Tender For Demolition And Re-Construction Of Ncs(E) Living In Accn At Af Station Chabua
Tender Value
5.70 Crore
Estimated cost
Bid Submission
03 Sep 2026
33 days left
EMD
6.10 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Demolition And Re-Construction Of Ncs(E) Living In Accn At Af Station Chabua
BOQ
| Sl. No. | Item Description |
| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: DEMOLITION AND RE-CONSTRUCTION OF NCs(E) LIVING IN ACCN AT AF STATION CHABUA Contract No: CE(AF)SZ/CHAB/ OF 2026-2027 File No: 88690/CHAB/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | SCHEDULE \\"A\\" Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:- |
| 3 | Construction of 01 Block of single accommodation for NCs(E) in (G+2) storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 4 | Construction of 01 Block of car shed for 11 Nos of cars for NCs(E) with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 5 | Construction of 01 Block of scooter shed for 24 Nos of scooter for NCs(E) with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 6 | Construction of garbage bin large as per TD drawings mentioned complete all as specified and as directed. |
| 7 | SCHEDULE \\"A\\" PART- II (SITE CLEARENCE AND AREA DEVELOPMENT) Details of prepriced Schedule is given in tender documents |
| 8 | SCHEDULE \\"A\\" PART- III(INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 9 | SCHEDULE \\"A\\" PART-IV (INTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 10 | SCHEDULE \\"A\\" PART- V (ROADS / PATHS / CULVERTS)Details of prepriced Schedule is given in tender documents. |
| 11 | SCHEDULE \\"A\\" PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents |
| 12 | SCHEDULE \\"A\\" PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 13 | SCHEDULE \\"A\\" PART- VIII(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 14 | SCHEDULE \\"A\\" PART- IX(EXTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 15 | SCHEDULE \\"A\\" PART- X(DEMOLITION OF BUILDING)Details of prepriced Schedule is given in tender documents. |
| 16 | SCHEDULE \\"A\\" PART- XI(SPECIAL WORK - MONKEY PROOFING FOR WATER TANK)Details of prepriced Schedule is given in tender documents. |
| 17 | SCHEDULE \\"A\\" PART -XII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 18 | INTERNAL ELECTRIFICATIONSupply and fixing LED rechargeable emergency inverter bulb 10/12 watt with, complete all as specified and directed. |
| 19 | Supply and fixing concealed MCCB distribution box, double door, vertical type, TPN, 415 V, 6 way IP 43 suitable for MCCB of 63 Amps, 4 Pole, 25 KA as incomer and MCB SP/TP as outgoing complete with suitable busbar, neutral link, earth link, complete all as specified and directed.Note:- (i) MCCB/ MCBs shall be measured and paid saperately.(ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate. |
| 20 | Supply and fixing MCB 230 Volts, 50 Hz, SPN, 32 Amps, 10 KA with \\"B\\" curve, complete all as specified and directed. |
| 21 | Supply and fixing MCB 230 Volts, 50 Hz, SPN, 16 Amps, 10 KA with \\"B\\" curve, complete all as specified and directed. |
| 22 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6mm thick electrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and directed.Note: Cost of GI wire earth lead of 4 mm dia from earth electrode to test point upto 7.5 metre shall deemed be included in the quoted rates. |
| 23 | INTERNAL WATER SUPPLYSupply and fixing pillar tap (hot & cold) of 15 mm bore, cast copper alloy with capstan heads chromium plated screwed down high pressure fancy type, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts long neck, screwed for iron pipe, complete all as specified and directed. |
| 24 | Supply and fixing 2 way bib taps of bore 15mm, chromium plated, cast copper alloy with crutch of butterfly handle, chromium plated with long shank and wall flange, cup, concealed type, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 25 | Supply and fixing angle cock of bore 15mm, cast copper alloy chromium plated with long shank and cup fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe, complete all as specified and directed. |
| 26 | Supply and fixing shower rose of bore 15mm, cast copper alloy chromium plated with long shank and cup fancy type of minimun length 300mm, complete all as specified and directed. |
| 27 | SEWAGE DISPOSALM&L for construction of conventional RCC Septic tank for 100 users designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter all as shown on drawing, complete all as specified and directed. |
| 28 | M&L for construction of Soakage wells excavation, in any type of soil, foundation in PCC (1:3:6), walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 6.0 M effective depth, complete all as specified and directed. |
| 29 | HOT WATER SUPPLYSupply and fixing electric water heater/Geyser, storage type rust proof PP (Thermoplastic) outer body with stainless steel inner tank and heating element up to 2 kw capacity 50 litre, BEE 5 Star rated with all accessories such as safety valve, thermostat, NRV, connection pipe etc including PVC connection pipe for Hot/cold water to existing water lines necessary fixing arrangement complete all as specified and directed. |
| 30 | EXTERNAL WATER SUPPLYM&L for cutting existing Steel tubing water supply line and insert 'TEE' for branch pipe of 90 mm dia including earth work, complete all as specified and directed. |
| 31 | M&L for construction of valve pit (brick masonry) of size 900x900x900mm (internal dimentions) depth reckoned from the top of PCC in foundation to top of MS cover with 3mm thick MS sheet cover including frame of angle Iron 40 x40 x6 mm frame work complete with locking arrangement and lifting handle including paintings of two coats of black synthetic enamel paints over a coat of red oxide primer etc. brick work in one brick thick wall in cement mortar (1:4), 15 mm thick plastering in cement mortar (1:4) (internally on all brick wall and external up to 15 cm below the ground level) and necessary excavation and earth work in any type soil, returning, filling in, disposal of surplus soil to a distance not exceeding 50m, 15 cm thick PCC (1:4:8) type D2 in PCC foundation projected by 15 cm all round from the outer face of brick wall PCC (1:2:4) type B1 in coping complete all as specified and as directed. |
| 32 | EXTERNAL ELECTRIC SUPPLYSupply, fabricate, install, test and commissioning LT Outdoor control panel of size 2000x1500x600 mm plateform mounted factory made totally enclosed weather proof, dust/vermin proof, openable from both front and rear side made out of 3.15 mm thick CRCA MS sheet, powder coated, CPRI approved and built upon 50x50x6 mm size angle iron frame work having front and rear hinged doors, lifting lugs(2 Nos) earthing strip at rear side bottom detachable gland plate complete with suitable size zinc plated and passivated nuts, bolt, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. Necessary foundation work as required at site and comprising following:BUS BAR(a) Electrolytic grade high conductivity TP&N solid copper bus bar rated 350 amps supported at required intervals sleeved with heat shrinkable PVC sleevings . The bars shall be colour coated at required intervals for identification-04 NosINDICATING DEVICES(a) LED indicating lamps for main supply indicating R,Y,B -01 Set of 3(b) Digital multi function meter-01 No(c) Current Transformer having ratio 400/5, 15 VA - 01 set of 3(d) AstroTime switch-01NoCONTROL(a) Supply and fixing MCCB of 4 pole of capacity 250 Amps with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting -01 Nos(incoming)(b) Supply and fixing MCCB of 4 pole of capacity 63 amps with breaking capacity of 25 KA with fixed thermal & fixed magnetic setting -02 Nos (outgoing) (01 for bldg and 01 Spare)(c) MCB SPN 32 amps -04 Nos (02 Nos for parking shed & 01 No for street light and 01 No Spare) |
| 33 | M&L for earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of Plate not less than 1.50 m below normal ground level connected to 25 x 4 mm thick GI strip (Earth Lead) and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4) type B1 Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc, complete all as specified and directed.Note: Cost of galvanised iron strip of size 25 x 4mm from earth electrode to test point upto 7.5 metre shall deemed be included in the quoted rates. |
| 34 | Supply and fixing 25 W LED post top lamp new generation , IP 65 energy saving, enviornmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaries with high power LEDs at light source, clear cover offers bright illumination including suitable size loop in loop out boxes & flexible 3 core 1.5 sqmm copper connecting cable from loop in loop out box to fitting etc, complete all as specified and directed. |
| 35 | Supply and fixing Cable Junction Box 130x180x77 mm in size, made out of thermoplastic sheet having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) and one no MCB SP 6 amps complete fixed on poles with flat aluminium clamps of size 20x3mm, nuts, bolts, washers etc. cable junction box, complete all as specified and directed. |
| 36 | M&L for street light bracket, bend to 120 degree angle, made out of 40 mm bore, galvanised iron, light grade tubing (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc. and two coats of synthetic enameled paint over a coat of red oxide primer, complete all as specified and directed. |
| 37 | DEMOLITION OF BUILDINGTaking down carefully copper/aluminium Sub main wiring of any size from existing surface/concealed conduit of any size and removing materials to store for keeping safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good to disturbed surfaces of wall, floor etc, complete all as specified and directed. |
| 38 | Note:- Schedule of credit (Sch 'A' Part- XVI) amount of Rs 4,72,037.00 shall be deducted from the total quoted amount of BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 33 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 35 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender