Tender For special Repair To Furniture Yard Of Bso Of Age B/R And Age E/M Under Ge Tenga
Tender Value
38.70 Lakhs
Estimated cost
Bid Submission
21 Aug 2026
4 days left
EMD
77400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kameng → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Furniture Yard Of Bso Of Age B/R And Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting of any thickness as in roof coverings complete all as specified and directed. |
| 2 | Fixing only 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws and washers, in roofs, walls etc. with grade of zinc coating 275 gsm complete all as specified and as directed. |
| 3 | S&F Pre-Painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour havimg testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 4 | S&F Pre-Painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour havimg testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 5 | Demolition floor, hearth or tiling including cement mortar bedding (but not backing)), removing serviceable tiles to store and rubbish off the premises all as specified. |
| 6 | M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles . |
| 7 | M&L for light shade vitrified tiles 10mm thick (square/rectangular) polished, area of each tile not exceeding .36 sqm,in floors etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. |
| 8 | M & L for applying two coat of synthetic enamel paint over a coat of red oxide primer to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of new steel surfaces. |
| 9 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 10 | Dismantling wrought iron or mild steel work of any description |
| 11 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Gde-Fe 410-W (Gde E- 250) quality A.complete as specified. |
| 12 | Taking down cement plaster on brick, concrete stone surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. |
| 13 | Demolition of precast cement concrete articles and precast concrete block walling built in cement mortar |
| 14 | M & L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and using PCC type C-1, 1:3:6 (20mm graded agg) and setting in cement mortar 1:6 complete. |
| 15 | M & L 15 mm thick rendering in cement mortar 1:6 on brick or concrete surfaces finished even & smooth without using extra cement |
| 16 | M & L 10 mm thick rendering in cement mortar 1:6 on brick or concrete surfaces finished even & smooth without using extra cement |
| 17 | Material and labour Preparing newly plastered wall surfaces and applying Two coats of cement base paint on wall surfaces over one coat of alkali resistance primer |
| 18 | Material and labour for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening primer. |
| 19 | Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 20 | Demolition of cement concrete (unreinforced) in any description not exc 15 cm thickness (below or above ground level) |
| 21 | M & L for 100 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 22 | M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:4 for laying floor finishes |
| 23 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete. |
| 24 | Dismantling of wall and ceiling board or insulation boards/slabs/blanckets/any thickness including cover fillets |
| 25 | S&F for anodised aluminium snap grid of size 605X605X mm frame work for false ceiling with aluminium anodized section size, wall angle 40mm X25mmX2mm thk, main/cross tee-section 36.5 X 25 X 1.4mm and 23.5mm X 26.4mm 1.4mm and susupended with 6mm dia GI wire respectively with and including 8mm thk laminated Gypssum board fixed to aluminium snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer's instructions complete all as specified and as directed by Engineer -in-charge make:(i) Aluminium section : Valco,HINDALCO, JINDAL (iI) Gypsum Board: GYPSUM IND LTD,SAINT GOBAIN |
| 26 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm |
| 27 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm. |
| 28 | S & F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete |
| 29 | S&F 30mm flush shutters, solid core construction with particle board core and plywood face panels, commercial type on both side and both face is covered with decorative face veneer with lipping/frame tp match all as completed and specified as directed. |
| 30 | S & F 30mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc but divided into squares, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads etc for securing glass etc sizes of members of shutters as specified in SSR Part I section 8 clause 8.24(a) supplied and fitted to chowkhats |
| 31 | S&F MS window guard bars, window frames etc articles confirming to Fe 410-0 or Fe 310-0. |
| 32 | S & F 100mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 33 | S & F 75mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 34 | S& F Aluminium anodised barrel tower bolts 150mm long of extruded section and fixed |
| 35 | S& F Aluminium anodised barrel tower bolts 100mm long of extruded section and fixed |
| 36 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised |
| 37 | S & F 100mm size extruded aluminium alloy handles, fabricated type anodised |
| 38 | S & F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed |
| 39 | S&F pre coated mild steel floor door stopper ,tongue anodized 140mm length including vulcanised rubber piece |
| 40 | S & F GI steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm etc all as specified. |
| 41 | S&F sheet glass 3mm thick ordinary quality and glazing with oil putty in squares n exc 0.50 Sqm in each pane. |
| 42 | M&L for 75 mm thick plain cement concrete type C-2, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement. |
| 43 | S&F of Stainless steel wind driven Turbo ventilator 600mm fan dia using best grade material, High durability , high performance, finely finished any colour suitable to fixed with corrugulated PPGI/CGI sheet, standard size complete all specified and directed. |
| 44 | Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 45 | All as per item No. 44 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 46 | All as per item No. 44 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 47 | All as per item No. 44 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified. |
| 48 | S&F Socket outlet 2 in 1, 3 pin, 6 Amp flush type |
| 49 | S&F Socket outlet 2 in 1, 3 pin, 6 and 16 Amp flush type |
| 50 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 16 Amp, 240 Volts complete all as specified & directed. |
| 51 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 52 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified & directed. |
| 53 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type (warm/white) with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 54 | S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts, 50 Hz complete all as specified and directed. |
| 55 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, (warm/white), 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed. |
| 56 | Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding of sweep 250 mm complete all as specifed and directed. |
| 57 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed. |
| 58 | S&F in replacement of distribution board vertical type TPN 415 Volt for fixing MCB/Isolator as incomer, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed. |
| 59 | Supply and fix sheet metal enclosures for double door DBs when MCBs to be used 230 volts 12 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 60 | S&F MCB TPN having breaking capacity 10KA, 'C' curve, 40-100 Amps, 415 V complete all as specified and directed. |
| 61 | S&F MCB SPN having breaking capacity 10KA, 'C' curve, 40 Amps, 240 V complete all as specified and directed. |
| 62 | S&F MCB SP having breaking capacity 10KA,'C' curve, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 63 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 64 | M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected all as specified or indicated. Earth strip protected by GI pipe 40mm bore (medium grade) and connected to main switch board or main control board and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of 20 mm dia medium grade GI Pipe for watering complete all specified and directed. |
| 65 | S & F incl leakage testing galvanised steel water tubing medium grade 50 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. |
| 66 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 50 Sqmm 3.5 core complete all as specified and directed. |
| 67 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out complete all as specified and as directed. |
| 68 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 69 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 70 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 71 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete all as specified and directed. |
| 72 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following (a) Aluminium bus bar four Nos 500 Amps each fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:-(c) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 Nos (Ics=Icu=100%)(d) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 03 Nos (Ics=Icu=100%)(e) MCB TPN 40A, 10 KA, 'C' curve, 415 Volts - 02 Nos(f) MCB SPN 40A, 10 KA, 'C' curve, 220 Volts - 03 Nos |
| 73 | (g) Multifunctional Intelligent Panel Meter digital type for measuring 3 Phase Voltage, Current, Frequency, PF,kW, kVA,kVAR, kWh, kVAh, kVARh with Communication, accuracy class 1.0, 2 Output Contact for trip, Conforming to IEC 62053-21 along with connected CTs (h) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU and cable connection will be done by proper cable gland of required sizes. (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel |
| 74 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 75 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. |
| 76 | Taking down sub main wiring of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender