Tender For Bid No. Dm/Ms/Cpm-Mp/303: Construction Of Police Station & Barrack For Upssf At Modipuram Depot, Police Posts And Assistance Booths At Brahmapuri, Meerut Central, Bhaisali, Begumpul, Mes Colony, Daurli, Meerut North And Modipuram Namo Bhar
Tender Overview
Project Description
Tender for Bid No. Dm/Ms/Cpm-Mp/303: Construction Of Police Station & Barrack For Upssf At Modipuram Depot, Police Posts And Assistance Booths At Brahmapuri, Meerut Central, Bhaisali, Begumpul, Mes Colony, Daurli, Meerut North And Modipuram Namo Bharat Stations At Meerut Of Delhi-Ghaziabad-Meerut Namo Bharat Corridor Including Architectural, E&M, Plumbing, Etc. And Other Miscellaneous Works Incl. Road Works.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2026 | Addendum - 1 | Date | 14-Sep-2026 |
| 2 | 21-Aug-2026 | Addendum - 1 | Other | 14-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NATIONAL CAPITAL REGION TRANSPORT CORPORATION LTD. Bid No. DM/MS/CPM-MP/303: Construction of Police Station & Barrack for UPSSF at Modipuram Depot, Police Posts and Assistance Booths at Brahmapuri, Meerut Central, Bhaisali, Begumpul, MES Colony, Daurli, Meerut North and Modipuram Namo Bharat Stations at Meerut of Delhi-Ghaziabad-Meerut Namo Bharat Corridor including Architectural, E&M, Plumbing, etc. and other miscellaneous works incl. road works. Price Bid NATIONAL CAPITAL REGION TRANSPORT CORPORATION LTD Gatishakti Bhawan INA, New Delhi –110 023 Preamble Name of Work: Bid No. DM/MS/CPM-MP/303: Construction of Police Station & Barrack for UPSSF at Modipuram Depot, Police Posts and Assistance Booths at Brahmapuri, Meerut Central, Bhaisali, Begumpul, MES Colony, Daurli, Meerut North and Modipuram Namo Bharat Stations at Meerut of Delhi-Ghaziabad-Meerut Namo Bharat Corridor including Architectural, E&M, Plumbing, etc. and other miscellaneous works incl. road works. S.No. Description |
| 2 | The Price bid shall be read in conjunction with the Bidding Documents. |
| 3 | There are 4 Schedules in the Financial Bid as follows : (i) Schedule - A (DSR Civil Items)(ii) Schedule - B (NDSR-Civil Items)(iii) Schedule - C (DSR ELectrical)(iv) Schedule - D (NDSR Electrical)The bidder is required to quote a flat percentage \\"Excess\\" (+) / \\"Less\\" (-) / \\"At par\\" with respect to the Total amount of all the Schedules in the \\"BoQ1\\" Sheet and further discount if any may be Quoted in the \\"BOQ2\\" Sheet along with methodology of discount if any. The percentage quoted by the Bidder in \\"BoQ1\\" sheet and discount (if any) quoted by the Bidder in the \\"BoQ2\\" will be applied on the individual rate for all schedules for the purpose of payment to the Contractor. |
| 4 | The quantities for various items provided in the Price Bid are estimated quantities and are given to provide a common basis for Bidding. During the execution of works, the same may vary based upon \\"Good for Construction\\" (GFC) drawings approved by the Engineer and as per the site conditions. The basis of the payment will be the actual quantities of the work executed and accepted by the Engineer or quantities as per the GFC drawings whichever is less and shall be paid / valued as per the accepted rates. |
| 5 | The quoted rates for various items are for completed and finished items of work complete in all respects. It will be deemed to include all the cost involved in the execution of the items and shall include all duties, taxes [except Goods and Service Tax (GST) and Custom Duty] royalties, cess, overheads, profit and other levies payable by the Bidder under the Contract, or for any other cause etc. The Bidder shall be required to consider this aspect while quoting rates. It shall include all general risks, liabilities and obligations set out or implied in the Contract shall and including remedy of any defects during the Defect Liability Period, unless otherwise provided in the Contract. The whole cost of complying with the provisions of the Contract shall be deemed to have been included in the quoted rates. GST as prevalent will be paid extra. |
| 6 | Bidder may please note that to perform this contract nothing extra shall be payable on account of field constraints, non-availability of uninterrupted front, cost of project management, monitoring, coordination and supervision, cost of adhering to quality requirements (QA/QC), cost of adhering to SHE requirements, cost of preparing drawings and documents, as-built records and documentation, preparation of detailed scheme for taking necessary clearance and approval from the concerned authority and other local bodies etc. |
| 7 | Income Tax and any other statutory taxes to be deducted at source will be deducted by the Employer from the due payments of the contractor in accordance with the prevailing rules in force. |
| 8 | Bidder should not tamper the Price Bid. If the Price Bid is found to be modified by the bidder, then the same will be treated as incomplete and non-responsive and may result in the rejection of the Bid. |
| 9 | Method of Quoting the Price in the Price Bid:The Price Bid is in Excel Format and the Quoting the Price in the Price Bid should be as Follows: (i) Whole Excel Worksheet is Locked except the Cells which are highlighted in Blue. (ii) Bidders are required to fill these cells which are highlighted in Blue only. (iii) Bidder is required to quote a flat percentage Excess/Less/At par on 'Total Amount of all the Schedules' in \\"BOQ1'' Sheet of Price Bid and further discount if any in BOQ2 of Price Bid along with methodolodgy of discount if any. (iv) All 'blanks' in the Pricing Document, where the Bidder is permitted to quote shall be filled in. (v) If some % is quoted inspite of marking 'At par' that % will not be considered and it will be taken as \\"At par\\" on basic amount. Failure to quote the % in case of excess or less for the \\"Total amount of Schedule\\" shall be treated as \\"At Par\\" and shall be evaluated accordingly. (vi) Bidder is required to quote Rates in INR only. |
| 10 | Errors will be corrected by the Employer for any arithmetic errors in computation or summation as per contract conditions. |
| 11 | For Calculation of rates (excluding GST) of DSR 2023 items, following Methodology issued by CPWD vide Office Memorendum (OM) dated 08.08.2024 have been adopted:As per CPWD OM the rates of individual items of DSR 2023 has been multiplied with correction factor on account of GST @ 0.973 to the existing rate of DSR 2023 item in order to achieve modified DSR rate and then reduced the corrected rate by 18% for making DSR item excluding GST.Note:The above Methodology shall be applicable for calculating the rate of Individual Items of DSR 2023 in Schedule B (to be executed under Lump Sum amount).Based on the above Methodology and price quoted by the bidder payment shall be made for the individual items executed under Lump Sum amount of DSR 2023 in Schedule B. NOTE: The work may have to be done during the block periods (during non-operational hours) as per direction of the Engineer-in-charge. |
| 12 | SCHEDULE-A |
| 13 | SCHEDULE-B |
| 14 | SCHEDULE-C |
| 15 | SCHEDULE-D |
| 16 | Total Amount of Schedules. |
| 17 | Total amount of schedule Letter of Price Bid Bid No.: DM/MS/CPM-MP/303 To National Capital Region Transport Corportation Limited GatiShakti Bhawan,INA, New Delhi- 110023 We, the undersigned, declare that: (a) We have examined and have no reservations to the Bidding Documents, including Addenda issued in accordance with Instructions to Bidders (ITB) 8. (b) We offer to execute in conformity with the Bidding Documents and the Technical Bid submitted for the following Works: Name of Work: Bid No. DM/MS/CPM-MP/303: Construction of Police Station & Barrack for UPSSF at Modipuram Depot, Police Posts and Assistance Booths at Brahmapuri, Meerut Central, Bhaisali, Begumpul, MES Colony, Daurli, Meerut North and Modipuram Namo Bharat Stations at Meerut of Delhi-Ghaziabad-Meerut Namo Bharat Corridor including Architectural, E&M, Plumbing, etc. and other miscellaneous works incl. road works. (c) The total price of our Bid, excluding any discounts offered in item (d) below is: [amount in INR in figures] 0.0 DISCOUNT (IN %age ) Discount methodology (d) The discounts offered and the methodology for their application indicated in BoQ2 sheet are:- 0.0 0.0 Discount Amount 0.0 (e) The total price of our Bid, including discounts offered in item (d) above is: [Amount in INR in figures] 0.0 [Amount in INR in words] INR Zero Only (f) (g) If our Bid is accepted, we commit to obtain a performance security in accordance with the Bidding Documents. (h) We understand that this bid, together with your written acceptance thereof included in your notification of award, shall constitute a binding contract between us, until a formal contract is prepared and executed. (i) We understand that you are not bound to accept the lowest evaluated bid or any other bid that you may receive. Name of the authorized representative of the bidder Desiganation of the authorized representative Name of the Bidder/ Bidding Firm / Company : 0.0 Date: (DD/MM/YYYY) SCH A DSR 2023 Item no. UOM Police Oupost 8 no. Police Post SVPUAT Road NHAI Service Road Police Barrack Qty. ESS Pump Room Total Quantity Rate (DSR 2023) DSR 2023 Rates after multiplying with GST factor of 0.973 Amount Rate After Multiplying with GST factor of 0.973 and excluding GST Amount excluding GST KSMB Rate (Based on DSR 2018)(INR) KSMB Rate Excluding GST after discount of 5.89% KSMB Rate Excluding GST after Discount AND Escalation of 8.0% CP Associates DSR 2021 Rate (In INR) including GST CP Associates DSR Rate Excluding GST (In INR) CP Associates DSR Rate Excluding GST and after discount of 10.50% (In INR) CP Associates DSR Rates Excluding GST and after Discount and Escalation of 6% G&G INFRATECH PVT. LTD. Excluding GST G&G INFRATECH PVT. LTD. Excluding GST and after discount of 35.1 METCON - CP (JV) Excluding GST METCON - CP (JV) Excluding GST and after Discount METCON - CP (JV) Excluding GST and after Discount and Escalation of 13.66% Lowest Rate Excluding GST and after discount and Escalation Amount Remarks ESS amount SVPUAT Amount Police oupose amount Amount DSR 2023 |
| 18 | 1.1.2 |
| 19 | 2.3.1 |
| 20 | 2.6.1 |
| 21 | 2.8.1 |
| 22 | 2.1 2.10.1 All kinds of soil. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 23 | 2.10.1.1 |
| 24 | 2.10.1.2 |
| 25 | 2.10.1.3 |
| 26 | 2.25 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 27 | 2.26.1 |
| 28 | 2.31 Total of Earth Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 29 | 4.3 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 30 | 4.3.1 |
| 31 | 4.11 4.2 Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully authomatic batching plant and transported to site of work in transit mixer for all leads, having continous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing,including cost of curing, admixtures in recommended proportions as per IS 9103 to accelerate / retard setting of concrete, improve workability without imparting strength and durability as per direction of the Engineer-in-charge.Note : 1) Excess / less cement used than specified in this item is payable / recoverable separately. 0.0 0.0 0.0 0.0 0.0 0.0 4.20.1 All works upto plinth level : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 32 | 4.20.1.2 Total of Concrete Works 0.0 0.0 0.0 0.0 0.0 0.0 |
| 33 | 5.9 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 34 | 5.9.1 |
| 35 | 5.9.2 |
| 36 | 5.9.3 |
| 37 | 5.9.5 |
| 38 | 5.9.6 |
| 39 | 5.9.7 |
| 40 | 5.9.16.1 5.11 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) 0.0 0.0 0.0 0.0 0.0 0.0 |
| 41 | 5.11.1 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 42 | 5.22.6 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 43 | 5.22.A.6 0.0 0.0 0.0 0.0 0.0 0.0 5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolona/ordinary portland/Portland slag cement, admixtures in recommended proportions as per IS9103 to accelerate /retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing , carriage for all leads; but excluding the cost of centring, shuttering , finishing and reinforcement as per the direction of the enginee-in-charge, for the following grades of concrete :Note : Extra cement upto 10% of the minimum specified cement content in design Mix shall be paid seperately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 0.0 0.0 0.0 0.0 0.0 0.0 5.33.1 All works upto plinth level 0.0 0.0 0.0 0.0 0.0 0.0 |
| 44 | 5.33.1.1 |
| 45 | 5.33.1.2 |
| 46 | 5.33.1.4 5.33.2 All works above plinth level upto floor V level 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 47 | 5.33.2.1 |
| 48 | 5.33.2.2 |
| 49 | 5.33.2.4 |
| 50 | 5.35 5.43 Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 51 | 5.43.1 5.44 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). 0.0 0.0 0.0 0.0 0.0 0.0 |
| 52 | 5.44.1 5.45 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge.The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 0.0 0.0 0.0 0.0 0.0 0.0 |
| 53 | 5.45.1 5.46 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement.(Material shall confirm to ASTM 6063.) 0.0 0.0 0.0 0.0 0.0 0.0 |
| 54 | 5.46.1 Total of Reinforced Cement Concrete Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 55 | 6.1 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 0.0 0.0 0.0 0.0 0.0 0.0 |
| 56 | 6.1.2 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in 0.0 0.0 0.0 0.0 0.0 |
| 57 | 6.4.2 6.34 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : 0.0 0.0 0.0 0.0 0.0 |
| 58 | 6.34.2 Total of Brick Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 59 | 7.32 7.32 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 Cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 60 | 7.32.1 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 0.0 0.0 0.0 0.0 0.0 0.0 8.2.2 Granite of any colour and shade 0.0 0.0 0.0 0.0 0.0 0.0 |
| 61 | 8.2.2.2 8.3 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 62 | 8.3.2 |
| 63 | 8.5 8.1 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregates) as per direction of Engineer-in-charge and finished smooth. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 64 | 8.10.2 |
| 65 | 8.2 8.2 Providing and fixing dry cladding upto 10 metre heights with 30 mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge.(The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 0.0 0.0 0.0 0.0 0.0 0.0 |
| 66 | 8.20.1 |
| 67 | 9.97 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 68 | 9.97.1 |
| 69 | 9.97.2 |
| 70 | 9.97.3 |
| 71 | 9.97.4 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 72 | 9.100.1 9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 73 | 9.101.2 Total of STONE Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 74 | 10.25 10.25 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 75 | 10.25.2 10.26 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircases railing and similar works, including applying priming coat of approved steel primer. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 76 | 10.26.1 10.27 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete / masonry, etc. as per direction of Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 77 | 10.27.1 |
| 78 | 10.27.2 |
| 79 | 10.28 Total Steel Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 80 | 11.37 11.49 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622 , of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 0.0 0.0 0.0 0.0 0.0 0.0 |
| 81 | 11.49.2 Total of Flooring Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 82 | 12.21 12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 83 | 12.21.1 |
| 84 | 12.22 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 85 | 12.41.2 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 0.0 0.0 0.0 0.0 0.0 0.0 12.42.4 Singel tee without door 0.0 0.0 0.0 0.0 0.0 0.0 |
| 86 | 12.42.4.2 12.42.6 Shoe (Plain) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 87 | 12.42.6.2 12.43 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 88 | 12.43.2 12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 m dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45x15x0.9mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in direction perpendicular to G.I intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gymsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 ,mm at 230 mm c/c including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specifications and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings, specification and direction of the Engineer-in-charge but excluding the cost of painting with: 0.0 0.0 0.0 0.0 0.0 0.0 |
| 89 | 12.45.1 |
| 90 | 12.46 12.54 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring 'T' with : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 91 | 12.54.2 |
| 92 | 12.63 Total of Roofing Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 93 | 13.4 13.4 12 mm cement plaster of mix : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 94 | 13.4.1 |
| 95 | 13.11 13.16 6 mm cement plaster of mix : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 96 | 13.16.1 |
| 97 | 13.26 13.4 12 mm cement plaster of mix 0.0 0.0 0.0 0.0 0.0 0.0 13.41 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 98 | 13.41.1 13.44 Finishing walls with waterproofing cement paint of required shade: 0.0 0.0 0.0 0.0 0.0 0.0 |
| 99 | 13.44.1 13.45 Finishing walls with textured exterior paint of required shade : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 100 | 13.45.1 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 101 | 13.46.1 13.52 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 102 | 13.52.1 |
| 103 | 13.52.2 |
| 104 | 13.8 13.82 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, toachieve even shade and colour. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 105 | 13.82.2 Total of Finishing Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 106 | 15.3 15.7 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceabl 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 107 | 15.7.4 |
| 108 | Deleted |
| 109 | 16.1 16.31 Providing and applying track coat using bitumen emulsion conforming to IS : 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. 0.0 0.0 0.0 0.0 0.0 0.0 16.31.2 With medium setting bitumen emulsion 0.0 0.0 0.0 0.0 0.0 0.0 |
| 110 | 16.31.2.1 |
| 111 | 16.31.2.2 |
| 112 | 16.45 16.46 Providing and laying in position bitumen hot sealing compound for expansion joints etc. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 113 | 16.46.1 |
| 114 | 16.53 16.54 Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 0.0 9. 16.54.1 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. cum 40.0 135.0 1265.0 11129.55 10829.05 14078880.75 9177.16 11609107.4 10064.25 8456.67 9133.2 0.0 0.0 9133.2 11553498.0 445182.0 1502489.25 |
| 115 | 16.57 |
| 116 | 16.57.1 |
| 117 | 16.68 |
| 118 | 16.69 16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 119 | 16.78.1 |
| 120 | 16.79 |
| 121 | 16.81 |
| 122 | 16.93 17.1 Providing and fixing water closet squatting pan (Indian type WC pan ) with 100 mm sand cast iron P or S trap, 10 lit low level white PVC flushing cistern, including flush pipe with manually controlled device (hand lever) confirming to IS:7231, with all fittings and fixture complete including cutting and making good the walls and floors where ever required: (Fixture to be taken as IGBC approved or approved by Engineer Incharge/Architect Incharge) 0.0 0.0 0.0 0.0 0.0 0.0 |
| 123 | 17.1.1 17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all filings and fixtures complete, including cutting and making good the walls and floors wherever required: each 0.0 0.0 0.0 0.0 0.0 |
| 124 | 17.2.1 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillartaps, 32 mm C.P. brass waste of standard pattern, including painting offittings and brackets, cutting and making good the walls wherever require: 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 125 | 17.7.1 |
| 126 | 17.7.4 |
| 127 | 17.10.1.1 |
| 128 | 17.10.2.1 |
| 129 | 17.22A |
| 130 | 17.28.2.1 17.32 Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved make andshade with 6 mm thick hard board backing : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 131 | 17.32.4 17.34 Providing and fixing toilet paper holder : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 132 | 17.34.1 |
| 133 | 17.35.1.2 17.6 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 0.0 0.0 0.0 0.0 0.0 0.0 17.60.1 100 mm inlet and 100 mm outlet 0.0 0.0 0.0 0.0 0.0 0.0 |
| 134 | 17.60.1.1 17.65 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste SFRP vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 135 | 17.65.1 |
| 136 | 17.65.2 17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 137 | 17.69.2 |
| 138 | 17.72 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 0.0 0.0 0.0 0.0 0.0 0.0 LS 0.0 |
| 139 | 17.73.2 |
| 140 | 17.80 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 0.0 0.0 0.0 0.0 0.0 0.0 Internal work - Exposed on wall 0.0 0.0 0.0 0.0 0.0 0.0 |
| 141 | 18.7.1 |
| 142 | 18.7.2 |
| 143 | 18.7.3 |
| 144 | 18.7.4 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall Metre 0.0 0.0 0.0 0.0 0.0 0.0 0.0 23 23 0.0 23 |
| 145 | 18.7.5 |
| 146 | 18.7.6 0.0 0.0 0.0 0.0 0.0 0.0 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and The cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 147 | 18.8.1 |
| 148 | 18.8.2 |
| 149 | 18.8.3 |
| 150 | 18.8.4 |
| 151 | 18.9 External work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 152 | 18.9.1 |
| 153 | 18.9.2 |
| 154 | 18.9.3 |
| 155 | 18.9.4 |
| 156 | 18.9.5 |
| 157 | 18.9.5 18.9.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge .External work Metre 0.0 0.0 0.0 0.0 0.0 0.0 0.0 217461.0 23 0.0 0.0 |
| 158 | 18.9.6 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge .External work Metre 0.0 0.0 0.0 0.0 0.0 0.0 0.0 422385.0 23 0.0 0.0 |
| 159 | 18.9.7 18.9.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work Metre 0.0 0.0 0.0 0.0 0.0 0.0 0.0 355428.0 23 0.0 0.0 |
| 160 | 18.9.8 |
| 161 | 18.9.9 |
| 162 | Based on DSR It 18.13.2 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 163 | 18.17.1A |
| 164 | 18.17.1 |
| 165 | 18.17.2 |
| 166 | 18.17.3 |
| 167 | 18.17.4 |
| 168 | 18.17.5 |
| 169 | 18.17.6 18.18 Providing and fixing balll vave (brass) of approved quality, High or low pressure, with plastic floats complete. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 170 | 18.18.1 |
| 171 | 18.18.2 |
| 172 | 18.18.3 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 0.0 0.0 0.0 0.0 0.0 0.0 18.19.4 50 mm nominal bore 0.0 0.0 0.0 0.0 0.0 0.0 |
| 173 | 18.19.4.1 18.19.5 65 mm nominal bore 0.0 0.0 0.0 0.0 0.0 0.0 |
| 174 | 18.19.5.1 18.19.6 80 mm nominal bore 0.0 0.0 0.0 0.0 0.0 0.0 |
| 175 | 18.19.6.1 18.2 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 176 | 18.20.1 |
| 177 | 18.20.2 |
| 178 | 18.20.3 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions : 0.0 0.0 0.0 0.0 0.0 0.0 18.21.1 30 cm length 0.0 0.0 0.0 0.0 0.0 0.0 |
| 179 | 18.21.1.1 |
| 180 | 18.21.2.2 18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 181 | 18.22.2 18.27 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 182 | 18.27.1 |
| 183 | 18.27.3 18.31 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 0.0 0.0 0.0 0.0 0.0 0.0 18.31.1 100 mm diameter 0.0 0.0 0.0 0.0 0.0 0.0 |
| 184 | 18.31.1.2 18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 185 | 18.33.1 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 186 | 18.34.1 18.37 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 187 | 18.37.1 |
| 188 | 18.48 18.49 Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 189 | 18.49.1 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 190 | 18.51.1 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 191 | 18.52.1 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 0.0 0.0 0.0 0.0 0.0 0.0 |
| 192 | 18.53.1 18.58 Providing and fixing PTMT grating of approved quality and colour. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 193 | 18.58.1.1 18.58.2 Rectangular type with openable circular lid 0.0 0.0 0.0 0.0 0.0 0.0 |
| 194 | 18.58.2.1 18.6 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 195 | 18.60.1 18.61 Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 196 | 18.61.2 |
| 197 | 18.65 Total of Water Supply 0.0 0.0 0.0 0.0 0.0 0.0 |
| 198 | 19.1 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 199 | 19.1.1 |
| 200 | 19.1.2 |
| 201 | 19.1.3 |
| 202 | 19.1.4 |
| 203 | 19.1.5 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 0.0 0.0 0.0 0.0 0.0 0.0 |
| 204 | 19.2.1 |
| 205 | 19.2.2 |
| 206 | 19.2.3 |
| 207 | 19.2.4 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 208 | 19.3.5 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 19.4.1 100 x 100 mm size P type 0.0 0.0 0.0 0.0 0.0 0.0 |
| 209 | 19.4.1.1 19.4.2 150 x 100 mm size P type 0.0 0.0 0.0 0.0 0.0 0.0 |
| 210 | 19.4.2.1 19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight offrame 15 kg) : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 211 | 19.7.1.1 19.7.2 Inside size 120 x 90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) 0.0 0.0 0.0 0.0 0.0 0.0 |
| 212 | 19.7.2.1 19.9 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 213 | 19.9.1.1 19.11 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 214 | 19.11.1.1 19.13 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 19.13.1 2.30m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 215 | 19.13.1.1 |
| 216 | 19.16 19.18 Supplying and fixing CI cover with frames for manholes : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 217 | 19.18.2 |
| 218 | 19.18.3 19.21 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 219 | 19.21.2 |
| 220 | 19.21.3 19.27 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 221 | 19.27.1 19.28 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 222 | 19.28.1 19.35 Providing and laying non-pressure NP3 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 223 | 19.35.1 19.36 Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 0.0 0.0 0.0 0.0 0.0 0.0 |
| 224 | 19.36.1 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred & jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling C.P. brass/stainless steel screws all complete as per Architectural drawings and the directions of Engineer-in-charge (Glazing, paneling and dash fasteners to be paid for separately) : 0.0 0.0 0.0 0.0 0.0 0.0 21.1.1 For fixed portion 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 225 | 21.1.1.2 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 0.0 0.0 0.0 0.0 0.0 0.0 |
| 226 | 21.1.2.2 21.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 227 | 21.2.1 |
| 228 | 21.2.2 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): 0.0 0.0 0.0 0.0 0.0 0.0 |
| 229 | 21.3.2 21.4 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 230 | 21.4.1 21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approvedquality as per architectural drawings and direction of Engineer-in-charge complete. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 231 | 21.8.1 |
| 232 | 21.18 21.19 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 0.0 0.0 0.0 0.0 0.0 0.0 |
| 233 | 21.19.1 22.1 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 234 | 22.1.1 22.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 235 | 22.2.1 DSR-2018 (22.4) Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : 0.0 0.0 0.0 0.0 0.0 0.0 |
| 236 | 22.4.1 |
| 237 | 22.5 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 238 | 22.7.1 22.23 Providing and applying integral crystalline slurry of hydrophilic in naturefor waterproofing treatment to the RCC structures like retaining walls ofthe basement, water tanks, roof slabs, podiums, reservior, sewage &water treatment plant, tunnels / subway and bridge deck etc., preparedby mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 partswater) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1part water) for horizontal surfaces and applying the same from negative(internal) side with the help of synthetic fiber brush. The material shallmeet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with controlconcrete as per DIN 1048 and resistant to 16 bar hydrostatic pressureon negative side. The crystalline slurry shall be capable of self-healingof cracks up to a width of 0.50 mm. The work shall be carried out allcomplete as per specification and the direction of the engineer-in-charge.The product performance shall carry guarantee for 10 years against anyleakage. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 239 | 22.23.1 |
| 240 | 22.23.2 |
| 241 | 22.26 Total of Road Work 0.0 0.0 0.0 0.0 0.0 0.0 Total of Aluminium Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 242 | Total of Water Proofing Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 243 | Hort DSR 2023 Item No. |
| 244 | Total of Horticulture & Landscaping Work 0.0 0.0 0.0 0.0 0.0 0.0 |
| 245 | 23.1 23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. 0.0 0.0 0.0 0.0 0.0 0.0 23.1.1 All types of soil 0.0 0.0 0.0 0.0 0.0 0.0 |
| 246 | 23.1.1.1 23.3 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 247 | 23.3.3 23.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 248 | 23.4.3 |
| 249 | 23.8 23.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 0.0 0.0 0.0 0.0 0.0 0.0 |
| 250 | 23.13.3 23.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 251 | 23.14.3 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 0.0 0.0 0.0 0.0 0.0 0.0 |
| 252 | 23.15.3 Total of Rain Water Harvesting & Tubewells 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 |
| 253 | 25.2 (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. 0.0 0.0 0.0 0.0 0.0 0.0 |
| 254 | 25.6 0.0 0.0 0.0 0.0 0.0 TOTAL FOR SCHEDULE A (including GST) - DSR ITEMS 0.0 0.0 0.0 0.0 0.0 0.0 |
| 255 | 274372985.86 TOTAL 226240903.56 173167227.25 11542517.74 6110991.47 1715125.96 266964266.2008 274372318.808633 667.05 SCH B S. NO. Item no. Description UOM Police Out post Total qty. Rate including GST Rate excluding GST (INR) Amount (INR) 1.0 METAL WORK |
| 256 | 1.1 2 FLOORING WORK 0.649 2.1 Access raised floor |
| 257 | 2.2.1 |
| 258 | 2.3 3.5.1 Extra for Jet Black, Icone Brown, Lakha red or Red Silk, BluePearl granite SQM 365.16 0.0 |
| 259 | 2.4.1 3.8 Counters of MS carcass in TOM, EFO etc Sqm 4108.12 0.0 3.9 Foam Concrete flooring cum 5115.28 0.0 3.10 VDF Flooring Sqm 300.13 0.0 3.11 Cutting of grooves on concrete /surface Rmt 77.24 0.0 3.12 5 mm thick and 30mm deep SS strips at material joint locationfor VDC flooring kg 429.13 0.0 |
| 260 | 2.5 Total of Flooring Work 3 FIRE DOORS |
| 261 | 3.16 Total of Fire Doors 4 MISCELLANEOUS WORK |
| 262 | 4.4.1 |
| 263 | 4.4.2 |
| 264 | 4.4.3 |
| 265 | 4.4.4 |
| 266 | 4.4.5 |
| 267 | 4.4.6 |
| 268 | 4.13 Total of Miscellaneous Work 5 FINISHING WORK |
| 269 | 5.1 Total of Finishing Work 6 SANITARY FIXTURES |
| 270 | 6.5.1 |
| 271 | 6.6 Total of Sanitary Fixtures 7 SOIL, WASTE AND RAIN WATER PIPES 7.1 Spun cast iron pipe for soil, waste and vent including allnecessary fittings and supports |
| 272 | 7.1.1 |
| 273 | 7.1.2 |
| 274 | 7.1.3 |
| 275 | 7.1.4 7.2 Same as above item no. but pipes are running below ground in trenches (for internal areas upto manhole) upto required depth including excavation in all kind of soil including hard rock, refilling, watering, ramming, removing & disposal of the surplus excavated material as per instructions by siteincharge and making good the same. |
| 276 | 7.2.1 |
| 277 | 7.2.2 7.3 1:2:4 cement conc. 100 mm thick all round the pipe |
| 278 | 7.3.1 |
| 279 | 7.3.2 7.4 G.I. pipe and fittings with supports |
| 280 | 7.4.1 |
| 281 | 7.4.2 |
| 282 | 7.4.3 7.5 Puddle flange |
| 283 | 7.5.1 7.6 Clean out plug |
| 284 | 7.6.1 |
| 285 | 7.6.2 7.7 SS grating with frame |
| 286 | 7.7.1 |
| 287 | 7.9 7.10 UV stabilized SWR (Type - B) Rain Water pipes |
| 288 | 7.10.1 |
| 289 | 7.10.2 |
| 290 | 7.10.3 |
| 291 | 7.11 7.12 600mm long puddle flanges |
| 292 | 7.12.1 |
| 293 | 7.12.2 |
| 294 | 7.12.3 |
| 295 | 7.12.4 |
| 296 | 7.12.5 |
| 297 | 7.12.6 |
| 298 | 7.12.7 |
| 299 | 7.12.8 7.13 HDPE pipe NP4 |
| 300 | 7.13.1 |
| 301 | 7.13.2 |
| 302 | 7.13.3 7.14 Non-pressure NP3 class R.C.C. pipes with collars jointed |
| 303 | 7.14.1 |
| 304 | 7.14.2 7.15 Non-pressure NP4 class R.C.C. pipes with collars jointed - |
| 305 | 7.15.1 |
| 306 | 7.15.2 |
| 307 | 7.15.3 Total of Soil, Waste and Rain Water Pipes 8.2 Suction And Delivery Pipes And Valves For Water SupplyPumps 8.2.1 G.I. suction & delivery headers / pipes for water supply pumps |
| 308 | 8.2.1.1 |
| 309 | 8.2.1.2 |
| 310 | 8.2.1.3 |
| 311 | 8.2.1.4 8.3 Gun metal ball valve with SS ball. |
| 312 | 8.3.1 |
| 313 | 8.3.2 8.4 C.I. wafer type Butterfly valves |
| 314 | 8.4.1 |
| 315 | 8.4.2 |
| 316 | 8.4.3 |
| 317 | 8.4.3 8.5 C.I. Double flanged horizontal type non-return valve |
| 318 | 8.5.1 8.6 suction strainer with M.S. flanged connection |
| 319 | 8.6.1 Total of Water Supply 9 SEWERAGE AND DRAINAGE 9.1 NP3 class R.C.C. pipes with collars jointed |
| 320 | 9.1.1 Total of Sewerage and Drainage 11 WATER TREATMENT PLANT Note: The firm will include in its rates for maintenance and operation of system including all consumable except electrically for 18 months after date of completion ofworks without any extra cost. 11.1 Providing and fixing skid mounted vertical MSRL Dual Media pressure filter fabricated from IS 226/2062 plate 5mm thick for shell and 6mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, painting, testing and commissioning complete (for domestic water supply system). Capacity 9000 lph. Flow through rate 10000 lph/m2 Working pressure 2.5 kg./cm2 |
| 321 | 11.1.1 |
| 322 | 11.2 11.3 Providing and fixing bulk water meter with direct reading dial in KL, all internal parts and strainer in gun metal/brass. |
| 323 | (a) 11.4 Providing and fixing direct reading rate of flow Rota Meter |
| 324 | 11.5 11.6 Supply, assembly, erection, testing and commissioning of UV treatment unit for water supply filter (Alfaa make or approved make). |
| 325 | (a) Total of Water Treatment Plant |
| 326 | 12.0 Total of Sewerage TreatmentPlant 13 PLUMBING WORKS FOR OVER HEAD TANKS |
| 327 | 13.1 13.2 Heavy class G.I. Pipes excluding fittings with threaded joints(flanged) |
| 328 | 13.2.1 |
| 329 | 13.2.2 |
| 330 | 13.2.3 13.3 G.I Equal / Reducing Elbows threaded -UNIK Make heavyclass. |
| 331 | 13.3.1 |
| 332 | 13.3.2 |
| 333 | 13.3.3 13.4 G.I Equal / Reducing TEEs Threaded -UNIK Make heavy class. |
| 334 | 13.4.1 |
| 335 | 13.4.2 |
| 336 | 13.4.3 13.5 GI Threded Coupling heavy class. |
| 337 | 13.5.1 |
| 338 | 13.5.2 |
| 339 | 13.5.3 |
| 340 | 13.8 Total of Plumbing Works for Tanks 14 BOUNDARY WALL AND LAND DEVELOPMENT |
| 341 | Total of Boundary Wall & Land Development |
| 342 | 24.0 Total 14072442.04 Rebate @ (-)5.89% gd TOTAL AMOUNT (NDSR) including GST@12% after [email protected]% Sch-C DSR-2025 Electrical Items Item reference no. Description Unit Rate Quantity Amount |
| 343 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 344 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 345 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 346 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 347 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 348 | Supplying, Installation, Testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto10Amp , for mounting height up to 3 meter and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc.complete as required. |
| 349 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 8.2.1 12 -15 watt Each 715.0 125.0 89375.0 |
| 350 | LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt )Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), lifetime of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 8.5.3 12 -15 watt Each 1187.0 25.0 29675.0 |
| 351 | ≥120 <135 lm/Watt)Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver& electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body Thickness > 1.20 mm) 8.7.3 22 watt Each 2695.0 30.0 80850.0 |
| 352 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not riseabove 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 8.10.2 36 watt Each 760.0 504.0 383040.0 |
| 353 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electricalcircuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 8.13.13 72 watt Each 2128.0 20.0 42560.0 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 yearOEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 8.16.1 50 watt Each 2009.0 10.0 20090.0 8.16.2 70 watt Each 2299.0 10.0 22990.0 |
| 354 | Brush Less Direct Current (BLDC) Fan withoutRemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. 9.2.1 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery130 CM/Min (Minimum) Each 2560.0 5.0 12800.0 9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) Each 2695.0 100.0 269500.0 |
| 355 | Brush Less Direct Current (BLDC) Fan withRemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, remote (preferably mobile app based) for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. 9.1.1 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery130 CM/Min (Minimum) Each 2737.0 5.0 13685.0 9.1.3 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) Each 2882.0 100.0 288200.0 |
| 356 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete asrequired. 15.16.2 90 mm dia (OD-90 mm & ID-76 mm nominal) Meter 336.0 100.0 33600.0 15.16.3 120 mm dia (OD-120 mm & ID-103 mm nominal) Meter 417.0 100.0 41700.0 |
| 357 | (a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required :(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal asrequired.(c) Suitable HP Squirrel cage induction motor,TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supplywith IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e)Suitable cement concrete foundation duly plastered with anti vibration pads. 27.1.2 2850 lpm at 70 m Head Each 425556.0 1.0 425556.0 27.1.8 1620 lpm at 70 m Head Each 349421.0 1.0 349421.0 Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point. |
| 358 | (a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)(b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018. 27.3.2 180 lpm at 70 m Head Each 109254.0 1.0 109254.0 |
| 359 | (a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal asrequired.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling ,coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 27.4.2 450 lpm at 35 m Head Each 91384.0 1.0 91384.0 PIPES & ACCESSORIES27.6 Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows,tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providingcement concrete blocks as supports, anticorrosivetreatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 27.6.2 150 mm. Dia Meter 5104.0 50.0 255200.0 |
| 360 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling withsuitable clamp/support frame and painting with twoor more coats of synthetic enamel paint of require shade complete as required : 27.7.1 25 mm dia Meter 920.0 10.0 9200.0 27.7.2 32 mm dia Meter 1039.0 10.0 10390.0 27.7.4 50 mm dia Meter 1557.0 10.0 15570.0 27.7.5 65 mm dia Meter 1955.0 10.0 19550.0 27.7.6 80 mm dia Meter 2277.0 50.0 113850.0 27.7.7 100 mm dia Meter 3077.0 50.0 153850.0 27.7.8 150 mm dia Meter 4299.0 200.0 859800.0 |
| 361 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required 27.9.2 Single headed Stainless steel Each 6632.0 6.0 39792.0 27.10.2 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Each 6632.0 3.0 19896.0 |
| 362 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 27.11.3 65 mm dia Each 4712.0 1.0 4712.0 27.11.4 80 mm dia Each 5406.0 3.0 16218.0 27.11.5 100 mm dia Each 7271.0 1.0 7271.0 27.11.6 150 mm dia Each 9737.0 3.0 29211.0 |
| 363 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 27.14.4 80mm dia Each 8255.0 1.0 8255.0 27.14.5 100mm dia Each 11853.0 1.0 11853.0 27.14.6 150mm dia Each 18884.0 1.0 18884.0 |
| 364 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 27.15.3 150mm dia Each 11682.0 1.0 11682.0 27.15.4 200mm dia Each 23571.0 1.0 23571.0 |
| 365 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 27.16.2 Stainless Steel (Grade 304) Each 4667.0 12.0 56004.0 |
| 366 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm 27.17.2 40 m Each 17034.0 6.0 102204.0 |
| 367 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable forinstantaneous connection to interconnect hose pipe coupling as required: 27.18.2 Stainless Steel (Grade 304) Each 3202.0 6.0 19212.0 |
| 368 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories : 27.21.1 Pendent Sprinkler Each 599.0 10.0 5990.0 27.21.2 Upright Sprinkler Each 599.0 10.0 5990.0 27.21.3 Horizontal side wall sprinkler Each 699.0 10.0 6990.0 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread withmaximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mmNPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 27.25.1 700mm Each 1495.0 5.0 7475.0 27.25.2 1000mm Each 1703.0 5.0 8515.0 28.2.1 INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display withtouch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. 28.2.1.2 Two Loop Panel. Each 250420.0 1.0 250420.0 28.2.3 Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. Each 113734.0 1.0 113734.0 28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Each 3004.0 100.0 300400.0 28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Each 306.0 20.0 6120.0 28.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required. Each 3434.0 10.0 34340.0 28.2.9 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. Each 2866.0 1.0 2866.0 28.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required. Each 3156.0 1.0 3156.0 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. Each 4063.0 8.0 32504.0 28.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. Each 3682.0 8.0 29456.0 28.2.17 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. Each 6016.0 1.0 6016.0 28.5.1 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required. Meter 386.0 1200.0 463200.0 28.5.4 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. Meter 60.0 100.0 6000.0 Online UPS- Input supply: Three Phase, Output supply: Three Phase.Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current totalharmonic effect(ITHD) on the input grid shall be <5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitablesize and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3,IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display /LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c)Output: Voltage, frequency, Current. d) Battery:Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass /Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging,overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 26.2.2 20KVA (Each Power module shall be < 10 KVA) Each 341772.0 1.0 341772.0 Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set (One number only 160 KVA or 200KVA) as per CPCB IV +or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:(A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 MeterMSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as perISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication(vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication(x) Fuel Level (C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required asper specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cableconnection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection andenergy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2.Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9. Main supply failure monitor 10. Supply failure timer 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure(iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractorincluding all control wiring. 29.1.10 200kVA Each 1547620.0 1.0 1547620.0 Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressorand Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 32.2.3 1.5 TR with 5 Star BEE Rating Each 43539 Each 43539.0 2.0 87078.0 32.2.4 2.0 TR with 5 Star BEE Rating Each 57396 Each 57396.0 2.0 114792.0 Amount (including 18% GST) 7903089.0 Amount excluding GST (in INR) 6697533.0 Lump sum amount against Misc. DSR -2025 items 1000000.0 Total Estimate for DSR items (Excluding GST) 7697533.0 SCH D: NDSR Items E&M Item reference no. Item Description Unit Qty Rate Amount Schedule reference LAR contract reference E.00 General |
| 369 | The BOQ specified below include the latest relevent standards, specifications, drawing details and the contractor is required to go through them as referred in tender document while quoting the rates All the samples/ material intended to be used in the works shall be subject to approval before use as the Employer's representative may opt. |
| 370 | Sub-letting of work by the contractor shall only be permitted in accordance with Special Conditions of Contract. |
| 371 | Sub-letting of work by the contractor shall only be permitted in accordance with Special Conditions of Contract. |
| 372 | The items indicating one quantity can also be operated and variation clause shall be applicable as stipulated in GCC / SCC. |
| 373 | Bus Bar Sizing calculations shall be submitted for approval of Employer or Employer's representative. |
| 374 | Contractor's shall quote reasonably rates against each item of BOQ (both in word and figure) |
| 375 | For approved list of makes, refer specifications E.01 M V SWITCHGEAR |
| 376 | Switch Boards/panels Supply, installation, testing & commissioning of front operated front access cubical type indoor duty floor / wall / recess/ surface mounting, totally enclosed dust and vermin proof (minimum protection IP 54) panels with neoprene gaskets, fabricated from 2 mm thick Cold Rolled Close Annealed CRCA sheets with powder coated finish (minimum thickness 50 micron) suitable for 415 volts 3 phase 4 wire 50 Hz system to withstand symmetrical fault level of 50kA at 415 V including interconnections, bonding to earth etc. and flush doors conforming to relevant IEC/IS (viz. IEC 61439, IS 8623 etc.) standard including the earth leakage protection complete as per specification & drawings as required and as given below. All internal wiring in the panels shall be carried out using high temperature FRLS PVC wires. All panels shall be of Totally Type tested Assemblies (TTTA) confirming to IEC 61439 (TTTA with Form 4B, type-5) including Earth fault protection complete as per specifications. a) The Switchboards shall be provided with detachable gland plates minimum of 3mm thick for entry of cables from the top/bottom as required. b) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars shall be insulated with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports suitably spaced shall be used. Hinged doors with padlocking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position. c) The panel shall have tinned copper busbars with bar type feeder connections, spacers etc. and neutral busbar shall be of 100% capacity. d) Earthing all components, frame etc. to a common internal earth bar of copper/aluminium as per earth fault calculation. Approval from Engineer shall be obtained by the Contractor e) All accessories & supporting structures such as channels, ISMC base frame, mounting brackets, lifting lugs, panel heaters, ventilation arrangement etc as required. f) Each incomer and outgoing feeder shall be provided with suitably rated MCB controlled multiple LED lamps (Red, Yellow, Blue) for Phase indication and (Red, Green, Amber) for ON, OFF & Trip status with all required accessories suitable for 230 VAC operation as approved. g) Space provision @ 15% for future expansion and Spare Breakers @ 20-25% shall be provided. h) The makes of components and accessories shall, to the extent practically feasible, be same for panels and boards for uniformity, standardization and replace ability and shall be applicable to all panels/ boards under the scope of work i) Switchboard including interconnections, labelling, earthing, associated foundation/masonry work & erection etc. complete as required. j) All MCCBs shall be current limiting type microprocessor based, rated for requisite specified Service short circuit breaking capacity (Ics) suitable for isolation conforming to latest IEC60947-2/IS13947-2 duly marked on MCCB, at operating voltage (Ue) of 415 V, insulation voltage (Ui) 750 V and with trip free mechanism, handle indicating ON/OFF/tripped position. The breaking capacity as mentioned shall be Ics values. k) All 4P MCCB has inbuilt feature of earth fault protection, whereas all TP MCCB's shall have external CT for neutral overload protection and earth fault protection. All TP MCCB's shall have external neutral for neutral overload protection and earth fault sensing as specified in BOQ. l) MCCBs shall be compact (As the Engineer may decide), suitably designed to provide protection of motors, cables, busbars to suit rated current, unbalanced power distribution as required and with front adjustable overload and short circuit releases and minimum electrical endurance of the order of 7000-8000 operation cycles (higher shall be preferred) for capacity of 100-250 amps. m) All the Panels shall be equipped with required accessories for establishing BMS connectivity through open protocol like Modbus and shall be able to remotely read the parameters. n) MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking capacity 10 kA at 415 V AC, current limiting type lower powerloss appx 40 - 70% of the stipulated value and suitable for magnetic releases operating between 3 to 5 times rated current for normal power distribution application and 5 to 10 times rated current for motor application duty, with minimum Electrical endurance of the order of 20000 operation cycles. o) Panel/board design shall be compact and components / accessories of compact sizes be used to economies the room space available. Employer reserve the right to seek compact items in place of larger ones p) All incomer ACB's shall be provided with minimum 2 NO + 2 NC auxiliary contacts and all MCCBs shall be provided with 2 NO + 2 NC auxiliary contacts, and there should be provision to add min. 6 Auxiliary contacts. q) The panels shall be fitted with Clean Agent based panel flooding system. Payment for fire tube system shall be made under separate item. Scheme of fire tube system shall be got approved by Engineer before proceeding with manufacturing and assembly. Contractor shall interface with OEM of Panel and fire tube and ensure that the provision for fitting of cylinder and tube shall be made in the Panel during manufacturing of Panel without compromising the Compliance of relevant IEC. r) All incomers of Main Panel and Sub Panels shall be provided with surge protection devices as per NBC 2016, in compliance with IEC 61643. s) Internal control wiring in the Starters shall be done with FRLS PVC insulated cables of adequate size. Internal wiring, contactors, relay contacts, push button contacts should be rated not less than 2.5 sq. mm. All incomers MCCBs (or otherwise mentioned) of Panels shall be motorized with RS 485 type communication port for BMS/SCADA functioning Various panels/boards as given below: |
| 377 | Essential Power Panel (EPP) complete with contactor based automatic changeover system as per specifications & Drawing as per following details: 1.2 (a) Essential Power Panel (EPP) No 1.0 605763.12 605763.12 SCH-D1 (ELEC.+ECS)-STN Pkg-5B with 5.89% below and price escalation @8% A INCOMER (Normal Supply) a) Incoming from B1 with 400 A, 415V, Ics=35 kA, FP, MCCB complete with variable overcurrent and short circuit releases for Normal Supply b) Incoming from B2 with 400 A, 415V, Ics=35 kA, FP, MCCB complete with variable overcurrent and short circuit releases bus for Normal Supply c) Contactor-relay based automatic changeover system complete. d) 2 set of Red/Green ON/OFF indicating lamps e) 2 set of three phase indicating lamps (red, yellow, blue) f) Amber healthy/ trip indicating lamps for above feeders. B INCOMING FROM DG PANEL 1 nos. 400 A, 415V, Ics= 35 kA, 4P, MCCBs complete with variable overcurrent and short circuit releases a) 1- set of Red/Green ON/OFF indicating lamps b) 1- set of three phase indicating lamps (red, yellow, blue) c) Amber healthy trip indicating lamps for above feeders C BUS COUPLER Electrolytic high conductivity tinned copper three phase and neutral busbars rated at 400 A as per specification, suitable with stand symmetrical fault level of 35kA at 415 V. The neutral busbar is to be of same size as phases. D1 BUSBAR-1 a) Electrolytic high conductivity tinned copper three phase and neutral busbars rated at 400 A as per specification suitable with stand symmetrical fault level of 35 kA at 415 V. The neutral busbar is to be of same capacity. b) All incomers shall be interlocked electrically & mechanically with contactor based automatic changeover system so that only one Supply is switched on at a time and fail safe restoration. D2 BUSBAR-2 Electrolytic high conductivity tinned copper three phase and neutral busbars rated at 400 A as per specification suitable with stand symmetrical fault level of 35 kA at 415 V. The neutral busbar is to be of same capacity. E1 Metering (at Busbar-1) a) 1 No., 230V, AC operated integral type Digital meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVRH, frequency, Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs and suitable size summating CTs for metering of all incomers and outgoing feeders supporting SCADA/BMS connectivity E2 Metering (at Busbar-2) a) 1 No., 230V, AC operated integral type Digital meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, frequency, Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs for metering of all outgoing feeders and supporting SCADA/BMS connectivity F1 OUTGOING UNITS (From Busbar-1) a) 3 no. 200A, 415V, Ics=35 kA, FP motorized MCCB’s with fixed neutral and with variable overcurrent and short circuit releases. b) 2 no. 125A, 415V, Ics=35 kA, TP MCCB’s with fixed neutral and with variable overcurrent and short circuit releases. c) 2 no. 63A, 415V, Ics=35 kA, TP MCCB’s with fixed neutral and with variable overcurrent and short circuit releases. d) 7 no. 40A, 415V, Ics=35 kA, TP MCCB’s with fixed neutral and with variable overcurrent and short circuit releases with multifunction meter. F2 OUTGOING UNITS (From Busbar-2) a) 13 no. 40A, 415V, Ics= 25 kA, TP MCCB’s with fixed neutral and with variable overcurrent and short circuit releases. |
| 378 | Fire Pump Panel (FPP) as per specifications & Drawing as per following details complete with contactor based automatic changeover system as per following details (NAN) Internal wiring in the Starters shall be done with FRLS PVC insulated cables of adequate size. Internal wiring, contactors, relay contacts, push button contacts should be rated not less than 2.5 sq mm. A INCOMER - I from MDB (Normal Supply) 1 no. 250 A, 415 V, Ics=35kA ,4P, MCCB with variable over current and short circuit releases having: a) 1 set of Red/Green ON/OFF indicating lamps b) 1- set of three phase indicating lamps (red, yellow, blue) c) Amber trip indicating lamps B INCOMER - II from DG set 1 no. 250 A, 415 V, Ics=35kA ,4P,MCCB with variable over current and short circuit releases having: a) 1 set of Red/Green ON/OFF indicating lamps b) 1- set of three phase indicating lamps (red, yellow, blue) c) Amber healthy trip indicating lamps C BUSBAR a) Electrolytic high conductivity tinned copper three phase and neutral busbars rated at 250 A having a maximum current density of 1.4 A per sq mm suitable to with stand symmetrical fault level of 35kA at 415 V. The neutral busbar is to be of capacity as phases b) Two incomers shall be interlocked electrically & mechanically with contactor based automatic changeover system so that only one Supply is switched on at a time. D OUTGOING a) 4 nos. 160 A, Ics=35 kA, 415 V, TP MCCB with fixed neutral and with variable overcurrent and short circuit releases a1) 4 nos. 75 HP, Star Delta starter comprising 3 Nos. TP contactor AC-3 duty Auto/Manual switch, Start Stop push button, bimetallic over current relays single phasing preventer and timer & with potential free contacts for remote monitoring and control. a2) 1 - set of each Red/Green ON/OFF indicating lamps a3) 1 no. for each feeder of AC operated, 3.5 Digit, independent Digital Ammeter Equivalent to SMP-45 with necessary Circuit MCBs and with suitable size CTs, connections as required for incoming feeder and suitable selector for measuring other circuit current a4) 1 set of each start stop push buttons. a5) Auto / Manual selector switch. a6) Amber healthy trip indicating lamps. a7) Provision of remote start of main fire pump should be kept by pressing of push button switch. This provision shall be extended up to station control room. b) 3 nos. 40 A, Ics= 25 kA, 415 V, TP MCCB with fixed neutral and with variable overcurrent and short circuit releases b1) 3 nos. 15 HP, Star Delta starter comprising 2 Nos. TP contactor AC-3 duty Auto/Manual switch, Start Stop push button, bimetallic over current relays single phasing preventer and timer & with potential free contacts for remote monitoring and control. b2) 1 – set of each Red/Green ON/OFF indicating lamps b3) 1 no. for each feeder of AC operated, 3.5 Digit, independent Digital Ammeter Equivalent to SMP-45 with necessary Circuit MCBs and with suitable size CTs, connections as required for incoming feeder and suitable selector for measuring other circuit current b4) 1 set of each start stop push buttons. b5) Auto / Manual selector switch. b6) Amber healthy trip indicating lamps c) 3 Nos.16A, Ics = 10kA, 220V, DP MCB (motor duty) each with following: c1) 3 nos. 3 HP pump DOL starter with bimetallic over current relay with potential free contacts for remote monitoring and control. c2) 3 set of Red/Green ON/OFF indication lamps c3) 1 no. for each feeder of AC operated, 3.5 Digit, independent Digital Ammeter Equivalent to SMP-45 with necessary Circuit MCBs and with suitable size CTs, connections as required for incoming feeder and suitable selector for measuring other circuit current c4) 3 set of start stop push buttons. c5) Auto / Manual selector switch. c6) Amber healthy trip indicating lamps d) 2 Nos.32A, Ics = 10kA, 230V, DP MCB with ON/Off indication lamps D Metering 1 No., 230V, AC operated integral type Digital meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, frequency, Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs and suitable size summating CTs for two incomer metering and all outgoing Feeders supporting SCADA/BMS connectivity E Auxiliary relay shall be provided which shall be activated by pressure switch for remote monitoring. d) All the contactors shall be provided with potential free contacts for remote monitoring and control. e) Various distribution boards as given below: |
| 379 | Adjustment rates for addition/deletion of supply & fixing of following including making of suitable holes/space in the panel/DBs and making good all external finishes, terminations etc. complete as required. a) Multiple LED/neon type indications No. 1.0 1524.68 1524.68 134.79 106.51 121.06 121.06 b) Astronomic digital Timer No. 1.0 3881.27 3881.27 7920.27 6258.43 7113.33 7113.33 c) Ammeter/Voltmeter (3.5 digit display) No. 1.0 4118.82 4118.82 1212.06 957.74 1088.57 1088.57 d) TP Contractor - 40/32 Amp. No. 1.0 4525.78 4525.79 2939.28 2322.56 2639.82 2639.82 e) Aux. Contact 1 NO + 1NC for MCB No. 1.0 1022.13 1022.13 381.39 301.37 342.54 342.54 |
| 380 | Adjustment rates for addition/deletion of compartmentalised switchgear in above panels/board of following rating including the supply, fabrication, extension, modification of the enclosure or in a separate enclosure, earthing ,basbar, other sub-systems, accessories etc complete as required and as per specifications and as specified in of item 1.0 above 1.15B a) 630A, 415V, Ics= 35 kA, 4P, MCCB with variable over current and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue) No. 1.0 69281.77 69281.77 63904.32 50495.8242857143 57393.5538831429 57393.5538831429 c) 400A, 415V, Ics=35 kA, 4P, MCCB with variable over current and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue) No. 1.0 57531.97 57531.96 50272.22 39724.0309821429 45150.3336143036 45150.3336143036 g) 250/200A, 415V, Ics=35 kA, 4P, MCCB with variable over current and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue) No. 1.0 49589.59 49589.6 43754.7 34574.0263392857 39296.8383372321 39296.8383372321 I) 160 A, 415V, Ics=25 kA ,TP, MCCB with variable over current and short circuit releases with heavy duty solid neutral link and 1-set of three phase indicating lamps No. 1.0 29597.41 29597.41 29582.39 23375.3706696429 26568.4463031161 26568.4463031161 n) 5-32A FP MCB 10 kA No. 1.0 3921.02 3921.02 3725.02 2943.43098214286 3345.50365430357 3345.50365430357 r) 5-32A DP MCB 10 kA No. 1.0 1916.5 1916.5 2097.63 1657.50227678571 1883.91708779464 1883.91708779464 t) 5-32A SP MCB 10 kA No. 1.0 882.06 882.06 1851.03 1462.64424107143 1662.44144440179 1662.44144440179 v) 16-32Amp DP RCCB, 30 mA No. 1.0 3398.6 3398.59 3331.65 2632.5984375 2992.2113840625 2992.2113840625 E.02 DISTRIBUTION BOARDS |
| 381 | Design, supply, installation, testing & commissioning of front operated front access cubical type indoor duty dead front wall / recess/ surface mounting, totally enclosed dust and vermin proof ( minimum protection IP 54 ) panels with foamed-in neoprene gasketted hinged doors, fabricated from 2 mm thick CRCA with powder coated finish suitable for 415 V, 3-phase, 4 wire, 50 Hz system including suitably rated insulated copper busbars, interconnections, neutral bar assembly, phase segregating barriers, LED indicating lamps for incoming and outgoing feeders,15% spare space for future expansion, knockouts and gland plates for entry of cables and conduits, all internal wiring using high temperature FR wires, independant terminals for each phase, earthing terminals and including the cost of providing Master key lock on the door and pad locking facility on door as well as at incomer, bonding to earth etc. complete as per specification, drawings as required and as under: a) MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking capacity 10 kA at 415 V AC, current limiting type lower powerloss appx 40 - 70% of the stipulated value and suitable for magnetic releases operating between 3 to 5 times rated current for normal power distribution application and 5 to 10 times rated current for motor application duty, with minimum Electrical endurance of the order of 20000 operation cycles. b) RCCB /RCBO conforming to IS 12640 shall be provided with 30mA sensitivity and electrically connected rated current capacity MCB for short circuit and over load protection as required c) All incomer MCBs of boards /panels shall be provided with NO/NC contacts as specified in specifications and drawings d) All the contactors shall be provided with potential free contacts for remote monitoring and control. e) Various distribution boards as given below: |
| 382 | Lighting Distribution Boards (LDB) Type-2 as per specification and Drawing as per following details. One lighting distribution board (LDB) unit consist of 2 compartments with respective incoming TPN MCBs, DP MCB RCCBs/ELCBs, set of contactors and outgoing SP MCBs each having indications for incoming & outgoing feeder status e.g. LDB-2 is combination of LDB 2/N and LDB 2/U connected to incoming Supplies from Normal & UPS respectively as per specifications and as shown on Drawing and as under:(Operational Rooms-Concourse Level) A Normal INCOMER a) 1 no. 40A TPN MCB b) 1 set of (ON) indicating lamps for each OUTGOINGS with feeder (ON) indication LED lamps a) 24 nos. 10A/20A SP MCB arranged in three rows and each row controlled by one no. 32A DP MCB ELCB/RCCB with feeder ON indication lamps a) UPS INCOMER B 1 no. 25A DP MCB ELCB/RCCB 1 set of (ON) indicating lamps for each OUTGOINGS with feeder (ON) indication LED lamps a) 10 nos. 10A SP MCB b) 1 set of (ON) indicating lamps for each OUTGOINGS with feeder (ON) indication LED lamps a) 10 nos. 10A SP MCB b) 1 no. 25A DP MCB ELCB/RCCB c) 1 set of (ON) indicating lamps for each E.03 MV CABLING & BUS TRUNKING Sch-D1 (ELEC.+ECS)-STN Pkg-5B with 5.89% below and price escalation @8% |
| 383 | Cable Laying Supply, laying, testing and commissioning of 1100 V grade, armoured, FRLS, XLPE, Aluminium (Al) / Copper (Cu) Conductor cables on existing trays/ walls/ columns /indoor /trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc. and including the cost of proper dressing of cables, markers providing identification tags, earthing of glands armouring etc. complete as per specifications, as required and as below. Note 1: All cables 16sq mm and above are AI condcutor unless specified otherwise. a) 3.5 core 300 sq mm Al Conductor M 300.0 1117.21 335160.3 939.49 742.364866071429 843.771906776786 253131.572033036 b) 3.5 core 240 sq mm Al Conductor M 125.0 919.56 114944.86 864.6 683.188392857143 776.511927321429 97063.9909151786 c) 3.5 core 185 sq mm Al Conductor M 100.0 735.83 73582.86 628.99 497.014419642857 564.906589366071 56490.6589366071 e) 3.5 core 150 sq mm Al Conductor M 50.0 608.71 30435.38 530.14 418.905267857143 476.127727446429 23806.3863723214 f) 3.5 core 95 sq mm Al Conductor M 50.0 525.2 26260.02 367.41 290.319508928571 329.977153848214 16498.8576924107 h) 3.5 core 70 sq mm Al Conductor M 50.0 345.18 17259.08 311.5 246.140625 279.763434375 13988.17171875 l) 4 core 25 sq mm Al Conductor M 50.0 205.07 10253.27 165.73 130.956294642857 148.844924491071 7442.24622455355 m) 4 core 16 sq mm Al Conductor M 200.0 156.82 31362.83 134.79 106.508169642857 121.057185616071 24211.4371232142 o) 2 core, 16 sq mm Al Conductor M 200.0 123.03 24607.48 101.84 80.4717857142857 91.4642316428571 18292.8463285714 s) 3 core 10 sq mm Cu Conductor M 75.0 318.0 23849.5 317.89 251.189866071429 285.502401776786 21412.6801332589 t) 3 core 6 sq mm Cu Conductor M 200.0 221.46 44292.74 239.61 189.3346875 215.1978058125 43039.5611625 u) 3 core 4 sq mm Cu Conductor M 100.0 170.36 17035.39 140.77 111.2334375 126.4279250625 12642.79250625 w) 3 core 2.5 sq mm Cu Conductor M 100.0 127.76 12776.54 100.95 79.7685267857143 90.6649075446429 9066.49075446429 1,1 A Cable jointing and termination of cable as per item 1.1 - including cost of Supplying and fixing, Crimping lugs(Cu/Al as required), double compression brass glands, insulation tape etc. complete as per specifications and as required. Both ends terminations shall be considered as one set (02 nos) for payment. Sch-D1 (ELEC.+ECS)-STN Pkg-5B with 5.89% below and price escalation @8% a) 3.5 core 300 sq mm Al Conductor Set 2.0 2767.02 5534.05 3028.14 2392.77133928571 2719.62390423214 5439.24780846428 b) 3.5 core 240 sq mm Al Conductor Set 4.0 2409.77 9639.1 3269.74 2583.67848214286 2936.60896280357 11746.4358512143 c) 3.5 core 185 sq mm Al Conductor Set 2.0 1700.85 3401.71 2884.38 2279.17526785714 2590.51060944643 5181.02121889286 e) 3.5 core 150 sq mm Al Conductor Set 2.0 1573.73 3147.46 1996.79 1577.82066964286 1793.35097311607 3586.70194623214 f) 3.5 core 95 sq mm Al Conductor Set 2.0 1301.85 2603.71 1942.87 1535.21424107143 1744.92450640179 3489.84901280358 h) 3.5 core 70 sq mm Al Conductor Set 2.0 1042.97 2085.94 1638.37 1294.60486607143 1471.44789077679 2942.89578155358 l) 4 core 25 sq mm Al Conductor Set 2.0 580.88 1161.75 1084.25 856.751116071428 973.783318526785 1947.56663705357 m) 4 core 16 sq mm Al Conductor Set 10.0 511.28 5112.79 1024.34 809.411517857143 919.977131196429 9199.77131196429 o) 2 core, 16 sq mm Al Conductor Set 6.0 429.68 2578.07 905.55 715.546205357143 813.289817008929 4879.73890205357 s) 3 core 10 sq mm Cu Conductor Set 2.0 426.84 853.68 426.82 337.264017857143 383.334282696429 766.668565392858 t) 3 core 6 sq mm Cu Conductor Set 10.0 414.77 4147.77 1247.0 985.352678571429 1119.95185446429 11199.5185446429 u) 3 core 4 sq mm Cu Conductor Set 2.0 350.17 700.35 935.5 739.212053571429 840.188420089286 1680.37684017857 w) 3 core 2.5 sq mm Cu Conductor Set 10.0 322.91 3229.12 346.14 273.512410714286 310.874206017857 3108.74206017857 |
| 384 | Cable Trays |
| 385 | Supply, fabrication & installation of perforated hot dipped galvanised (Galvanisation as per latest IS 4759/6745) double bended cable trays from 2 mm thick GI sheets continuously connected including horizontal and vertical bends, reducers, tees, and other accessories and duly suspended from the ceiling with 12 mm dia vertical GI rods supported by 40mm x 40 mm x 5 mm GI angle etc. (or installed on wall supported on suitable brackets as required) complete as per specifications, as required and as below. Note: Trays shall be supported adequately at minimum 1 m distance from the building structure / ceiling by means of painted / galvanized (as specified) MS structural members secured to the structure by dash fasteners or by grouting. This support should be capable of withstanding the weight equivalent of 3m length of the cables that can be laid in the trays. At turns the support has to be double and at both ends of the bend. a) 600 mm wide x 40 mm deep M 20.0 1403.0 28059.93 1181.1 933.28 1060.77 21215.4 b) 450 mm wide x 40 mm deep M 20.0 1134.76 22695.22 1190.05 940.35 1068.8 21376.0 c) 300 mm wide x 40 mm deep M 50.0 838.83 41941.43 736.82 582.22 661.75 33087.5 d) 150 mm wide x 40mm deep M 100.0 566.03 56602.83 507.18 400.76 455.5 45550.0 e) 100 mm wide x 40mm deep M 100.0 413.65 41365.18 449.29 355.02 403.52 40352.0 f) 50 mm wide x 40mm deep M 100.0 351.63 35162.96 341.0 269.45 306.26 30626.0 E.04 Conduit Wiring |
| 386 | Supply & laying of conduit and wiring and testing and Commissioning for the following light / Ceiling Fan/ Exhaust Fan / Bracket fan point/Signage with 3 x 2.5 sq. mm, 1100 Volt grade PVC insulated FR copper conductor wires in heavy gauge 25mm dia GI conduit surface run with GI saddles, or concealed or in GI raceway including chases and complete with GI junction boxes, pull boxes, inspection boxes, bends & other accessories etc. including insulated Protective Earth (PE) Conductor and earthing of switch boxes excluding the cost of switches/sockets and switch boxes.as specified and as under: a) First point controlled by one Switchboard / 10A MCB Each 100.0 5426.77 542677.69 3222.82 2546.60330357143 2894.46931483929 289446.931483929 |
| 387 | Secondary or looping points wiring as specified in 1.o above using 3x2.5 copper (P+N+PE) wires inb 25 dia GI conduit for lights , fans, socket outlets inlcuding providing terminal block, ceiling rose & other accessories etc as required (excluding the cost of switches, sockets & switchboxes) as per specifications and drawings as required |
| 388 | Supply & laying, testing and commissioning of conduit and wiring for the following 16A socket outlet point with 3 x 6 sq. mm, 1100 Volt grade PVC insulated FR copper conductor wires in heavy gauge GI conduit conduit surface run with GI saddles. a) One no. 16A socket outlet point controlled by one 16A switch. Each 80.0 10555.39 844431.41 6788.1 5363.81116071429 6096.50776526786 487720.621221429 |
| 389 | Secondary or looping 16A socket outlet points wiring as specified in 1.5 above using 3 x 4 sq. mm copper (P+N+PE) wires in 25mm dia GI for socket outlets including providing terminal block, ceiling rose & other accessories etc as required (excluding the cost of switches, sockets & switch boxes) as per specificatiins and drawings as required. NOTE:- With regard to Item Nos. 1.1 to 1.5, for further clarifications, the sample measurement system to be followed is given below :- a) In case of 10 nos. light fixtures looped together and controlled directly from one no. MCB in DB, quantity to be paid shall be 1 No. as per Item No. 1.1 or 1.3 as applicable and quantity to be paid shall be 9 Nos. as per item no. 1.2 or 1.4 as applicable. b) In case of 5 nos. light fixtures looped together and controlled from switch located in a room, quantity to be paid shall be 1 no. as per Item No. 1.1 and quantity to be paid shall be 4 Nos. as per item no. 1.2. Conduit & wire laid from MCB in DB to first light point via switch point shall not be paid separately and is included in the rate in item no. 1.1. Same shall be the case for item nos. 1.5 as applicable. |
| 390 | Supply& installation of following modular grid plat mounted switch/es and socket/s etc. on a suitable size mild steel electrogalvanised switch boxes complete in single or combination on prorata basis complete with the connections, earthing and testing as per specifications and as required:(Note the grid plate and MS BOX shall be selected suitably as per the requirement to fix the switches and sockets. |
| 391 | 6A modular switch |
| 392 | 1 no. 6A switch & 1 no. 6A socket |
| 393 | 1 no. 6A socket |
| 394 | 6/16 Amp Universal socket with 16 amp modular switch |
| 395 | Blanking Plate for Switch/Socket |
| 396 | 32A 3 pin industrial socket outlet with 32 A DP RCCB 30mA with MCB shall be of standard powder coated MS steel IP-55 enclosure, separately lockable. |
| 397 | Supply, installation and testing of 8 SWG GI wire for Earthing Purpose |
| 398 | Supply & installation of 75mm x 75mm x 50mm deep G.I box,1.6 mm thick for Data & Telephone. |
| 399 | Supply, installation, testing and commissioning of exhaust fan with fan guards on both sides, double ball bearings, class-E insulation, capacitor (pf 0.90 or better) complete with all other accessories as per IS 2312 and as required, of following sizes: |
| 400 | Size 450mm dia, 1400 rpm 4,2 Size 300mm dia, 1400 rpm No. 26.0 3083.66 80175.33 E.05 Bracket Fans Sch-D1 (ELEC.+ECS)-STN |
| 401 | Supply and installations of 230 V, 1-phase, 1440 RPM, sweep of appx. 400mm Bracket fan including mounting bracket, blades, starters & other standard accessories complete as required. |
| 402 | Air Circulator Fans 600 mm Sweep 600 mm sweep Air Circulator Fans minimum of 1400 rpm, Air delivery minimum of 400 m cube/minute, 230 to 240 volts, 1 phase, 50 Hz complete with stand,ground, regulator, pedestal as required. No. 10.0 8539.54 85395.38 Note: Air delivery shall be measured at 3.6 mtrs from fan. E.06 Protective Earthing Sch-D1 (ELEC.+ECS)-STN Pkg-5B with 5.89% below and price escalation @8% |
| 403 | Providing and making plate earthing station with 600mm x 600 mm x 6.3 mm GI plate electrode , 15 mm dia G.I.watering pipe, CI funnel with wiremesh charcoal/coke , salt, all earth work, masonry enclosure with frame, Heavy duty RCC top cover plate having locking arrangement,Disconnecting links, complete as required as per IS-3043-1987 for earthing. |
| 404 | Providing and making plate earthing station with 600mm x 600 mm x 3 mm Cu plate electrode , 15 mm dia G.I.watering pipe, CI funnel with wiremesh charcoal/coke , salt, all earth work, masonry enclosure with frame, Heavy duty RCC top cover plate having locking arrangement,Disconnecting links, complete as required as per IS-3043-1987 for earthing. |
| 405 | Supply and laying, Testing and commissioning of copper/GI Strips/wire for interconnecting the earthing stations ,panels, DBs etc. of the following sizes in built up trenches /surface/wall/ground complete with holes & fixing, jointing / terminating accessories as per specifications & drawing as required. (Quantity shall be paid as per the actual measurement as executed, however direct measurement shall not exceed the quantity indicated in drawing approved . |
| 406 | 50 mm x 6 mm GI strip |
| 407 | 25 mm X 6 mm GI strip Note-1: In case of non availability of any of the sizes mentioned above, next higher size available in market shall be provided at the same rate. Note-2: No additional payment will be made for providing Test Link & Main Earth Terminals (made out of GI/Cu strips from within the above sizes). The METs will required to be fixed on walls as required and will be required to be provided with 12/16/20mm holes for connections of individual equipments including of other contractors'. |
| 408 | Extra for bituminous coating and hessian tape wrap or polyethylene faced hessian complete for buried 50mm x 6mm or 75mm x 6mm strip as per specifications and drawings as required |
| 409 | Extra for GI / Electrolytic Copper test links/ termination With building pier continuity Conductor including termination plate, nut& bolts,fixing/welding etc as per specifications and as required. E.07 LIGHTNING PROTECTION |
| 410 | Earth terminations with 50 mm dia GI perforated pipe complete with 15mm GI watering pipe with funnel with wire mesh etc. complete as per specification and drawing as required E.08 EXTERNAL ROAD/LANDSCAPE LIGHTING SCH-C1 ELECTRICAL (Depot) Pkg-5B with 5.78% below and price escalation @8% |
| 411 | SITC of LED street light having maximum system wattage of 70W & Minimum system luminipus efficacy of 120 lumens per watt. The housing shall be made of pressure diecast aluminium & theluminaire shall be IP65. The luminaire shall employ a BIS registered driver with THD ≤10% @ full load, PF≥0.95. The driver shall be constant current & potted type with operating range of InputVoltage : 140-270V, inbuilt surge protection of 4KV, The driver efficiency should be ≥ 90% at full load. The luminiare shall use high power LEDs with CR≥70, SDCM≤5, CCT5700°K ± 300 °K. Similar to philips BRP062 LED84 CW SLC S1 PSUFRLS PXXXX |
| 412 | SITC of LED street light having maximum system wattage of 120W & Minimum system luminipus efficacy of 120 lumens per watt. The housing shall be made of pressure diecast aluminium &the luminaire shall be IP65. The luminaire shall employ a BIS registered driver with THD ≤10% @ full load, PF≥0.95. The driver shall be constant current & potted type with operating range ofInput Voltage : 140-270V, inbuilt surge protection of 4KV, The driver efficiency should be ≥ 90% at full load. The luminiare shall use high power LEDs with CR≥70, SDCM≤5, CCT5700°K ± 300 °K. Similar to philips BRP409 LED130 CW M2 FG PSUGR V3 FRLS PXXXX |
| 413 | External Lights Pole Supply, installation, testing and Commissioning of External lights as perspecifications and drawings complete with the following :- i) Bajaj Cat No BOP-1030 or equivalent from Philips/ Keselec with weldedbaseplate, pedestal of specified height to IS:2713 part II-1980 or latest as per specifications and drawings ii) 1:3:6 concrete foundation and pedestal coping 300 mm dia of height as perspecification and relevant IS and as required. Contractor to obtain approval of foundation design before proceeding further. iii) 6 ways, 20 A connector & 6A MCB mounted on 6mm thick painted GI plate, insulated and accommodated inside the pole with gasketted weather vermin proof , hinged lockable covered GI box or integrated cast box in pedestal asrequired. iv) Wiring to Luminaries from the MCB to fixture shall be with 3 X 2.5 sq mm copper,stranded conductor (P+N+PE) double sheathed wire and making connections & earthing of pole v) Painting of pole accessories with 2 coats of primer and 2 coats of oil paint ofapproved colour as per engineer. vi) Luminaire as specified with Lamps, necessary cross arm to the luminaire, integralcontrol gear and as under. |
| 414 | LIGHTING POLES 2.1.1 9.0 meter Hot Dipped Galvanised Octagonal with Single Overhang Arm No. 5.0 26305.91 131529.55 2.1.2 9.0 meter hot dipped galvanised Octagonal with single overhang arm & with foundation bolts, base plate complete with foundation, entry and exit pipes, control JB with connector generally as shown on drawings and as perspecifications. No. 5.0 27051.12 135255.56 E.11 DG Set Sch-D1 (ELEC.+ECS)-STN Pkg-5B with 5.78% below and price escalation @8% Design, Manufacture, Supply, Installation/ erection, testing and commissioning of exhaust piping of Class \\"B\\" MS(4.85 mm thick as per IS 1239) of suitable size as recommended by the Engine manufacturer including the cost of pipe supports, bends, flexible joints and insulation etc. complete as per tender specifications.The Length will be taken beyond the Exhaust Selencer of the Engine. |
| 415 | For DG sets upto 250 KVA ratings |
| 416 | Supply, Installation/erection, testing and commissioning of Residential/Critical/ Hospital grade Silence as per latest CPCB approval including baffle plates as per manufacturer's standard design. Number of silencers will be as per the Tender specifications pertaining to the Noise level and the price will be inclusive of all the silencers required for one DG set. a) For DG sets upto 250 KVA ratings No. 1.0 18411.67 18411.67 |
| 417 | FUEL OIL PIPING Design, Manufacture, Supply, installation testing and commissioning of fuel oil piping system of suitable size of Class B MS (4.85 mm thick as per IS 1239) pipes, cut to required lengths and installed with all welded joints including providing and fixing in position the necessary fittings like valves, elbows, tees, reducers, duly coated with one coat of primer and two coats of approved enamel paint complete as per specifications and as required between Day Oil fuel tank and DG set. |
| 418 | For DG sets upto 250 KVA ratings PORTABLE FIRE EXTINGUISHERS Sch-D2 (FF-station) Pkg-5B with 5.78% below and price escalation @8% Supply and installation of portable fire Extinguishers as described below: |
| 419 | Providing and fixing portable fire extinguisher, stored pressure dry powder type with cylinder initially fully charged with dry powder (ABC type) of 6 Kg, complete with pressre guage, standard discharge valve with tube, CI bracket for wall mounting etc. |
| 420 | Providing and fixing initially fully charged Portable Fire Extinguisher of 4.5 Kg. capacity, carbon dioxide type with cylinder with CO2 gas, complete with squeeze lever Discharge Valve, Discharge Tube Horn including CI bracket for wall mounting etc. |
| 421 | Mechanical foam type 9.0 liter capacity fire extinguisher (for DG room) |
| 422 | Providing and fixing fire extinguishers water type of Capacity 9 liter with internal plastic fitting and ISI marked as per IS-940 with Gun metal Cap co2 cartridge and Initial refil. Total estimated amount excluding GST (in INR) 6946907.0 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 22 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 22 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender