sqmm in voltage grade 1100 V as per the IS 17048:2018 (latest edition) and as per conductor class 2 of IS: 8130/1984 as per technical specification
40Supply of Single Core HFFR wires (Copper) of size 2.5 sqmm in voltage grade 1100 V as per the IS 17048:2018 (latest edition) and as per conductor class 2 of IS: 8130/1984 as per technical specification
41Installation / drawing through concealed / surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size 1.5 sqmm in voltage grade 1100V as per the IS 17048:2018 as per conductor class 2 of IS:8130/1984 as per technical specification
42Installation / drawing through concealed / surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size 2.5 sqmm in voltage grade 1100V as per the IS 17048:2018 as per conductor class 2 of IS:8130/1984 as per technical specification
43Supply and laying of 95 sqmm stranded bare tinned copper conductor at 1000 mm below ground level including excavation, brazing, connection to earth pits, refilling the trench etc as per tender specifications
44Supply and laying of 10 sqmm stranded bare tinned copper conductor on surface / concealed including clamping / cleating on structure / floor / ceiling / wall / tray, making chase, repairing the same, interconnection through brazing / bolting etc as required per tender specifications
45Supply and laying of 2 x 10 sqmm stranded Cu, PVC insulated earthing conductor in 25 mm HDPE pipe including underground laying with excavation / clamping / cleating on surface / floor / ceiling / wall / tray, making chase, repairing the same, connection through brazing / bolting etc as per instructions by Engineer-In-Charge (Supply of HDPE pipe included in Contractor's scope)
46Supply and Installation of Copper lug suitable for 95 sqmm stranded tinned copper conductor
47Supply and Installation of Copper lug suitable for 10 sqmm stranded tinned copper conductor
48Supply and Installation of M10 brass nut bolt, 3/4\\" long suitable for 10 mm threaded hole for making connection to earth pad
49Supply, Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor with inbuilt or external power pack and auxiliary relay having min 15 mtr sensing range in 180 deg orientation and time delay ranges from 30 sec to 30 min and should have output relay capacity of 1000 W (for LED lighting fixtures)
50Supply, Installation, Testing and Commissioning of Occupancy sensor bypass switch box having 3 pole rotary switch fixed on GI enclosure with cover
51SITC of Junction box / Cable pull box shall be weather proof type, size 100mm x 100mm x 50mm fabricated out of 2mm thick GI sheet, cable gland plate at bottom, punched hole for conduit entry on all sides, suitable to terminate 2 Nos of 3 core x 2.5 sqmm Cu conductor, 8 Nos of terminals, etc as required
52Supply and embedment of heavy duty hot dipped 25 mm GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc, including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting and laying in brick wall, etc as required under the instruction of Engineer-in-charge. Surface mounted Junction box of suitable size as required at site shall be provided
53Supply and embedment of heavy duty hot dipped 40 mm GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc, including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting and laying in brick wall, etc as required under the instruction of Engineer-in-charge. Surface mounted Junction box of suitable size as required at site shall be provided
54Supply and Installation of flexible GI conduit pipe of size 26 mm including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc as required under the instruction of Engineer-in-charge and as per tender specification
55Making the opening in brick masonry for door / window / clear story opening including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface including disposal of mulba / rubbish to the nearest dumping ground
56Supply and Installation of 2 mm thick pre-galvanised GI sheet powder coated including marking, cutting (as per site requirement) and erection on top of JB openings on wall and ceiling at approximate height of 7 mtrs
57Supply and Laying of 14 SWG Cu-ETP grade bare solid tinned copper conductor throughout along the surface / concealed conduit including fixing with hose clips / clamps etc
58Supply and fixing of vertical air termination made up of 20 mm dia, 1 mtr long copper rod attached to 50 mm dia Copper sphere having drilled and tapped holes for fixing 5 Nos of 150 mm long spikes and square copper base plate of 150 mm length and 10 mm thickness as per latest IS & technical specification and approved drawing
59Supply and Installation of GI Anchor Fastener of size M8 x 80 MM by drilling through concrete block as per site requirement for fixing plate EP's or other structures as per the tender specification
60Supply, Fabrication and Installation of Standard steel sections as per IS 2062 Grade BR for light frame, base frame, wall frames, brackets for supporting equipments etc. including all accessories, SS screw, bolts etc. Fabrication shall include drilling, entiling, welding by qualified welder, wire brush cleaning, testing DPT etc. Supply of all consumables like gas, approved welding rods as per EIC and tender tech spec. After fabrication two coats of epoxy based primer and two coats of finish epoxy paints shall be applied
61Supply and Installation of powder coated wall mounted PA Main Junction Box (PJB) made of 14SWG, (M.O.C: Pre-Galvanized G.I sheet steel), punched hole for conduit entry on all sides and suitable for incoming cable of size 10 pair x 1.5 sq.mm. armoured twisted pair cable. The junction box shall consist of 20 Nos terminals suitable for 1.5 sq.mm as per the technical specification
62Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 200 + 200 pairs of Telephone cable as per the technical specification
63Supply and Installation of Indoor type (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector made of 14SWG for 50 + 50 pairs of Telephone cable as per the technical specification
64Supply and drawing of 2 Pair 0.6 sqmm copper conductor Telephone cable from EPABX Main JB upto RJ-11 socket unit of individual telephone instrument through concealed conduit including end termination in RJ-11 socket units
65Supply, drawing / laying & termination of 1 pair, 1.5 Sqmm, Flexible, overall Aluminum Mylar screen with drain wire, Copper, Multistranded conductor, Unarmoured, FRLS PVC sheathed (Inner and Outer) as per attached technical specifications
66Supply, drawing / laying & termination of 10 pair, 1.5 Sqmm, Flexible, overall Aluminum Mylar screen with drain wire, Copper, Multistranded conductor, Armoured, FRLS PVC Sheathed (Inner and Outer) as per attached technical specifications
67Supply and Laying of 50 Pair, 0.5 mm dia copper conductor, jelly filled armoured telephone cable
68Supply and Installation of 2 Way Prefabricated GI box to accomodate modular type RJ-11 socket unit suitable for surface mounting
69Supply and Installation of 2 Way heavy duty polycarbonate, Fire Retardant, ISI marked Front plate with modular type Four Pin RJ-11 socket unit
70Supply and Installation of Ceiling Rose for termination of 1.5 sqmm cable for PA system Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56768073
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.63 Crore
LAST DATE 11-08-2026
Authority
Authority Name Bhabha Atomic Research Centre
Work Description Tender for Electrification Works Of Block 109 At Inrp Site Tarapur
Basic Detail
Tender No BARC(T)/NRB/INRPC/ELE-66/2026
Bidding Type Tender
Location
City Palghar
State Maharashtra
Key Dates
Publish Date 31 Jul 2026
Submission Date 11 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 1.63 Crore
Tender Fee Ref. Documents
EMD 3.26 Lakhs
Exemption Not Available
Document List
9df48d8c-13c0-4750-801b-73e004ec96b6.html
BOQ_966867.xls
Techbid66.xls
Tenderdoc66.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

9df48d8c-13c0-4750-801b-73e004ec96b6.html

xls

BOQ_966867.xls

xls

Techbid66.xls

pdf

Tenderdoc66.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders