Tender For Repair And Maintenance Of Electrical Breakdown Incl Fault Detection, Localization And Rectification In Underground Network At Dk Part- 1,105 Ta, Rrrc, Icchamati Lines, Carriappa Vihar, Abdullah Dairy, Eme Stn Workshop, Kandhar Line, Taic,
Tender Overview
Project Description
Tender for Repair And Maintenance Of Electrical Breakdown Incl Fault Detection, Localization And Rectification In Underground Network At Dk Part- 1,105 Ta, Rrrc, Icchamati Lines, Carriappa Vihar, Abdullah Dairy, Eme Stn Workshop, Kandhar Line, Taic, Int Fs, 202 Cedu, Kandhar Line Officers Enclave, 8711 Field Ceremonial Battery, Kv 4, Padmini Acharya Marg, Lorry Road, Terrier Hostel And Adjoining Area Of Age (U) Elect Supply No. Ii, Under Ge (U) Elect Supply, Delhi Cantt-10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Aug-2026 | AMENDMENT NO 1 | Other | 20-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe (where provided for protection of cable or fixing with poles and stays) and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed by the Engr-in-Charge. |
| 2 | Material and labour for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the Engr-in-Charge. |
| 3 | Material and labour for removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 4 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by the Engr-in-Charge.Note : Measurement shall be taken after punning down. |
| 5 | S&F of sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by the Engr-in-Charge. |
| 6 | All as per srl item No 5 here-in-before but using old bricks obtained under srl item No1 here in before complete all as specified and directed by the Engr-in-Charge. |
| 7 | Supplying and laying of un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by the Engr-in-Charge. |
| 8 | All as per srl item No 7 here-in-before but using old un-reinforced precast concrete cable cove obtained under srl item No 1 complete all as specified and directed by the Engr-in-Charge. |
| 9 | Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by the Engr-in-Charge of the following sizes:-Note :- Excavation, earth work,cable protection, sand fillings, cable joint shall be measured and paid separately. |
| 10 | 16 Sqmm 4 core |
| 11 | 35 Sq mm 3.5 core. |
| 12 | 70 Sqmm 3.5 core |
| 13 | 95 Sqmm 3.5 core |
| 14 | 120 Sqmm 3.5 core |
| 15 | 185 Sqmm 3.5 core |
| 16 | 300 Sqmm 3.5 core |
| 17 | Supplying, laying, jointing, testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by the Engr-in-Charge of following sizes :-Note :- Excavation, earth work,cable protection, sand fillings, cable joint shall be measured and paid separately. |
| 18 | 95 sqmm 3 core. |
| 19 | 120 sqmm 3 core. |
| 20 | 185 sqmm 3 core |
| 21 | 240 sqmm 3 core |
| 22 | 400 sqmm 3 core |
| 23 | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by the Engr-in-Charge.Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of schedule(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule. |
| 24 | All as per item Ser No 11 above but 1100 Volt LT cables complete all as specified and directed by the Engr-in-Charge. |
| 25 | Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks acomplete all as specified and directed by the Engr-in-Charge.Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of schedule.(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule. |
| 26 | All as per item Ser No 13 above but 11000 Volt HT cables complete all as specified and directed by the Engr-in-Charge. |
| 27 | Material and labour for disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed by the Engr-in-Charge. |
| 28 | Supply, fixing and testing LT straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed by the Engr-in-Charge for the following sizes :- |
| 29 | 16-50 Sqmm x 3.5 core/ 4 core |
| 30 | 70-150 Sqmm x 3.5 core |
| 31 | 185 -300 Sqmm x 3.5 core |
| 32 | Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engr-in-Charge of following size :- |
| 33 | 95 Sqmm 3 core to 120 Sqmm, 3 core. |
| 34 | 150 Sqmm to 185 Sqmm, 3 core. |
| 35 | 240 Sqmm to 400 Sqmm 3 core |
| 36 | Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engr-in-Charge of following size :- |
| 37 | 95 Sqmm 3 core to 120 Sqmm, 3 core. |
| 38 | 150 Sqmm to 185 Sqmm, 3 core. |
| 39 | 240 Sqmm to 400 Sqmm 3 core |
| 40 | Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engr-in-Charge of following size :- |
| 41 | 95 Sqmm 3 core to 120 Sqmm, 3 core. |
| 42 | 150 Sqmm to 185 Sqmm, 3 core. |
| 43 | 240 Sqmm to 400 Sqmm 3 core Please Enable Macros to View BoQ information |
| 44 | 240 Sqmm to 400 Sqmm 3 core Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender