Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #56759633

Tender For Repair/Replacement Of Sluice Valve Ppr Pipe Lines, Gate Valve, Attending Day To Day W/S Complaints Cleaning Of Ug Sump Reservoir, Motor, Break Down Complaints, Repair To Roof Sheet False Ceiling Electrical Fittings Fixtures Of Dad, Ug Cabl

Issued by Statutory Bodies & Commissions/Committees · Ganjam, Odisha
Tender Value
32.27 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
21 days left
EMD
65000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganjam → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Sluice Valve Ppr Pipe Lines, Gate Valve, Attending Day To Day W/S Complaints Cleaning Of Ug Sump Reservoir, Motor, Break Down Complaints, Repair To Roof Sheet False Ceiling Electrical Fittings Fixtures Of Dad, Ug Cable, Panel Board, Switch Gear Etc At Different Pockets/Locations Under Ge (I) Gos

BOQ

Name of Work:- REPAIR/REPLACEMENT OF SLUICE VALVE PPR PIPE LINES, GATE VALVE, ATTENDING DAY TO DAY W/S COMPLAINTS CLEANING OF UG SUMP RESERVOIR, MOTOR, BREAK DOWN COMPLAINTS, REPAIR TO ROOF SHEET FALSE CEILING ELECTRICAL FITTINGS FIXTURES OF DAD, UG CABLE, PANEL BOARD, SWITCH GEAR ETC AT DIFFERENT POCKETS/LOCATIONS UNDER GE (I) GOS
Sl. No. Item Description
1M & L for carry out water quality anyalsis for bacterial ,chemical and biological analysis including for collection of water samples from the Tube well and testing from Govt approved testing laboratory , submitting of report from minium following parameters. (a) Turbudity (NTU) (b) pH (c) Total Hardness as CsCO2(mg/l) (e) Iron as Fe(mg/l) (f)Magnesium as Mg (mg/l) (g) E-coli or thermotolerantcoliform bacteria (h) from any NABL accredited lab.Notes: 1. Saperate water samples should be collected &tested from borewell. 2. No payment shall be made to contractortill submission of water test every two month report for the watersamples of pump house all as specified and directed.
2Supply and fixing 3 core copper submersible flat cable 10 Sqmm size, 1100 volts gradeIncluding taking down unserviceable burnt cable all as directed and specified by Engr-in-charge.
3Taking down old unserviceable and Supply and Fixing Submersible pump ,electric driven 415 volt 5 HP ,75 mtr head 180 LPM ,50 mm outlet including lowering by manpower and mechanical equipment complete all as secified and as directed.
4S&F in replacement of NON return valve 80 mm bore class PN - 1.6 with flanged including jointing materials,rubber gasket suitable size nut bolts and washer etc complete all as specified and directed.
5Supply only (Calcium based granular disinfectant for chlorination for water treatment, in Bbsr under AGE E/M GOS, GE (I) GOS in plastic drums fof 45 kg/each drum.
6Supply only alum crystal for water sedimentation complete all as specified and approved by GE.
7Cleaning of over head water storage tank of capacity 20000 gallons by dewatering existing water and removing all dirt silt vegetation formation on side walls/staire inside and bottom cleaning with wire brush to remove settled materials and cleaning with clean water and applying lime washing two coats inside the tank including re-writing the date of cleaning capacity of the tank/sump with synthetic enamel white paint on black base complete (ii) Cleaning the surrounding area of the reservior to a distance of 2 mtrs circumferance including cutting of grass digging out roots filling holes and levelling around and removing waster materials to a distance not exceeding 20 mtrs complete and all as directed.
8All as per item No 7 above but of capacity 10000 gallons UG sump complete all as specified and directed
9Flushing the bore well for flushing of silt, fine sand etc by air compressor of suitable capacity and pumping out turbidity till obtaining clear water all as directed and as per site requirement.
10S&F foot valve 50/63 mm dia CI/GI with complete fittings including taking out old unsv complete all as specified and directed.
11Taking down old unserviceable mild steelS & F Miled steel framed work such as angles,flat iron, grills,gratings,etc.with ends of bars shouldered and/or riveted or forged into spikes,framed guard bar,barred iron doors,ladder,framed balusters,ralling frame work etc including two coat of synthtic ename paint over a coat of red oxide in steel surface and similar work conforming to Fe-410-O or Fe-310-O complete all as specified and as directed by Engr-in-charge.
12Supply and fixing and testing CI sluice valves 100mm bore of dia both ends flanged and drill in with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.6) and confirming to IS 780 complete and of size 100mm dia
13All as per Item 12 above but of size 80mm dia
14Supply and fix in replacement of MCB TP 40 amps
15Supply and fix in replacement of electronic adjustable Cyclic timer 0-30 Seconds duration sutable to existing submersible motor panel board complete all as specified and as directed
16Supply and fix in replacement of dry Run Guard and overload protection with phase failure relay sutable to existing submersible motor panel board complete all as specified and as directed
17Supply and fix in replacement of Phase Monitoring Divice 440 volt 3 phase sutable to existing submersible motor panel board complete all as specified and as directed
18Supply and fix in replacement of Voltage Monitoring Divice 440 volt 3 phase sutable to existing submersible motor panel board complete all as specified and as directed
19S&F in repair DOL Starter for submersible pump set type MN -16 and relay range 9-15 Amps with contactor complete all as specified and as directed.
20Supply and fix in replacement of Push Button sutable to existing submersible motor panel board complete all as specified and as directed
21Supply and fix in replacement of Volt meter sutable to existing submersible motor panel board complete all as specified and as directed
22Supply and fix in replacement of Ammeter sutable to existing submersible motor panel board complete all as specified and as directed
23M & L for preparation of old steel surfaces and applying one coat of synthetic enamel paint in position to all surfaces for pump sets complete including base frames , Suction and discharge pipe lines, sluice valves , NRV ,including Iron removal plant , LT Panel Board etc pump house, writing of SM/MES No. neat and clean, visible size of letters and complete all as specified and directed.
24Replacement of impeller upto 7.5 HP submersible pump set
25Replacement of old rusted GI Column Pipe heavy grade of size 50 mm dia in pieces of 3.3 metre long , lathe m/c threaded both ends in the bore/open wells complete all as specified and directed.
26Replacement of old rusted heavy grade GI socket of size 50 mm dia complete all as specified and directed by EIC.
27S&F in repair HDPE Borecaps of size 200/250mm dia complete all as directed by Engineer-in-Charge
28Supply and fix in replacement over load relay 6 to 10 Amps for submersible motor panel board complete all as specified and as directed
29M & L disconnecting and taking down old unserviceable chlorination system and Supply Install test and commisioning of Chemical Dosing System of capacity 25 ltr/hrs at 10 kg/cm2 pressure coupled with 3 phase or single phase of capacity 0.5 Hp 1440 RPM with agiator dosing motor and agiator operated by single phase motor against rod (pvc) sweep blade FRP tank of capacity 150 ltr with inlet outlet connection and drain point hole complete all as specified and as directed.
30Taking down old unserviceable and Supply and Fixing Centrifugal pumpset ,electric driven,Three phase suitable for suction and delivery pipe line size 80 X 80 mm ,head 44 mtr,16 LPS of 15 HP (11 KW), complete fitting and testing ,alignment of motor complete all as secified and as directed.
31S&F of 3 layer PP-R (polypopropylene random co-polymer) pipes SDR 7.4/PN16 UV steblised and antimicrobial fusion welded having thermal estability for hot and cold water supply all PP-R plain end brass threaded polypopropylene randum fittings laid in trenches 63 mm O/D complete with all connected fittings incl taking down old unsv all as specified and directed (ISI marked)
32S&F of 3 layer PP-R (polypopropylene random co-polymer) pipes SDR 7.4/PN16 UV steblised and antimicrobial fusion welded having thermal estability for hot and cold water supply all PP-R plain end brass threaded polypopropylene randum fittings laid in trenches 32 mm O/D complete with all connected fittings incl taking down old unsv all as specified and directed (ISI marked)
33S&F of 3 layer PP-R (polypopropylene random co-polymer) pipes SDR 7.4/PN16 UV steblised and antimicrobial fusion welded having thermal estability for hot and cold water supply all PP-R plain end brass threaded polypopropylene randum fittings laid in trenches 25 mm O/D complete with all connected fittings incl taking down old unsv all as specified and directed (ISI marked)
34S&F in replacement of PP-R gate valve 63 mm (brass insert) O/D complete.
35S&F in replacement of PP-R gate valve 32 mm (brass insert) O/D complete.
36S&F in replacement of PP-R gate valve 25 mm (brass insert) O/D complete.
37S&F foot valve 50/63 mm dia CI/GI with complete fittings including taking out old unsv all as specified and directed as per sample approved by Engr-in-Charge.
38Taking down unsv pump set 5 HP capacity from connected pipe line, dismantling existing motor/pump, rewinding motor by supper enamelled copper wire with existing size, insulation and varnishing complete, replace wornout ball bearing and gland packing of existing pump set and refitting the repaired pump set on pipe line, testing and commissioning complete all as specified and directed.
39Taking down unsv booster pump 05 HP capacity, 3 phase from UG sump from existing connected pipe line, dismantling existing motor/pump, rewinding motor by supper enamelled copper wire with existing size, insulation and varnishing complete, replace wornout ball bearing and refitting the repaired booster pump on pipe line, testing and commissioning complete all as specified and directed.
40Dismantling asbestos cement (corrugated semicorrugated etc) sheet in roof covering complete all as specified and as directed.
41S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
42Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
43Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
44S&F for rolled mild steel in steel work tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
45M&L for painting steel and iron surfaces of steel surfaces of any description, over 10cm in width or girth, not otherwise described, applying two coats of synthetic enamel paint over coat of red oxide primer including preparation of new surface complete all as specified and directed
46Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
47M&L for Anodised aluminium snap grid size 605 X 605 mm frame work for false ceiling complete all as specified and as directed
48S&F for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed
49M&L for 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed
50M&L for preparation of new plastered surface of ceiling/boards etc and applying three coats of white wash complete all as specified and directed
51Excavation in trenches in hard/dense soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting GI/CI pipe line on cable trench complete all as specified and directed.
52Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
53Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
54Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
55M&L Brick work with modular fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed
56M&L for Providing precast cement concrete manhole covers, Type B1 1:2:4 (20 mm graded aggregate) set in cement mortar 1:4 complete all as specified and as directed
57M&L for Mild steel TMT bars 10 mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
58M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in cement Mortar in 1:4 using water proofing compound in top layer (Water Proofing Compound measured separately) and finished even and smooth (without using extra lime or cement) complete all as specified and directed.
59Supply only Liquid water proofing compound for external wall plastering (for 5 mm thick plastering) complete all as specified and directed
60Supply and fixing and testing CI sluice valves 100mm bore of dia both ends flanged and drill in with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.6) and confirming to IS 780 complete and of size 100mm dia.
61All as per Item 60 above but of size 80mm dia
62S&F 3-layer PP-R polypropylene random copolymer concealed pipe (PN 16/SDR 7.4) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings, floors or in trenches etc of size 110 mm OD complete all as specified and directed.
63All as per Item No. 62 above but of size 90 mm OD.
64All as per Item No. 62 above but of size 63 mm OD.
65All as per Item No. 62 above but of size 32 mm OD.
66All as per Item No. 62 above but of size 25 mm OD.
67S&F in repair of PP-R gate valves(brass inlet) as per requirement of size 110 mm OD complete all as specified and directed.
68All as per Item No. 67 above but 90 mm OD.
69All as per Item No. 67 above but 63 mm OD.
70All as per Item No. 67 above but 32 mm OD.
71All as per Item No .67 above but 25 mm OD.
72Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC casing caping with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note : two run 6sqmm and one run of earth wire 6 sqmm and PVC conduit will be measured as one length.
73Supply and fix Sheet metal enclosure for DB’s suitable for MCBs of single pole and neutral12 way (Double door) with 200 amp rated bus bar all as specified and directed.
74Supply and fix Sheet metal enclosure for DB’s suitable for MCBs of single pole and neutral 8 way (Double door) with 200 amp rated bus bar all as specified and directed.
75Supply and fix Sheet metal enclosure for DB’s suitable for MCBs of single pole and neutral 4 way (Double door) with 200 amp rated bus bar all as specified and directed.
76S&F Isolator DP 40A, 240 volts all as specified and directed by Engr-in-Charge.
77S&F MCB SP up to 40 Amp, 240 volt all as directed.
78Material and labour for PVC rectangular block of size 25 cmx20cmx5cm depth, closed recessed 3mm thick plastic laminated sheet complete all as specified
79S & F LED light fitting 1 x 10 Watt Alumnium batten type, indoor decorative PC housing extruded Al LED battens with extruded aluminium housing and integrated LED driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size incl taking down the old USNV complete all as specified and directed
80S &F Energy efficient LED integrated batten suitable for indoor applications tube light fitting 1x 20 Watt 4 FT complete all as specified and directed.
81Supply and fixing 5 star rating Ceiling Fan 1200 mm sweep with blade, down rod complete all as specified and directed.
82Supply and fixing exhaust fan 300 mm sweep, 1400 RPM with louver complete all as specified and directed.
83Supply only Oil filled capacitor of 2.5 MFD, 240 Volt suitable for ceilling/ exhaust fan complete all as specified and directed.
84S&F modular switch single pole 1 way 6A, complete Including taking down unserviceable switch all as specified and directed.
85S&F modular socket outlet 6A 2/3 pin combined 2 module complete Including taking down unserviceable socket all as specified and directed.
86S&F modular switch 16A single pole one way complete Including taking down unserviceable switch all as specified and directed.
87S&F socket outlet 6A/16A- 2/3 pin combined 2 module complete all as specified and directed.
88M&L for modular Bell push Switch single pole one way 6A/10Amps complete Including taking down unserviceable ones all as specified and directed.
89M&L for call bell modular type AC 230 volt single pole complete Including taking down unserviceable ones all as specified and directed.
90M&L for fan step regulator, 120, W-2 module complete Including taking down unserviceable ones all as specified and directed.
91Supply and fix LED Lamp pin type 9 watt all as specified and directed by the Engineer-In-charge.
92Supply and fix Thermal Magnetic release, MCCB 160 Amps 415 Volts, 4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fittings items Including Taking down old unservicable Mccb's all as specified and directed by Engr-in-Charge.
93Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables heavy duty 1100 volts grade, with stranded aluminium conductor with all fixing & connecting accessories such as aluminium cable lugs, cable gland, nut, bolts, washer etc Including taking out existing unserviceable cable of following sizes complete all as specified and directed:- (a) 4 core x 16 Sqmm
94(b) 2 core x 10 Sqmm
95Excavation in trenches in hard/dense soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out pole foundation/cable trench complete all as specified and directed.
96Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
97Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
98Supply and fixing street light fitting LED type 45 Watt new generation energy saving powder coated pressure die cast aluminum high powder with heat resistant toughened glass with lens & IP65 with high power LEDs as light source and electronic driver with GI tubing 40mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of flexible copper conductor of size 1.5 sq mm cable from fitting to junction box, testing & commissioning complete all as specified and directed.
99Supply and fixing decorative LED post top lantern luminaire with milky diffuser and painted aluminium deflector complete with connecting of suitable size of wire incl taking down old unsv all as specified and directed by Engr-in-Charge.
100Supply and fixing 9W decorative LED extruded aluminium bollard light with integrate driver complete with connecting of suitable size of wire incl taking down old unsv all as specified and directed by Engr-in-Charge.
101Painting to existing steel tubular LT poles , 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surface expose to view and making 30 cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC benching including prepration of old painted surface by scraping complete all as specified and directed by Engr-in-Charge.
102Trimming of trees and cutting of tree branches carefully upto 3 mtr clear distance from wire/cables/conductor/panel boards along LT over head electric line using all required safety equipment for each length of approx 40 metre long complete all as specified and as directed by Engr-in-charge
103Material & labour for decarbonising / cleaning LT Panel / pillar boxes of 415 Volts 3 phase bus bar chamber with electrical connections, removing all the bus bar links from the panel, checking its condition. Cleaning the total bus chamber with CTC solution / application of doctor bectol solution on complete bus bar. The painted bus bar links shall be heated in presence of metal halloid lamps until it achieves its meggar value. Using of vaccum cleaner is essential during decarbonising of panel. Checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts with new ones all as specified and directed.
104Material & labour for LT 1100 V end termination with suitable size of lugs duly crimped for LT 2 / 3.5 / 4 core armoured aluminum conductor cable of size any core,any size after isolating, supply to transformer / LT panel and disconnecting burnt / fault cable from the bunch of cables connecting back after end termination testing and commissioning all as specified and directed.
105Supply and providing sand cushioning with dry clean sand 8 cm below cable and 15 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
106Supply and laying Fly ash bricks in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
107Material and labour for filling the road / hard standings cut for laying cable with PCC 1:2:4, type B2, using 40 mm graded stone aggregate and finishing the surface even and smooth without using extra cement all as specified and directed.
108Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables heavy duty 1100 volts grade, with stranded aluminium conductor with all fixing & connecting accessories such as aluminium cable lugs, cable gland, nut, bolts, washer etc Including taking out existing unserviceable cable of following sizes complete all as specified and directed:-(a) 3.5 core x 150 Sqmm
109(b) 3.5 core x 50 Sqmm
110(c) 3.5 core x 35 Sqmm
111(d) 3.5 core x 25 Sqmm
112(e) 4 core x 16 Sqmm
113(f) 2 core x 10 Sqmm
114M & L GI tubing light grade 40 mm bore with all fitting(ISI marked) for protection of cable fixed to pole/wall / laid under floor or road including necessary joints and clamps complete all as specified and directed.
115Boring of holes horizontally for laying of pipe not less than 100 mm dia (min depth 0.90 mtr to 0.120 mtr from top level) under road, hardstanding by trench less technology for passing cable through pipe with mechanical/hydraulic/compresser pressure pump machine system throughly so the surface of road can not be disturbed or cracked all as specified and directed.
116Cutting wild grass, bushes, creaper, unwanted vegitation from inside / surrounding of installations including cutting creapers from barbed / cattle fencing of the installations as when directed and removing of unwanted material from installation compound and depositing where directed.Note : (a) The item shall be operated maximum four times in entire period of contract in the same installations. (Area measured separately each time). (b) Measurement of cleaning fencing will be measured based on the height between top line and bottom line of barbed wire/ chain link / cattle fencing multiplying by the length involved.
117Supply and fix Thermal Magnetic release, MCCB 400 Amps 415 Volts, 4 pole 36 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fitting items Including taking down old unserviceable Mccb's all as specified and directed by Engr-in-Charge.
118Supply and fix Thermal Magnetic release, MCCB 250 Amps 415 Volts, 4 pole 36 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fitting items Including taking down old unserviceable Mccb's all as specified and directed by Engr-in-Charge.
119Supply and fix Thermal Magnetic release, MCCB 160 Amps 415 Volts, 4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fittings items Including Taking down old unservicable Mccb's all as specified and directed by Engr-in-Charge.
120Supply and fix Thermal Magnetic release, MCCB 125 Amps 415 Volts, 4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fittings items Including Taking down old unservicable Mccb's all as specified and directed by Engr-in-Charge.
121Supply and fix Thermal Magnetic release, MCCB 100 Amps/80 Amps/63 Amps 415 Volts, 4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required items Including Taking down old unservicable Mccb's all as specified and directed by Engr-in-Charge.
122Supply & fix pole box of new technology made up of Thermoplastic Polycarbonate Pole box, install, testing and commissioning of Thermoplastic Polycarbonate Pole box which is shock, rust, dust, impact and water proof, halogen and silicon free, UV resistance with internally embedded gasket high grade gasket made of polyurethane. The thermoplastic pole box suitable size with degree of protection IP 65, type tested, system voltage – 230V , 50Hz, Capacity with temperature resistance of -40°C to 120°C, with cable entry ,suitable size of Glands, all as specified and duly mounted on steel tubluar pole with suitable MS flat with bolts nuts and washers complete including supply fixing and making provision of the following :- (a) MCB SPN 30/32 Amp.
123M & L in repair for installation, commissioning and testing factory made CPRI approved out door cubical type feeder piller box totally enclosed over all size not less than 750x600x750mm (LXBXH) fabricated with 3.15mm thick CRCA sheet (Heavy duty) over a frame of 40 x 40 x 6mm angle iron and mounted on platform all around and dust & vermin proof, IP-65 protection, back side openable, fixed with nuts & bolts and front side openable with hinged shutter and locking arrangement by operate alen key individuals for MCCBs and over all front panel double door shutter with powder coated finished both internally and externally suitable for 415 V, AC, 50 HZ, 3 Phase, 4 wire system by means of copper bus bar of size 50 x 5mm (Main) duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators with provision of fixing MCCBs necessary inter connections with copper strips of size 30x5mm duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators and providing following equipments including connection with all in coming/out going cables of different size duly crimping with suitable size copper lugs complete including taking out old unsvNote : Drawing shall be got approved by Engr-in-charge before manufacturing of the LT panel. INCOMING: Supply and fix on load Change over switch 63 Amp, 4 pole in sheet metal enclosure complete all as specified and directed. OUTGOING:- (a) Supply and fix Thermal Magnetic release, MCCB 63 Amps 415 Volts, 4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fitting items . (b) Refixing ,connecting of existing electric meter all as specified and directed. (c) 1 No. Digital Voltmeter 0-500 Volt with selector switch .(d) 1 No. Digital Ampere meter 0-100 A with selector switch and CT's.(e) LED Phase indicator lamp -01 Set (Set of three) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56759633
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 32.27 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Sluice Valve Ppr Pipe Lines, Gate Valve, Attending Day To Day W/S Complaints Cleaning Of Ug Sump Reservoir, Motor, Break Down Complaints, Repair To Roof Sheet False Ceiling Electrical Fittings Fixtures Of Dad, Ug Cable, Panel Board, Switch Gear Etc At Different Pockets/Locations Under Ge (I) Gos
Basic Detail
Tender No GE/GOS/TOK/85 OF 2026-27
Bidding Type Tender
Location
City Ganjam
State Odisha
Key Dates
Publish Date 30 Jul 2026
Submission Date 24 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 32.27 Lakhs
Tender Fee 500
EMD 65000
Exemption Not Available
Document List
7a9114db-5bc5-4947-8491-79be78b9da3a.html
BOQ_875612.xls
Tendernotice_1.pdf
tender_doc.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

7a9114db-5bc5-4947-8491-79be78b9da3a.html

xls

BOQ_875612.xls

pdf

Tendernotice_1.pdf

pdf

tender_doc.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders