Tender For Provn Of Certain Minor Works (Mw-01) (E/M) & (Mw-04) (B/R) At Air Force Station Highground Under Age(I) Highground
Tender Overview
Project Description
Tender for Provn Of Certain Minor Works (Mw-01) (E/M) & (Mw-04) (B/R) At Air Force Station Highground Under Age(I) Highground
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2026 | Corr 1 | Date | 28-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation over areas, not exceeding 1.5 m deep and getting out soft/ loose soil complete all as specified and directed. |
| 2 | Surface excavation(not exceeding) 30cm deep and averaging15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated/ scarified material (soil) exceeding 250 metre but not exceeding 1 km and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 4 | Material & Labour for hardcore of guage n exc 63mm deposited spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface broken bricks complete all as specified and directed. |
| 5 | Material and Labour for Cement concrete 1:4:8 type D2 using 40mm graded stone aggregate in floors and paving, 100 mm thick, laid in panels complete all as specified and directed. |
| 6 | Material and Labour for providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawn, drive ways or light traffic parking etc; of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand,compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 7 | Material and Labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawn, drive ways or light traffic parking etc; of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand,compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 8 | Material and Labour for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in kerb stones rounded or chamfered on edge including necessary form work complete all as specified and directed. |
| 9 | Material and Labour for providing cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) in lintel upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, stringcourses lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates,kerbs including weathering slightly rounded or chemfered angles and throating complete all as specified and directed. |
| 10 | Material and Labour for point wiring surface/concealed type (as per site requirement) with 3 x 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable (phase, neutral & earth wire), earth wire shall be connected to common earth and earth duly with suitable copper lugs drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, 1.60 mm thick GI modular metal flush box with plastic laminated sheet cover or surface mounting plastic/ PVC boxes suitable for modular switches/ sockets with cover plates (modular type), blanking plates, brass screws, cup washers, gypsum screws and connected items including all cutting/ chases etc in walls/ wall panels and making good to the disturbed surfaces to match the existing complete all as specified and as directed. |
| 11 | Supply & Fix wall mounting fan 400 mm sweep, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, ABS body incl connection complete all as specified and directed. |
| 12 | Supply & fix Air Circulator wall fans 230 volts single phase oscillating 600 mm sweep metalic body and frame with three nos of blades, three speed suitable for wall mounting complete all as specified and as directed. |
| 13 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 14 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 15 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and directed. |
| 16 | Material & Labour for Modular switch 1 way 6A, 1 module complete all as specified and as directed. |
| 17 | Supply & Fix for modular socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed. |
| 18 | Material and labour for sub main wiring with two single core PVC insulated , unsheathed stranded copper conductor cable FRLS 4 sqmm drawing in concealed conduit not less than 25 mm dia with accy and making good the disturbed surface incl one additional PVC insulated , stranded copper conductor FRLS of 4.0 sqmm, green colour for earth continuity conductor incl taking down of unsv sub main wiring complete all as specified and directed. |
| 19 | Material and labour for sub main wiring with two single core PVC insulated , unsheathed stranded copper conductor cable FRLS 2.5 sqmm drawing in concealed conduit not less than 25 mm dia with accy and making good the disturbed surface incl one additional PVC insulated , stranded copper conductor FRLS of 2.5 sqmm, green colour for earth continuity conductor incl taking down of unsv sub main wiring complete all as specified and directed. |
| 20 | Supply and fix sheet metal enclosures distribution board SPN 4 ways double door , 200 amp bus bar, IP 43 protection, 240 volts, with shrouded neutral bar & insulated bus bar and earth link, suitable for MCBs/ RCBOs as incomer and out going complete dully grouted on the wall (flush) incl dismantling and taking down old unsv and making connections with suitable size of lugs and making good the disturbed surface matchig with existing surface complete all as specified and directed. |
| 21 | Supply and fix MCB single pole 240 volts, 50Hz , breaking capacity 10KA, C curve 6A to 32A, ISI marked complete all as specified and as directed. |
| 22 | Supply and fix MCB SPN 240 volts, 50Hz, breaking capacity 10KA, c curve 32 A, ISI marked complete all as specified and as directed. |
| 23 | M&L flame proof, zone I & II, Gas group IIA/IIB, weatherproof point wiring for one light or fan point controlled by one switch using approved colour coding as per IS with zero halogen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheathed flexible copper conductor cable 1.5 sqmm (nominal area) single core 1100 volts grade in and including (ERW) stove enamelled conduit of required size but not less than 25mm dia, flame proof, weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheathed flexible copper conductor cable 1.5 sqmm (nominal area) single core 1100 Volts grade as earth continuity conductor complete all as specified and directed. |
| 24 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 25 | Supply and Fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed. |
| 26 | Note: The total amount shall subject to adjustment of credit of Rs 00 for old Materials as per Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender