Tender For Improvement Of Cricket-Cum-Football Field, Cricket Practice Field, Basketball Court, Volleyball Court And Archery Court Of District Stadium, Boudh.
Tender Value
16.35 Crore
Estimated cost
Bid Submission
13 Aug 2026
12 days left
EMD
16.36 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Boudh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Cricket-Cum-Football Field, Cricket Practice Field, Basketball Court, Volleyball Court And Archery Court Of District Stadium, Boudh.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKProviding and injecting chemical emulsion for pre - constructional anti- termite treatment as per IS specification and creating a chemical barrier in bottom and sides of foundation trenches, top- surface of plinth filing junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and cables etc. complete using approved quality of chemical emulsion of requisite quantity prescribed by the manufacturer as directed by the Engineer-in-charge including cost o all materials and labour taxes etc. complete. (indemnity bond for warranty for 7 years to be furnished)Cricket Cum Football Ground |
| 2 | Cricket Practice Pitch & Warm-Up Area |
| 3 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cricket Cum Football Ground |
| 4 | Cricket Practice Pitch & Warm-Up Area |
| 5 | Basketball Court |
| 6 | Volley Ball Court |
| 7 | Archery Court |
| 8 | Providing and Laying & Compacting 4-9mm stone aggregate Spreading in uniform layersCricket Cum Football Ground |
| 9 | Supplying and stacking & laying of root zone sand as per USGA standard at site including royalty and carriageCricket Cum Football Ground |
| 10 | Supplying and stacking at site Organic matter (turf booster/equ.) from approved source.Cricket Cum Football Ground |
| 11 | Spreading of Organic matter (turf booster/equ.) in required thickness as per direction of officer-in-chargeCricket Cum Football Ground |
| 12 | Supply and Mixing basal fertilizer in the required proportion specified or directed by the Officer-in-charge.Cricket Cum Football Ground |
| 13 | Excavation of Trenches for Drainage (250 x 300 mm) and shifting of soil out side of stadium.Cricket Cum Football Ground |
| 14 | Providing and dibbling of good quality lawn of the specified species in lawn area, with clods broken completely, and removal of debris and unwanted materials and final saping to achieve desired levalBermuda TIFWAY419 Grass sprts varietyCricket Cum Football Ground |
| 15 | Cricket Practice Pitch & Warm-Up Area |
| 16 | FIELD DRAINAGEProviding and laying in trenches Upvc pipes conforming to IS 4984 1995 and specials of following outside diameter and class-1 to class-3 and jointing including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately)11Omm Upvc corrugated perforated pipeCricket Cum Football Ground |
| 17 | 160mmUPC Plain pipeCricket Cum Football Ground |
| 18 | Supplyingand laying of Geotextile (For Trenchs) 150 GSMCricket Cum Football Ground |
| 19 | PITCH CONSTRUCTIONSupply and laying fine Sand for pitch (9 nos)Cricket Cum Football Ground |
| 20 | Supplying of the cricket pitch with Balangir/ Boudh/ kala handi soil (Clay Granuale size not more than 12 mm ), in layers not exceeding 200 mm in depth including cost of watering ramming, drssing and levelling the top to proper lavel and gradiant cost of labour, convence, loading,unloading T&P, etc allcomplete as per the direction enginer In charge.Cricket Cum Football Ground |
| 21 | Grassing of Pitch including grass ( For 9 nos)Cricket Cum Football Ground |
| 22 | BOWLING RUN UPSupply of sandy Soil 200mm for bowling runup Cricket Cum Football Ground |
| 23 | Construction of bowling Run- ups for main pitches, desired level as per countour and sandy loam measureing 15.24x18 meters(3 nos ) for main pitches each at two ends of pitch squre at North - South direction.Cricket Cum Football Ground |
| 24 | SPRINKLER SYSTEMDesign, Supply, Installation, Testing and Commissioning of Fully Automatic Underground Pop-up Sprinkler Irrigation System complete for the Football-cum-Cricket Field, as per the approved drawings, manufacturer's specifications, site conditions and the directions of the Engineer-in-Charge. The scope shall include preparation of hydraulic design and shop drawings; supply, installation, testing and commissioning of the complete irrigation system including uPVC pipelines, pop-up sprinklers with swing joints, automatic controller, solenoid valves, manual valves, valve boxes, disc filter, pumps (1 Working + 1 Standby, minimum 7.5 HP each), control panels, cables with conduits, fittings, clamps, NRVs, supports, excavation, backfilling, thrust blocks, flushing, trial run and all other accessories, consumables, labour, tools, testing and incidental works required for satisfactory and trouble-free operation of the irrigation system, complete in all respects.Approved Makes:-uPVC Pipes: Supreme / Finolex / AstralPop-up Sprinklers, Controller, Solenoid Valves, Rain Sensor & Irrigation Accessories: Toro (USA) / Rain Bird (USA) / Eqv.Swing Joints: Toro / Rain Bird / Eqv.PP/PVC Service Saddles & Ball Valves: Supreme (Italy) / SAB / Plasson / Eqv.Air Release Valve, QCV & Brass Fittings: Harit / Jain / Eqv.Valve Boxes: Pimtas / Eqv.Pumps: Grundfos / Xylem / Eqv.Disc Filter: Amaid / Azud / Eqv.Control Cables: Macrotherm / Paige / Eqv.Waterproof Wire Connectors: 3M / Toro / Eqv.Cricket Cum Football Ground |
| 25 | 5 YEARS MAINTAINANCE Maintenance of Football-cum-Cricket Field with Practice Pitch Turf: After planting and successful establishment of the turf grass, the Football-cum-Cricket Field with Practice Pitch Turf shall be maintained and manicured for the period as specified. The maintenance shall include irrigation (daily during summer, 2–3 times per week during winter, and as required during monsoon), mowing as required to maintain turf height of 25–30 mm for the football field and 10–15 mm for the cricket outfield throughout the maintenance period, application of balanced NPK fertilizers every 30 days, micronutrients every 2 months, fungicides, insecticides, herbicides and bio-organic fertilizers as required, weed control, pest management, aeration, scarifying (verticutting), top dressing, level correction, monthly drainage maintenance, cricket pitch preparation per month & before each match, divot repair, and all other operations necessary to maintain a healthy, dense, level and match-ready playing surface, complete in all respects as directed by the Engineer-in-Charge.Cricket Cum Football Ground |
| 26 | EQUIPMENTSCricket Sight Screen ( 6m X 6m )Cricket Cum Football Ground |
| 27 | Pitch Protection CoverCricket Cum Football Ground |
| 28 | Water Removal Foam Roller ( 750mm Wide )Cricket Cum Football Ground |
| 29 | Score Board ( Standard Wood Finish in Matt Black. Complete with telegraph numbers )Cricket Cum Football Ground |
| 30 | Rope as Per StandardCricket Cum Football Ground |
| 31 | Supply of Pitch Cutter it consists of 163cc Petrol Engine, 4-Stroke Single Cylinder,Air Cooled system,3600 Rpm Speed of engine, 3.1 Litre Fuel tank,600 ml Oil Capacity, Cutting width 22”(558mm)and Cutting Height 2mm ~ 30mm. & follwing specification- HANDLE: Adjustable ergonomic handle, powder coated.CHASSIS: Mild steel 4mm CNC Laser Cut for accuracy. Powder coated PU paint giving anti rust, corrosion free longer lifeMATERIAL USED: Stainless Steel (SS) material used for crucial parts like, blade holder, blade adjustment knobs, grass reflectors, levers, and main cover, REAR ROLLER: Split Rear Roller Two piece Mild steel roller, with mud scrapper. FRONT ROLLER: Grooved aluminum running on sealed bearings with mud scrapper.DRIVE CLUTCH: Handle mounted, lever operating tight and loose V belt via a cable. Idler provided for quick belt and chain adjustment.CUTTER CLUTCH: Handle mounted lever operating tight and loose V belt via a cable. Idler provided for quick belt and chain adjustmentGRASS CATCHER: Front Large capacity with fiber molded with reinforced steel frame.SIZE(Inch): Box 1: 40” x 38” x 30” , Box 2: 27.5” x 19.5” x 14.5” , Box 3: 32” x 19” x 17”Total Weight: 210KgCricket Cum Football Ground |
| 32 | Supply of Brush cutter Single Cylinder,Engine Type 2 – Stroke, Air Cooled 43.2cc Displacement, 1.25 Kw / 6500 RPM Max Power ,Carburetor Diaphragm Type1.2 L Fuel TankCapacity and 7.8 kg Net Weight. Cricket Cum Football Ground |
| 33 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper positionR.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.For Beyond 1.5 M to 4.5M Depth150 KLD Under Ground Tank |
| 34 | Ground FloorCricket Cum Football Ground |
| 35 | Basketball Court |
| 36 | Volley Ball Court |
| 37 | Archery Court |
| 38 | R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shades and chajjas up to 4.3Mtr. Height.Ground Floor150 KLD Under Ground Tank |
| 39 | R.C.C. walls and fins including attached pillasters.(For Depth 1.5m to 4.5m + Ground Floor)/2150 KLD Under Ground Tank |
| 40 | RCC DRAIN(A) R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.Ground FloorCricket Cum Football Ground |
| 41 | Basket Ball Court Drain |
| 42 | Volley Ball Court Drain |
| 43 | Archery Court Drain |
| 44 | (B)R.C.C. Pre Cast Perforated Cover SlabGround FloorCricket Cum Football Ground |
| 45 | Basket Ball Court Drain |
| 46 | Volley Ball Court Drain |
| 47 | Archery Court Drain |
| 48 | (C)R.C.C. WallGround FloorCricket Cum Football Ground |
| 49 | Basket Ball Drain |
| 50 | Volley Ball Court Drain |
| 51 | Archery Court Drain |
| 52 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment).Ground FloorCricket Cum Football Ground |
| 53 | Basketball Court |
| 54 | Basket Ball Court Drain |
| 55 | Volley Ball Court |
| 56 | Volley Ball Court Drain |
| 57 | Archery Court |
| 58 | Archery Court Drain |
| 59 | (For Depth 1.5m to 4.5m + Ground Floor)/2150 KLD Under Ground Tank |
| 60 | Structural steel work of Rectangular hollow Section 100x50 of 4mm thick includinghoisting, fixing in position WeldedCricket Cum Football Ground |
| 61 | Basketball Court |
| 62 | Volley Ball Court |
| 63 | Archery Court |
| 64 | Providing and fixing of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Cricket Cum Football Ground |
| 65 | Basketball Court |
| 66 | Volley Ball Court |
| 67 | Archery Court |
| 68 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 69 | Basketball Court |
| 70 | Volley Ball Court |
| 71 | Archery Court |
| 72 | Providing and applying waterproofing treatment to roof including treatment of construction joints and cracks by pressure grouting, bore packing, formation of coving (50×50 mm), thorough surface preparation, and application of single component PU based liquid waterproofing membrane (Nitoproof 600PF or equivalent) in two coats to achieve minimum 1.5 mm dry film thickness, including 300 GSM geotextile separation layer and protective screed where specified, complete with all materials, labour, tools, curing and finishing as per specifications and direction of Engineer-in-Charge.Ground Floor150 KLD Under Ground Tank |
| 73 | Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and gravel mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge.(a)Upto 1.5mtr Depth150 KLD Under Ground Tank |
| 74 | Cricket Cum Football Ground |
| 75 | Basketball Court |
| 76 | Basket Ball Court Drain |
| 77 | Volley Ball Court |
| 78 | Volley Ball Court Drain |
| 79 | Archery Court |
| 80 | Archery Court Drain |
| 81 | (b)From 1.5mtr to 3.0mtr Depth |
| 82 | Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.Ground Floor150 KLD Under Ground Tank |
| 83 | Cricket Cum Football Ground |
| 84 | Basketball Court |
| 85 | Basket Ball Court Drain |
| 86 | Volley Ball Court |
| 87 | Volley Ball Court Drain |
| 88 | Archery Court |
| 89 | Archery Court Drain |
| 90 | Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge.Basketball Court |
| 91 | Volley Ball Court |
| 92 | Archery Court |
| 93 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.150 KLD Under Ground Tank |
| 94 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. Ground Floor150 KLD Under Ground Tank |
| 95 | Cricket Practice Pitch & Warm-Up Area |
| 96 | Basketball Court |
| 97 | Volley Ball Court |
| 98 | Archery Court |
| 99 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.From 1.5mtr to 4.5Mtr Depth150 KLD Under Ground Tank |
| 100 | Upto 1.5mtr DepthCricket Cum Football Ground |
| 101 | Basketball Court |
| 102 | Basket Ball Court Drain |
| 103 | Volley Ball Court |
| 104 | Volley Ball Court Drain |
| 105 | Archery Court |
| 106 | Archery Court Drain |
| 107 | Providing and laying 150 mm dia. R.C.C. pipe non-pressure NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:3 (1 cement : 3 fine sand) including testing of joints etc. complete :Cricket Cum Football Ground |
| 108 | Providing and laying 450 mm dia. R.C.C. pipe non-pressure NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:3 (1 cement : 3 fine sand) including testing of joints etc. complete :Cricket Cum Football Ground |
| 109 | Supplying, Deliver, stacking on site dust free stone aggregate of size 6-10 mm including loading & Unloading etc.complete. as directed by the engineer in charge/ consultant.Cricket Cum Football Ground |
| 110 | FOOTBALL EQUIPMENT (GOAL POST-1 PAIR,CORNER FLAG-1 SETFootball Goal Post (All As per FIFA Requirement for premier Tournament) Supply and installtion of Uprights & Crossbars made from 102mm x 112mm reinforced aluminium with double recess for flush fitting fixings. Reinforced welded aluminium corner joints for improved aesthetics and superior strength, with laser cut internal fixing for exceptionally accurate joints. Injection moulded toughened nylon net clips that won't deteriorate over time. Lock-in T-bar to allow for easy storage of the bottom net bar against upright for pitch maintenance. Reinforced net support system prevents bowing under intense tension. New, heavy duty ratchet winch and webbing strap allows for high-class net shape with the inclusion of a failsafe wire providing 100% security during matches. Lock-in bottom net bar 38mm diameter aluminium bar with ground secure key lock mechanism complete with 4 sockets and whitePolyester powder coated of size 7.32m x 2.44m Set = 2 Goals with 4 x 460mm deep sockets, and net etc. all complete as per FIFA Specification. MAke :- Freewill/ harrod/ shelde.Football Field Goal Post, Corner Flag & Dugout |
| 111 | Supply and Installation of Corner Flag (1 set=4Nos)Football Field Goal Post, Corner Flag & Dugout |
| 112 | DUGOUTSupply of Players dugout structure fabricated from MS tube having minimum dimension of 50 x 50 mm Square Tube detachable framework with matt finish. The height of the dugout will be 2.05 meter at front side, 0.4 Mtr Radius curved roof and 4.9mtr length The seating capacity will be of 10 players. The structure will be covered with 3mm thick transparent or colored polycarbonate sheet on top and two sides.The Structure is Provide with HDPE Blow Molded Seat FI1002 Double-wall hollow blow mold bucket type seat having minimum dimensions as 500 mm side length x 440 mm front width x 420 mm rear height in one piece of HDPE having minimum shell thickness of 3 mm on each wall. Minimum seat density of 0.95 gram/cm3, weight of plastic chair should not be less than 2.65 kg. Chair should withstand in high temperature not less than 50°C with ultraviolet stabilizer and color fastness, having ergonomic design, the chair should be fixed with Metal Inserts moulded inside seat to connect seat with Galvanized pipes 32mm OD tube and 2 mm thickness running under the chairs. The pipes are resting above the structure. Water should not accumulate on chair. Chair should have a warranty of 2 years against significant colour fading and 3 years against breakage due to manufacturing defects. Chair Plastic Part should have been tested with xenon –Arc exposure Test as per ISO 4892-2:2013, Cycle-1.The Grey Sale Rating should be (GSR): > 4, Delta Δ E: < 3 MAke :- Freewill/ harrod/ shelde Football Field Goal Post, Corner Flag & Dugout |
| 113 | Construction of granular sub-base by providing Grading VI close graded Material, spreading in uniform layers with motor grader on prepared surface, mixing by place in method rotavator at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Cricket Practice Pitch & Warm-Up Area |
| 114 | Basketball Court |
| 115 | Volley Ball Court |
| 116 | Wet Mix Macadam:-Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Basketball Court |
| 117 | Volley Ball Court |
| 118 | Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.Basketball Court |
| 119 | Volley Ball Court |
| 120 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.Basketball Court |
| 121 | Volley Ball Court |
| 122 | Providing and laying bituminous macadam with hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder of 60/70 penetration grade of bitumen, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 504 complete in all respects.Basketball Court |
| 123 | Volley Ball Court |
| 124 | Providing and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respectsBasketball Court |
| 125 | Volley Ball Court |
| 126 | SYNTHETIC SPORTS SURFACESeamless point-elastic sports floor for outdoor Basketball, Volleyball, Handball, Tennis court, Kho Kho court & Kabaddi court. The system consists of a high resilient granular base with a polyurethane selflevelling elastic wear layer covered by a wear-resistant mat top coat finish. The PU-Sport© system is tested according to the latest leading standards: EN, DIN. including the following: (i) 7 mm thick in-situ Rubber Granule Elastic Layer (ii) 2 mm of PU layer which includes 1st Layer of two-component polyurethane pore sealer and 2nd Layer of twocomponent polyurethane self-leveling wear coat that ensures exceptional durability. And 3rd Layer two component aliphatic polyurethane topcoat with very high abrasion resistance, as well as stain resistance.(ii) Line Marking as per the requirement of the games.only.Basketball Court |
| 127 | Volley Ball Court |
| 128 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.Basketball Court |
| 129 | Volley Ball Court |
| 130 | Providing fixed basketball outdoor posts with 3.2 mtr. umbrella projection with 200 mm square mild steel pipe powder coated of approved make with front side safety padding of 5.5” thick foam blue colour and 30mm transparent acrylic 180x105x 30mm of approved makewith international standard double die frame aluminum anodized/steel powder coated with built in brackets for mounting including dunking rim solid 20mm thick with three spring mechanism box packing of approvedmake with nets of regulation size 45 cm, cup shape of heavy duty nylon silky mix white coloured cord..Make Freewill / AMEZ Sports/ SAM EnterprisesBasketball Court |
| 131 | VOLLEYBALL POLESupply of adjustable, internal winding poles with net including sleeves and cover for Volleyball court make Freewill / SPORT TECH/ uphosVolley Ball Court |
| 132 | P.C.C. work M-15 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying.Cricket Practice Pitch & Warm-Up Area |
| 133 | Supplying and stacking of good earth mixed with appropiate proportion of sand as per design requirements at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).Cricket Practice Pitch & Warm-Up Area |
| 134 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mmCricket Practice Pitch & Warm-Up Area |
| 135 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).Cricket Practice Pitch & Warm-Up Area |
| 136 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.Cricket Practice Pitch & Warm-Up Area |
| 137 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%),flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).Cricket Practice Pitch & Warm-Up Area |
| 138 | Pace Friendly pitch Pitch area: supply and installation 12 mm thick dense, Knit De Knit polypropylene fibres surfaces over 6 mm thick shock pad for Cricket Wicket / Pitch area, permanent installation with adhesive. Pile Height 6 mm high Pile Product Weight should not less than 1,550gsm AS PER ECB Make :- PPJ Playrite U.K. or equivalentCricket Practice Pitch & Warm-Up Area |
| 139 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Basketball Court |
| 140 | Volley Ball Court |
| 141 | Archery Court |
| 142 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Basketball Court |
| 143 | Volley Ball Court |
| 144 | Archery Court |
| 145 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Basketball Court |
| 146 | Volley Ball Court |
| 147 | Archery Court |
| 148 | Providing & Painting two or more coats with Premium Acrylic Smooth Exterior Paint with Silicon Additives of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including the cost, conveyance, taxes of all materials, cost of all materials, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make:Dulux/Nerolac/Berger/Asian Paint)Basketball Court |
| 149 | Volley Ball Court |
| 150 | Archery Court |
| 151 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ).Basketball Court |
| 152 | Volley Ball Court |
| 153 | Archery Court |
| 154 | Providing & laying granite stone flooring in Floors and landing using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) Ground FloorBasketball Court |
| 155 | Volley Ball Court |
| 156 | Archery Court |
| 157 | Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) Ground FloorBasketball Court |
| 158 | Volley Ball Court |
| 159 | Archery Court |
| 160 | E.I. WORKCRICKET FIELD LIGHTINGSupply, Installation, Testing and Commissioning of Energy efficient LED Sports Arena Luminaire, with Minimum system wattage 1600W or above with system efficacy of >=110lm/W with CCT 5700K +/-355K as per ANSI), Light quality as per International Broadcasting standards meeting minimum Color Rendering Index as well as Television Lighting Consistancy Index values 94 or better , The Luminaire housing should be single piece made of Aluminum with uniquely designed thermal management for rapid thermal healing through passive cooling method with no dependency on active cooling devices. (No active cooling devices/fans allowed) and powder coated with corrosion resistance matt finish powder coating . The LED Chip shall be of SMD type and Ceramic Base High Power LEDs (COB type LED chip is not acceptable. Multichip LED arrays is not acceptable) of reputed Make of LED-Nichia/ CREE/ Lumiled/Osram . Individual LED wattage shall be >=1W and <=4 W. The light engine should use Metal Core PCB with high grade aluminum (AL5052) and should have a thermal conductivity of >2W/mK. Luminaire must have minimum Ingress protection of IP66 and Impact Resistance of IK08. The Luminaire should be equiped with UV stabilized Injection Molded Polycarbonate lens cum Cover to have high efficient glare free optics with no yellowing with respect to time (Glass cover Not allowed). The Luminaire Housing or Optical Cover should be equipped with OEM logo engraved or embossed (Stickering/Screen printing not acceptable) . The Luminaire shall be available in different beam angles as per requirement of design and to meet required lighting parameters and a lux level warranty as per tender.LED Sports Flood Light luminaires shall be one single unit with Non-integral or Remote gear.The driver shall be non-integral type and shall be placed near the mast in aproperly ventilated outdoor panel. All components shall be mounted in an outdoor driver panel made of 2mm Hot dip GI outdoor IP66 panel with provision of aluminium tray, cable terminals and forced-cum-natural cooling sheet. The driver should be confined in a enclosure with IP rated cable gland for output and input power and the same shall be placed inside the outdoor driver panel. Driver shall be DMX dimming control compatible to use with suitable dimming control & control accessories. Dimming protocol should be with remote control monitoring and individual light fixture should be addressable and compatible for integration with sound control . The Luminaire and Driver shall have BIS certification. The drive shall be Ultra High Efficiency Potted constant current Isolated programmable and IP67 rated LED driver that operates from 176-305 Vac input with excellent power factor, 0-10V/PWM/3-Timer-Modes Dimmable type driver . Compact Metal Case with Excellent Thermal Performance, Full Power at Wide Output Current Range (Constant Power), Adjustable Output Current (AOC) with Programmability. Output Lumen Compensation feature, All-Around Protection: To ensure trouble-free operation, inbuilt protection against input surge, input under voltage, input over voltage, output over voltage, short circuit, and over temperature. LED Driver shall have efficiency ≥85%, power factor 0.95 at full power,ripple current ≤5%, flicker <1% , External Surge protection (SPD) with Thermal Protection (TMOVs) of minimum 20KV with capability to withstand a minimum of 15 pulses of 20KV to be separately installed (fixed with screws) Externally/Internally with each fixture, compliant to IEC 62305 & IEC 61643-11- 2011. Quantity of Min Luminaires as per teh OEM design to meet the desired lux levels as per the tender requirement Following documents to be submitted after award of the contract : Luminaire and Driver TDS, Third party NABL LM79/Photometry report, Third party Type test certificate, Third party CRI/TLCI test report from any international third-party accredited laboratory(UL/TUV only). IP, IK, Vibration and salt spray test certificates from OEM NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliance, BIS Certificate for Luminaires & Drivers.(Makes: Philips/Lighting Technologies/Schreder/Disano/Fael luce)The design should meet minimum below Light level requirements for National level Broadcasting.and designed suitably for cricket as well as football requirements.For Cricket Pitch – (Grid 2m x 2m) (Area 20M x 20M)Vertical Lux to Main Cameras (El + 10M) - 1750 lux Avg.: Min/Max 0.8; Min/Avg. 0.9Horizontal Lux – 2000 Avg.; Min/ Max 0.8; Min/Avg. 0.9In-field Area (Grid 5m x 5m) (Area 27M Radius)Vertical Lux to Main Cameras (El + 10M) - 1250 lux Avg.: Min/Max 0.6; Min/Avg. 0.7Horizontal Lux – 1500 Avg.; Min/ Max 0.6; Min/Avg. 0.7Out-Field Area – (Grid 5m x 5m)(Area 64M Radius)Vertical Lux to Main North & South Cameras (El + 10M)- 1000 lux Avg.: Min/Max 0.4; Min/Avg. 0.5Horizontal Lux – 1250 Avg.; Min/ Max 0.4; Min/Avg. 0.5All above light levels are maintained values. Maintenance Factor = 0.9For footballIt should meet the Latest FIFA LIGHTING STANDARD D Televised Standard requirements of Light levels .The contractor shall submit the lighting design and all the reports as per the specificaion mentioned in the BOQ meeting the required Lux levels for necessary approval from SE, Electrical Circle(R&B) and CE,Bdgs, Odisha, Bhubaneswar.Further, before dispatch of material, there will be pre-dispatch factory inspection in the presence of CE,Bdgs, Odisha, Bhubaneswar, SEEC(R&B), O, BBSR and concerned engineer from divisional office. After supply of material, a random sample will be chosen and will be sent to Govt. NABL approved lab for destructive test for verification of genuinity of all the reports.If the product does not comply with the reports submitted, the whole lot will be rejected.Cost of the testing and pre-dispatch factory inspection shall be borne by the contractor. |
| 161 | Design, Manufacture, Supply and Erection of hot dip galvanised, polygonal High Mast lighting tower with fixed head frame, of height not less than 35 meters from the bottom of the headframe, designed for mounting required number of LED sports flood light luminaires (quantity and weight as per item no. 3 below) to achieve the specified lighting level on cricket ground, including Design (Conforming to PLG 7, IS- 875 (Part-3):2015, Galvanizing confirming to BSEN ISO 1461:1991 and material confirming to BS EN 10025, S355, IS:2062) of mast, head frame, base plate, foundation bolts, nuts, washers, anchor plate and template, complete with integral power tool / winch arrangement and motorized mechanism suitable for operation of man-rider maintenance system, conforming to approved design, with material of suitable structural steel grade, hot dip galvanizing, and design to withstand 200 kmph of wind load as per IS 875 (Part 3): 2015, including fabrication, transportation, erection, alignment, testing, commissioning, GI lightning protection arrangement at top, and construction of RCC foundation in M-25 concrete based on actual safe bearing capacity of soil as per approved geotechnical report, including all labour and materials, complete as required and as approved by Engineer-in-Charge.The structural design of the pole and wind load calculation by considering the weight of the luminaires will be duly vetted by IIT/NIT/Design wing of PWD and shall be approved by concerned civil wing SE/CCE/competant authority.Cost of the testing shall be borne by the contractor.. (Makes: Valmont/ Lysaght/ Transrail). Scope included Isntallation of Lightening arrester as well as the Aviation Lamps . |
| 162 | Supply, Installation, testing and commissioning of outdoor type high mast power panel for lighting towers of cricket ground integrated with remote driver rack for operation of LED sports lighting fixtures. The driver shall be non-integral type and shall be placed near the mast in aproperly ventilated outdoor panel. All components shall be mounted in an outdoor driver panel made of 2mm Hot dip GI outdoor IP66 panel with provision of aluminium tray, cable terminals and forced-cum-natural cooling sheet. The driver should be confined in a enclosure with IP rated cable gland for output and input power and the same shall be placed inside the outdoor driver panel.The panel shall have separate compartments for power components and driver units to ensure proper ventilation and heat dissipation. It shall include necessary protection devices such as MCCB or MCB, contactor-based switching arrangement, timer or manual control system, surge protection devices, and internal wiring with suitable terminal blocks. The panel shall also accommodate the remotely located LED drivers and shall be provided with adequate space for cable termination and maintenance access. Complete as per direction of Engineer-in-Charge.The rate is inclusive of Mast sub panel which includes S/I/T&Commissioning of LT outdoor floor mounted CPRI Tested cubical type panel made out by 2mm Hot dip GI outdoor IP66 panel is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.In commer-01 number of 250 Amps MCCB 25 KA , tmr based, Ics=100%Icu, (Legrand-dpx3/abb-formula/schneider-cvs/siemens-3va) Busbar- 04 numbers of 300A Aluinuium busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (ii) 36 nos 16-20A DP MCB 10kA,C series for arena lights Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication for both the source with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)..(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-250)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 250/5A 3 nos class 1 type(Make-Siemens/Schneider/ABB/Legrand) (iv) 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA for the incomer.Make of SPD-Siemens/Schneider/ABB/Legrand/OBO/Dehn. Make of MCB-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 |
| 163 | Design, manufacture, supply, installation, testing and commissioning of electrically operated external man-rider maintenance system suitable for safe maintenance of high mast sports lighting towers, comprising lifting cage, wire ropes, electric motor, reduction gearbox, guide arrangement, operating controls, manual emergency lowering arrangement, overload protection, emergency braking system, mechanical safety locking arrangement, limit switches, interlocks, all mechanical and electrical accessories, suitable for operation on 415 V, 3 phase, 50 Hz AC supply, complete with control panel and all safety features for reliable operation, complete as required and as approved by Engineer-in-Charge. The entire system shall be designed to ensure safe and reliable access to the high mast platform for maintenance personnel. (Makes: Valmont/ Lysaght/ Transrail) |
| 164 | Supply & Fixing of GI plate Earthing (600x600x6mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 165 | Providing and fixing 25mm X 5 mm GI strip at 0.50 meter below ground/suraface including connection/termination with nut, bolt, spring, washer excavation and refilling(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) as required. |
| 166 | Providing and fixing 50mm X 6 mm GI strip at 0.50 meter below ground/suraface including connection/termination with nut, bolt, spring, washer excavation and refilling(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) as required. |
| 167 | Supply and laying of following sizes 1.1 KV FRLS XLPE ARMOURED insulated cable with copper conductor, PVC inner sheathed overall PVC sheathed stranded in conformity to the technical specification and as per latest IS - codes. 3C X 4Sq.mm |
| 168 | Termination of 3C X 4Sq.mm. |
| 169 | Supply and laying of 25mm MS Conduit |
| 170 | Supply and laying of 40mm HDPE Pipe |
| 171 | Supply Installation, testing and Commissioning of DMX Based control system for the highmast Lighting using necessary DMX Controllers, Nodes, Splitters and DMX cables as required for the complete Operation of the system with Multiple scene creation as desired by the department.Make- Philips/Lighting Technologies/Schreder/Disano/Fael luce |
| 172 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF OUTDOOR LED VIDEO WALL DISPLAY. Screen Size: 40sqmtr (+/-5%). Design: latest product with specification of LED OEM to be quoted. Pixel pitch: 4 mm. Pixel configuration: SMD 3-in-1 LED package. Pixel density: 50,625 dot/m2 or better. Cabinet material: die-casting cabinet & aluminium module shell. Brightness: 6500 nit or more (minimum calibrated). Brightness uniformity: 90% or more. Module dimension: 960 x 960 x 91.9 mm. Viewing angle: 160 degrees or better (horizontal & vertical). Refresh rate: 3840 Hz or better. Frame frequency: 60 Hz. Working temperature: -20C to +55C. Working humidity: 90% RH. IP rating: IP66 or better (front & back). Certifications: BIS certificate on OEM brand & own India manufacturing unit for the offered LED tiles/cabinets; ISO 9001-2015, ISO 14001, ISO 27001, ISO 14064, OHSAS 45001, E-Waste compliance. 1no. LED CONTROLLER. Same make as the LED screen. Inputs/outputs: 2 x HDMI 1.3 inputs, 1 x USB 2.0 input, 10 x Ethernet ports for network connectivity, capacity up to 6.5 million pixels, 1 x audio input on 3.5mm connector, 1 x SPDIF digital audio output, 1 x audio output on 3.5mm connector. Resolution supported: 1920x1080, 3840x2160 @ 60Hz or better. Software: Android-based desktop UI supporting third-party apps, wireless screen mirroring from multiple platforms, terminal-app wireless voice control transmitted to the sound system, USB plug-and-play/copy-and-play playback supporting 4K HD decoding in H.265, H.264 and other industry-standard formats. 1no. ELECTRICAL CONTROL PANEL (PDU). Front door: 2 hinges with racks. 19\\" pillar front & 19\\" pillar rear, bolted on rack side. Earthing studs provided. Rack-mountable. Material: GI 120 GSM, thickness 1.5mm. IP rating: IP54. Surge protection: Class C. Anti-theft mounted design. AC input: 380V/220V. Remote control of PDU from central control over IP. Display panel showing cabinet temperature, cooling indication, external fan running status, alarm flashing and other parameters. 1 no. DATA PROCESSING UNIT. All-in-one PC, Core i5 (12th Generation), 4GB RAM, 256GB SSD, Q670 motherboard, keyboard & mouse. Certifications: BIS, ISO 9001-2015, ISO 20000-1, ISO 14001, ISO 27001, NABL, CE, RoHS, OHSAS 45001. 1 lot of SIGNAGE & CONTENT MANAGEMENT SOFTWARE (Software/Hardware). Ability to create playlists and send them over the network to 100 media players or more for playout based on schedule and sequencing. Software to be loaded on suitable hardware supplied by the vendor. License should support management of more than 200 video walls. 1 no. 10 KVA VOLTAGE STABILIZER. Working input range: 90V-300V. Output voltage range: 200V-240V +/-5%. Initial time delay: 5 to 10 seconds. Overload protection via MCB (stabilizer on/off mains). Operation: fully automatic, digital multifunctional display. Wire size: 10.0 sq mm. Quality certification: ISO 9001, ISO 14001.The cost is inclusive of mounting structure and pole .The pole should be designed to withstand 200 kmph . The agency should vet the structural design from NIT/IIT/Design cell of R&B . The structural design should be approved from concerned S.ERnB/CCE/Competent authority . MAKE:LG/BARCO/Delta/CHRISTIE/PANASONIC.2 nos. IP66 OUTDOOR SPEAKER WITH DUAL CHANNEL AMPLIFIER. 2-way long throw horn, LF driver 6.5\\" & HF 1\\" compression driver. Max power handling 120W@8 Ohms. 100V multi-taps: 60W/30W/15W. Frequency range: 100Hz-16kHz. Sensitivity: 99dB, max SPL 116dB. Coverage: 100 x 60 degrees (H x V). IP66 rated, impact & UV resistant ABS enclosure. Mounting bracket included. Colour: light grey or equivalent. Amplifier: dual channel power amplifier, 2 x 240W @ 4 Ohm - 480W @ 70/100V. Frequency response (+/-3dB): 20Hz-20kHz. Signal/Noise >95dB, stereo low-Z & mono high-Z switch. Cooling: temperature-controlled fan. Technology: Class-D. 1no. 8-PORT POE NETWORK SWITCH. 8 Port L2 POE industrial switch with minimum 1 No x 1G SFP port. Must support 8 x 100/1000 Base-T fixed RJ45 POE ports. Total POE budget: 240W. Switch protection grade: IP40 or better. Quality certification (India): ISO 9001, ISO 27001. Switch OEM must be recognized as DPIIT India. 1lot of SUPPORTING STRUCTURE (Hardware). Material type: hot-dip galvanized. Vertical pole pillar: dual pillar. Pole thickness: 5mm. LED frame pipe dimension: as per requirement. Foundation/substructure to be duly vetted by a recognized Govt. institution/Govt. college/NIT/IIT with necessary IS codal provisions followed to meet SBC, wind speed, earthquake and other design load requirements. 1 lot of ELECTRICAL WORK. 6-core electrical wiring with armoured copper cable, complete from PDU/DP to the LED structure as per requirement. 2 nos. EARTHING. Both chemical earthing and salt-charcoal earthing pits as per requirement, complete with accessories. 1 no. REMOTE LOCATION CONNECTIVITY. Dual-SIM Wi-Fi router, 4G & 5G SIM compatible, all-GSM support, for remote monitoring and content push. |
| 173 | BASKET BALL COURT LIGHTING :-SITC of high-quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF > 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=500 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement. Only sport series flood light will be accepted.Make- Philips/ Lighting Technologies/ Schréder |
| 174 | Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Valmont /Vakrangee |
| 175 | Excavation in all types of soil for foundation pit size 1.4m×1.4m×1.8m depth includingshoring/strutting if required, stacking excavated material and disposal within 50m lead Plain Cement Concrete M10 (1:3:6) for PCC bed below footing, 100 mm thick, includingmixing, placing and curing (Size: 1.5m×1.5m),Reinforced Cement Concrete M25 (fck=25 N/mm², Fe500 TMT rebar) for RCC footing 1400×1400×600 mm, including formwork, placing, vibrating and curing ,Reinforced Cement Concrete M25 for RCC pedestal 650×650×1200 mm height,including formwork, placing, vibrating and curingFe500 TMT reinforcement bars for footing and pedestal (T12 @ 150 c/c both ways bottom mat, 8T12 vertical pedestal bars, T8 @ 150 stirrups) including cutting, bending, binding and placing Backfilling around foundation with excavated/selected earth in 150 mm layers, watered and compacted to 95% MDD using plate compactor Cement mortar (1:3) grouting under base plate after pole erection, finishedneat and flush with pedestal top.The foundation design should be approved from concerned SE/CCE(Civil wing) before execution of the work. |
| 176 | SUB PANEL:S/I/T&Commissioning of LT outdoor floor mounted doubledoor CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given. Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 100A aluminum busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing :12 Nos 6A DP MCB. (10 KA), C series complete as per the direction of Engineer-in-chargeMAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200 |
| 177 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.Power Cable 3.5C 25sq mm Aluminium Armored Cable : 3.5 core 25sq mm Armored aluminium cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating. |
| 178 | Power Cable 3C* 2.5sq mm Copper UnArmored Cable : 3 core 2.5 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating.. |
| 179 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 180 | EARTHINGSupplying,installation,testing & commissioning Of Earthing with GI earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 181 | Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge.. |
| 182 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 183 | VOLLYBALL COURT LIGHTINGSITC of high-quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF > 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=500 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement. Only sport series flood light will be accepted.Make- Philips/ Lighting Technologies/ Schréder |
| 184 | Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Valmont /Vakrangee |
| 185 | Excavation in all types of soil for foundation pit size 1.4m×1.4m×1.8m depth includingshoring/strutting if required, stacking excavated material and disposal within 50m lead Plain Cement Concrete M10 (1:3:6) for PCC bed below footing, 100 mm thick, includingmixing, placing and curing (Size: 1.5m×1.5m),Reinforced Cement Concrete M25 (fck=25 N/mm², Fe500 TMT rebar) for RCC footing 1400×1400×600 mm, including formwork, placing, vibrating and curing ,Reinforced Cement Concrete M25 for RCC pedestal 650×650×1200 mm height,including formwork, placing, vibrating and curingFe500 TMT reinforcement bars for footing and pedestal (T12 @ 150 c/c both ways bottom mat, 8T12 vertical pedestal bars, T8 @ 150 stirrups) including cutting, bending, binding and placing Backfilling around foundation with excavated/selected earth in 150 mm layers, watered and compacted to 95% MDD using plate compactor Cement mortar (1:3) grouting under base plate after pole erection, finishedneat and flush with pedestal top.The foundation design should be approved from concerned SE/CCE(Civil wing) before execution of the work. |
| 186 | SUB PANEL:S/I/T&Commissioning of LT outdoor floor mounted doubledoor CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given. Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 100A aluminum busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing :12 Nos 6A DP MCB. (10 KA), C series complete as per the direction of Engineer-in-chargeMAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200 |
| 187 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.Power Cable 3.5C 25sq mm Aluminium Armored Cable : 3.5 core 25sq mm Armored aluminium cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating. |
| 188 | Power Cable 3C* 2.5sq mm Copper UnArmored Cable : 3 core 2.5 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating.. |
| 189 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 190 | EARTHINGSupplying,installation,testing & commissioning Of Earthing with GI earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 191 | Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge.. |
| 192 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 193 | ARCHERY FIELD LIGHTINGSITC of high-quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF > 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=500 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement. Only sport series flood light will be accepted.Make- Philips/ Lighting Technologies/ Schréder |
| 194 | Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Valmont /Vakrangee |
| 195 | Excavation in all types of soil for foundation pit size 1.4m×1.4m×1.8m depth includingshoring/strutting if required, stacking excavated material and disposal within 50m lead Plain Cement Concrete M10 (1:3:6) for PCC bed below footing, 100 mm thick, includingmixing, placing and curing (Size: 1.5m×1.5m),Reinforced Cement Concrete M25 (fck=25 N/mm², Fe500 TMT rebar) for RCC footing 1400×1400×600 mm, including formwork, placing, vibrating and curing ,Reinforced Cement Concrete M25 for RCC pedestal 650×650×1200 mm height,including formwork, placing, vibrating and curingFe500 TMT reinforcement bars for footing and pedestal (T12 @ 150 c/c both ways bottom mat, 8T12 vertical pedestal bars, T8 @ 150 stirrups) including cutting, bending, binding and placing Backfilling around foundation with excavated/selected earth in 150 mm layers, watered and compacted to 95% MDD using plate compactor Cement mortar (1:3) grouting under base plate after pole erection, finishedneat and flush with pedestal top.The foundation design should be approved from concerned SE/CCE(Civil wing) before execution of the work. |
| 196 | SUB PANEL:S/I/T&Commissioning of LT outdoor floor mounted doubledoor CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given. Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 100A aluminum busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing :12 Nos 6A DP MCB. (10 KA), C series complete as per the direction of Engineer-in-chargeMAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200 |
| 197 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.Power Cable 3.5C 25sq mm Aluminium Armored Cable : 3.5 core 25sq mm Armored aluminium cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating. |
| 198 | Power Cable 3C* 2.5sq mm Copper UnArmored Cable : 3 core 2.5 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating.. |
| 199 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 200 | EARTHINGSupplying,installation,testing & commissioning Of Earthing with GI earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 201 | Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge.. |
| 202 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender