Tender For Repair/Replacement Of Unsv Led Street Lights, Tarmac Lights, Flood Light, High Mast Light And Other Connected Items In Tech Area At Af Stn Ambala Under Ge (Af) Ambala
Tender Overview
Project Description
Tender for Repair/Replacement Of Unsv Led Street Lights, Tarmac Lights, Flood Light, High Mast Light And Other Connected Items In Tech Area At Af Stn Ambala Under Ge (Af) Ambala
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Laying in replacement LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 4 core 16 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge. |
| 2 | Supply and Laying in replacement LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 3.5 core 25 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply and Laying in replacement LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 3.5 core 35 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply and Laying in replacement LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 3.5 core 50 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge. |
| 5 | S&F aluminium lugs for UG cable for 3.5/4 core 16Sqmm to 50Sqmm complete all as directed by Engineer-in-Charge. |
| 6 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth/width and getting out loose/soft soil for laying of under ground cable complete all as specified and directed. |
| 7 | All as per BOQ srl Item No. 6.00 here-in-above but for depth exceeding 1.50 m and not exceeding 3.00 m complete all as specified and directed. |
| 8 | Returning/ filling in including spreading, levelling and well ramming in layers not exceeding 25cm in thick complete all as specified and directed. |
| 9 | Removal of surplus soil to a distance not exceeding 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.. |
| 10 | Supply and lay dry river sand filling with and including punning for cushioning/protection to under ground cable with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. Note: Punned down thickness of 18cm shall be measured for payment only |
| 11 | Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying in trenches complete all as specified and directed. |
| 12 | M&L for Making bore to road/cement path/hard standing for providing GI pipe 50/40mm both end socketed for passing armoured cable including making good the disturbed surface complete all as specified and directed. |
| 13 | S&F in replacement GI tubing of 50mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete all as specified and directed. |
| 14 | S&F in replacement GI tubing of 40mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete all as specified and directed. |
| 15 | S&F LT end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5/4 core XLPE armoured aluminium conductor cable of size 16/25 Sqmm complete all as specified all as specified and directed. |
| 16 | S&F LT end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 35/50 Sqmm complete all as specified and directed. |
| 17 | S&F LT joint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sq mm complete all as specified and directed. |
| 18 | S&F in replacement automatic street light switch using timer for automatic switching of street lights, 5kW, single phase, based on LUX level of natural light, infrared sensor based on nature switch along with contactor 16A, MCB SP for input and output 32A, wiring for main load with 3 core 16sqmm copper cable duly fixed to pole/wall, mounted on enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box of protection class IP 54 fixed at any location complete all as specified and as directed |
| 19 | S&F in replacement automatic street light switch using timer for automatic switching of street lights, 8kW, single phase, based on LUX level of natural light, infrared sensor based on nature switch along with contactor 40A, MCB SP for input and output 63A, wiring for main load with 3 core 16sqmm copper cable duly fixed to pole/wall, mounted on enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box of protection class IP 54 fixed at any location complete all as specified and as directed |
| 20 | S&F in replacement automatic street light switch using timer for automatic switching of street lights, 18kW equally distributed over 3 phases, based on LUX level of natural light, infrared sensor based on nature switch along with contactor 25A/phase, MCB SP for input and output 63A, wiring for main load with 3.5 core 16sqmm copper cable duly fixed to pole/wall, mounted on enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box of protection class IP 54 fixed at any location complete all as specified and as directed |
| 21 | S&F in replacement junction box thermoplastic polycarbonate enclosure, shock proof, IP65/IP66 (weather, rust, dust, water and vibration proof, outdoor type, internally embedded gasket with provision for all side cable entry through glands of size 250x200x100mm with 4Nos. aluminium bus bar of size 25x6mm, 8Nos. terminals with and including 01No. 10Amp MCB 10kA duly mounted fixed with MS clamps fabricated out of FI 40x3mm of required shape and size and fixed to any location complete all as specified and as directed |
| 22 | M&L in replacement for true vertical steel tubular, swaged welded pole conforming to 1S-2713 part II, type 410 SP 31, 9 metre long complete with mild steel base plate of 6mm thick size 300mm X 300mm, finial taper plug, cap, boltes, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of zinc oxide primer for exposed surface and two coats of black bituminous paint for embeded portion in concrete as well as throughout internally including provision of white & blue colour strips with fluorescent paint upto 1.5 mtr height & numbering of pole complete all as specified & directed.Note (i) Excavation, earth work and PCC shall be measured and paid separately.(ii) Credit will be considered both RCC / Steel tubular poles as per site requiremet |
| 23 | M&L for cement concrete 1:3:6 type C-2 using (40 mm graded mechanically crushed stone aggregate) in foundation filling of poles/stays/plinths etc complete all as specified and directed |
| 24 | M&L for cement concrete 1:2:4 type B-1 using (20 mm graded mechanically crushed stone aggregate) in coping of poles including form work whereas required as per site requirement complete all as specified and directed |
| 25 | S&F in replacement LED smartbright solar street light 40 Watt, IP -65 with inbuilt lithium battery with poly crystalline PVC solar panel metal housing including GI bracket with nut bolts washer etc complete all as specified and directed |
| 26 | S&F in replacement energy efficient LED flood light fitting, 250W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD< 20, Aluminium housing including all fixing arrangement like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 27 | S&F in replacement energy efficient LED flood light fitting, 120W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD< 20, Aluminium housing including all fixing arrangement like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 28 | S&F in replacement energy efficient LED flood light fitting, 70W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD< 20, Aluminium housing including all fixing arrangement like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 29 | S&F in replacement energy efficient LED street light fitting, 120W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD< 20, Aluminium housing including all fixing arrangement like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 30 | S&F in replacement energy efficient LED street light fitting, 90W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD< 20, Aluminium housing including all fixing arrangement like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 31 | S&F in replacement energy efficient LED street light fitting, 45W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt,THD< 20, Aluminium housing including all fixing arrengment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 32 | S&F in replacement LED high / mid-bay light fitting 120W, 230V, PF 0.9, CRI >70, L 70, with pressure die cast aluminium housing, aluminium reflectors in commercial channel with powder coated Aluminium sheet housing with clear diffuser, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed |
| 33 | S&F in replacement LED high / mid-bay light fitting 150W, 230V, PF 0.9, CRI >70, L 70, with pressure die cast aluminium housing, aluminium reflectors in commercial channel with powder coated Aluminium sheet housing with clear diffuser, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod type complete all as specified and as directed |
| 34 | S&F in replacement flame proof weather proof energy efficient LED light fitting, 150W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-79, lumen efficacy ≥100 lumen/watt, THD< 20, Aluminium housing including all fixing arrangement like clamps, nuts, bolts, washers with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations/ height complete all as specified and directed. |
| 35 | S&F in replacement flame proof weather proof energy efficient LED flood light fitting 60W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-79, lumen efficacy ≥100 lumen/watt, THD< 20, Aluminium housing including all fixing arrangement like clamps, nuts, bolts, washers with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and directed. |
| 36 | S&F in replacement PVC insulated copper conductor cable, 3 core 1.5sqmm, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in connections complete all as specified and directed. |
| 37 | S&F in replacement security light bracket with 40mm bore GI tubing, light grade, cut and bent to shape required, 1.2m long fixed with including bends, flat iron clamp made of FI 40x6mm, nuts, bolts, washers, etc. duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specfied and as directed |
| 38 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 6 sqmm solid aluminium conductor complete all as specified and directed. |
| 39 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 10 sqmm solid aluminium conductor complete all as specified and directed. Please Enable Macros to View BoQ information |
| 40 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 10 sqmm solid aluminium conductor complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender