Drinking Water Supply and Sanitation Government Departments Closing in 4 days TDR #56767442

Tender For Maintenance Of Rws Schemes Under Gomati District Tripura/ Sh- maintenance Of Pvc, Ci, Di, & Gi Pipeline Including Extension And Washing Of Pipeline, Repairing Of Leakage, Fitting Fixing Of Sluice Valves Etc. In Different Water Supply Schem

Issued by Government Departments · Gomati, Tripura
Tender Value
11.13 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
4 days left
EMD
22277
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gomati → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Rws Schemes Under Gomati District Tripura/ Sh- maintenance Of Pvc, Ci, Di, & Gi Pipeline Including Extension And Washing Of Pipeline, Repairing Of Leakage, Fitting Fixing Of Sluice Valves Etc. In Different Water Supply Schemes In Amarpur Rd Block Under Dws Sub-Division, Amarpur During The Year 2026-27

BOQ

Name of Work:- Maintenance of RWS SCHEMES under Gomati District Tripura/ SH- Mtc. of PVC, CI, DI, & GI pipeline including extension and washing of pipeline, repairing of leakage, fitting fixing of sluice valves etc. in different water supply Schemes in Amarpur RD Block under DWS Sub-Division, Amarpur during the year 2026-27
Sl. No. Item Description
1\\"Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge. i)90 mm OD
2ii)110 mm OD
3iii)140 mm OD
4Making road crossing by horizontal boring for smooth laying of UPVC/CI/DI/GI pipes etc. of required dia complete as per specification and the direction of the Er. -in -Charge A) By manual means.
5Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. A) For UPVC pipes in new work .a. In all kinds of soil. i) For pipes not exceeding 90 mm dia
6For pipes exceeding 90 mm dia but not exceeding 300 mm dia
7Providing, fixing and laying rigid UPVC pipes conforming to IS: 4985 jointing with couplers of same class conforming to IS: 10124(Pt-II) with solvent cement conforming to IS: 14182 including testing of joints complete (but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class-3(working pressure 6.0kg/cm2 i)40 mm OD
8ii) 90 mm OD
9iii) 110 mm OD
10iv) 140 mm OD
11Providing and fixing GI pipes of Medium class as per IS: 1239 with latest amendment complete with GI fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer-in-charge.A. External work.i) 80 mm dia nominal bore
12ii) 100 mm dia nominal bore
13iii) 150 mm dia nominal bore
14Charge for dismantling PVC/HDPE pipe after necessary excavation of earth in/c washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required in layers not exceeding 200 mm in depth in/c consolidating each deposited layer by ramming , watering, etc. complete as per specification and direction of the Er. -in -Charge.i) 90 mm dia
15ii) 110 mm dia
16iii) 140 mm dia
17Clearing of deposited iron in side of laying PVC pipe line in different dia (90/110/140 mm dia) in/c excavating trenching for 100 mtr lead pipe line of required width and depth after 20 mtr distance and 3.00 mtr long in every 100 mtr clearing through UPVC coil pipe and laying the same with necessary couplers and solvent cement etc. ( solvent cement and coupler etc. will be issued by the dept. at free of cost).
18Clearing of deposited iron in side of laying CI pipe line in different dia (80/100/125/150 mm dia) and dismantaling old CI pipe in/c trenching , refilling etc. for 100 mtr lead pipe line of required width and depth cutting earth in 25 mtr distance and 12.00 mtr long in each i.e. 36 mtr trenches cutting for every 100 mtr pipe iron through UPVC coil pipe after clearing , washing, laying the same with rubber gasket , pipe lead joints as per direction of Engineer - in - charge ( pig lead will be issued by the dept. at free of cost and rubber gasket and T & P arrange by the agency).
19Providing and laying of flexible PVC pipe (conforming to IS: 7634) complete including earth work as per specification and direction of the Engineer-in-charge(cost of fittings will be paid separately).i) 15 mm dia
20ii) 20 mm dia
21iii) 25 mm dia
22Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i)90 mm dia
23ii)110 mm dia
24iii)140 mm dia
25Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i)90 x 90 mm dia
26ii)110 x 110 mm dia
27iii)140 x 140 mm dia
28Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i) 40 mm dia
29ii) 90 mm dia
30iii) 110 mm dia
31Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge . i)110 x 90 mm dia
32ii)140 x 110 mm dia
33iii)140 x 90 mm dia
34\\"Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.\\" i)90 mm dia
35ii)110 mm dia
36iii)140 mm dia
37Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i) 90 mm dia
38ii)110 mm dia
39iii)140 mm dia
40Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.(i) 15 mm dia
41(ii) 20 mm dia
42(iii) 25 mm dia
43(iv) 40 mm dia
44Providing and fixing G.I. Socket as per CPWD specification and direction of the Engineer - in- Charge.(i) 15 mm dia
45(ii) 20 mm dia
46(iii) 25 mm dia
47(iv) 40 mm dia
48Providing and fixing GI union as per CPWD specification and direction of the Engineer - in- Charge.(i) 15 mm dia
49(ii) 20 mm dia
50(iii) 25 mm dia
51(iv) 40 mm dia
52Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i. 20 x 15 mm dia
53ii. 25 x 15 mm dia
54iii. 40 x 15 mm dia
55iv. 40 x 25 mm dia
56Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including borring and tapping the main as per CPWD specification and direction of the Engineer - in- Charge.i) 10 mm nominal bore
57(ii) 15 mm nominal bore
58Providing and fitting fixing PVC / Plastic Bib cock conforming to IS: 9763 in hydrant points at different location as per specification and direction of the Engineer - in- Charge.i) 15 mm dia PVC / Plastic Bib cock
59Providing and fixing C.I Bib cock(long handle) as per specification and direction of the Engineer - in- Charge.i) 15 mm dia
60Providing and fixing GI full way valve as per CPWD specification and direction of the Engineer - in- Charge.i) 15 mm dia
61ii) 20 mm dia
62iii) 25 mm dia
63iv) 40 mm dia
64Providing and fixing G.I. Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i. 40 x 40 x 15 mm dia
65ii. 40 x 40 x 25 mm dia
66iii. 40 x 40 x 20 mm dia
67Providing and laying flanged C.I standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS: 1538 as per CPWD specification and direction of the Engineer - in - charge.i)Upto 300 mm dia.
68Providing and fitting fixing of GI flange (10 mm wall thickness) by welding with GI/MS pipe and placing position as per specification and the direction of the Engineer-in-charge.(i) 80 mm dia
69(ii) 100 mm dia
70(iii) 125 mm dia
71(iv) 150 mm dia
72Providing and fixing GI Nipple of medium class as per CPWD specification and direction of the Engineer-in-charge.(i) 15 mm dia 150 mm long
73(ii) 20 mm dia 150 mm long
74(iii) 25 mm dia 150 mm long
75Providing and fitting fixing of C.I. Sluice valve spandle with thread as per direction of the Engineer-in-charge(i) 150 mm dia
76(ii) 100 mm dia
77Providing and fixing of C.I. Sluice valves(with cap) complete with bolts, nuts, rubber insertions etc.(the tail pieces if required will be paid separately) as per CPWD specification and direction of the Engineer-in-charge. (A) 80 mm dia, PN-1.6
78(B) 100 mm dia, PN-1.6
79(C) 125 mm dia, PN-1.6
80(D) 150 mm dia, PN-1.6
81Charges for cutting DI pipe with Mechanical cutter as per CPWD specification and direction of the Engineer-in-charge.(i) 100 mm dia
82(ii) 150 mm dia
83Providing and fitting fixing of GI tyton collar with rubber gasket fitted with MS flat and MS square bar at both ends in/c. nuts & bolts, washer & paiting with anti corrosive black bitermestic paint etc. complete.(i) 80 mm dia
84(ii) 100 mm dia
85(iii) 125 mm dia
86(iv) 150 mm dia
87Labour charge for disconnection of domestic water supply connection, hydrant etc. from old pipe line and also reconnection the same to the line in/cl. necessary trenching, boring, tapping the main etc. complete in all respect as per specification and the direction of the Engineer-in-charge.
88Charges for making hole by drilling and making thread by thread bit in the CI/DI pipe as per specification and direction of the Engineer-in-charge.(i) 10 mm dia nominal bore
89Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm as per relevant IS specification and direction of Engineer-in-charge.(i) 150 mm dia
90Providing and fitting fixing MS clamp for hose pipes with nuts & bolts complete as per relevant IS specification and direction of Engineer-in-charge.(i) 150 mm dia
91Providing and fitting fixing MS foot valve as per relevant IS specification and the direction of the Engineer-in-charge.(i) 150 mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56767442
AUTHORITY Government Departments
TENDER VALUE 11.13 Lakhs
LAST DATE 07-08-2026
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Tender for Maintenance Of Rws Schemes Under Gomati District Tripura/ Sh- maintenance Of Pvc, Ci, Di, & Gi Pipeline Including Extension And Washing Of Pipeline, Repairing Of Leakage, Fitting Fixing Of Sluice Valves Etc. In Different Water Supply Schemes In Amarpur Rd Block Under Dws Sub-Division, Amarpur During The Year 2026-27
Basic Detail
Tender No 30/DNIeT/EE/DWS/AMP/2026-27
Bidding Type Tender
Location
City Gomati
State Tripura
Key Dates
Publish Date 31 Jul 2026
Submission Date 07 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 11.13 Lakhs
Tender Fee 1000
EMD 22277
Exemption Not Available
Document List
9123f1e2-9657-47d4-91b4-b459c40dbf3b.html
BOQ_76470.xls
FDNIeT30.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

9123f1e2-9657-47d4-91b4-b459c40dbf3b.html

xls

BOQ_76470.xls

pdf

FDNIeT30.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders