Shipping Government Departments Closing in 7 days TDR #56760510

Tender For General-Upgradation Of Shakthikulangara Fishing Harbour-Electrical Upgradation And Modernisation Of Sakthikulangara Fishing Harbour-General Electrical Work

Issued by Government Departments · Kollam, Kerala
Tender Value
33.03 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
7 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kollam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Upgradation Of Shakthikulangara Fishing Harbour-Electrical Upgradation And Modernisation Of Sakthikulangara Fishing Harbour-General Electrical Work

BOQ

Name of Work:- GENERAL-Upgradation of Shakthikulangara Fishing Harbour-Electrical Upgradation and Modernisation of Sakthikulangara Fishing Harbour-General Electrical Work
Sl. No. Item Description
1electrical work
21.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
31.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
41.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
51.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
61.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
71.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
81.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
91.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
101.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
111.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
121.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
131.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
141.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
151.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
161.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1790.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1890.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
191.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
201.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
211.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
221.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
231.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
2490.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
2590.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
2690.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
271.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
281.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
291.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
30OD3266/2026-2027:Supply and installation of 9 W, 230 V, 50 Hz LED Lamp on existing Batten Holder , Make Philips, Osram, Wipro or equivalent.
3190.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
32OD3284/2026-2027:Supply and installation of Heavy duty exhaust fan with 4metal blades, totally enclosed continuously rated capacitor started and run of 300mm ,1400Rpm,240V,90W, Max air delivery of 1710 m3/hr with suitable extra louvers ,fixing accessories complete as required. preferred make Almonard ELE.EXH.33127704 or equivalent
332.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
342.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole
352.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
362.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
372.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
382.19:Supplying and fixing 20 A,415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
392.4.1:Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 Way (4+12) Double door
4090.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
415.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
425.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
435.19:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
445.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
455.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
4690.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
4790.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4890.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
4990.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
5090.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
5190.12.5.43:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 35 sq mm
5290.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
5390.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
5490.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
5590.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
5690.12.7.44:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 50 sq mm
579.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
589.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
599.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
609.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
619.1.36:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35mm)
6290.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
6390.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
6414.6:Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
651.20.4:Supplying and fixing of following sizes of steel conduit along with accessories in surface/recessincluding painting in case of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required.40 mm
66OD983/2026-2027:Supplying and fixing surface /recess mounting Vertical TPN distribution board with Double door , dust and water proof IP 66 Hensel make FP VN 0812 opaque or equivalent , 8 way DB of poly carbonate enclosure and tinned copper 250 A bus bar, common neutral link, earth bar, DIN bar for mounting MCB's with provision for MCCB as incomer.
67OD984/2026-2027:Supplying and fixing surface /recess mounting Vertical TPN distribution board with Double door , dust and water proof IP 66 Hensel make FP VN 0402 opaque or equivalent , 4 way DB of poly carbonate enclosure and tinned copper 250 A bus bar, common neutral link, earth bar, DIN bar for mounting MCB's with provision for MCCB as incomer.
68OD989/2026-2027:Supplying and fixing HENSEL make KV -thermoplastic circuit breaker boxes IP65 with metric knock out for cable entry, 3 row 36 module size 295 x 583 x 129, KV 9336 M, with PE+N terminals, complete with all fixing accessories.
69OD1956/2026-2027:Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make BRES 64,or equivalent. 600 x 400 x 200mm Glass Fibre Reinforced Polyester Enclosure with hinged door, IP66, IK 10 outdoor meter box or equivalent with base plate for fixing of KSEB meter, cut out & Neutral link and with sufficient holes for fixing 3 No 80 A HRC fuse units with 63 A HRC fuse link and 1No 63A 2way neutral link. Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using suitable size cable complete as required.
70OD1953/2026-2027:Supply and installation of wall mounting cubicle type dust and vermin proof 300x300x170 mm, Hensel make polycarbonate Enclosure - IP66 size 4 box K0400 or equivalent in wall with all fixing accessories
71OD1955/2026-2027:Supply and installation of wall mounting cubicle type CAPE make BRES 64 or equivalent thermoplastic polycarbonate enclosure with hinged lid 600 x 400 x 230 mm ,with supply and fixing of 63 A ,16 kA,4P,MCCB With BUC rotary drive kit, inter connection using 10 sq mm PVC insulated copper wire . Necessary holes are to be provided in the box for entry and exit of wire and sealed the joint with suitable sealing agent ,etc. all fixing accessories complete as required.
72OD877/2026-2027:Supply conveyance installation testing and commissioning of weather proof type LED luminaire IP65 rated having power consumption of 34 /40 W and light output not less than 2100 lm with system efficiency >120 lumens/watt. The Luminaire housing made from superior quality of polycarbonate extrusion IP65 and IK 08 protection. The luminaire should be having minimum 30000 Burning hours with CRI >=80 and colour temperature (CCT)of 6500K. Preferred make Philips WT 150C LED 40S-6500 PSU L120 or equivalent
73OD1952/2026-2027:Supply and installation of LED Bulk Head fitting 10W with Aluminum die-cast housing and polycarbonate optic materials including connection etc. as required. The luminaire shall have IP66 protection, luminous flux 1100 lm, luminous efficiency 110 lumens/watt, cool daylight color and 6500k color temperature PHILIPS Endura LED Bulk Head model WT202W LED10S CW PSU S3 PC or equivalent.
74OD883/2026-2027:Fabricating supplying and fixing special clamping arrangement for fixing LED bay light and cable junction box to the beam using 500 mm long 50x6mm MS flat, 12mm dia MS round bar with U shape open hook fixed vertically to hang the luminaire welded to the 50x6 mm MS flat and 2 pieces of 1.1m 32 x 6mm MS flat welded to the rod for fixing the cable junction box . The entire arrangement is to be fixed to the beam using 6 x 25 mm SS bolt and nut 2 Nos on each. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of best quality epoxy paint of approved colour as per drawing.
75OD1939/2026-2027:Supply Installation testing and commissioning of sub main distribution board of OEM with MCCB as incomer and MCCB as out going. Incomer 160A MCCB as incomer Supply installation testing and commissioning of wall mount following type Sub Main Distribution Board (SMDB) with MCCB as incomer and MCCBs as outgoing devices Conforms to IEC 61439-2 DEKRA and ASTA certified Rating up to 250 A Short-time withstand current » 250A & 400A SMDB - 36 kA 1s ,Ingress protection - IP 43 Choice in number of outgoing ways - 4 Ready to use, off the shelf solution Suitable for range of MCCBs Metering & cabling extensions are available as accessories complete as approved by the Engineer in charge as required. Incomer 160A 25kA 4P MCCB ,Outgoing 40A, 16kA 3P MCCB-4 Nos ,including metering block of voltmeter, ammeter , side box, top bottom cover and corner box including all fixing accessories complete as required.
76OD1378/2026-2027:Leading and installation of existing GI pole up to 12 M from the store to the location as directed by the engineer in charge at site, including allayment and fixing the pole in the existing foundation with all expense at site, complete as required
77OD3267/2026-2027:Supply and installation of extra length of factory made foundation bolt of size M24 Galvanised MS bolt in RCC foundation with suitable stiffener piece etc. complete as required.
7890.15.1.3:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 175 mm bottom diameter thickness 3mm base plate dimensions of 275x275x16 mm suitable for wind speed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters
7990.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
8090.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
81OD1337/2026-2027:Supply and installing RCC precast well ring of size 750mm dia and 300m height complete with all expense at site as required.
8214.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
8314.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
8414.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
85OD878/2026-2027:Supply Conveyance, installation, testing and commissioning of 70 W, 120 - 277 V, LED Bay light output greater than 150 lumen/W with IP 65 protection, IK 08, with power factor greater than 0.95 at full load, internal surge protection up to 6 KV, and Aluminum pressure die-cast Powder coated housing, polycarbonate cover , RoHS compliant. Make Philips BY515P LED100S 5700 NB S1 PSU GR or Equivalent.
86OD3268/2026-2027:Labour for fixing existing flood light in existing mast including all fixing accessories as direction by the engineer in charge at site.
87OD3270/2026-2027:Labour for dismantling existing temporary wiring auction hall as the direction by engineer in charge at site
88OD3269/2026-2027:Documentation Charges for KSEB New connection
89OD3271/2026-2027:Installation, Programming ,testing and Commissioning of existing 8 meters hot dip galvanized Octagonal Pole with 4nos of 80w Non integral Solar Floodlight System with 24 hours backup and dimming option including Wiring and all fixing accessories , as direction by the engineer in charge at site
905.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
91OD3281/2026-2027:Supply and wiring with ISI marked, FRLS PVC,UV Protected insulated following size single core Copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc with sockets as required. 4.00 Sq.mm Double run
92OD3282/2026-2027:Supply and Fixing of high-quality bird and pigeon spikes (6/4/BS-18-1-64BS18) for using prevent birds from settling on solar panels. These spikes act as an effective deterrent, ensuring that birds do not nest or perch on the panels, which can cause damage, reduce efficiency, and lead to maintenance issues. Made from durable materials, the spikes are designed to withstand various weather conditions while ensuring the safety and cleanliness of your solar panel system.
9390.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
94Civil Work
952.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
964.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
977.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
985.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
995.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
1005.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
1014.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
10250.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
1035.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1045.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
1055.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
10613.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10713.9.2:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster
10815.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
10915.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56760510
AUTHORITY Government Departments
TENDER VALUE 33.03 Lakhs
LAST DATE 07-08-2026
Authority
Authority Name Harbour Engineering Department
Work Description Tender for General-Upgradation Of Shakthikulangara Fishing Harbour-Electrical Upgradation And Modernisation Of Sakthikulangara Fishing Harbour-General Electrical Work
Basic Detail
Tender No HED/CEHED/TR/262/2026_6_1_1/1
Bidding Type Tender
Location
City Kollam
State Kerala
Key Dates
Publish Date 30 Jul 2026
Submission Date 07 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 33.03 Lakhs
Tender Fee 2760
EMD 50000
Exemption Not Available
Document List
9631986e-6ce0-427c-98a3-721158632c96.html
BOQ_1460469.xls
Tendernotice_1 (10).pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

9631986e-6ce0-427c-98a3-721158632c96.html

xls

BOQ_1460469.xls

pdf

Tendernotice_1 (10).pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender