Public Administrative Department Government Departments Closing in 12 days TDR #56763522

Tender For Installation Work Of Astronomy Laboratory At Higher Primary School In Urwa, Vikash Khand-Kidwai Nagar Under Basic Education Under Ssc Scheme Kanpur Nagar.

Issued by Government Departments · Kanpur Nagar, Uttar Pradesh
Tender Value
2.62 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
12 days left
EMD
2700
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Installation Work Of Astronomy Laboratory At Higher Primary School In Urwa, Vikash Khand-Kidwai Nagar Under Basic Education Under Ssc Scheme Kanpur Nagar.

BOQ

Name of Work:- C.S.R.YOJNA KANPUR NAGAR ME BASIK SHIKSHA KE ANTARGAT HIGHER PRIMIRY SCHOOL PAR URWA ,VIKASH KHAND-KIDWAI NAGAR ME ASTRONOMY LABORATORY KA INSTALLATION WORK
Sl. No. Item Description
1Dismantling old or scerting racking out points and clearing the surface for plaster 1 including disposal of Unserviceable of rubishto the dumoping ground with in 50 meters Leads. D.S.R.No. 15.56
212 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1) 2 cement: 6 coarse sand) including cost of all material, labour, T&P etc. required for proper completion of work. DSR NO. 13.4.2
3Removing White and colour wash by scrapping and sand papering and preapring the surface smooth including necessary repairs to scratches etc complete DSR No. 13.88
4Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR-13.80
5Distempering with Ist quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: 13.41.1
6Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two 6 coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete 1 application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineerin- Charge. DSR 22.22A
7Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood 7 and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 9.20.1
8Providing and fixing bright finished brass tower bolts (barrel type) withnecessary screws etc. complete:200x10 mm DSR 9.74.2
9Providing and fixing bright finished brass door latch with necessary screwsetc. complete :300x16x5 aun DSR 9.75.1
10Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (copper oxidized as per IS: 1378) 300x16 mm DSR 9.62.1
11Providing and fixing bright finished brass handles with screws etc.complete: 125 mm DSR 9.81.1
12Providing and fixing bright finished brass hanging type floor door stopper withnecessary screws, etc. complete DSR 9.82
13Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications. Painting wood work with Deluxe Multi 13 Surface Paint of required shade. Two or more coat applied @ 0.90 1tr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture DSR-13.48.2
14Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm. DSR11.41.2
15providing and fixing 43\\" inch led tv
16Providing and fixing M.S Board
17Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc as per site requirement and as directed by Engineer in-charge.
18Wiring for circuit / submain wiring along with earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as per site requirement and as directed by Engineer in-charge.
19Wiring for circuit / submain wiring along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as per site requirement and as directed by Engineer in-charge.
20Supplying and fixing 5/6 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc as per site requirement and as directed by Engineer in-charge.
21Supplying and fixing 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc as per site requirement and as directed by Engineer in-charge.
22Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as per site requirement and as directed by Engineer in-charge.
23Supplying and fixing suitable size GI box with plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc as per site requirement and as directed by Engineer in-charge.
24Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc as per site requirement and as directed by Engineer in-charge.
25Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc as per site requirement and as directed by Engineer in-charge.
26Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non-residential buildings) as per site requirement and as directed by Engineer in-charge.
27Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc as per site requirement and as directed by Engineer in-charge.
28Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
29Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc.as per site requirement and as directed by Engineer in-charge.
30Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & springwasher spaced at 50mm) as per site requirement and as directed by Engineer in-charge.
31Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. Complete as per site requirement and as directed by Engineer in-charge.
32LED Batten light 18-22 Watt (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen (Thickness > 1.20 mm)
33Brush Less Direct Current (BLDC) Fan without Remote 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding,
34Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm direct in ground including excavation and refilling the trench etc as required, but excluding and cushioning and protective covering.as per site requirement and as directed by Engineer in-charge.
35Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade Upto 35 sq. mm size in the existing masonry open duct as per site requirement and as directed by Engineer in-charge.
36Supplying and making end termination with brass compression gland and aluminium lugs for 2 X 6 sq. mm (19mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as per site requirement and as directed by Engineer in-charge.
37Supply & fix one 3 pin socket outlet 5 Amp on same board wiring with PVC insulated copper wire 1.5 Sqmm with continues earth wire. as per site requirement or directed by EIC.
38Supply and making of maintenance free chemical earthing as per IS-3043 with arrangement for earthing of 50 mm Dia 3 Mtr. lenth pure copper electrode backfill compound (BFC BAG). It also includes supply & making chamber with cement concrete ratio 1:3:6 (20 mm graded agregate) for making earth pit with painting of Yellow colour, CI hinged cover plate/pre cast reinforement cover with lifting handle to be fixed on top of the pit along with display plate of earthing value complete in all respect. as per site requirement and as directed by Engineer in-charge.
39Supply of 1.1 KV grade of 6 sq.mm X 2 core power cable complete testing and commissioning XLPE insulated Aluminium conductor armoured underground LT cable. As per site requirement or directed by Engineer in-charge.Make: Gloster/ Havells/ KEI/ Finolex
40Less 5% Departmental Charges Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56763522
AUTHORITY Government Departments
TENDER VALUE 2.62 Lakhs
LAST DATE 13-08-2026
Authority
Authority Name Uttar Pradesh Small Industries Corporation Limited
Work Description Tender for Installation Work Of Astronomy Laboratory At Higher Primary School In Urwa, Vikash Khand-Kidwai Nagar Under Basic Education Under Ssc Scheme Kanpur Nagar.
Basic Detail
Tender No 712/EE2/UPSIC/2026-27
Bidding Type Tender
Location
City Kanpur Nagar
State Uttar Pradesh
Key Dates
Publish Date 31 Jul 2026
Submission Date 13 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 2.62 Lakhs
Tender Fee 590
EMD 2700
Exemption Not Available
Document List
BOQ_2204734.xls
dae0736b-8a98-4263-93e8-7831ffdf3a72.html
Tendernotice_1.pdf
TermsandConditionTenderCivilWorks.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2204734.xls

html

dae0736b-8a98-4263-93e8-7831ffdf3a72.html

pdf

Tendernotice_1.pdf

pdf

TermsandConditionTenderCivilWorks.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders