Tender for Repair / Maintenance Of Solar Water Heater And Geysers At Aor Of Ge Nasirabad
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully aluminium/copper point wiring (power) of any type complete including fittings and fixtures such as switches,ceiling roses, pendants, holders , sockets, light fittings, removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls/ceiling/floor at various site etc, complete all as specified and as directed |
| 2 | Disconnecting of unserviceable sub main wiring of any size including conduit of any type and accessories & removing from site and making good the disturbed surfaces, complete all as specified and as directed |
| 3 | Disconnecting electric connections and taking down old unserviceable MCB DBs of any type including MCBs SPN/SP/TPN of any capacity,complete all as specified and as directed |
| 4 | M&L for point wiring with 2.5 sqmm single core multi stranded PVC insulated unsheathed (FRLS) cable for 15 Amp socket outlet on independent board including non metallic rigid PVC concealed conduit 20 mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including one green colour cable of same size as earth wire up to common earth and connected to earth dolly complete all as specified and as directed |
| 5 | M&L for point wiring with 2.5 Sqmm single core multistranded unsheathed (FRLS) cable for 15 Amp socket outlet on independent board and including PVC casing & caping with all PVC casing caping accessories and sunk type pressed steel anodised terminal box with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including one green colour cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and as directed. |
| 6 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 7 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 8 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 9 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 10 | S&F in repair switch piano flush type 15 amps, single pole one way 240 volts complete all as specified and directed. Make : Cona / SSK / Havells |
| 11 | S&F in repair socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type ISI marked complete all, as specified & directed. Make : Cona / SSK / Havells |
| 12 | S & F in repair top plug three pin 15 Amp complete all as specified and directed.Make : Cona/ SSK/ Havells |
| 13 | S&F in repair MCB single pole 240 volt 10 KA breaking capacity, 6 to 32 Amp conforming to IS 8828 of 1996, Curve 'C' including connection with suitable size aluminium lugs complete all as specified & directed. Make : Legrand/ Siemens/ Schneider |
| 14 | Supply and fixing in repair of MCB SPN 10 to 40 Amp capacity, 10KA , 'C' Type instantaneous tripping complete all as specified and directed. |
| 15 | S&F in repair MCB single pole and neutral 240 Volt 10 KA breaking capacity, 25 to 32 amp conforming to IS 8828 of 1996, Curve 'C' including connection with suitable size aluminium lugs complete all as specified & directed.Make : Legrand/ Siemens/ Schneider |
| 16 | S & F in repairs heating element (Incoloy Glass coating or without glass coating ) size and make as per site requirement including rubber ring, washer, holding clamps and nuts of following capacity complete all as specified and directed.. |
| 17 | 1.50 KW capacity |
| 18 | 2.00 KW capacity |
| 19 | S & F in repairs thermostat (Normal or Capillary type) size and make as per site requirement of temperature variation ranging from 0 degree centigrade to 80 degree centigrade suitable for 25 litres and 50 litres capacity geyser complete all as specified and directed. |
| 20 | S & F in repairs heating element (Glass coating or without glass coating ) with inbuilt thermostat size and make as per site requirement including rubber ring, washer, holding clamps and nuts of following capacity complete all as specified and directed. |
| 21 | Taking down old unserviceable connection pipes any type and S & F stainless steel connection pipes, Mesh type heavy duty 15 mm bore, 60 cm long with two Nos PTMT nuts at both ends of approved quality complete all as specified and directed |
| 22 | Taking out old unserviceable apparatus plate assembly and supply & fix new apparatus plate size and make as per requirement with rubber gasket, nuts and bolts of suitable size for following capacity of Storage type heater (geyser) vertical type complete all as specified and directed :- |
| 23 | 25 Litres capacity |
| 24 | 50 Litres capacity |
| 25 | M & L for preparation of old outer surfaces of storage type heater (geyser) of following capacity, type and applying two coat of synthetic enamel paint (1st quality) of approved tint by spray and including writing MES No, figure (BLOCK, ROMAN or INDIAN) with black synthetic enamel paint (1st quality) 2cm high of complete all as specified and directed :- |
| 26 | 25 Litres capacity |
| 27 | 50 Litres capacity |
| 28 | S&F in repair geyser inner tank of following capacity made out of stainless steel sheet of existing gauge confirming to IS 6/8/9 hole as per existing geyser complete all as specified and directed :- |
| 29 | 25 Litres capacity |
| 30 | 50 Litres capacity |
| 31 | S&F in repair geyser inner tank of following capacity made out of copper sheet of existing gauge confirming to IS 6/8/9 hole as per existing geyser complete all as specified and directed :- |
| 32 | 25 Litres capacity |
| 33 | 50 Litres capacity |
| 34 | S & F in repairs Magnesium Anode rod with steel core size and make as per site requirement including rubber ring, washer, holding clamps and nuts of following capacity complete all as specified and directed.. |
| 35 | 1.50 KW capacity |
| 36 | 2.00 KW capacity |
| 37 | S & F in repairs multifunctional safety valve (MFV)size and make as per site requirement suitable for 25 litres and 50 litres capacity geyser complete all as specified and directed. |
| 38 | S & F in replacement thermal cutout size and make as per site requirement suitable for 25 litres and 50 litres capacity geyser complete all as specified and directed. |
| 39 | S & F in Shock Safe Plug size and make as per site requirement suitable for 25 litres and 50 litres capacity geyser complete all as specified and directed. |
| 40 | S & F in Mild Steel Pin type Anchor Fastener size 6/8 inches or as per site requirement suitable for hanging of 25 litres and 50 litres capacity geyser complete all as specified and directed. |
| 41 | Disconnecting & taking down carefully by any means of storage type water heater (geyser) 25/50 Ltr capacity, taking out heating element, thermostat and cleaning inner container by removing all scales etc and refixing/relocated of the same after grouting of New fastner after cleaning the existing space complete all as specified and directed. |
| 42 | S & Fix in repair LED indicator red/green colour of any type of geyser complete all as per specified and directed. |
| 43 | S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB SP `C' series for geyser & AC complete all as specified and directed. |
| 44 | M&L for Disconnecting, dismantling of solar water heating system including all water and electric connection of capcity 500 ltrs per day and re-fixing the same in existing position after the following repairs and testing omplete:-.(a) Replacement of the worn out/missing nuts bolts , washers, unions,socketsflanges and screw etc complete.(b) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaning and washing all copper tube & water circulated pipes of heat convetor sets throughly cleaning the complete solar panel of making the tube scale free and reassemling the panel.(c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete.(d) Repair of collector fins incl required welding works etc complete.(e) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects.Note:- The work shall be carried out by the company technician. The Spare parts such as Solar energy collector panel, toughned glass, rubber gasket, hose pipe, insulation for hot water pipe, heating element, thermostat, Water Storage tank, gate valve/float valve, MS Clamp shall be measured & paid separately under respective items. |
| 45 | All as per item no. 32.00 above here-in-before but of capacity 300 ltrs per day |
| 46 | All as per item no. 32.00 above here-in-before but of capacity 100/200 ltrs per day |
| 47 | S&F in repairs of Solar water Heater Inner Tank as per site requirement with Glass Wool complete of capcity 500 ltrs per day and re-fixing the same in existing position as specified and directed by Engineer -in -charge. |
| 48 | All as per item no. 33.00 above here-in-before but of capacity 300 ltrs per day |
| 49 | All as per item no. 33.00 above here-in-before but of capacity 100/200 ltrs per day |
| 50 | Supply and installation in replacement of complete one solar energy collector panel (FPC) A Type Size: 1860mm x 1240mm x 100mm or as per existing size and sample made of aluminium body with toughened glass complete with copper fins made of canandian technologies undercoat nickle including all accessories capable to heat 100 Litre water per day suitable to be fitted for 500 LPD, 300 LPD & 100 LPD Solar water heating system complete all IS 12933 Part-1 complete all as specified and as directed. |
| 51 | Supply and installation in replacement of Evacuated tubes made of borosilicate double glass suitable to be fitted for 500 LPD, 300 LPD & 100 LPD ETC type Solar water heating system and absorption not less than 90%, vacuum insulation for heat retention complete all as specified and as directed. |
| 52 | M&L for structural steel including nuts, bolts and washers incl welding, bending, cold or hot drilling holes for bolts in any shape or size as directed inclusive of one coat of primer and two coats of black paint complete all as specified and as directed. |
| 53 | S&F in replacement of Solar panel toughened/texture glass (1m×2m) or equivalent size as of existing having thickness 3.2 mm all as existing model of Solar panel system complete all as specified and as directed. |
| 54 | S&F in replacement of Rubber gaskets made out of fine rubber for Solar panel complete to make system air tight dust and water leak proof complete all as specified and as directed |
| 55 | S&F hose pipe 1\\" (25 mm) inner dia for hot/cold water for solar system of suitable length as existing size complete with 02 Nos clamps of required size complete all as specified and as directed. |
| 56 | M&L For insulation of hot water pipe with glass wool and covering with alluminium sheet cladding 25 gauge for 20/15 mm bore GI pipe complete all as specified and as directed. |
| 57 | S&F in repairs heating element for solar water heater of wattage 3.0 KW operating on 240 volts AC complete as per site requirement complete all as specified and as directed. |
| 58 | S&F in repairs thermostat for solar water heater of wattage 3.0 KW operating on 240 volts AC complete all as specified and as directed. |
| 59 | Taking Down / dismantling and S & F in repair white colour rotational moulded polyethylene (HDPE) water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted, tripple layer, ISI marked hoisted and fixed in position complete all as specified and directed.NOTE :- (i) The unit rate quoted by tenderer shall be deemed to insulate water tank with GI pipe medium grade 10cm long projected inside and outside of tank with bore suitable for inlet and outlet, GI pipe 20mm bore medium grade projecting 10cm inside and outside of the tank for over flow, GI pipe 20mm bore medium grade projected 10cm inside and outside of tank for vent & mosquito cover for vent/overflow pipe. |
| 60 | S&F in repairs ball brass valves high pressure with polythene float and fit nut complete screwed for iron pipe or brass ferrule and fixed of size 20 mm dia complete all as specified and as directed. |
| 61 | S&F in repairs 20mm bore gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipes and fixed all as directed. |
| 62 | S&F in repair of MS clamp for existing size of hose pipe complete all as specified and as directed. |
| 63 | S&F in repair of panel flange Rubber gasket Fine Rubber complete all as specified and as directed. |
| 64 | S&F in repairs mild steel water tubing 20 mm dia galvanised medium grade including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing complete all as specified and as directed. |
| 65 | S&F in repairs mild steel water tubing 15 mm dia galvanised medium grade including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing complete all as specified and as directed. |
| 66 | S&F in repairs MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 8 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.Note : MCB DB and MCB will be the same make. |
| 67 | S&F in repairs MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 12 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. Note : MCB DB and MCB will be the same make. |
| 68 | S&F in repairs MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 4 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. Note : MCB DB and MCB will be the same make. |
| 69 | S&F in repairs of MCB distribution board triple pole & neutral IP-43 double door metal, 4 way ,415 volt made out of CRCA sheet steel , factory made powder coated with insulated bus bars , shrouded neutral bars, earth bars , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed. |
| 70 | M&L for attending Geyser/Solar water heater complaints by opening / disconnecting the electrical connection from main switch, check the internal wiring of geyser, taking out the old unsv/defective wiring from existing connection rewiring the same with new wiring as per existing size of wire including providing necessary thimbles / connectors and make electic connection as functionable in all respects including testing on completion all as specified and directed by Engineer-in-charge. Note:- (A) The rate quoted shall deemed to be inclusive of the following: (i) Necessary wiring of appropriate size, Nut bolt and screws (ii) any welding works required (iii) Required numbers of electrician and helper shall be deployed for attending complaints regulerly on daily basis and contractor shall collect the complaints details from complaint cell of AGE E/M office/Online complaint cell and same shall be rectified/ attanded within day and report shall be submitted to Engineer-in-charge or their authorised representative. (B) Please note that payment shall be made to contractor one time only for this items. if any fault/ default occured again on the same location during currency of contract, the same shall be rectified by the contractor without any extra cost to Govt. in terms of condition 46 of IAFW of genral condition of contracts. |
| 71 | Supply and fixing in replacement Bib tap brass CP screwed for iron pipe of size 15 mm bore all as directed. |
| 72 | Cutting existing steel tubing for addition and alteration, screwing the existing steel tubing in position and insertion of required size of GI fittings. (i.e. union, nipple,reducing tee) for branch connection of internal dia 15 mm dia complete all as specified and directed. |
| 73 | Supply and fixing in replacement stop valve brass CP high pressure both ends screwed for iron pipe of size 15 mm dia complete all as specified and directed. |
| 74 | S&F in repair for Three core PVC insualated, FRLS, 1100 volts grade 2.5 Sqmm copper conductor wire for connection of geyser complete all as specified and directed. Please Enable Macros to View BoQ information |
| 75 | S&F in repair for Three core PVC insualated, FRLS, 1100 volts grade 2.5 Sqmm copper conductor wire for connection of geyser complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.