Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #56759573

Tender For Repair/ Maintenance To Porch Rolling Shutter, Garages In Arjan Vihar And Other Adjoining Areas Of Age B/R-Ii Including Repair / Replacement Of Unserviceable Earting, Mccb, Mcb, Db And Modular Type Electrical Fittings Including Sub Main Wir

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
40 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
5 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance To Porch Rolling Shutter, Garages In Arjan Vihar And Other Adjoining Areas Of Age B/R-Ii Including Repair / Replacement Of Unserviceable Earting, Mccb, Mcb, Db And Modular Type Electrical Fittings Including Sub Main Wiring And Allied E/M Work At Arjan Vihar Offrs Md Accn And Adjoining Area Under Ge (Central) Delhi Cantt-10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Aug-2026 BOQ BOQ 20-Aug-2026

BOQ

Name of Work:- REPAIR/ MAINT TO PORCH ROLLING SHUTTER, GARAGES IN ARJAN VIHAR AND OTHER ADJOINING AREAS OF AGE B/R-II INCLUDING REPAIR / REPLACEMENT OF UNSERVICEABLE EARTING, MCCB, MCB, DB AND MODULAR TYPE ELECTRICAL FITTINGS INCLUDING SUB MAIN WIRING AND ALLIED E/M WORK AT ARJAN VIHAR OFFRS MD ACCN AND ADJOINING AREA UNDER GE (CENTRAL) DELHI CANTT-10
Sl. No. Item Description
1Roughening surfaces of old concrete floor by picking, sweeping clean andwashing down with water to removedust, etc
2M &L for Brushing neat cement slurry with 3 Kg of cement per square metre complete all as specified and directed .
3M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as spd & directed.
4M&L for rendering 10mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound at the rate of 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately.
5M & L for applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on top of roof surface in multiple coats @2 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and other coats needs to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. When the 2nd coat is wet, the Smartcare EPDM tape (at corners and edges)shall be inserted between second and third coat to secure corners & edges, let the material ooze out from the tapes corner. Same treatment of Smartcare Dampproof shall be continued to the parapet walls to better envelope the whole area. The coating shall be terminated carefully to the other side of the parapet wall. NOTE:- The quoated rate should also incl chajja portion also of G+5 storey bldgs.
6M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints
7M & L Cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops etc including weathering slightly rounded or chamfered edges, finished even and smooth without using extra cement complete all as specified.
8M&L cleaning surface and applying two coats of aluminium paint on roof or vertical surfaces complete all as specified and directed.
9S & F in repair of steel rolling shutters without ball bearing, as specified incl top cover anchoring rod hasp & staple and one shop coat of primer before erected in position as directed complete manual type thickness of lath 1.25mm.
10S & F in repairs roller ball bearing (ISI marked) for 32/40 mm dia pipe shaft complete all as specified and as directed by Engineer-in-charge.
11M&L for repairing/welding of rolling shutter of any size by oiling & greasing and of whole rolling shutter incl all fittings and fixtures of shutter complete all as specified and directed.
12M&L for cement concrete (1: 2 :4) type B-O (using 12.5mm graded stone aggregate) 25mm thick in floor complete all as specified.
13M & L machine cut Kota stone 20 to 25 mm thick over 15 mm thick 1:6 cement screed base laid and jointed with grey cement slurry mixed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete up to deserid finish as directed.
14Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level).complete all as specified.
15Taking Down cement plaster or lime of any description including racking and joint hacking for key scrubing down with water etc complete all as specified.
16M & L for 10 mm thick rendering in CM (1:6) on wall of fair faces brick & concrete surfaces finished even and smooth without using extra cement complete all as specified.
17M & L for 5 mm thick rendering in CM (1:3) on Ceiling of fair faces brick & concrete surfaces finished even and smooth without using extra cement complete all as specified.
18M&L rendering 10 mm thick in CM 1:4 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed . Note :-work shall be executed upto G+5 storey bldg with necessary steel scaffolding as required.
19Material & Labour for preparation of new plastered surfaces of walls applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
20M & L three coats of white wash on newly surface on ceiling including all preparation complete all as specified & directed
21M&L two coats of white wash of newly plastered wall surfaces including preparation of surface complete.
22M&L preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots etc and applying one coat of white wash on old decorated plastered or unplastered surfaces of walls.
23Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar
24M&L for machine cut kota stone slab 20-25 mm thick as in riser/skirting laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including, grinding, rubbing and polishing over 10 mm thick bedding in cement mortar (1:4) complete all as specified and directed.
25M&L for 16-18mm thick Udaipur green marble laid over and including 15mm thick screed bed in CM 1: 6 as in floors /treads/risers of steps in one piece including cutting, jointing, moulding and granite polishing, laid in designed complete all as specited and directed
26M & L for Powder coated (minimum thickness of powder coating 50 micron) aluminium window & Ventilator shutters side hung type aluminium section weighing 0.55 kg/m including joining cleats, glazing clips, rubber neoprene packing, necessary powder coated hardware i.e.. handles, barrel tower bolts, hinges etc, powder coated aluminium snap beading, screws etc. complete all as specified and directed Note : Panel filling i.e.. glass, fibre sheet, board, wire mesh etc. included in the rate.
27S & F in repair Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified
28Dismantling asbestos cement corrugated or semi corrugated sheet in roof coverings complete all as directed.
29S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed
30M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
31M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed.
32M & L for providing precast reinforced cement concrete jallies 40 mm thick including all mouldings type B-0 1:2:4(12.5mm graded stone aggreagte) set in cement mortar 1:4, complete all as specified.
33M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
34Taking down existing chowkats or frames of any description and in any position exceeding 1.5 sqm n-exc 4.0 sqm each with shutter (w/o taking off shutter from the frames) complete all as specified and directed.
35M&L cleaning surface and applying two coats of aluminium paint on roof or vertical surfaces complete all as specified and directed.
36M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed.
37Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
38M & L for Point wiring complete with 1.5 sqmm single core PVC unsheathed insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new/existing and metalic/non-metalic rigid PVC conduit medium grade ISI Marked not less than 20 mm dia including all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc by cutting chases and including provision of 1.5 sqmm PVC unsheathed insulated copper cable FRLS as earth continuty, suitable fabricated branded modular metal flush box / M S steel terminal boxes duly make embossed, concealed in wall and making the adjacent surfaces smooth through POP work & painting as per site requirement incl provision of modular inner and outer cover plates with laminated top sheet cover for housing switches , socket out let and fan regulators etc concealed in walls with suitable , all as specified and as directed for the followings:-
39One light/ fan point controlled by one way switch
40One bell point controlled by one bell push
41One light point controlled by two Nos two way switches
42One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
43One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
44All as per item No 38 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete.
45Supply & fixing in replacement of white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
46Supply & fixing in replacement of white cover plate with frame 3/4 module complete all as specified and directed by Engineer in charge.
47Supply & fixing in replacement of white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
48Supply & fixing in replacement of white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
49M&L switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified.
50M&L Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified.
51M&L switch modular type 6 amp SP two way, 1 module complete all as specified.
52M&L Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete.
53M&L switch Modular type 16 Amps 1Way, 1 module with modular plat, 230V AC complete.
54M&L Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete.
55M&L modular stepped type electronic fan regulator 120W, 1/2 module complete .
56M&L Switch piano flush button type single pole one way 6 Amps complete all as specified.
57M&L switch piano flush button type single pole 16 Amps complete all as specified.
58M&L socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified.
59M&L socket outlet 6 Amp flush button type complete all as specified.
60M&L regulator electronic 5 steps type suitable for 1200/1400 mm sweep 230 volts..
61M&L bell electric (dingdong) 230 volt, SP all complete all as specified and directed .
62M&L insulated body, angle/batten holder with back plate complete.
63S&F ceiling rose surface PVC type with three terminals complete all as specified and directed .
64M&L sheet metal enclosure, modular/non modular as per site requirment single pole and neutral with a two pin and earth plug and socket 230 Volts grade complete with one single pole MCB 'C' series 20 A capacity complete all as specified and directed.
65S & F LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with, Power Factor > 0.9, colour temperature - 6500K, surge protection 2.5KV in CM, meets LED IS specifications, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
66S & F LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, > 1000 systems lumen outputwith lifetime of 25000 burning hours with, Power Factor > 0.9, colour temperature - 6500K, surge protection 2.5KV in CM, meets LED IS specifications, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
67S & F LED 9/10 watts bulkhead fitting with non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours , Power Factor >0.9, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, , Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
68S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge . Make : Philips / Havells / Bajaj
69S & F surface ceiling mounted, LED down light fitting 12 watts , system efficacy at luminary level ≥ 70 Lumens/watt, 25000 burning hours, 6500K color temperature with , Power Factor > 0.90, with multi stage high voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. .
70S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified. Please Enable Macros to View BoQ information
71S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56759573
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 20-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance To Porch Rolling Shutter, Garages In Arjan Vihar And Other Adjoining Areas Of Age B/R-Ii Including Repair / Replacement Of Unserviceable Earting, Mccb, Mcb, Db And Modular Type Electrical Fittings Including Sub Main Wiring And Allied E/M Work At Arjan Vihar Offrs Md Accn And Adjoining Area Under Ge (Central) Delhi Cantt-10
Basic Detail
Tender No GE/TOKEN-57/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 06 Aug 2026
Submission Date 20 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_875830.xls
e11a9c3d-7d2f-497d-aac3-1921fdb2f5c6.html
Tendernotice_1.pdf
tenderpage.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Aug 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_875830.xls

html

e11a9c3d-7d2f-497d-aac3-1921fdb2f5c6.html

pdf

Tendernotice_1.pdf

pdf

tenderpage.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders