Tender For Improvement Of District Stadium, Boudh Such As Construction Of Facility Building, Tool Shed, Site Development Works And Renovation Of Existing Buildings.
Tender Value
15.45 Crore
Estimated cost
Bid Submission
13 Aug 2026
13 days left
EMD
15.46 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Boudh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of District Stadium, Boudh Such As Construction Of Facility Building, Tool Shed, Site Development Works And Renovation Of Existing Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKRemoving old lime or cement plaster from walls including raking out joints 12 mm deep and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 2 | First Floor |
| 3 | Second Floor |
| 4 | Renovation Of Existing Facility Building |
| 5 | Site Site Site Dismantling Works |
| 6 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete as per the specification and direction of the Engineer-in-charge.Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 7 | First Floor |
| 8 | Second Floor |
| 9 | Renovation Of Existing Facility BuildingGround Floor |
| 10 | First Floor |
| 11 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 12 | First Floor |
| 13 | Renovation Of Existing Facility Building |
| 14 | Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 15 | First Floor |
| 16 | Renovation Of Existing Facility Building |
| 17 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 18 | First Floor |
| 19 | Second Floor |
| 20 | Renovation Of Existing Facility Building |
| 21 | Dismantling and removing 2.5 cm thick grading concrete from roof slab cleaning the surface lowering and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.Renovation Of Existing Facility BuildingFirst Floor |
| 22 | Second FloorRenovation Of Existing Indoor Stadium Cum Gymnasium |
| 23 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.Site Dismantling Works |
| 24 | Dismantling kerb stone by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metre.Site Dismantling Works |
| 25 | Dismantling of Granular courses of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately.Site Dismantling Works |
| 26 | Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.Site Site Dismantling Works |
| 27 | Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.Site Dismantling Works |
| 28 | Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and gravel mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge.(a)Upto 1.5mtr DepthCricket Field Facility Building |
| 29 | Tool Shed |
| 30 | New Tensile Canopy For Existing Facility Building |
| 31 | Compound Wall & Site Filling |
| 32 | RCC Periphery Drain |
| 33 | 3Mtr Wide Drain |
| 34 | Entrance Gate B/W To Facility Building |
| 35 | (b)From 1.5mtr to 3.0mtr DepthCricket Field Facility Building |
| 36 | Tool Shed |
| 37 | New Tensile Canopy For Existing Facility Building |
| 38 | 3Mtr Wide Drain |
| 39 | Entrance Gate B/W To Facility Building |
| 40 | (c)From 3.0mtr to 4.5mtr Depth3Mtr Wide Drain |
| 41 | Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.Cricket Field Facility Building |
| 42 | Tool Shed |
| 43 | New Tensile Canopy For Existing Facility Building |
| 44 | Compound Wall & Site Filling |
| 45 | RCC Periphery Drain |
| 46 | 3Mtr Wide Drain |
| 47 | Entrance Gate B/W To Facility Building |
| 48 | Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge.Cricket Field Facility Building |
| 49 | Tool Shed |
| 50 | New Tensile Canopy For Existing Facility Building |
| 51 | 3Mtr Wide Drain |
| 52 | Site Dismantling Works |
| 53 | Entrance Gate B/W To Facility Building |
| 54 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.Cricket Field Facility Building |
| 55 | Tool Shed |
| 56 | New Tensile Canopy For Existing Facility Building |
| 57 | 3Mtr Wide Drain |
| 58 | Entrance Gate B/W To Facility Building |
| 59 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. Cricket Field Facility Building |
| 60 | Tool Shed |
| 61 | New Tensile Canopy For Existing Facility Building |
| 62 | Compound Wall & Site Filling |
| 63 | Internal Driveway (Cc Road) |
| 64 | 3Mtr Wide Drain |
| 65 | Entrance Gate B/W To Facility Building |
| 66 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.From 1.5mtr to 4.5Mtr DepthCricket Field Facility Building |
| 67 | Tool Shed |
| 68 | New Tensile Canopy For Existing Facility Building |
| 69 | 3Mtr Wide Drain |
| 70 | Entrance Gate B/W To Facility Building |
| 71 | Upto 1.5mtr DepthCricket Field Facility Building |
| 72 | Compound Wall & Site Filling |
| 73 | RCC Periphery Drain |
| 74 | Cement concrete of proportion (1:4:8) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6\\") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge.Internal Driveway (Cc Road) |
| 75 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper positionR.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.For Beyond 1.5 M to 4.5M Depth3Mtr Wide Drain |
| 76 | For upto 1.5 M DepthCricket Field Facility Building |
| 77 | Tool Shed |
| 78 | New Tensile Canopy For Existing Facility Building |
| 79 | Compound Wall & Site Filling |
| 80 | Entrance Gate B/W To Facility Building |
| 81 | R.C.C. Plinth BeamGround FloorCricket Field Facility Building |
| 82 | Tool Shed |
| 83 | New Tensile Canopy For Existing Facility Building |
| 84 | Compound Wall & Site Filling |
| 85 | Entrance Gate B/W To Facility Building |
| 86 | R.C.C. Beams, columns, grider and bressmer etc.Cricket Field Facility BuildingGround Floor |
| 87 | First Floor |
| 88 | Tool Shed |
| 89 | New Tensile Canopy For Existing Facility Building |
| 90 | Compound Wall & Site Filling |
| 91 | Entrance Gate B/W To Facility Building |
| 92 | R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shades and chajjas up to 4.3Mtr. Height.Cricket Field Facility BuildingGround Floor |
| 93 | First Floor |
| 94 | 3Mtr Wide Drain |
| 95 | R.C.C. LintelCricket Field Facility BuildingGround Floor |
| 96 | First Floor |
| 97 | RCC StaircaseCricket Field Facility BuildingGround Floor |
| 98 | First Floor |
| 99 | R.C.C. WallGround FloorCompound Wall & Site Filling |
| 100 | For Beyond 1.5 M to 4.5M Depth3Mtr Wide Drain |
| 101 | RCC DRAINGround FloorRCC Periphery Drain |
| 102 | (B)R.C.C. Floor and Roof slab, landing, balconies, projecting, sun shades and chajjas up to 4.3Mtr. Height.Ground FloorRCC Periphery Drain |
| 103 | (C)R.C.C. Drain WallGround FloorRCC Periphery Drain |
| 104 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment).For Depth 1.5m to 4.5m3Mtr Wide Drain |
| 105 | Ground FloorCricket Field Facility Building |
| 106 | First Floor |
| 107 | Tool Shed |
| 108 | New Tensile Canopy For Existing Facility Building |
| 109 | Compound Wall & Site Filling |
| 110 | RCC Periphery Drain |
| 111 | 3Mtr Wide Drain |
| 112 | Entrance Gate B/W To Facility Building |
| 113 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Ground FloorCricket Field Facility Building |
| 114 | Tool Shed |
| 115 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Ground FloorCricket Field Facility Building |
| 116 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Cricket Field Facility BuildingGround Floor |
| 117 | First Floor |
| 118 | Tool Shed |
| 119 | Compound Wall & Site Filling |
| 120 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Cricket Field Facility BuildingGround Floor |
| 121 | First Floor |
| 122 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 123 | First Floor |
| 124 | Second Floor |
| 125 | Renovation Of Existing Facility Building |
| 126 | Providing 12 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls punning and bitumen coating including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.Ground FloorCricket Field Facility Building |
| 127 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Cricket Field Facility BuildingGround Floor |
| 128 | First Floor |
| 129 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 130 | First Floor |
| 131 | Second Floor |
| 132 | Tool Shed |
| 133 | Renovation Of Existing Facility Building |
| 134 | Compound Wall & Site Filling |
| 135 | Entrance Gate B/W To Facility Building |
| 136 | Providing 18mm thick cement plaster on external surfaces of building in two layers consisting of inner layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and outer layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, royalties, scaffolding, staging, watering before plastering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge.Cricket Field Facility BuildingGround Floor |
| 137 | First Floor |
| 138 | Compound Wall & Site Filling |
| 139 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground FloorTool Shed |
| 140 | Renovation Of Existing Facility Building |
| 141 | New Tensile Canopy For Existing Facility Building |
| 142 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 143 | First Floor |
| 144 | Second Floor |
| 145 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-20 in cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge.Ground FloorCricket Field Facility Building |
| 146 | Tool Shed |
| 147 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.First FloorCricket Field Facility Building |
| 148 | Renovation Of Existing Facility BuildingFirst Floor |
| 149 | Second FloorRenovation Of Existing Indoor Stadium Cum Gymnasium |
| 150 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (Inside)Cricket Field Facility BuildingGround Floor |
| 151 | First Floor |
| 152 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 153 | First Floor |
| 154 | Second Floor |
| 155 | Tool Shed |
| 156 | Renovation Of Existing Facility Building |
| 157 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (Outside)Cricket Field Facility BuildingGround Floor |
| 158 | First Floor |
| 159 | Tool Shed |
| 160 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 161 | First Floor |
| 162 | Second Floor |
| 163 | Renovation Of Existing Facility BuildingGround Floor |
| 164 | First Floor |
| 165 | New Tensile Canopy For Existing Facility Building |
| 166 | Entrance Gate B/W To Facility Building |
| 167 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Cricket Field Facility BuildingGround Floor |
| 168 | First Floor |
| 169 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 170 | First Floor |
| 171 | Second Floor |
| 172 | Renovation Of Existing Facility Building |
| 173 | Tool Shed |
| 174 | Providing & Painting two or more coats with Premium Acrylic Smooth Exterior Paint with Silicon Additives of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including the cost, conveyance, taxes of all materials, cost of all materials, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Cricket Field Facility BuildingGround Floor |
| 175 | First Floor |
| 176 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 177 | First Floor |
| 178 | Second Floor |
| 179 | Renovation Of Existing Facility BuildingGround Floor |
| 180 | First Floor |
| 181 | New Tensile Canopy For Existing Facility Building |
| 182 | Compound Wall & Site Filling |
| 183 | Entrance Gate B/W To Facility Building |
| 184 | Tool Shed |
| 185 | Supplying, fitting and fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK/ KAJARIA/ SOMANY) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.Cricket Field Facility BuildingGround Floor |
| 186 | Renovation Of Existing Facility Building |
| 187 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 188 | First Floor |
| 189 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK/ KAJARIA/ SOMANY) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.Cricket Field Facility BuildingGround Floor |
| 190 | Renovation Of Existing Facility Building |
| 191 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 192 | First Floor |
| 193 | Providing & laying granite stone flooring using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of granite tiles shall be approved before procurement and use.) Ground FloorCricket Field Facility Building |
| 194 | Tool Shed |
| 195 | Renovation Of Existing Facility Building |
| 196 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 197 | First Floor |
| 198 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.Ground FloorCricket Field Facility Building |
| 199 | Renovation Of Existing Facility Building |
| 200 | Fixing granite tiles of approved dimension area above 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge. Ground FloorCricket Field Facility Building |
| 201 | Renovation Of Existing Facility Building |
| 202 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 203 | First Floor |
| 204 | Providing and laying 62 mm thick cement concrete flooring with Hardener topping comprising of an under layer of 50 mm thick cement concrete of mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agrregate 20 mm nominal size) and 12 mm thick cement hardener topping layer of mix 1:2 ( 1 cement hardener mix : 2 parts of screened & washed stone agrregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litres per bag of cement and laying the concrete in alternate panels of 2m x 2m (max) including cleaning the surface to make free from foreign particles, cost of all materials, conveyance, taxes, loading, unloading, royalty, T&P, etc, all complete as per the direction of Engineer-in-Charge.Ground FloorTool Shed |
| 205 | Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.(Make-Green Land / Century/ Alstone)Cricket Field Facility BuildingGround Floor |
| 206 | First Floor |
| 207 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 208 | First Floor |
| 209 | Second Floor |
| 210 | Renovation Of Existing Facility Building |
| 211 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.Cricket Field Facility BuildingGround Floor |
| 212 | First Floor |
| 213 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 214 | First Floor |
| 215 | Second Floor |
| 216 | Renovation Of Existing Facility Building |
| 217 | Supplying,Installation of pressed Steel Doors of the specified dimensions and accessories such as hinges,door stopper,tower bolt, door handle ,door closer,dead lock,consedaled flush bolt,Shaft lock,martise lock and vision panel etc. complete as mentioned along with warranty covverage and after sales service etc.inclusive of all costs, GST, cost of delivery charges ,fixing,fittings and any other invidential charges etc.complete.8 Nos Hinges,12No Door Stoppers,2 No Tower Bolt,2 No martise lock (Door Size 2000x2400).Cricket Field Facility Building |
| 218 | 8 Nos Hinges,12No Door Stoppers,2 No Tower Bolt,1 No martise lock (Door Size 1500x2400)Cricket Field Facility Building |
| 219 | Tool Shed |
| 220 | Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door Fittings. (9111198) Unilite Package BTS 75,UL PT 10 with Cover,UL PT 20 with Cover,UL US 10 Luck with Cover and PT 24,Dorma Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole, including the cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. (Make: Dorma/Godrej)(a)In all FloorRenovation Of Existing Indoor Stadium Cum Gymnasium |
| 221 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat & painting Two Coats of Synthetic Enamel Paint of approved steel primer & painting.Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 222 | Renovation Of Existing Facility Building |
| 223 | Supplying, fitting & fixing of M.S Rolling shutter confirming to BIS specification as per approved design and drawing including cutting holes in brick/RCC surface and grouting the hold fasts/clamps properly in line and plumb with CC(1:2:4) using 12mm size black hard granite chips and making good to the damages including cost of all materials ,transportation, all labour, sundries, T&P and priming one coat with approved quality metal primer etc. complete as per direction of Engineer in charge.80 x 1.25mm MS lath with 1.25mm thick top coverGround FloorTool Shed |
| 224 | Supplying and installing Aluminium System - Fixed windows made out of ALUPURE/Equivalent make frame dimension of 39mm x 42mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3).Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of MCCOY /Dowcorning or equivalent. orSupplying and installing Aluminium System - Openable windows made out of ALUPURE/Equivalent make frame dimension of 39mm x 62.9mm & Sash dimension of 46mm x 92mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. orSupplying and installing Aluminium System - Sliding windows made out of ALUPURE/Equivalent make frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. orGround FloorCricket Field Facility Building |
| 225 | First Floor |
| 226 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 227 | First Floor |
| 228 | Renovation Of Existing Facility Building |
| 229 | Tool Shed |
| 230 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete.Ground FloorCricket Field Facility Building |
| 231 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 232 | First Floor |
| 233 | Renovation Of Existing Facility Building |
| 234 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.Ground FloorCricket Field Facility Building |
| 235 | Renovation Of Existing Indoor Stadium Cum Gymnasium |
| 236 | First Floor |
| 237 | Renovation Of Existing Facility Building |
| 238 | Compound Wall & Site Filling |
| 239 | Entrance Gate B/W To Facility Building |
| 240 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metreCompound Wall & Site Filling |
| 241 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Ground FloorCricket Field Facility Building |
| 242 | Tool Shed |
| 243 | Renovation Of Existing Facility Building |
| 244 | Compound Wall & Site Filling |
| 245 | Entrance Gate B/W To Facility Building |
| 246 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 247 | First Floor |
| 248 | Finishing with Epoxy paint (Two or more coats) on steel work at all locations prepared and applied as per manufacturer's ecifications including appropriate priming coat(Red Oxide Zinc Chromate) , preparation of surface, etc. complete as per Direction of E.I.C.Ground FloorTool Shed |
| 249 | Entrance Gate B/W To Facility Building |
| 250 | Cricket Field Facility BuildingSecond Floor |
| 251 | New Tensile Canopy For Existing Facility BuildingSecond Floor |
| 252 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ).Cricket Field Facility BuildingGround Floor |
| 253 | First Floor |
| 254 | Renovation Of Existing Indoor Stadium Cum GymnasiumGround Floor |
| 255 | First Floor |
| 256 | Providing and applying waterproofing treatment to roof including treatment of construction joints and cracks by pressure grouting, bore packing, formation of coving (50×50 mm), thorough surface preparation, and application of single component PU based liquid waterproofing membrane (Nitoproof 600PF or equivalent) in two coats to achieve minimum 1.5 mm dry film thickness, including 300 GSM geotextile separation layer and protective screed where specified, complete with all materials, labour, tools, curing and finishing as per specifications and direction of Engineer-in-Charge.Cricket Field Facility Building |
| 257 | Renovation Of Existing Facility Building |
| 258 | Renovation Of Existing Indoor Stadium Cum Gymnasium |
| 259 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone/Samudyam make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners.Cricket Field Facility BuildingGround Floor |
| 260 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per specifications and direction of Engineer-in-Charge.Compound Wall & Site Filling |
| 261 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete as per specifications and direction of Engineer-in-Charge.Cricket Field Facility Building |
| 262 | Tool Shed |
| 263 | New Tensile Canopy For Existing Facility Building |
| 264 | Entrance Gate B/W To Facility Building |
| 265 | Providing, and fixing a complete tensile fabric membrane of PVC/PVDF coated architectural membrane (900 GSM), and complete as per approved drawings and specifications. Measurement shall be taken on the actual curved surface area of the membrane.Cricket Field Facility Building |
| 266 | New Tensile Canopy For Existing Facility Building |
| 267 | Providing & fixing 0.80 mm thick corrugated G.S. sheet roofing with zinc coating not less than 275 gm/m² on vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Tool Shed |
| 268 | Entrance Gate B/W To Facility Building |
| 269 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter of 0.80 mm thickness with zinc coating not less than 275 gm/m², with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete as per specifications and direction of Engineer-in-Charge.Tool Shed |
| 270 | Providing & fixing ridge/hip of width 60 cm overall width fabricated from 0.80 mm thick plain G.S. sheet with zinc coating no less than 275 gm/m2, fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per specifications and direction of Engineer-in-Charge.Entrance Gate B/W To Facility Building |
| 271 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications( 30 cm size )Compound Wall & Site Filling |
| 272 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 75 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical SpecificationsCompound Wall & Site Filling |
| 273 | Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.Compound Wall & Site Filling |
| 274 | Filling with earth approved material obtained from borrowpits, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.Compound Wall & Site Filling |
| 275 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Internal Driveway (Cc Road) |
| 276 | Parking & Footpath |
| 277 | Construction of granular sub-base by providing Grading VI close graded Material, spreading in uniform layers with motor grader on prepared surface, mixing by place in method rotavator at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.Internal Driveway (Cc Road) |
| 278 | Parking & Footpath |
| 279 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per section 800 of MoRTH specifications for Road & Bridge works (5th revision) and instruction of Engineer in charge.Internal Driveway (Cc Road) |
| 280 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1.Internal Driveway (Cc Road) |
| 281 | Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm.Internal Driveway (Cc Road) |
| 282 | Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408.Internal Driveway (Cc Road) |
| 283 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Parking & Footpath |
| 284 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.Parking & Footpath |
| 285 | Grass Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge.Landscape |
| 286 | SITE PREPARATIONSupplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).Landscape |
| 287 | Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).Landscape |
| 288 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) .Screened through sieve of I.S. designation 20 mmLandscape |
| 289 | Screened through sieve of I.S. designation 16 mmLandscape |
| 290 | Screened through sieve of I.S. designation 4.75 mmLandscape |
| 291 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).Landscape |
| 292 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.Landscape |
| 293 | Providing and stacking of Ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bag as per direction of the officer-incharge.Landscape |
| 294 | Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35-40 cm well developed in big size HDPE bags as per direction of the officer-in-charge.Landscape |
| 295 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts(cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deepLandscape |
| 296 | Providing & Grouting of dowel tubes / Shear keys / Joints of precast members with M-60 grade cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing / pump),curing etc. Complete as per directions of Engineer-in-charge. (The payment shall be made on the basis of actual weight of approved grout injected.)Stirrer mixed cementitious grout (non shrink) of approved make in dowel tubes / Shear keys / Joints of precast members.Ground FloorEntrance Gate B/W To Facility Building |
| 297 | Providing and fixing double-wall hollow blow mold bucket type seat ( Simple Mount) having minimum dimensions as 465mm side length x 420 mm front width x 400 mm rear height in one piece of HDPE having minimum shell thickness of 3 mm on each wall and minimum density of 0.95 gram/cm3, weight of plastic chair should not be less than 2.2 kg, chair should withstand in high temperature not less than 50°C with ultraviolet stabilizer and color fastness, having ergonomic design seat to be fixed on Concrete floor using simple mount plate by the process of grouting with bolt. Water should not accumulate on chair. Chair should have a warranty of 2 years against significant colour fading and 5 year against breakage due to manufacturing. Chair Plastic Part should have been tested with xenon –Arc exposure Test as per ISO 4892-2:2013 ,Cycle-1.The Grey Sale Rating should be (GSR) : > 4,Delta Δ E : < 3, Valid Test Certificate to be submitted The seat should pass BSEN 12520 ;2015 TEST Including loading unloading fixing, transport and all taxes excluding GST etc complete as per the direction of Engineer.Cricket Field Facility Building |
| 298 | New Tensile Canopy For Existing Facility Building |
| 299 | Directional & Fire Exit - Providing and fixing 8mm thick clear acrylic autoglow sheet with vinyl text matching to specified colour, both sideS lettering as approved. Cost to be inclusive of wastage, suspension by means of SS strings, including of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge.Cricket Field Facility Building |
| 300 | Fire Signages - Providing and fixing 8mm thick clear acrylic autoglow sheet with vinyl text matching to specified colour, both sideS lettering as approved. Cost to be inclusive of wastage, suspension by means of SS strings including of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge.Cricket Field Facility Building |
| 301 | Room SignageType - 1, Size - 450mm x 200mm made of 6mm acrylic board + vinyl/PVC sticker with stud including of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge.Cricket Field Facility Building |
| 302 | E.I. WORKDG Set(Optiprime 250*2KVA) :-Design, Supplying, Installation, Testing and Commissioning of Silent type DG Set having prime power rating of (2X250) KVA (CPCB IV+)with Inbuilt syncronisation panel at 0.8 pf at NTP conditions (Alternator directly coupled with Diesel Engine) suitable for syncronizing Panel complete in all respect and comprising of following and as per specification enclosed, suitable for outdoor installation. (to Satisfy all statutory norms of latest CPCB-IV norms)A. Alternator : Self excited, self regulated, brush less type 415 Volt 3 phase 50 Hz synchronous generator delivering 2X250 KVA at 0.8 PF (lag) at NTP condition Conforming to IS/ IEC 60034- 1, screen protected self regulated + 1% regulation, taken out for connecting through Cable along with all accessories.OEM shall be produce ARAI certificate(Make-Kirloskar (Optiprime).Engine : Four(4) stroke, Multi cylinder Turbo charged Radiator Cooled Diesel Engine of suitabe BHP operating at 1500 rpm, daily fuel tank of 690 x 2 duly calibrated including medium class MS piping for fuel piping from day tank to Engine and back, residential type silencer, AREP technology, SS flexible below for exhaust pipe and 12 V DC starting arrangement with minimum 2Nos of 12 V battery having Ampere- Hr rating as prescribed by the manufacturer of Engine along with battery charger, as required. C. Base Plate : Common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting as per standard practice of manufacturer etc. required.D. Acoustic Enclosur: The acoustic enclosure is made of 14 gauge CRCA sheet or more. The salient features of acoustic enclosure are:- The enclosure is of modular construction with the provision to assemble and dismantle easily at site finished with powder coat painting of approved colour.i) The Sheet metal components are Eleven Tank pre treated before powder coating.ii) The door are gasketed with high quality EPDM gaskets to prevent leakage of sound as well as door handles are lockable type. iii) Specially designed attenuators to control sound at air entry and exit points.iv) Adequate ventilation to meet total air requirements. v) Temprature of enclosure should not exceed beyond 5-7°C of ambient temperature.vi) Emegency shut down button from outside the enclouser.vii) Noise level; <75 DB (A) at 1 mtr Distance.Ambient Conditions: Temperature = 20 to 50 degree Celsius Relative Humidity = 95% max.Guarantee: The DG set shall be guaranteed for a period of 60 months from the date commissioning or 5000 hrs from the date of commissioning whichever occurs earlier.Governing system : electronic governer controller Fuel system: Suitable capacity fuel tanks with connected pipes lines/hoses, stand for fuel tanks, overflow pipes, drain valves, air vent valves, strainers openings for inspection and cleaning with cover, level indication in the tank with scale to indicate the fuel stored, common outlet of tanks should be connected to the engine), full flow spin-on filters to the engine, fuel pump, injectors. The initial filling of fuel (high-speed diesel). Lubricating system: oil pump, strainer, spin-on filter, pipes, intimate lube grade, the capacity of the sump, initial tank filling of lube oil & Diesel shall be provided by the vendor.Starting system :DC starter motor , battery charging alternator with in built regulator. suitable stand,suitable nos. of charged maintainace free batteries , with cable leads and terminal holders. battery make: Kirloskar. Spare parts of filters Includes Lub Oil , Fuel & Air filter to be replaced up to 1000 hrs at free of cost whenever required. Fly wheel housing,flexible coupling,coupling guard, base frame : sturdy, fabricated, welded costruction, channel iron frame for mounting the above engine and below alternator . Battery charger from mains 230V AC Starting.HSD FUEL TANK:Supply,installation,testing and commissioning of minimum 690 x 2 liter ,HSD fuel tank.Errection & Commissioning:Supplier shall be responsible for carrying out the Erection, start up testing and commissioning of the new DG Set required technical personnel and labour for the same shall be provided by the vendor. Tools, tackles, required for the same shall be a arranged by the vendor. Erection of the Stack and thermal insulation of the exhaust system is also the responsibility of the vendor.NB:-The DG Set consisit of 2 nos of 250KVA DG with AMF Synchronization panel ,and necessary arrangement as per the standard. |
| 303 | Providing and fixing bi-lingual Danger HT notice board of 250mmx200mm as specified below,made of mil;d steel at least 2mm thick & vitreous enamelled signal red color on both sides as background & with insprictions in enamelled vitreous white color on front side for lettering as required. |
| 304 | Earthing :-Supply & Fixing of Copper plate Earthing (600x600x3mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 305 | Supply & Fixing of GI plate Earthing (600x600x6mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 306 | Providing and fixing 25mm X 5 mm copper strip at 0.50 meter below ground/suraface including connection/termination with brass nut, bolt, spring, washer excavation and refilling(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) as required. |
| 307 | Providing and fixing 25mm X 5 mm GI strip at 0.50 meter below ground/suraface including connection/termination with nut, bolt, spring, washer excavation and refilling(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) as required. |
| 308 | AREA LIGHTINGSEMI MAST POLE:for Parking Area :-Supply,installation,testing and commissioning of 12M high mast shaft in two sections suitable for 55 m/sec wind speed along with head frame, luminaires carriage suitable for 6 luminaires in symmetrical arrangement and other accessories manufactured in factory. ( Bottom 360mm / Top -150mm, 3mm thickness, 445PCD, diameter of base plate 520mm including supplying of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation)along with foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template along with Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour.Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour . Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required) Approved colour after treatment along with provision of masonary pedestal duly finished with plaster and painting with GI pipe for cable entering as required.. (2nos per mast required) (Make:-Bajaj/ Utkarsh/ /Valmont/Transrail |
| 309 | SITC of 250W Outdoor Flood LED lights with polycarbonate module lens provided with silicon gasket for efficient ingree protection with silicon potted driver, IP66, IK08 , bottom opening maintanance , LPW not less than 120.Input Voltage: 85-265V AC ,Body : pressure Die cast Aluminium housing designed to act as heat sink for proper heat dissipation, IP66, CRI greater than eual to 70, burning hours 50,000 hrs, pf greater than 0.95, THD less than 10% as per the Drawing for inspection as required Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as rerquired & as per direction of Engg.-in-Charge.The luminaire should be Replacement Warranty will be 2 years . |
| 310 | LED type single dome aviation obstruction light. (Make:-Bajaj/ Utkarsh/ Vakrangee/RR ISPAT |
| 311 | STREET LIGHT: S/I/T&Commissioning of LT OUT DOOR double door cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & painted by simens gray powder coated paint is designed as G.A drawing. (FOR USE) with 63A FP MCCB, 16kA, adjustable thermal relaese, Ics=100%Icu 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, 100A Aluminium busbar, OLR,RYB,ON,OFF trip indication, 3P+N Type-II SPD 40ka alongwith 63A, 4P MCB,C series, 10kA for the incoming feeder,04 nos 16A 4P MCB,C,10KA as outgoing with 100A stud connector with Undervoltage and overvoltage voltage monitoring relay, Make of- MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200), Make of- MCCB legrand dPx3/ schneider CVS/ Siemens 3VA/ ABB Formula, Make of SPD-ABB/siemens/Schneider/Legrand/OBO/Dehn as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 5 years of acceptance of materials.The panel should be mounted on hot dip GI C channel alongwith RCC foundation.The GA Drawing shall be approved by the SEEC(R&B), Odisha, Bhubaneswar before execution of the work. |
| 312 | STREET LIGHT :-Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Bajaj/ Utkarsh/ /Valmont/Transrail as per direction of Engg. in Charge. |
| 313 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Bajaj/ Utkarsh/ /Valmont/Transrail as per direction of Engg. in Charge. |
| 314 | Supply, installation, testing and commissioning of LED Design based BIS approved LED Street Light with system power of 90W, CCT in 5700K as per ANSI) ,CRI>70, SDCM<3 , LEDs used should have a life of 50,000 burning hrs. & Lumen maintenance as per L70. The Luminaire System lumens should be >=10,800 Lumens @5700K. The fixture housing must be Made of ADC 12 PDC Aluminium housing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08. The light engine should use Metal Core PCB with high grade aluminium (AL5052) and should have a thermal conductivity of >2W/mK. The fixture should have an UV stabilized Injection moulded special PC lens optics(Glass not allowed) ensuring low glare & best in class uniformity. The light and the driver compartment should be thermally isolated by a natural airgap. Luminaire housing and optical compartment both should carry OEM's logo embossed / engraved (no stickering is allowed). The luminaire must have Integral encapsulated high efficiency electronic thermally isolated driver having a Aluminium extrusion construction with rated voltage of 100-300V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of min 6KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection. . The compartment should be bottom openable for ease of maintenance at site. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. Following documents to be submitted after award of contract: Luminaire and Driver TDS, Photometry report, Type test certificate, IP, IK, Vibration and salt spray test certificates from NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliant, BIS Certificate for Luminaires & Drivers. The warranty on light fixture shall be 5 years. (Make: PHILIPS/WIPRO/BAJAJ/Crompton/PANASONIC/LT/HAVELLS) |
| 315 | Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with street light on that foundation(Details Drawing of the foundation attached). The work shall be excuted as per the direction of EIC.The structural calculation, wind load calculation and civil foundation shall be duly approved by the competent authority from civil wing (SE/CCE/Competant authority)before execution of the work. |
| 316 | Supplying, Erection, Fixing, connection & testing of 50W LED Heritage GATE Light, Dimension of light must be Ø400mm dia and 800mm height, IP 66, IK07, amb. temp -10 to 45 degree celcious, CT 3000-5700K,,50000 HRS, CRI 70, 120 Lm/W system efficacy,driver efficiency >/ 85%,dia case aliminium housing,Clear Acrylic diffuser of Make-K-LITE Model No - 25444/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj as approved maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 317 | External Kiosk panel(Ex. Panel-1) :-Supply, installation, testing and commissioning of IP 65 cubicle type sectionalised, front operated bottom entry outdoor type Kiosk Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base channel, complete with all accessories including interconnections, earth bus etc as required.Incomer cum Outgoing :-One(1) 800A 4P MCCB 50kA with LSIG Microprocessor release with Ics=100%Icu ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) One(1) - Multifunction meter (V,A,KWHr, KW, P, F), (1)set of – 800/5A , 15VA , CL 1.0. CTs One set - Indicating lamp for ON/OFF/Trip and Phase indication with control fuse/ MCB. One(1)- Trip Push Button Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula |
| 318 | Main LT Panels :-S/I/T&Commissioning of LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 80X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with with 125A 4P MCCB, 25Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) Make of SPD -LEGRAND / Siemens/ Schneider/ABB/OBO/Dehn/ABB. Mandatory provision of cable alley is to be given. ON/OFF/TRIP indication shall be given for all the feeders.Busbar -1000 Amp Al busbar with SC rating of 36 KA suitable for operation at 415 Volt, 50 Hz, 3 Phase supply .One (1&2)-Incomer feeders each consisting of For Transformer side:One(1) -415A,800A 4P ACB 50kA with EDO TYPE ACB Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) ( Make-LEGRAND-DMX3 / Siemens-3WT Model/ Schneider- Materpact NW/ ABB- Emax2)One(1) - Multifunction meter (V,A,KWHr, KW, P, F), (1)set of – 800/5A , 15VA , CL 1.0. CTs One set - Indicating lamp for ON/OFF/Trip and Phase indication with control fuse/ MCB. One(1)- Trip Push Button For DG side:One(1) -415A,800A 4P ACB 50kA with EDO TYPE ACB Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) ( Make-LEGRAND-DMX3 / Siemens-3WT Model/ Schneider- Materpact NW/ ABB- Emax2)One(1) - Multifunction meter (V,A,KWHr, KW, P, F), (1)set of – 800/5A , 15VA , CL 1.0. CTs One set - Indicating lamp for ON/OFF/Trip and Phase indication with control fuse/ MCB. One(1)- Trip Push Button Electrical and mechanical interlocking between transformer and DG incomer should be provided.OutgoingFive(5) - Outgoing Feeders for- 04 nos Outgoing Feeders for Cricketground lighting and 01 nos spare each comprising ofOne (1) - 250 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 36 KA with adjustable Micro Processer Based Release with Ics=100% Icu (LSIG Protection) with 3 NosIndicating lamp for ON/OFF/Trip with control fuse/ MCB, 3 Nos 500/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F)( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB-Formula)One(1) - Outgoing Feeders each comprising ofOne (1) - 320 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 36 KAwith adjustable Micro Processer Based Release with Ics=100% Icu (LSIG Protection) with 3 NosIndicating lamp for ON/OFF/Trip with control fuse/ MCB, 3 Nos 320/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F)( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB-Formula).Five(5) - Outgoing Feeders for- 01 nos for Facility Building and 04 nos. spare each comprising of.One (1) - 125 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 25 KA with adjustable thermal release with Ics=100%Icu and 3 Nos Phase indicating lamps with control fuse/ MCB, 3 Nos125/5 A 15VA Cl 1.0 CTs, Digital Voltmeter, Ammeter.earth fault module( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB-Formula).One (1) -63 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 25 KA with 3 Nos Phase indicating lamps with control fuse/ MCB, 3 Nos 100/5 A 15VA Cl 1.0 CTs, Digital Voltmeter, Ammeter.earth fault module( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB-Formula)Four (04) Outgoing FeedersOne (1) - 63 Amp. 10KA 4P MCB(C-CURVE)Four (04) Outgoing FeedersOne (1) - 40 Amp. 10KA DP MCB(C-CURVE) |
| 319 | SUB PANELSSITC of Distribution Panel for facility building :-S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical panel (for facility building) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Mandatory provision of cable alley is to be given. IncomerOne (1) - 125Amp, 25 kA, 4P MCCB with adjustable thermal release with Ics=100%Icu with 3 Nos Phase indicating lamps with control fuse/ MCB, 3 Nos125/5 A 15VA Cl 1.0 CTs, Digital Voltmeter, Ammeter.earth fault module( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB-Formula)Five(5) - Outgoing Feeders for LDB , PDB,ACDB,01 nos for UPS Outgoing & SPARE each comprising ofOne (1) 63-40 Amp. 10KA 4P MCB(C-CURVE)Three(03) - Outgoing Feeders for 02 nos Gallery Distribution Boards & Spare each comprising ofOne (1) 32 Amp. 10KA 2P MCB(C-CURVE) |
| 320 | ELECTRICAL PANEL SUPPRESSION :-Supply, fixing, testing and commissioning of 5 LB Clean Agent system complete with all necessary Clean Agent FK-5-1-12 / Novec 1230 (UL listed ) gas ,fitting ,support , and accessories, connected with PESO approved DLP valve with CE & PI marked, with PESO approved Cylinder, End of Line Adaptor,Pressure Switch (UL Listed) for monitor system activation .System shall be Helium Leak Tested to 10^-7 mbar l/s.(MAKE: SUPREMEX, SEVO, FIREBOY,Honeywell) |
| 321 | Supply, fixing, testing and commissioning of Flexible Polymer Detection Tube (size 6 mm outer dia & 4mm inner dia )with all necessary fittings &supports. (UL Listed) with all necessary fitting and support (MAKE: SUPREMEX, SEVO, FIREBOY ,Honeywell) |
| 322 | Supply, fixing, testing and commissioning of Master control unit with audio visual alram with wiring to complete system operational control panel should have provision for integration with fire alram /scada/BMS system Health Monitoring Cum Alarm Panel (MAKE: SUPREMEX, SEVO, FIREBOY ,Honeywell) |
| 323 | (Cable, Cable Tray,End Termination & Cable Jointing) :-Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5C X 300 sqmm(TRANSFORMER-DG TO KIOSK PANEL) |
| 324 | 3.5C X 240 sqmm (FOR CRICKET STADIUM) |
| 325 | 3.5C X 95 sqmm(FOR Facility building) |
| 326 | 3.5C X 35 sqmm(For basketball, volleyball and archery court) |
| 327 | 4CX 16sqmm |
| 328 | Supplying & Testing of 1.1 KV grade Copper Armoured cable. Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster4CX 6 sqmm |
| 329 | 3CX 2.5 sqmm |
| 330 | Cable laying :-Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required.Above 125 Sqmm and upto 400 sqmm |
| 331 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size in the existing RCC/HUME/STONEWARE/METAL pipe as required.upto 25 Sqmm |
| 332 | Above 25 sqmm & upto 400 Sqmm |
| 333 | Supplying and laying UPVC pipe (80 Schedule) of following diameter burried in ground at appropriate depth for cable laying as required.110 mm dia |
| 334 | TERMINATION OF CABLES :-Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable).3.5C X 300 sqmm |
| 335 | 3.5C X 240 sqmm Al |
| 336 | 3.5C X 95 sqmm |
| 337 | 3.5C X 35 sqmm |
| 338 | 4CX 16 sqmm |
| 339 | Cable tray :-Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 340 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 400mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 341 | Supply, Exivation&Refilling of HDPE Pipe, 63MM Dia |
| 342 | Supply, Exivation&Refilling of HDPE Pipe, 200MM Dia |
| 343 | Supply, Exivation&Refilling of HUME Pipe, 300MM Dia |
| 344 | Supply installation of high-voltage insulating mat has a thickness of 3.0 mm, rated for maximum use voltage of 33 kV. It withstands an AC proof voltage of 36 kV and an AC dielectric strength of 65 kV, with maximum leakage current limited to 10 mA. Minimum insulation resistance (5000V megger) is 1,00,000 MΩ. Tensile strength is minimum 15 N/mm², with 250% minimum elongation. After 168 hrs aging at 70±1°C, retention is minimum 75% (tensile & elongation); after 48 hrs immersion in acid/alkali/diesel/oil, retention is minimum 80%. The mat offers low-temperature resistance and flame retardance, made of synthetic elastomer, conforming to IS 15652. complete as per direction of Eng-in-charge.(Size-10mx1m) make : mandelia insulation and transmission co./Duratuf/Raychem/Vardhman |
| 345 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 346 | Earthing :-Supply & Fixing of GI plate Earthing (600x600x6mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 347 | Providing and fixing 50mm X 5 mm GI strip at 0.50 meter below ground/suraface including connection/termination with nut, bolt, spring, washer excavation and refilling(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) as required. |
| 348 | Providing and fixing 25mm X 5 mm GI strip at 0.50 meter below ground/suraface including connection/termination with nut, bolt, spring, washer excavation and refilling(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) as required. |
| 349 | Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing along with cables etc as required. |
| 350 | FIRE EXTINGUISHER SYSTEM FOR EXTERNAL & PANEL ROOM:-Supply & Installation of 30 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x |
| 351 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire/Flameklog/Kalpex. |
| 352 | Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire/Flameklog/Kalpex. |
| 353 | Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher, ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket.Make-Safex/Fireshield/Ceasefire/Flameklog/Kalpex. |
| 354 | Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. |
| 355 | CCTV( EXTERNAL AREA ) :-SITC of 5MP IP Varifocal Bullet/Dome Camera with 1/2.7\\" Progressive Scan CMOS image sensor and motorized varifocal lens (2.8–12 mm), supporting a resolution of 2880 × 1620 or higher. The camera shall provide IR illumination up to 50/30( for dome) meters and a variable field of view approximately 107°–34° (H), 55°–19° (V), and 134°–38° (Diagonal). Minimum illumination shall be 0.004 lux with advanced imaging features including Starlight technology and WDR (120 dB) for improved low-light performance. The camera shall support multiple video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multi-stream capability including main stream up to 5MP @ 30 fps, sub-stream up to 720p @ 30 fps, and an additional third stream. The camera shall support motion detection with configurable zones and event triggers including motion detection, video tampering, scene change, network disconnection, and IP conflict. The device shall support intelligent video analytics such as face recognition, human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. It shall support network protocols including TCP/IP, HTTP, DHCP, , RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 gb( for dome), alarm I/O (1/1), audio I/O (1/1), privacy masking, and ICR auto day/night switching. The camera shall support 12V DC or PoE power supply and be housed in a metal weatherproof enclosure with IP67 protection, suitable for outdoor installation. The product shall comply with NDAA requirements and be certified with STQC, BIS, CE, FCC and RoHS or equivalent. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 356 | SITC of 64CH project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS. Make-Honeywell value series /Pelco/Axis/Bosch |
| 357 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 358 | SITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 359 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking.Make:Systimax/ Legrand/ Panduit |
| 360 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear |
| 361 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 362 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer |
| 363 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit(1 mtr length) |
| 364 | SITC of 9U/500D IP55 Out Door Pole Mount Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Netrack |
| 365 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco/ Digisol/ Netgear |
| 366 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax/ Legrand/ Panduit |
| 367 | SITC of OFC Patch Cord, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 368 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 369 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 370 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 371 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 372 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 373 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 374 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 375 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OOBO/Dehn/ABB |
| 376 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 377 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 378 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 379 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 380 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 381 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 382 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 383 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 384 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 385 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 386 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB |
| 387 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 388 | INTERNAL ELECTRIFICATION FOR FACILITY BUILDING(CRICKET STADIUM) :-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. Group-A: L.P= F.P= C.B.P= |
| 389 | Group-B: L.P= F.P= C.B.P= |
| 390 | Group-C: L.P= F.P= C.B.P= |
| 391 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 392 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 393 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 394 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 395 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 396 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 397 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 398 | Circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in MS metallic conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia metallic MS conduit (2X1.5+1X1.5) |
| 399 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 400 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 401 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X6+1X2.5) |
| 402 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 403 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 404 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 405 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 406 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 407 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.The luminaire should be Replacement Warranty will be 2 years (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 408 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.1200 mm sweep |
| 409 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 410 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow1200 CFM @ 15mm MMWG static pressure |
| 411 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 412 | 24 gauge (0.63 mm thickness) |
| 413 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 414 | UPS( FOR CCTV & EMERGENCY LIGHT ) :-Supply ,installation ,testing & commissioning of 10KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 3ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 28AH, 24 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building |
| 415 | S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for UPS OUTPUT) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.1P+N Type 2 40 kA SPD shall be installed in the incomer.20x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.In commer 1- 01 no 63A 2P MCB 10kA,C series. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Busbar-1&2 02 numbers of 100Amps copper busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 4 nos 32A 2P MCB 10kA,C . ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Instrument- (i) 02 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set digital type multifunction meter with CT for voltage, current, frequency, PF, THD indication |
| 416 | Split AC :-Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only (Category II)1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16) |
| 417 | 2.0 TR with 5 Star BEE Rating (O General-ASGG24CGWA-B/ Daikin-FTKM60XV16 /Hitachi-YOSHI 5500STXL) |
| 418 | REFRIGRANT PIPING :-Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 419 | FRAME WORKSupply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 420 | DRAIN PIPING :-Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe |
| 421 | Supply and fixing of 4kVA Voltage stabilizer (130-270V) Make-V-Guard/Microtek |
| 422 | Supply and fixing of 5kVA Voltage stabilizer (130-270V) Make-V-Guard/Microtek |
| 423 | DBS :-Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 424 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 425 | Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 426 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 427 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 428 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 429 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 430 | Supplying and fixing 32 amps rating, 230 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is1 year |
| 431 | Supplying and fixing of following sizes of heavy gauge FRLS PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Make-AKG/BEC/Precision/Anchor.20 mm |
| 432 | 25 mm |
| 433 | LAN,DATA & TELEPHONE :-SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 434 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 435 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 436 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear |
| 437 | SITC of Cat6 UTP 24 AWG 1m Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit |
| 438 | SITC of Cat6 UTP 24 AWG 2m Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit |
| 439 | Supply, installation, testing & comissioning of EPBAX System 4 P&T Lines / 2 Digital / 24 Extensions expandable up to 48 Extension having Features: Call Pickup , Call Forwarding , Direct inward Dialing Direct Outward Dialing, Calling Line Restriction etc as required. Make: MATRIX/ SYNTEL/ NEC |
| 440 | Supplying desktop telephone sets with colour ID as reqd Make-Panasonic/Beetel |
| 441 | S/f of 50 pair MDF box with 3 nos. krone module. |
| 442 | S/f of 5O pair krone box with k2 no. krone module |
| 443 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 444 | 20 Pair |
| 445 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 446 | CCTV(FACILITY BUILDING & GALLARY) :-SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 447 | SITC of 5MP IP Varifocal Bullet/Dome Camera with 1/2.7\\" Progressive Scan CMOS image sensor and motorized varifocal lens (2.8–12 mm), supporting a resolution of 2880 × 1620 or higher. The camera shall provide IR illumination up to 50/30( for dome) meters and a variable field of view approximately 107°–34° (H), 55°–19° (V), and 134°–38° (Diagonal). Minimum illumination shall be 0.004 lux with advanced imaging features including Starlight technology and WDR (120 dB) for improved low-light performance. The camera shall support multiple video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multi-stream capability including main stream up to 5MP @ 30 fps, sub-stream up to 720p @ 30 fps, and an additional third stream. The camera shall support motion detection with configurable zones and event triggers including motion detection, video tampering, scene change, network disconnection, and IP conflict. The device shall support intelligent video analytics such as face recognition, human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. It shall support network protocols including TCP/IP, HTTP, DHCP, , RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 gb( for dome), alarm I/O (1/1), audio I/O (1/1), privacy masking, and ICR auto day/night switching. The camera shall support 12V DC or PoE power supply and be housed in a metal weatherproof enclosure with IP67 protection, suitable for outdoor installation. The product shall comply with NDAA requirements and be certified with STQC, BIS, CE, FCC and RoHS or equivalent. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 448 | SITC of 64CH project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS. Make-Honeywell value series /Pelco/Axis/Bosch |
| 449 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear |
| 450 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 451 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 452 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer |
| 453 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 454 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr) |
| 455 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 456 | FIRE ALARM SYSTEM :-Supply, installation, testing and commissioning of Manual Fire AlarmSystem-:Supply, installation, testing and commissioning of Conventional type Main Fire Alarm Control Panel (FACP), the panel shall be conventional type fire detection and alarm system with capacity of 4 zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display complete accessories.Make-Honeywell/Siemens/Bosch/Edward/GST/Schneider |
| 457 | Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. Make-Honeywell/Siemens/Bosch/Edward/GST/Schneider |
| 458 | Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-Honeywell/Siemens/Bosch/Edward/GST/Schneider Please Enable Macros to View BoQ information |
| 459 | Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-Honeywell/Siemens/Bosch/Edward/GST/Schneider Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender