Tender For Repair/Replacement Of Internal Fittings & Fixture, Led Bulb And Tube Lights, Distibution Board, Mcb And Connected Works In Offices/Otm Accn In Tech Area At Af Stn Ambala Under Ge (Af) Ambala
Tender Value
48 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
18 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Internal Fittings & Fixture, Led Bulb And Tube Lights, Distibution Board, Mcb And Connected Works In Offices/Otm Accn In Tech Area At Af Stn Ambala Under Ge (Af) Ambala
BOQ
| Sl. No. | Item Description |
| 1 | M&L for submain wiring in replacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 2.5 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed in new concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2.5 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old wiring and making good to the disturbed surface by plastering and applying two coats of distemper complete all as specified and directed.Note : Three runs of 2.5 sqmm cable alongwith conduit and conduit accessories will be measured as one length. |
| 2 | M&L for submain wiring in replacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed in new concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old wiring and making good to the disturbed surface by plastering and applying two coats of distemper all as directed at site complete all as specified and directed.Note : Three runs of 4 sqmm cable alongwith conduit and conduit accessories will be measured as one length. |
| 3 | M&L for submain wiring in replacement with 4 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25 mm dia or higher as per IS specification fixed in new concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old wiring and making good to the disturbed surface by plastering and applying two coat of distemper all as directed at site Note : Five runs of 4 sqmm cable alongwith conduit and conduit accessories will be measured as one length. |
| 4 | M&L for submain wiring in replacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed in new concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old wiring and making good to the disturbed surface by plastering and applying two coat of distemper complete all as specified and directed Note : Three runs of 6 sqmm cable alongwith conduit and conduit accessories will be measured as one length. |
| 5 | M&L for submain wiring in replacement with 4 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25 mm dia or higher as per IS specification fixed in new concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old wiring and making good to the disturbed surface by plastering and applying two coat of distemper complete all as specified and directed.Note : Five runs of 6 sqmm cable alongwith conduit and conduit accessories will be measured as one length. |
| 6 | S&F in replacement sheet metal enclosures for 4 way MCCB incomer + 12 module outgoings , vertical TPN load line distribution board with provn of mounting MCCB upto 100 amp 415 V incomer double door IP 54 protection As per IS 8623-3, 200 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed. |
| 7 | S&F in replacement sheet metal enclosures for 8 way MCCB incomer +24 module outgoings , vertical TPN load line distribution board with provn of mounting MCCB upto 250 amp, 415 V incomer double door IP 43 protection As per IS 8623-3, 315 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed. |
| 8 | S&F in replacement sheet metal enclosures for MCB distribution board 415 Volts three pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 9 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 10 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 11 | S&F in replacement MCCB four pole 415 Volts, 100 A, 16 KA complete all as specified and as directed. |
| 12 | S&F in replacement MCB four pole 415 Volts, 63 A, 16 KA complete all as specified and as directed. |
| 13 | S&F in replacement MCBs 32 amp TPN C curve 415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 14 | S&F in replacement MCBs 32 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 15 | S&F in replacement MCBs 5 to 32 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 16 | Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete fittings such as switches, C/roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, fixture & fittings, tube light fittings, fan regulator, electric meters, meter box any type etc as directed by Engineer-in-Charge. and making good to the disturbed surface by plastering and two coat of distemper complete all as specified and directed. |
| 17 | M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 20mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with modular /normal sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisioning of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :- |
| 18 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 19 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed. |
| 20 | One 3 pin switch socket combination on same board with other switches complete all as specified and directed. |
| 21 | One bell point controlled by one bell push complete all as specified and directed. |
| 22 | All as per BOQ srl No. 17.00 described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed.. |
| 23 | M&L for point wiring in existing concealed conduit complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through including PVC casing caping and provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed.Note :-The rate of making good the surface,if any will be deemed in the rates quoted by the contractor. |
| 24 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 25 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed. |
| 26 | One 3 pin switch socket combination on same board with other switches complete all as specified and directed. |
| 27 | One bell point controlled by one bell push complete all as specified and directed. |
| 28 | All as per BOQ srl item No. 23.00 here-in-above described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed. |
| 29 | M&L for point wiring on wall/ surface in PVC casing caping of size 20mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through including PVC casing caping and provisioning of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed. |
| 30 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 31 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed. |
| 32 | One 3 pin switch socket combination on same board with other switches complete all as specified and directed. |
| 33 | One bell point controlled by one bell push complete all as specified and directed. |
| 34 | All as per BOQ srl item No. 29.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed. |
| 35 | M & L for point wiring in wall/ surface in steel conduit of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including steel conduit with all accessories including provisioning of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed. |
| 36 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 37 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed. |
| 38 | One 3 pin switch socket combination on same board with other switches complete all as specified and directed. |
| 39 | All as per BOQ srl item No. 35.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board. complete all as specified and directed. |
| 40 | S&F in replacement switch piano modular type 6 amp single pole flush type one way complete all as specified and directed. |
| 41 | S&F in replacement switch piano modular type 16 amp single pole flush type one way complete all as specified and directed. |
| 42 | M&L in replacement for socket outlet modular type 3 pin 6 amp flush type complete all as specified and directed. |
| 43 | M&L in replacement socket outlet modular type 3 pin 16 amp flush type complete all as specified and directed. |
| 44 | S&F in replacement modular type BLDC compatilble fan regulator electronic type 120 watt 2 module complete all as specified and directed. |
| 45 | S&F modular cover plate with frame for 3 module complete all as specified and directed. |
| 46 | S&F modular cover plate with frame for 4 module complete all as specified and directed. |
| 47 | S&F modular cover plate with frame for 6 module complete all as specified and directed. |
| 48 | S&F modular cover plate with frame for 8 module complete all as specified and directed. |
| 49 | S&F modular metal flush box 3 module complete all as specified and directed. |
| 50 | S&F modular metal flush box 4 module complete all as specified and directed. |
| 51 | S&F modular metal flush box 6 module complete all as specified and directed. |
| 52 | S&F modular metal flush box 8 module complete all as specified and directed. |
| 53 | M&L in replacement for switch piano flush type single pole, one way 6amp complete all as specified and directed. |
| 54 | M&L in replacement for switch piano flush type single pole, one way 15 amp complete all as specified and directed. |
| 55 | M&L in replacement for socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed. |
| 56 | M&L in replacement for socket outlet 2 in 1 , 3 pin 5 A and 15 A flush type complete all as specified and directed. |
| 57 | S&F in replacement ceiling rose 65x50mm three terminals 230 volt confirming to IS 14772 complete all as specified and directed. |
| 58 | S&F in replacement lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed. |
| 59 | S&F in replacement bell push modular type 230 Volt complete all as specified and directed. |
| 60 | S&F in replacement call bell ding dong 230 V single phase complete all as specified and directed. |
| 61 | S&F in replacement stepped type fan regulator electronic type in 5 step, 80-100 watt capacity switch/socket type complete all as specified and directed. |
| 62 | S & F in replacement Hylam Sheet of size 6\\" x 6\\" complete all as specified and directed. |
| 63 | S & F in replacement Hylam Sheet of size 11\\" x 6\\" complete all as specified and directed. |
| 64 | S & F in replacement Hylam Sheet of size 12\\" x 14\\" complete all as specified and directed. |
| 65 | S & F in replacement Hylam Sheet of size 10\\" x 12\\"complete all as specified and directed. |
| 66 | S & F in replacement Hylam Sheet of size 11\\" x 13\\" complete all as specified and directed. |
| 67 | S & F in replacement Hylam Sheet of size 9\\" x 6\\" complete all as specified and directed. |
| 68 | S & F in replacement of PVC round fan down rod hook cover plate of size 6\\" to 8\\" or as per existing size complete all as specified and directed. |
| 69 | S&F in replacement plug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified and directed. |
| 70 | S&F in replacement energy efficient slim type 4 feet LED tubelight fitting 1x18W compleate all as specified and directed.Note : The LED should Have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 stranded luminaries efficiency 100 lumen/watt |
| 71 | S&F in replacement recess/Surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 35 watt incl connecting with twin core twisted flexible copper conductor cable complete with all accessoriescomplete all as specified and directed. Note : The LED should have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 stranded luminaries efficiency 100 lumen/watt |
| 72 | S&F in replacement indoor decorative LED batten with opal diffuser with inbuilt LED tube 10W and driver designed with high transmitting optics for even light distribution IP 20 degree protection having length 620mm and PF 0.9, CRI> 70, L 70 and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed |
| 73 | S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, frame and louvers including nut bolts washer complete all as specifed and as directed |
| 74 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, of sweep 200m including nut bolts washer complete all as specified and as directed |
| 75 | S&F wall mounted fan of 450mm sweep with, air delivery 110 CMM, 1325 RPM,230 V Single Phase AC with oscillation machanism inclulding clamp, nuts bolts and washer for fixing in the wall complete all as specified and as directed Please Enable Macros to View BoQ information |
| 76 | S&F wall mounted fan of 450mm sweep with, air delivery 110 CMM, 1325 RPM,230 V Single Phase AC with oscillation machanism inclulding clamp, nuts bolts and washer for fixing in the wall complete all as specified and as directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender