Tender For Repair & Painting Of Rooms & Toilet Of Honble Minister Chamber At 1St Floor & 5Th Floor Including Replacement Of Curtains Of Joint Administrative Building, Department Of Planning & Statistics, During The Year 2026-2027.
Tender Overview
Project Description
Tender for Repair & Painting Of Rooms & Toilet Of Honble Minister Chamber At 1St Floor & 5Th Floor Including Replacement Of Curtains Of Joint Administrative Building, Department Of Planning & Statistics, During The Year 2026-2027.
BOQ
| Sl. No. | Item Description |
| 1 | (b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) |
| 2 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat. (ii) Solvent based interior grade Acrylic Primer. |
| 3 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)(ii) Luxury Quality. |
| 4 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. a) False Ceiling (with 4mm thick Pearl Designer Fibre Cement Board and E-Grid T-2430/1510). |
| 5 | Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge. |
| 6 | Supplying, fitting and fixing shower of approved brand and make. (f) Hand shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 7 | Supplying, fitting and fixing bib cock or stop cock. (d) (ii) Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand). |
| 8 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size. |
| 9 | Supplying, fitting and fixing pedestal of approved make for wash basin (white). |
| 10 | Supplying, fitting and fixing pillar cock of approved make. e) (ii) CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand). |
| 11 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm. |
| 12 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work. PVC Pipes (Dia) 50 mm. |
| 13 | Supply, fitting & fixing curtain of best quality approved fabric (Maruti-CH101462 304) in position and necessary Heavy Quality Plastic Curtain Ring, Stainless Steel Window/Door CuratinRods/Pipes (25mm dia), Stainless Steel Curtain Bracket for changing complete as per direction of Engineer-in-Charge. |
| 14 | Supplying, fitting and fixing VGS-WHT-0312 decorative Couple Closet WC with Cistern (Jaguar make couple closet W.C. size 810X405X730 mm) The Rate including the cost of all materials, labour charges for scaffolding etc. complete in all respect as per direction of Engineer-in-Charge. |
| 15 | Supply, fitting & fixing textile fabric window covering as approved fixed in 40mm dia powder coated aluminium roller bar supported in 50mm dia OVC pully along with |
| 16 | Supply, fitting & fixing of Stainless Steel Plaet 1.2 mm thick with sank type (engraved) letters as to fixed at the wall as design and choice of department, the part is inclusive of charges for fabrication, cost of materials, polishing etc. and the incidental charges and all taxes if any. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender