Tender For Maintenance Of Rws Schemes Under Gomati District Tripura/ Sh- maintenance Of Pvc, Ci, Di, & Gi Pipeline Including Extension And Washing Of Pipeline, Repairing Of Leakage, Fitting Fixing Of Sluice Valves Etc. In Different Water Supply Schem
Tender Overview
Project Description
Tender for Maintenance Of Rws Schemes Under Gomati District Tripura/ Sh- maintenance Of Pvc, Ci, Di, & Gi Pipeline Including Extension And Washing Of Pipeline, Repairing Of Leakage, Fitting Fixing Of Sluice Valves Etc. In Different Water Supply Schemes In Amarpur Rd Block Under Dws Sub-Division, Amarpur During The Year 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | \\"Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge. i)90 mm OD |
| 2 | ii)110 mm OD |
| 3 | iii)140 mm OD |
| 4 | Making road crossing by horizontal boring for smooth laying of UPVC/CI/DI/GI pipes etc. of required dia complete as per specification and the direction of the Er. -in -Charge A) By manual means. |
| 5 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. A) For UPVC pipes in new work .a. In all kinds of soil. i) For pipes not exceeding 90 mm dia |
| 6 | For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 7 | Providing, fixing and laying rigid UPVC pipes conforming to IS: 4985 jointing with couplers of same class conforming to IS: 10124(Pt-II) with solvent cement conforming to IS: 14182 including testing of joints complete (but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class-3(working pressure 6.0kg/cm2 i)40 mm OD |
| 8 | ii) 90 mm OD |
| 9 | iii) 110 mm OD |
| 10 | iv) 140 mm OD |
| 11 | Providing and fixing GI pipes of Medium class as per IS: 1239 with latest amendment complete with GI fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer-in-charge.A. External work.i) 80 mm dia nominal bore |
| 12 | ii) 100 mm dia nominal bore |
| 13 | iii) 150 mm dia nominal bore |
| 14 | Charge for dismantling PVC/HDPE pipe after necessary excavation of earth in/c washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required in layers not exceeding 200 mm in depth in/c consolidating each deposited layer by ramming , watering, etc. complete as per specification and direction of the Er. -in -Charge.i) 90 mm dia |
| 15 | ii) 110 mm dia |
| 16 | iii) 140 mm dia |
| 17 | Clearing of deposited iron in side of laying PVC pipe line in different dia (90/110/140 mm dia) in/c excavating trenching for 100 mtr lead pipe line of required width and depth after 20 mtr distance and 3.00 mtr long in every 100 mtr clearing through UPVC coil pipe and laying the same with necessary couplers and solvent cement etc. ( solvent cement and coupler etc. will be issued by the dept. at free of cost). |
| 18 | Clearing of deposited iron in side of laying CI pipe line in different dia (80/100/125/150 mm dia) and dismantaling old CI pipe in/c trenching , refilling etc. for 100 mtr lead pipe line of required width and depth cutting earth in 25 mtr distance and 12.00 mtr long in each i.e. 36 mtr trenches cutting for every 100 mtr pipe iron through UPVC coil pipe after clearing , washing, laying the same with rubber gasket , pipe lead joints as per direction of Engineer - in - charge ( pig lead will be issued by the dept. at free of cost and rubber gasket and T & P arrange by the agency). |
| 19 | Providing and laying of flexible PVC pipe (conforming to IS: 7634) complete including earth work as per specification and direction of the Engineer-in-charge(cost of fittings will be paid separately).i) 15 mm dia |
| 20 | ii) 20 mm dia |
| 21 | iii) 25 mm dia |
| 22 | Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i)90 mm dia |
| 23 | ii)110 mm dia |
| 24 | iii)140 mm dia |
| 25 | Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i)90 x 90 mm dia |
| 26 | ii)110 x 110 mm dia |
| 27 | iii)140 x 140 mm dia |
| 28 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i) 40 mm dia |
| 29 | ii) 90 mm dia |
| 30 | iii) 110 mm dia |
| 31 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge . i)110 x 90 mm dia |
| 32 | ii)140 x 110 mm dia |
| 33 | iii)140 x 90 mm dia |
| 34 | \\"Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.\\" i)90 mm dia |
| 35 | ii)110 mm dia |
| 36 | iii)140 mm dia |
| 37 | Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i) 90 mm dia |
| 38 | ii)110 mm dia |
| 39 | iii)140 mm dia |
| 40 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.(i) 15 mm dia |
| 41 | (ii) 20 mm dia |
| 42 | (iii) 25 mm dia |
| 43 | (iv) 40 mm dia |
| 44 | Providing and fixing G.I. Socket as per CPWD specification and direction of the Engineer - in- Charge.(i) 15 mm dia |
| 45 | (ii) 20 mm dia |
| 46 | (iii) 25 mm dia |
| 47 | (iv) 40 mm dia |
| 48 | Providing and fixing GI union as per CPWD specification and direction of the Engineer - in- Charge.(i) 15 mm dia |
| 49 | (ii) 20 mm dia |
| 50 | (iii) 25 mm dia |
| 51 | (iv) 40 mm dia |
| 52 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i. 20 x 15 mm dia |
| 53 | ii. 25 x 15 mm dia |
| 54 | iii. 40 x 15 mm dia |
| 55 | iv. 40 x 25 mm dia |
| 56 | Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including borring and tapping the main as per CPWD specification and direction of the Engineer - in- Charge.i) 10 mm nominal bore |
| 57 | (ii) 15 mm nominal bore |
| 58 | Providing and fitting fixing PVC / Plastic Bib cock conforming to IS: 9763 in hydrant points at different location as per specification and direction of the Engineer - in- Charge.i) 15 mm dia PVC / Plastic Bib cock |
| 59 | Providing and fixing C.I Bib cock(long handle) as per specification and direction of the Engineer - in- Charge.i) 15 mm dia |
| 60 | Providing and fixing GI full way valve as per CPWD specification and direction of the Engineer - in- Charge.i) 15 mm dia |
| 61 | ii) 20 mm dia |
| 62 | iii) 25 mm dia |
| 63 | iv) 40 mm dia |
| 64 | Providing and fixing G.I. Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i. 40 x 40 x 15 mm dia |
| 65 | ii. 40 x 40 x 25 mm dia |
| 66 | iii. 40 x 40 x 20 mm dia |
| 67 | Providing and laying flanged C.I standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS: 1538 as per CPWD specification and direction of the Engineer - in - charge.i)Upto 300 mm dia. |
| 68 | Providing and fitting fixing of GI flange (10 mm wall thickness) by welding with GI/MS pipe and placing position as per specification and the direction of the Engineer-in-charge.(i) 80 mm dia |
| 69 | (ii) 100 mm dia |
| 70 | (iii) 125 mm dia |
| 71 | (iv) 150 mm dia |
| 72 | Providing and fixing GI Nipple of medium class as per CPWD specification and direction of the Engineer-in-charge.(i) 15 mm dia 150 mm long |
| 73 | (ii) 20 mm dia 150 mm long |
| 74 | (iii) 25 mm dia 150 mm long |
| 75 | Providing and fitting fixing of C.I. Sluice valve spandle with thread as per direction of the Engineer-in-charge(i) 150 mm dia |
| 76 | (ii) 100 mm dia |
| 77 | Providing and fixing of C.I. Sluice valves(with cap) complete with bolts, nuts, rubber insertions etc.(the tail pieces if required will be paid separately) as per CPWD specification and direction of the Engineer-in-charge. (A) 80 mm dia, PN-1.6 |
| 78 | (B) 100 mm dia, PN-1.6 |
| 79 | (C) 125 mm dia, PN-1.6 |
| 80 | (D) 150 mm dia, PN-1.6 |
| 81 | Charges for cutting DI pipe with Mechanical cutter as per CPWD specification and direction of the Engineer-in-charge.(i) 100 mm dia |
| 82 | (ii) 150 mm dia |
| 83 | Providing and fitting fixing of GI tyton collar with rubber gasket fitted with MS flat and MS square bar at both ends in/c. nuts & bolts, washer & paiting with anti corrosive black bitermestic paint etc. complete.(i) 80 mm dia |
| 84 | (ii) 100 mm dia |
| 85 | (iii) 125 mm dia |
| 86 | (iv) 150 mm dia |
| 87 | Labour charge for disconnection of domestic water supply connection, hydrant etc. from old pipe line and also reconnection the same to the line in/cl. necessary trenching, boring, tapping the main etc. complete in all respect as per specification and the direction of the Engineer-in-charge. |
| 88 | Charges for making hole by drilling and making thread by thread bit in the CI/DI pipe as per specification and direction of the Engineer-in-charge.(i) 10 mm dia nominal bore |
| 89 | Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm as per relevant IS specification and direction of Engineer-in-charge.(i) 150 mm dia |
| 90 | Providing and fitting fixing MS clamp for hose pipes with nuts & bolts complete as per relevant IS specification and direction of Engineer-in-charge.(i) 150 mm dia |
| 91 | Providing and fitting fixing MS foot valve as per relevant IS specification and the direction of the Engineer-in-charge.(i) 150 mm dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender