Tender For Provn Of High Security Wall With Concertina Coil And Entrance Gate At 19 Weu Under Ge (N) Tezpur
Tender Value
12.60 Crore
Estimated cost
Bid Submission
28 Aug 2026
27 days left
EMD
9.55 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of High Security Wall With Concertina Coil And Entrance Gate At 19 Weu Under Ge (N) Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | M&L for dismantling old existing posts or struts (wood, steel or RCC), any section, including taking out embedded portion and making good disturbed ground embedded in concrete with and including clear vegatation on fencing and in floor area to facilatate demolition of any size and section complete all as specified and directed. |
| 2 | M&L for dismantling fencing wire mesh any type complete all as specified and directed. |
| 3 | M&L for dismantling mild steel work such as gate of any description not otherwise provided for complete all as specified and directed. |
| 4 | M&L for dismantling mild steel work as in barbed wire of any description not otherwise provided for complete all as specified and directed. |
| 5 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 6 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core with reduced neutral conductors (4 core), nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 7 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3.5 core with reduced neutral conductors (3.5 core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 8 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy Duty) with stranded copper conductor of size 1.5 sqmm, 3 core, 1100 Volts grade complete all as specified and directed |
| 9 | M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed by Engr-in-Charge.NOTE : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final. |
| 10 | M&L for returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cm in depth complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for sand cushioning in layers incl spreading, well ramming and watering complete all as specified and directed. |
| 12 | M&L for removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 13 | M&L for supply and lay of well brunt brick of sub class 'B' designation 75 for cable protection complete all as specified and directed. |
| 14 | Supply and fixing steel tubular poles type 410 SP - 31 (IS: 2713-1980) (9.00 metres long) including cast iron base plate, pole cap, swaged type, finial including foundation and coping complete all as specified and as directed. |
| 15 | S&F for 120 W new generation energy saving environmental friendly long life versatile pressure die cast aluminium IP-66 Bldg street light with high power LED as light source complete all as specified and directed. |
| 16 | M&L for street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape suitable fixing for Steel tubular LT poles with iron clamps of 02 sets including nuts bolts and washers including one coat of aluminium part over a coat of red oxide primer complete all as specified and directed. |
| 17 | M&L for junction boxes with new thermoplastic Cable Junction Boxes IP 66/67 \\"weather proof\\" for outddor installation with knockouts for cable entry with terminals suitables for 10-16 sqmm cable of size 155 x 210 x 92 mm aluminium busbar and MCB 6 Amps fixed and including necessary works and connecting all incoming and outgoing wires with AL lugs of appropriate sizes complete all as specified and directed. Please Enable Macros to View BoQ information |
| 18 | M&L for junction boxes with new thermoplastic Cable Junction Boxes IP 66/67 \\"weather proof\\" for outddor installation with knockouts for cable entry with terminals suitables for 10-16 sqmm cable of size 155 x 210 x 92 mm aluminium busbar and MCB 6 Amps fixed and including necessary works and connecting all incoming and outgoing wires with AL lugs of appropriate sizes complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 34 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender