Tender For Sv Station Piping Modification With Hot Tapping, Pig Valve Installation & Development Of Water Injection Facility At Sv-7 Cum Rcp Station (Mouza- Pitwans) At Ch. 119.3 Km (Ex.Hathidah) Of Hathidah-Gidha Section Of Phbmpl
Tender Overview
Project Description
Tender for Sv Station Piping Modification With Hot Tapping, Pig Valve Installation & Development Of Water Injection Facility At Sv-7 Cum Rcp Station (Mouza- Pitwans) At Ch. 119.3 Km (Ex.Hathidah) Of Hathidah-Gidha Section Of Phbmpl
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2026 | Corrigendum 3 | Technical Bid | 28-Aug-2026 |
| 2 | 21-Aug-2026 | Corrigendum 2 | Date | 28-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ. |
| 2 | MECHANICAL WORKS |
| 3 | BALL API6D,HOV,F/F, A/G, TRU,BOL,FIR,2,600 |
| 4 | BALL API6D,HOV,W/W, A/G, TRU,BOL,2IN 600 |
| 5 | BALL API6D,HOV,F/F, A/G, TRU,BOL,FIR,4,600 |
| 6 | BALL API6D,HOV,W/W, U/G,TUR,BOL,4IN 600 |
| 7 | 4\\"x ANSI 600# F/F BS-1873 GLOBE Valve |
| 8 | 2.375\\" OD x 0.218\\" WT ASTM A 333 Gr. 6 PIPE |
| 9 | 4.50\\" OD x 0.237\\" WT ASTM A 333 Gr. 6 PIPE |
| 10 | INSULATING MONOBLOCK JOINT,600,4IN |
| 11 | 4\\"x4\\" 600# equal Tee |
| 12 | 12\\"x12\\" 600# Cross bar equal Tee |
| 13 | 12\\"x2\\" X 600# Weld-o-let |
| 14 | 12\\"x4\\" X 600# Weld-o-let |
| 15 | 12\\" 600# 90 deg LR Bend |
| 16 | 4\\" 600# 90 deg LR Bend |
| 17 | 4\\" Spectacle Blind 600# F/F |
| 18 | 4\\" NRV ANSI-600# |
| 19 | 4\\" BLRF 600# |
| 20 | 2\\" WNRF 600# |
| 21 | 4\\" WNRF 600# |
| 22 | 12\\" WNRF 600# |
| 23 | 2\\" SWMG ANSI 600# |
| 24 | 4\\" SWMG ANSI 600# |
| 25 | 12\\" SWMG ANSI 600# |
| 26 | Fasteners for Flanges 2\\" x 600# (0.625\\" Dia. X 4.75\\" Length) |
| 27 | Fasteners for Flanges 4\\" x 600# ( 0.875\\" Dia. X 7.75\\" Length) - extended stud length for flanges with spectacle blind |
| 28 | Fasteners for Flanges 4\\" x 600# (0.875\\" Dia. X 6.50\\" Length) |
| 29 | Fasteners for Flanges 12\\" x 600# (1.25\\" Dia. X 9.75\\" Length) |
| 30 | 12 NPS (12.75\\" OD x 0.250\\"/ 0.281\\"/ 0.375\\"/ 0.438\\" WT) APL 5L Pipe: |
| 31 | 4 NPS 4.5\\" OD x 0.237\\"/0.337\\" WT ASTM A106/ A333/ A53 Pipe: |
| 32 | 4 NPS 4.5\\" OD x 0.237\\"/0.337\\" WT ASTM A106/ A333/ A53 Pipe: |
| 33 | 2 NPS (2.375\\" OD x 0.218\\"/ 0.344\\" WT) ASTM A106/ A333/ A53 Pipe: |
| 34 | 12\\", 600#/900#, F/F: |
| 35 | 12\\", 600#/900#, W/W: |
| 36 | 2\\", 600#/900#, W/W: |
| 37 | 4\\", 600#/900#, F/F |
| 38 | 4\\", 600#/900#, W/W: |
| 39 | 2\\", 600#/900#, F/F |
| 40 | 4\\" x 150#/300#/600#/900# Insulating Coupling Erection |
| 41 | 4\\" NB Pipe Joints RT: Inspection of welding by Digital Radiography (CR) |
| 42 | 2\\" NB Pipe Joints RT: Inspection of welding by Digital Radiography (CR) |
| 43 | 12\\" NB Pipe Joints RT: Inspection of welding by Digital Radiography (CR) |
| 44 | 12\\" NB - Double Cut Joint: Cutting (Hot/ Cold cutting) of portion of existing piping |
| 45 | Dismantling the existing under ground piping, locating, retrieving including excavating the proper trenches |
| 46 | PU /liquid epoxy Coating of under ground piping |
| 47 | External Painting of Piping/ Equipment |
| 48 | Supply of all materials, consumables, providing all equipment & resources for the complete activity of commissioning of Liquid Petroleum Gas Pipeline (LPG) including Mainline and Stations with proper pressurization of mainline and station piping with Nitrogen, batch pigging followed by vaporized LPG and effective line fill by pressurization of line fill LPG as per approved procedure and Specification requirement including providing expert services for vetting of commissioning procedure and presence of expert to guide & monitor the complete commissioning activities, providing all supervisory/expert services, other manpower and all resources for the execution of the complete service meeting with international practices and standards, observing all statutory and other governing rules & standards in all respect and as per the approved scheme and guidance/direction of Engineer - in - Charge. i) The offer shall be inclusive of supply of nitrogen, pig train, all consumables, taxes, duties as applicable and excluding GST. ii) IOCL's responsibility shall be limited to arrangement of a) Fire tender b) Ambulance c) Water supply d) Providing LPG in tanker truck and subsequently lining up of the pipeline system for LPG line fill.:12\\" |
| 49 | Excavation up to bottom level of pipe which is normally at 1.5 to 2 m depth for lengths upto 30m, removing the coating, creating access for carrying out hot-tapping operation, applying the coating again after completion of Hot-Tapping Works and backfilling the excavated trench with excavated earth along with additional appropriate quantity of soil (to be arranged by the contractor), compacting the backfilled earth and restoring to original level and condition with all labours,materials, tools and tackles, equipments etc. as directed by EIC / Site Engineer |
| 50 | 12.75\\" |
| 51 | Retrieval of cross country mild steel pipeline section by excavation up to bottom level of pipe which is normally at 1.5 to 2 m depth, by cutting at every 10 to 12 meters by suitable safe method as approved by EIC / Site Engineer (pipe to be cut near to old girth weld of pipe and at some places cutting may be required at lesser length as per site requirement), removal of pipes from trench, loading, unloading and transportation to owner's installation with all labours, vehicles, tools and tackles, equipment as directed by EIC / Site Engineer including backfilling of excavated trench with excavated earth along with additional appropriate quantity of soil (to be arranged by the contractor) after removal of pipe, compacting the backfilled earth and restoring to original level and condition. |
| 52 | 12.75\\" |
| 53 | 12” Double Double Tandem Line Stop Operation With Temporary Bypass Line: Mobilization of Equipment’s, Hot Tapping/stopple machine, Cold cutting machine, sandwich valves, welding machine & consumables, cutter housing, stopple housing, stopple head, stopple cutter, pilot drill, cutter holder, Lock O-Ring plugs, LOR plug holder, required skilled, semiskilled, unskilled manpower, including Supply and Delivery of Line stopple fittings, Line Stopple Plug with scarfed nipple/Lock O-Ring plugs, Hot Tap bypass fitting, Hot Tap Plug with Scarfed Nipple/Lock O-Ring, Buna N Sealing Elements, 2\\" pressure equalization fittings, Lock O-Ring plugs, Sealing elements, 4” N2 gas bag fittings, guide bar, Blind Flanges, other tools, fixtures of 600# for 8 nos. hot tap/stoppling, fabrication/creation & pre-testing of temporary bypass line at both ends with double-double Tandem stopple with temporary bypass and hook-up with newly laid HDD line at both ends, with all accessories, fittings, flanges, gaskets, fasteners, blind flanges etc. required to complete the job, in line with enclosed tender specification and drawing, cleaning and removal of the coating if required, installation of the cutter housing, carrying out hot tapping, stoppling, welding, radiography of weld joints etc. Hot tapping and insertion of the stopple plug and blocking flow in the pipeline section for required duration including operation of sandwich valve etc. to facilitate flushing/purging operation, installation of LOR plug, supply of N2 for testing, air bleeding and filling the section with product and welding of end cap. Clearing the area, machines, tools & tackles etc., completing the work in all respect with all materials, consumables, tools, tackles, labour etc. to restore normal operation in line with specification of hot tapping given in Work specifications & as per tender drawings under close supervision and as per the direction of the Site-Engineer / Engineer-in-charge.Scope of supply:1. 12”x12”x600# Line stopple fittings with 12”x600# LOR Flange, 12” CAM LOR Plug, Blind flange, gasket & set of fasteners – 08 Nos2. 12”x4”x600# Gas bag Fittings with 4”x600# LOR Flange, 4” LOR Plug, Blind flange, gasket & set of fasteners – 04 Nos3. 12”x2”x600# Pr. Equalization Fittings with 2”x600# TOR Flange, 2” TOR |
| 54 | Civil Works: Pipe pedestals, Valve Chamber, Water Tank |
| 55 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed by the Engineer-in-Charge : |
| 56 | In all kinds of soil |
| 57 | Providing and laying in position cement concrete of specified grade at all depths including ramming & shuttering etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer: |
| 58 | 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources] |
| 59 | Providing and laying structural reinforced cement concrete work (1:1.5:3) conforming to IS:456 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) at all heights and depth for construction of foundations, beams, columns, staircases, chajja,lintels, balconies, shelves, plain window sills, roof slabs, facia, canopies, fins, porch, water tank etc. including providing centering, shuttering, staging, scaffolding, form work etc compacting with mechanical vibrator, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. (Payment for Reinforcement shall be made as per relevant item of SOR). |
| 60 | a) All work up to plinth level |
| 61 | b) In superstructure at all floors up to floor five level, |
| 62 | Steel reinforcement for R.C.C. workincluding initial straightening of coiled/uncoiled bars, removal of loose rust, cutting, bending to correct size & shape, binding with 18 gauge G.I. wire at each intersection and placing at any position, at any height and depth complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. : Thermo-Mechanically Treated bars of grade Fe-500 D or more |
| 63 | Supplying and filling coarse sand under floors, in foundations and plinth including cost-of sand, royalty, transportation, loading , unloading, spreading in layers not exceeding 20 cm., watering, ramming, compacting, dressing and levelling etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. |
| 64 | Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provision for lifting arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. |
| 65 | Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cutting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including preparation of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint \\"EPILUX 155 High Build Enamel over a coat of \\"EPILUX 610\\" Primer of M/s BERGER or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of concrete work). |
| 66 | Pumping out water caused by springs, tidal or river seepage,...Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the l |
| 67 | Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 laid to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. |
| 68 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. [Note: Unit \\"KG\\" shall mean \\"PER BAG OF 50 KG OF CEMENT\\"]. |
| 69 | Cement mortar 1:4 (1 cement : 4 coarse sand)Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 70 | Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:2800 (Part-I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment, tools, plants & machineries required for the job, all complete as per directions of the Engineer-in-Charge, up to 90 metre depth below ground level : |
| 71 | 300 mm diameter |
| 72 | Supplying, assembling, lowering and fixing in vertical position in bore well, Un-plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per directions of the Engineer-in-Charge : |
| 73 | 200 mm nominal size diameter |
| 74 | Supplying, assembling, lowering and fixing in vertical position in bore well Un-plasticized P.V.C. medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per directions of the Engineer-in-Charge : |
| 75 | 200 mm nominal size diameter |
| 76 | Gravel packing in tubewell construction in accordance with IS:4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per directions of the Engineer-in-Charge. |
| 77 | Development of tube well in accordance with IS:2800 (Part-I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and directions of the Engineer-in-Charge. [Note: Unit \\"H\\" shall mean \\"PER HOUR\\"]. |
| 78 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of : |
| 79 | 200 mm clamp |
| 80 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS:2800 (Part-I), including necessary bolts & nuts of required size complete. : |
| 81 | 200 mm clamp |
| 82 | Providing and fixing Bail plug/ Bottom plug of required diameter to the bottom of pipe assembly of tubewell as per IS:2800 (Part-I) : |
| 83 | 200 mm diameter |
| 84 | Supplying, providing, installation, testing & commissioning of sub-mersible pump-cum-motor of approved make capable of delivering 650 Litre Per Minute (LPM) to required head with starter, wiring from starter to motor and incoming feeder to starter including pipe with all attachment complete in all respects inclusive of cost of all labour, materials, tools, tackles, etc. as per drawings, specifications and directions of the Engineer-in-Charge :15 HP |
| 85 | Installation of Infrared HYDROCARBON DETECTORS (point type / open pathtype), terminating the cables at field and control panel / RTU end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, canopy, cement concrete, painting, GI wire etc.(excluding supply of the Hydrocarbon detector) complete in all respectsas per specifications. |
| 86 | Supply of Pressure Indicators (PI) of the range 0 to 100 Kg / Cm2 as per the technical specifications attached in the Tender. |
| 87 | Electrical Items |
| 88 | Supply of Solid State Diode Decoupling Device (min 5 kA @ 30 cycles) of approved make including required length of cable as per specifications |
| 89 | Supply of Surge Arrestors of approved make including required length of cable & as per specifications for protection of insulating couplings. Spark Gap Surge Arrestor for above ground and under ground suitable for 100 kA lightening Impulse Current (10/350 micro s), rated spark over voltage <= 1.25 kV in flameproof weatherproof enclosure Ex d IIC, IP 66 with connecting cable (EXFS 100 KU of Dehn or eq.) |
| 90 | Solid State Decoupling Device: Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge. |
| 91 | Surge Diverter/Spark Gap Surge Arrestor: Installation of surge arrestors including terminating the cables, testing & commissioning of surge arrestors etc. all complete with required material as per specification and directions of Site Engineer / Engineer-in-Charge. |
| 92 | Supply of Zn Grounding cells (with prepackaged backfill material) including required length of cable (minimum 10 m) of approved make & as per specification in accordance with latest revision of drawing no. 9200-99900-404-611-01 (STD-570-01) |
| 93 | Gounding Cell : Installation of grounding cells including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of grounding cell etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in-Charge. |
| 94 | Cable Marker Supply, erection and installation of MS cable markers; including excavation,installation of the markers,cement concrete grouting, back-filling etc. required as per drawings, specifications and directions of the Site Engineer,including the cost of all materials, labour,tools etc. complete in all respects as per the directions of Site Engineer / Engineer-in-Charge. |
| 95 | Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.: Flameproof Type E (With Ingress Protection IP:55) as per specification |
| 96 | Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.: Flameproof Type DMV (With Ingress Protection IP:55) as per specification |
| 97 | Supply and Installation of prefabricated CS corrosion coupon with 1 sq. cm bare metal with 2 numbers 4 sq. mm lead of minimum 10 m long lead in a sdistance of 0.5 m from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion couponf are to be installed with specified test lead points for which prior apporval to be obtained from owner. The item also incluseds supply, installation, laying & termination of all CU cables of required length (as per site condition) and size as mentioned in the standard drawing, toggle switch, cable glands and lugs etc. , complete in all respect as per the direction and specification detailed in the documetn complete with all tools , takles & other necessary requirement for preparation of the coupon . The work complete in all respect shall include supply of all the labours, tols etc. compete as per the direction of site engineer/engineer in charge. |
| 98 | Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% : AL,3CX10 mm²,A2XFY |
| 99 | Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40% : AL,3.5CX50 mm²,A2XFY |
| 100 | Supply of the flameproof (Ex'd) and weatherproof (Minimum IP-65) Distribution Boards (with Spares) made up of Cast Alluminium Alloy LM-6 with 125 A, TPN busbar, 01 no. 100 Ampere, 4 Pole MCCB suitable for termination of cable of size up to 3.5Cx50 sqmm, Aluminium Armoured cable. 01 additional spare entry suitable for 3.5CX50sqmm cable size shall be provided, which shall be plugged with flameproof and weatherproof entry plug. 09 Nos. 32A, 3 Pole/TPN MCBs suitable for termination of 3C x 10 sq.mm., Armoured cable, Breaking capacity of MCB shall be 10 kA for 1 Sec and shall be C-curve application suitable for motor duty. It shall be certified for application in Zone-I, Gas Group IIA & IIB, Temp class T3 and shall be of approved make as mentioned in the technical specifications. The item includes supply of flame proof double compression cable glands of nickel plated brass material for each cable entry 01 no. for cable entry of size up to 3.5C x 50 sq.mm., 02 no for 3.5 C x 25 Sq mm cable, 09 no. for 3Cx10 sqmm, Aluminium armoured cable. Cable dimensions shall be provided at drawings approval stage. Supply shall be as per technical specifications of flameproof DB attached with supply specifications. |
| 101 | Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge |
| 102 | Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD upto 20 mm |
| 103 | Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: Power cables LT : OD above 20 mm and upto 40 mm |
| 104 | 415 V AC 3 phase / 230 V AC single phase motors - Connection and testing of 415 V AC 3 phase / 230 V AC single phase motors (including space heaters/thermistors wherever provided) / AC/DC Actuators including execution of terminal connection of control and power cables, earthing of the motor/actuator/ connecting the thermistor, installing the controller in LT panel, earthing the motor frame, armour etc. as per the drawings, erection manuals, and as per directions of Site Engineer. Job complete in all respects including the cost of supplying and installation of all the required FLP/WP cable glands, reducers, adapeters, end lugs, GI earthing wire / strips, labour, tools, materials, etc., as required in all respects for all types of motors/heaters/thermistors/actuators etc.: Capacity upto and including 1 KW |
| 105 | Erection, installation including within site transportation, testing and commissioning of 415 V , Flameproof distribution boards (FLP-DB) under scope of supply of bidder, assembling as required, installation on the already made foundation channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming power & control cable/ bus duct connection including making holes for cable entries as required as per drawing, specifications and directions of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all power , control cables, installation of thermistor controller, internal wiring, earthing of FLP-DB panels, supply of cable glands etc. complete as per cable schedule, drawings etc. |
| 106 | Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push button control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete.and as per specifications and directions of site engineer/ Engineer-in-Charge. |
| 107 | Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge |
| 108 | Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. |
| 109 | EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect:40 mm X 5 mm G.I. earthing strip |
| 110 | EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: GI wire (8 SWG) |
| 111 | Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge: 37 mm |
| 112 | LT CABLE END TERMINATION FOR ARMOURED PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSIONFLAME PROOF TYPE BRASS GLANDING (INCLUDING COST OF GLANDS & LUGS) : Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approvedequivalent), wherever specified, providing aluminium lugs, crimping/ soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-charge : 3-1/2 x 50 sqmm |
| 113 | T&I Items: Service Items |
| 114 | Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge |
| 115 | Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: OD upto 20 mm |
| 116 | Carrying out the instrumentation and control system jobs on the already erected actuator assembly of motor operated valves (MOV)by making the necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc. |
| 117 | T&I Items: Composite Items |
| 118 | SAND SUPPLY & FILLING : Supplying and spreading of approved quality,fine, dry /river sand in cable trenches as per drawings, specifi- cations and directions of the Site Engineer, including the cost of all material, transport, load and lift charges, labour,tools etc. complete in all respects. |
| 119 | BRICK SOLING : Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protection; as per drawings, specification and direction of the Site Engineer including the cost of all brick,sand and other materials,tools,labour, load and lift charges etc.complete in all respects. |
| 120 | BRICK SOLING : Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protection; as per drawings, specification and direction of the Site Engineer including the cost of all brick,sand and other materials,tools,labour, load and lift charges etc.complete in all respects. for 6'' Tiles 200mm Height |
| 121 | Installation, testing and commissioning of Pressure Indicator (PI) of various ratings as per drawings, recoomendations of OEM and directions of Engineer in-charge/ Site engineer |
| 122 | T&I Items: Supply Items |
| 123 | CONTROL CABLE - SIZE: 12C X1.5 SQMM ( SAP CODE- 7778320354) |
| 124 | TRIAD CABLE - Size:1 TriadX1.5 sqmm [ SAP Code: 7780740534] |
| 125 | POINT TYPE DETECTOR - IR Based explosion proof & weather proof (Point type) Hydrocarbon detectors along with all mounting & other accessories as per tender specifications. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender