Tender For Repair And Maintenance Of Lt Ug Cables, Cable Joint & Connected Items In Zone B Of Tech Area Under Ge (Af) Tech Area Agra.
Tender Value
35 Lakhs
Estimated cost
Bid Submission
21 Aug 2026
18 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Lt Ug Cables, Cable Joint & Connected Items In Zone B Of Tech Area Under Ge (Af) Tech Area Agra.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out etc complete all as specified and directed. |
| 2 | Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in soil etc complete all as specified and directed. |
| 3 | Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point etc complete all as specified and directed. |
| 4 | Supply and Laying double walled corrugated (DWC) HDPE duct pipe in 6 mtr lenght conforming to IS 16205 Pt-24 of approved color complete with fittings for cable protection of size 50mm outer dia and 38mm inner dia complete all as specified and directed. Make:- Astral/ Universal/ Dutron/SFMC as approved by GE. |
| 5 | Description all as per item No 4 above but 63mm outer dia and 50mm inner dia and ditto |
| 6 | Description all as per item No 4 abovebut 75mm outer dia and 63mm inner dia |
| 7 | Description all as per item No 4 above but 90mm outer dia and 75mm inner dia |
| 8 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 10sq mm, 4 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 9 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 16sq mm, 4 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 10 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 25sq mm, 4 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 11 | Supply and lay in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 35sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 12 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 50sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 13 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 70sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 14 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 95sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 15 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size size 120sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 16 | Supply and lay in repair / replacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size size 240sq mm, 3.5 core in trenches or fixed on wall/floor/poles etc complete all as specified and directed. |
| 17 | S&F in repair cable jointing kit suitable for LT 1100 volts cable (earthed) for out door , straight through joints, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable etc complete all as specified and directed of the following sizes :- |
| 18 | 10 to 50 Sqmm 3.5 core / 4 core |
| 19 | 70 to 120 Sqmm 3.5 core |
| 20 | 150 to 240 Sqmm 3.5 core |
| 21 | M&L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100 mm bore GI tubing of any description below/under road surface/floors etc with using manual devices as required at site including making good disturbed surface to match with the existing strata after laying pipes complete all as specified and as directed. |
| 22 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. |
| 23 | Demolition of PCC/Black bitumen road of any description and in any position not otherwise specially provided , etc complete all as specified and directed. |
| 24 | M&L for PCC (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, foundation panel board plat form etc complete all as specified and as directed including necessary from work. |
| 25 | M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces etc complete all as specified and as directed. |
| 26 | M & L for detecting the fault of underground LT cable by using fault locator machine including excavation required for fault confirmation and opening of cable connection from panel and re connection after fault location complete all as specified and directed.Note : The Fault locator machine shall be provided by the contractoras and when directed by engineer-in-charge. |
| 27 | Supply and fixing in repair 2 core, 4 Sqmm PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor etc complete all as specified and directed . |
| 28 | Supply and fixing in repair 2 core, 6 Sqmm PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor etc complete all as specified and directed . |
| 29 | Supply and fixing in repair 2 core, 10 Sqmm PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor etc complete all as specified and directed . |
| 30 | Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 1000mm width x 1000mm Height (With Canopy & Base Channel) x 500mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 400 Sqmm for cable termination, The Feeder Pillar box shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar box shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt. Bolts shall be grouted in PCC 1:2:4 type B1 (using 20mm graded aggregate) of suitable size of block. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed. |
| 31 | Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 750mm width x 750mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 300 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed. |
| 32 | Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 600mm width x 600mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 200 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed. |
| 33 | Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 500mm width x 500mm Height (With Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 100 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc including dismentling / taking out old unserviceable bus bar chamber complete all as specified and directed. |
| 34 | M&L for replacement of aluminium lugs for LT cable connection line suitable for system and fixed complete including taking down old unserviceable lugs and cables all as specified and directed of the following sizes :- |
| 35 | 16 to 35 Sq mm |
| 36 | 50 to 120 Sq mm |
| 37 | 240 to 400 Sq mm |
| 38 | S&F in repair cable route indicator made out of MS sheet of size 30cmx20cm of 4mm thick with writing HT/LT cable with MS angle iron frame and two Nos legs of 1.2 m long of size 25x25x5mm fixed in ground in PCC (1:3:6) Type C-1 using 20mm graded aggregate, size15cmx15cm x15cm including painting with 02 coats of synthetic enamel paint of specified colour over one coat of red oxide primer complete all as specified and directed. |
| 39 | Carryout day to day rectification of external electrifical complaints such as repair, reconnection and lightening of burnt/loose cable lead in MCCB/MCB of existing LT indoor/outdoor panels and bus bar with suitable size lug/thimbles, attending external electrical no supply complaints, jointing of traced out burnt cable with suitable size of jointing kit complete all as specified and directed.Note : (a) Replacement of major items shall be measured and paid under relevant items of this schedule.(b) Repairing upto 03 points at different electrical system without any other material will be considered as one job. |
| 40 | Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate shall be at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 25 x 4 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75 mm c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed. |
| 41 | Deduct Schedule of Credit of ₹ 120165.00 as brought out from serial page No 30 of tender Please Enable Macros to View BoQ information SCHEDULE OF CREDIT 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in ₹ Amount in ₹ |
| 42 | Old unserviceable LT UG cable of size 10 to 70 Sqmm 3.5 / 4 core of any type |
| 43 | Old unserviceable LT UG cable of size 95 to 240 Sqmm 3.5 / 4 core of any type |
| 44 | Old unserviceable bus bar chamber incld fittings of any type / size |
| 45 | Old unserviceable cable route indicator of any type |
| 46 | Old unserviceable aluminium lugs |
| 47 | Old unserviceable LT cable jointing kits of any type / size |
| 48 | Old Unserviceable aluminium conductor unarmoured cable of size 4Sqmm to 10 Sqmm, 2 core any type |
| 49 | Old unserviceable earthing of any type Total amount of credit schedule 120165.0 Signature of contractor AGE (Contracts) For ACCEPTING OFFICER |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender