Tender For Special Repair To Bldg No Pn 432 (Ashwamedh Hall) At Hq 16 Corps Under Ge Nagrota
Tender Overview
Project Description
Tender For Special Repair To Bldg No Pn 432 (Ashwamedh Hall) At Hq 16 Corps Under Ge Nagrota
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Aug-2026 | Amendment to tender documents | Other | 20-Aug-2026 |
| 2 | 20-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Aug-2026 |
| 3 | 27-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and directed. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm each and n exc 4 sqm and removing from site complete all as specified and directed. |
| 3 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed. |
| 4 | Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided complete all as specified and directed. |
| 5 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specified and directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. complete all as specified and directed. |
| 8 | M & L For Broken stone hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 9 | S&F in repair 12mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes, SS handles for doors of required size complete all as specified and directed. |
| 10 | S&F 40mm thick 1st class teak wood door with required design on front and back side as directed by GE and the design should be approved by GE before executing the work, with chowkhat including 300mm long SS handle 2 No. for each door, tower bolt, sliding bolt of required size complete all as specified and directed. |
| 11 | S & F Acoustic Door of 56 mm achieving sound reduction of upto 50 STC. Double layers of 8mm water proof Acoustic Ply with Dampner Sheet and double layer of 10mm compressed insulation and Single layer of Sound Dampner 1218x1218 mm x 12mm made of 10 mm compressed wood Fiber cement composites 1250Kg/m3 and 2mm dampner sheet having 37 STC as per ISO 140 (partIII) - 1995). Door frame will be made of teak wood (Sudan Teak). Three side frame and drop seal below will be provided along with the door with high load bearing hinges complete all as specified and directed. Note: Contractor will have to produce purchase vouchers and test certificate for sound reduction at the time of RAR/Final bill. |
| 12 | S&F powder coated aluminium frame work (min thickness of powder coating 50 micron) for doors, windows, ventiltors and partition, (sliding/openable/fix doors, windows, ventilator), etc with one, two or more rebates (reqd as per site), section weighing not less than 0.55 kg/m, including joining cleat for fixing with dash fasteners of required dia and size, incl filling up gaps at junctions, i.e top, bottoms and sides etc complete all as specified and directed. |
| 13 | S&F powder coated aluminium window and ventilator shutters, sliding/openable/fixed (as per required at site) type without sash bar, aluminium section weighing 0.55 kg/m, including necessary locking arrangement, guide wheels, joining cleats, glazing clips rubber packing anodised alu snap beading screws etc complete all as specified and directed. |
| 14 | S&F aluminium power coated door shutters (sliding/openable/fixed (as per required at site), aluminium section weighing 0.55 Kg/m including necesssary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door, pad lock, hinges, anodised aluminium snap beading screws etc complete all as specified and directed. |
| 15 | S&F double action floor spring hudraulically regulated made up of min 1.25mm thick aluminium alloy sheet foundation box, main body with stailess steel cover governing pivot made of brass other made of mild steel heavy duty, complete all as specified and directed. |
| 16 | S&F for sheet glass plain/coloured 3mm thick best quality and glazing with rubber packing, screws or glass putty in squares n. exc 0.5 Sqm each pane complete all as specified and directed. |
| 17 | S & F for stainless steel wire cloth of 0.36mm dia wire and average width of aperture 1.40mm & fixed with tacks or screws, wire staples, etc complete all as specified and directed. |
| 18 | S&F aluminium anodised grill 6m thick fixed to aluminium window with and including 'H' type aluminium frames of size 34mm x 11mm complete all as specified and directed. |
| 19 | S& F Floor door stopper of aluminium alloy body and tongue ,anodised ,with hard drawn steel spring, fixed in floor overall length of cover plate 140mm complete all as specified and directed. |
| 20 | S&F in repair fluted PCP (Polymer Composite Panel) wall/ceiling panels of approved make and shade, having fluted/grooved surface texture, made of high-quality polymer composite material, termite-proof, water-resistant and fire-retardant properties, including necessary framework of aluminium/galvanized iron sections, backing supports, screws, fasteners, adhesives, trims, mouldings and finishing accessories, complete all as specified and directed. |
| 21 | S & F in repairs false ceiling at all heights with GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRCO.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (min) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanized iron section of 0.33mm thick ( galvanized @ 12a grams per sqm incl both sides ) comprising of main T runners of size 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling usung galvanized mild steel items (galvanizing @ 80 grams per Sqm) ie 50mm long 8mm outer diater M-6 dash fasteners 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and complete all as specified and directed. Note: Make to be approved by GE before executing the work. |
| 22 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in cement mortor 1:6, etc complete all as specified and directed. |
| 23 | M & L for brick work with sub class 'B' modular bricks, straight or curved on plan to any radius built in CM 1:4 in half brick thick walls complete all as specified and directed. |
| 24 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick or concrete surface with liquid water proofing compound @ 200 ml per bag finished even and smooth without using extra cement complete all as specified and directed. (Note:- Liquid water proofing compound to be measured and paid separately) |
| 26 | M&L for rendering 15mm thick in cement mortar 1:4 in layer ( 10 mm + 5mm ) mixed with PD proof 101 LW (OR +) of Dr fixit integral WP admixture (or equivalent from list of makes) @ 200 ml/bag of cement over two coats of super latex 302 of Dr Fixit (or equivalent from list of makes) in the ration 1:4:7 (one part super latex 302, 4 part water and 7 part cement) @ 1050 kg of homogeneous mixture per sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and as directed.Note : Water Proofing compound shall be measured and paid separately |
| 27 | M&L for rendering 5mm thick in ceiling CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | Supply only integral water proofing compound complete all as specified and directed. |
| 29 | M&L for plain cement concrete 1:4:8, type D2( using 40mm graded crushed stone aggregate) 75mm thick as in sub base of floor complete all as specified and directed. |
| 30 | M & L 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) for levelling course in floors complete all as specified and directed. |
| 31 | M&L for vitrified light shade floor tiles 10mm thick (square or rectangular) area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface with and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed. |
| 32 | All as per Srl item No. 31 above but as in skirting/ dado etc with and including 10mm thik backing coat in cement mortar 1:4 an wall complete all as specified and directed. |
| 33 | M & L for non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed. |
| 34 | M&L for glazed ceramic coloured wall tiles (textured and design as required) in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified and directed. |
| 35 | M & L for preparing new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant cement primer and over a coat of 2 to 3mm thick wall care putty complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 36 | Material and Labour for apply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer on new surfaces including 2 -3 mm plaster of paris putty to prepare the surface even and smooth thick wall putty, complete all as specified and directed. Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 37 | M & L for preparing new plastered surface on ceiling and applying two coats of distemper oil emulsion over a coat of alkali resistant cement primer and over a coat of 2 to 3mm thick wall care putty complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 38 | M&L for preparation of old decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorescent salt, trading oil and greasy spots and applying two coat of Oil bound distemper on walls over 2mm thick plaster of paris putty complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 39 | M&L for preparation of old decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasy spots and finishing walls with Acrylic Smooth exterior paint of required shade as approved by GE with two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 3mm thick cement based wall care putty including necessary scaffolding, etc complete all as specified and directed.Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b) The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no claim on account of misunderstanding or otherwise shall be admissible on this account. (c) The painting is to be done in one or more shades as approved by GE. |
| 40 | M&L for preparation of old decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorescent salt, trading oil and greasy spots and applying two coat of Oil bound distemper on ceiling over 2mm thick plaster of paris putty complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 41 | M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with providing 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 42 | M & L or Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of any types complete all as speciifed and directed. |
| 43 | M&L for plain cement concrete 1:3:6, type B1( using 20mm graded crushed stone aggregate) 75mm thick as in plinth protection complete all as specified and directed. |
| 44 | Demolition of cement or lime concret in any despription along with tarfelt treatment in sunken portion / roof and cement mortar bedding from roof removal rubbish outside MoD land complete all as specified and directed. |
| 45 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sunken portion, subbase, etc complete all as specified and directed. |
| 46 | M&L for rendering 10mm thick in CM 1:4 on roof suraces with liquid water proofing compound @ 200 ml per bag finished even and smooth without using extra cement complete all as specified and directed. |
| 47 | M&L for water proofing treatment to sunken portition / roof etc. in following sequence:- (i) Properly cleaning and drying the surface (ii) Applying a coat of bitumen primer @ 1.2Kg/Sqm and primer shall be allowed to dry over night. (iii) Laying APP based modified water proofing membrane of weight not less than 3kg per sqm and thickness not less than 3 mm, with 100mm overlaps, sealed and bonded to the surface by 'torchon' method (iv) Applying two coat of bituminous based aluminum painting @ 0.15 kg/Sqm each coat on water proofing treatment with preparation of surfaces complete all as specified and directed. |
| 48 | S & F in repair Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete all as specified and directed. |
| 49 | S & F in repair Vitreous China valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 50 | S & F in repair vitreous China urinal Half stall type, white with grating and unions for discharge pipe including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement complete all as specified and directed. |
| 51 | S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and directed. Note :- Pillar tap shall be measured as supply only under respective item |
| 52 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)Vitreous China wash down water closet pan semi pedestal pattern(Anglo Indian type), white (excluding fixing bolts, flushing cistern and flush pipe(excluding flushing cistern and flush pipes) including connection to trap and to flush pipe etc and lime concrete bedding including 'P' or 'S' trap complete all as specified and directed. |
| 53 | S & F in repairs PVC (SWR) nani trap / floor trap plain or multi with stainless steel grating incl joining to waste pipe with solvent cement joint dia of outlet 75mm bore complete all as specified and directed. |
| 54 | S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 55 | S&F in repair 75mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 56 | S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 57 | S & F in repair 75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 58 | S & F in repairs 110mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls / floor or in trenches complete all as specified and directed. |
| 59 | S & F in repairs 75mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls / floor or in trenches complete all as specified and directed. |
| 60 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed. |
| 61 | Taking up or down 15 mm dia old serviceable / unserviceable steel tubing any grade and connections cleaning for re-fixing or removal to store complete all as specified and directed. |
| 62 | All as per Srl item no 61 above but 20mm bore complete all as specified and as directed. |
| 63 | S&F steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc ,for 15mm bore pipes complete all as specified and directed. |
| 64 | All as per srl item no 63 above but 20mm bore complete all as specified and as directed. |
| 65 | S&F in repair for 15mm bore bib taps chromium plated with crutch or butterfly handle ,screwed down , screwed for iron pipes or brass ferrule complete all as specified and directed. |
| 66 | S&F in repair CP angle stop cock of 15mm bore screwed down for high pressure with crutch or butter fly handle, screwed both end for iron pipes complete all as specified and directed. |
| 67 | S&F in repair CP mixer for mixing hot & cold water screwed down for iron pipe 15mm bore complete all as specified and directed. |
| 68 | S&F health faucet with 1 meter long easy flex tube in chrome finish & wall hook, complete all as specified and directed. |
| 69 | S&F in repair 125 mm size chromium plated shower rose with siwel joint suitable for 15 mm bore GI pipes complete all as specified and directed. |
| 70 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 450 mm long complete all as specified and directed. |
| 71 | S& F in repair Rotational moulded Polyethylene trippled layer water storage tank 1000 liters capacity (cylidrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I incl brass float valve 20mm dia and dismantling water tank complete all as specified and directed. |
| 72 | Shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300 grams) complete all as specified and directed. |
| 73 | S&F in repair stop valves fancy type chromium plated with long shanks fixed with 15 mm dia bore pipes complete all as specified and directed. |
| 74 | M & L for high strength steel deformed TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping columns,hookings ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, etc complete all as specified and directed. |
| 75 | M & L for formwork fair and finished surfaces to sides and soffits of floor or roof beam, beam hauchings, bands, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc complete all as specified and directed. |
| 76 | M&L Reinforced Cement Concrete M-25 using 20 mm graded crushed stone aggregate as in beams, bands, cantilvers, bressummers, linters, chajjas, etc over 1.5m span etc complete all as specified and directed. |
| 77 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar complete all as specified and directed. |
| 78 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of 150 mm bore pipes in cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate) after they are laid and tested complete all as specified and directed. |
| 79 | M&L for 150 mm bore salt glazed stone were (SGSW) drain pipe grade 'A' laid to slope in tranches and jointed in cement mortar (1:1) including necessary testing for ensuring teak proofing complete all as specified and directed. |
| 80 | Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and directed. |
| 81 | M&L for Cement concrete chequered tiles of size 30 cm x 30 cm x 25 mm thick, set, jointed and pointed in neat cement slurry (with grey cement and pigment) Incl 20mm thick screed or screed bedding in cement mortar 1:4 as in floors complete all as specified and directed. |
| 82 | S & F steel work in tubular trussles,purlins,rafters,tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washers etc. complete using ERW or induction butt welded tubes confirming to Fe 410W grade E 250 quality B, etc complete all as specified and directed. |
| 83 | S & F 0.50mm thick (including coated thickness) Pre-colour, pre-profiled ( Galvalume ) sheets of required colour and design having tensile strength of 550 Mpa as in roof, wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer/ profile maker instruction complete all as specified and directed. |
| 84 | S & F for precast cement concrete type B-1 (1:2:4) (20mm graded crushed stone aggregate ) as in kerb and edging to road and footh path, etc including chamfered, weathering, throating etc and setting in CM (1:4) complete all as specified and directed. |
| 85 | S & F MS framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces and stair case etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to fe 290 Gde E-165 complete all as specified and directed. |
| 86 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 87 | Taking down carefully copper /aluminium point wiring (light, fan, bell, socket and power) complete including all switch sockets ceiling roses switch boards regulator etc and disposal under schedule of credit and making good disturbed surfaces complete all as specified and directed. |
| 88 | Taking down carefully ceiling/exhaust fan any sweep any size, removing blades & deposited to store, complete all as speicified and directed. |
| 89 | Taking down MCB DB of any size incl MCBs of any size/any make and disposal under schedule of credit and making good disturbed surfaces complete all as speicified and directed. |
| 90 | Taking down carefully LT Panel and Change Over complete all as speicified and directed. |
| 91 | Taking down carefully Split AC(outer and Inner Unit) capacity upto 2 TR from existing Location and deposited in Safe custody(MES Store) very carefully and Safely, complete all as speicified and directed. |
| 92 | M&L for Point wiring for One light point controlled by one switch 5 Amp SP one-way complete with 1.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including PVC concealed conduit (medium quality) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including suitable size MS modular sunken box with Modular plate and support frame for fixing modular switches,sockets,regulators and machine made brass screw and washers etc complete all as specified and directed for one light point controlled by one one way switch. |
| 93 | All as per srl item No 92 above but for one ceiling fan/exhaust fan point |
| 94 | All as per srl item No 92 above but for one 3 pin 5 amp socket on same board |
| 95 | All as per srl item No 92 above but for one 3 pin 5 amp socket on indipendent board |
| 96 | All as per srl item No 92 above but with 2.5 sqmm copper conductor for 15 amp socket with 2.5 sqmm earth continuity conductor |
| 97 | All as per srl item No 92 above but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for one for one one MCB plug and socket point (For AC ) complete all as specified and directed. |
| 98 | S & F Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified and directed. |
| 99 | S & F Modular socket 3 pin 5/6 Amps suitable for 2 Module complete all as specified and directed. |
| 100 | S & F Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified and directed. |
| 101 | S & F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and directed. |
| 102 | S & F ceiling rose surface bakelite 65 x 50 mm, two to three terminals complete all as specified and directed. |
| 103 | S & F Fan step regulator 100 watt 2 module complete all as specified and directed. |
| 104 | Supply and fixing LED lights fitting 1x 10W batten mirror light complete all as specified and directed. |
| 105 | Supply and fixing LED ceiling lights fitting 36W, Recess Mounted, 2x2 feet, warm, Neutral & cool white colour complete all as specified and directed. |
| 106 | Supplying, installation, commissioning and testing of Lt switch gear control panel board 440 volt AC 3 phase 4 wire for indoor installation \\"KIOSK TYPE\\" with sloping canopy fabricated out of steel sections i.e CRCA sheet 3.15 mm thick (14 SWG), angle / channel and flat iron sections of suitable size with opening on front, door in two halves fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard, with phosphatised powder coating painting externally and internally to protect against corrosion. The panel shall be mounted on suitable size of channel section having ground clearance 60cms from grouting bolts, conforming to IEC 60 439 complete all as specified and directed duly incorporated with following accessories: -(a) Bus bar chamber with electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators 4 strip of suitable length for current rating 250 Amps. (b) MCCB 4 pole 415 V AC, current rating 125 amps , breaking cap 25 KA at 415 volts Ics=100% of Icu - 01 Nos (Incomming). (c) MCCB 4 pole 415 V AC, current rating 63 amps , breaking cap 25 KA at 415 volts -05 Nos (outgoing) (d) On load Change over switch 125 Amp - 01 Nos. (e) Multifunction meter for showing Voltage,current, Frequecy, Power factor & power etc. (f) Voltmeter selector switch, type SG 101C, 10 amps 3 pole (RY-YB-BR-OFF-RN-YN-BN) = 01 Nos. (g) Ammeter selector switch type SG 101C 10 amps 3 pole = (R-Y-B-OFF) = 01 Nos. (h) Indication pilot light to operate on direct supply 230 V AC with 2.4Watt bulb (R,Y,G) with smooth lens = 03 Nos. (i) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron.(j) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 400/5 amps, 15 VA accuracy class - 1 = 01 (set of three) |
| 107 | Supply & fixing Changeover Switch 4 pole , 415 volt AC, 63 Amp, three position, Manual operation complete all as specified and directed. |
| 108 | Supply and fixing exhaust fan, PVC body heavy duty AC single Phase 230V of size 250/300mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 109 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep Minimum air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including making connections with three core PVC insulated and PVC sheathed flexible copper conductor cable from ceiling rose to fan complete all as specified and directed. |
| 110 | S&F sheet metal enclosure double door for distribution board factory made for MCCB DB load link VTPN 4 way,IP-43, suitable for MCCBas incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar including 125 A MCCB as incomer 16 KA complete, fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all at site and including taking out of exsing UNSV DB with MCBs complete all as specified and directed. |
| 111 | S&F MCCB 125A 4 Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as specified and directed. |
| 112 | S&F sheet metal enclosure for DB's , MCB DB SPN 12 way, IP-43, double door complete all as specified and directed. |
| 113 | S&F sheet metal enclosure for DB's , MCB DB SPN 8 way, IP-43, double door complete all as specified and directed. |
| 114 | S&F Single pole and neutral Modular enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amps, 10 KA 'C' Series complete all as specified and directed. |
| 115 | S&F outdoor unit mounting bracket ,Robustt heavy duty Split AC stand -pack of 2,rust proof iron ,support upto 200 kg weight with necessary wall fittings complete all as specified and directed. |
| 116 | S & F MCB SPN 63 amp rating 240V 10 KA 'C' curve in the MCB DB complete all as specified and directed. |
| 117 | Supply and fixing in replacement of MCB SP 240 Volts, 6 to 32 Amps complete all as specified and directed. |
| 118 | M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 06 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 06 sq mm as earth continuity conductor connected to commen earth and earth dolly complete incl taking out existing UNSV service connections complete all as specified and directed.Note: Two runs of 6 Sqmm FRLS PVC insulated unsheathed 1100 volts grade cable and One run of PVC conduit shall constitute as 1 RM for the measurement purpose. |
| 119 | S & F Sub main wiring with PVC insulated, FRLS cable 4 single core 10 Sq mm 1100 V grade with stranded copper conductor on and incl PVC rigid non metalic conduit (ISI marked) in concealed incl all specials like joint, elbow , Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 10 sq mm for earth continuityconductor complete all as specified and directed.Note: Four runs of 10Sqmm FRLS PVC insulated copper conductor, single core cable shall constitute as 1 RM for the measurement purpose. |
| 120 | M&L XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq mm, 2 core complete all as specified and directed. |
| 121 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.Note: If cable is above Ground then should be anchorage with clamp and necessary screws. |
| 122 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.Note: If cable is above Ground then should be anchorage with clamp and necessary screws. |
| 123 | M&L of DWC pipe for protection to 40 sq mm underground cable complete all as specified and directed. |
| 124 | Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables complete all as specified and directed. |
| 125 | Returning, filling, including spreading, levelling, watring and well ramming in layers not exc. 25 cm complete all as specified and directed. |
| 126 | Refixing of old Split AC Capacity 1.5/2 TR after servicing, Leakage testing retrived from item Ser No 91 above but including necessary connection and good Surface with new copper tubes and insulation sleeves with gas charging(R-22/R-32) complete all as specified and directed. |
| 127 | Supplying and fixing hot dipped Galvanized Iron Cable Tray size 300 mm width x 62.5 mm depth x 2.0 mm thickness (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in Convenient sections, joined with connnectors, suspended from the ceiling with two numbers GI Suspenders integarted circuit base of suitable size GI angle, GI bolts & nuts, Fastner etc required complete all as specified and directed. |
| 128 | Supplying and fixing hot dipped Galvanized Iron Cable Tray size 150 mm width x50 mm depth x1.6 mm thickness (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in Convenient sections, joined with connnectors, suspended from the ceiling with two numbers GI Suspenders integrated circuit base of suitable size GI angle,GI bolts & nuts, Fastner etc required complete all as specified and directed. |
| 129 | Earthing complete with GI earth plate 60cm ×60cm ×6 mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanised iron strip 32X6 mm as Earthing Lead by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire on earthing point all as specified and testing on completion, including provision of GI earth lead wire protected by 40 mm dia GI light grade protection pipe from test point to main board and 20 mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender