Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #56759570

Tender For Repair/Replacement To External Water Supply Lines And Connecting Works At Nabha Under Ge (S) Patiala.

Issued by Statutory Bodies & Commissions/Committees · Patiala, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Aug 2026
12 days left
EMD
36000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement To External Water Supply Lines And Connecting Works At Nabha Under Ge (S) Patiala.

BOQ

Name of Work:- REPAIR/REPLACEMENT TO EXTERNAL WATER SUPPLY LINES AND CONNECTING WORKS AT NABHA UNDER GE (S) PATIALA.
Sl. No. Item Description
1'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
2Excavation in trenches in soft soil not exceeding 1.50 metre wide & not exceeding 1.50 metre deep for foundation ,for laying of water supply pipe line in trenches and getting out including dressing/trimming sides and levelling, grading and ramming of bottom of excavation complete all as specified and directed.
3Returning, filling in, including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, excavated soil in trenches after pipes have been laid and tested, complete all as specified and directed.
4Removing excavated surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
5Cutting of road /PCC path upto the depth of pipe & making good the disturbed surface with PCC 1:2:4 (20 mm aggregate) 15 cm thick using extra cement including earth work complete all as specified and directed
6Taking up or down old rusted steel water GI tubing, 80 mm bore including fitting connections complete all as specified and directed.Note: (i) Excavation and earth work shall be measured and paid separately.
7All as per serial item no 6 but 50 mm bore, complete all as specified and directed.
8All as per serial item no 6 but 40 mm bore, complete all as specified and directed.
9All as per serial item no 6 but 25 mm bore, complete all as specified and directed.
10All as per serial item no 6 but 20 mm bore, complete all as specified and directed.
11All as per serial item no 6 but 15 mm bore, complete all as specified and directed.
12S&F Steel water tubing, 80 mm bore, medium grade, galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
13All as per serial item no 12 but 50 mm bore, complete all as specified and directed.
14All as per serial item no 12 but 40 mm bore, complete all as specified and directed.
15All as per serial item no 12 but 25 mm bore, complete all as specified and directed.
16All as per serial item no 12 but 20 mm bore, complete all as specified and directed.
17All as per serial item no 12 but 15 mm bore, complete all as specified and directed.
18Fixing/laying only water tubing 80mm bore including cleaning, threading as required to the old pipe for reuse, with and including new fittings & fixtures to make it functional complete all as specified and directed.Note: (a) Excavation, earth work, joints, threading & CI specials shall be measured and paid separately.(b) Old serviceable tubing as retreived under item No.6 shall be re-used under this item.
19All as per serial item no. 18 but 50mm bore, complete all as specified and directed.Note : Old serviceable tubing as retreived under item No.7 shall be re-used under this item.
20All as per serial item no.18 but 40mm bore, complete all as specified and directed.Note : Old serviceable tubing as retreived under item No.8 shall be re-used under this item.
21All as per serial item no. 18 but 25mm bore complete all as specified and directed.Note : Old serviceable tubing as retreived under item No.9 shall be re-used under this item.
22All as per serial item no. 18 but 20mm bore complete all as specified and directed.Note : Old serviceable tubing as retreived under item No.10 shall be re-used under this item.
23All as per serial item no. 18 but 15mm bore complete all as specified and directed.Note : Old serviceable tubing as retreived under item No.11 shall be re-used under this item.
24Supply testing and commissioning of gun metal glove or gate valve heavy duty ISI marked class-1 with iron wheel head, screwed both ends for iron pipe of following bore complete fixed as in repairs and complete all as specified and directed.Note: In case short length of GI tubing/nipple is required to fix the valve, it shall be measured & paid under item No. 13 to 17 respectively here-in-before.
25Pipe of 15mm bore complete all as specified and directed.
26Pipe of 20mm bore complete all as specified and directed.
27Pipe of 25mm bore complete all as specified and directed.
28Pipe of 40mm bore complete all as specified and directed.
29Pipe of 50mm bore complete all as specified and directed.
30Taking up/out old rusted GI/CI/Ductile Iron water mains including all fittings with spigot and socketed ends or flanged ends including burning out lead joints or dismantling flanged joints for pipe of following bore complete all as specified and directed.Note: (i) Excavation and earth work shall be measured and paid separately.
31Pipe of 80mm bore
32Pipe of 100mm bore
33Pipe of 150mm bore
34S&F Ductile iron water pipes class K-7 conforming to IS-8329, in any length including jointing with & including push on rubber tyton joints, as in trenches of following bore in new or old locations complete all as specified and directed of following sizes.Note: Excavation, earth work & DI specials shall be measured and paid separately. However, the rate of Rubber tyton joints shall be included in the unit rate quoted
35Pipe of 80mm bore
36Pipe of 100mm bore
37Pipe of 150mm bore
38Laying, jointing and testing serviceable DI pipes as mantioned below with & including flanged end or spigot and socketed ends as retrieved vide item No. 26 here-in-before in any length including cleaning, cutting for reducing length as required, jointing as in trenches for following bore in new or old locations complete all as specified and directed.Note:Excavation, earth work, joints, threading & CI specials shall be measured and paid separately
39Pipe of 80mm bore
40Pipe of 100mm bore
41Pipe of 150mm bore
42S&F ductile iron fittings of size upto 100/150 mm bore for spigot and socketed pipes e.g. Bends (any type, radius and angle), Tapers any type (Straight, end, increasing, decreasing or double socket etc), Tee pieces single branch, 'Y' junctions double branches, crosses (all sockets or socket and spigot) collars caps and plugs conforming to complete all as specified and directed.Note: Excavation, earth work & joints shall be measured and paid separately
43M&L for Cutting existing CI/DI pipe of following bore of any description for insertion of fittings and setting the pipe in proper alignment complete all as specified and directed.Note: Excavation earth work and fittings shall be measured and separately
44Pipe of 80 mm bore
45Pipe of 100 mm bore
46Pipe of 150 mm bore
47M&L for Construction of brick masonary valve pit of size 90 x 90 x90 cm (Internal dimension) incl necessary earth work, PCC foundation 1:3:6 a type C-1 and MS sheet 3 mm thick cover with angle iron frame 40 x 40 x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including 15mm plaster in cemnet motor 1:6 complete all as specified directed.
48All as per serial item No. 30 but pit size 60x60x90, complete all as specified and directed.
49S&F in replacement, Cast iron sluice valve, 150mm dia conformig to IS - 14846, PN 1.6, clockwise dosing with flanged ends and iron wheel with and including necessary joints by means of bolts, nuts washers and rubber gaskets complete all as specified and directed.
50All as per serial item No 32 but of 100 mm dia complete all as specified and directed.
51All as per serial item No 32 but of 80 mm dia complete all as specified and directed.
52Repair to sluice valve installed at existing line of 80/100/150 mm bore by opening up, necessary repair comprising replacement of glands, gland packing, gaskets, facing the gate & valve seat, replacement of nut bolts, re-assembling, spindle and fixing in position & testing complete all as directed.Note: -(i) Necessary arrangements for regulating the water supply in line for the purpose of repair shall be made by contractor at his own expenses.
53Taking out unserviceable wheel shaft of cast iron sluice valve from pit /column pipe of 150 /100/80 mm dia & carrying to the workshop for cutting, threading, grinding etc & refixing the same after repair complete all as specified & directed.
54M&L for drilling and tapping of GI/ CI/DI water line for branch connection of 15 mm to 50mm pipe with clamp & connected accessories complete all as specified & directed.
55M&L for cleaning and disinfection of entire internal surfaces of chamber of RCC overhead reservoir both compartment of capacity One Lakh gallon at 70 to 80 ft staging at Nabha including all required T&P and manpower comprising of the following processes.(a) Draining out water and evacuation of internal surfaces including floor and cleaning with mechanical pressure machine by applying solution of H2 02 (Hydrogen per Oxide) in the ratio of 1: 100 (1 LT of H202 and 100 Ltr of water).(b) Dislodging the dirt layers with high speed water jet including scrapping the surface with wire brush and draining out the sludge water.(c) Cleaning the internal surfaces complete with Mechanical Scrubber and washing the surfaces with high-pressure water jet.(d) Filling the chambers with clear water and washing out prior to reuse after complete process.(e) Writing on the surface of tank date of cleaning as specified and as directed
56Taking down old unserviceable non return valve of 150 mm dia from existing position and supply & fixing cast Iron non return valve of 150 mm dia conforming to IS 14846 with flanged ends including necessary joints by means of bolts and nuts washers and rubber gasket complete all as specified & directed.
57Supply only calcium hypoclorite 65% to 70% chlorine content in granuals form calcium based granular chlorination chemical all as specified and directed.Note :- (i) Hogh strength calcium based granular chlorination chemical to packed in plastic drum of 45 Kgs each (ii) The brand and make of thr chlorination chemical must be stated and certifcate of Hygiene & Public Health (Govt of India) conforming compliance to all the above specification technical strength, stability, health, safety and operational point of view as well as the fact this product is used for water supply installations.
58M&L for detecting the leakage from underground CI/DI pipe 150 mm bore and rectifying the leakage by burrning out existing lead and redoing the joint by adding extra lead if required complete all as specified & directed.
59All as above item No. 41 but for CI/DI pipe 100 mm bore, complete all as specified & directed.
60All as above item No. 41 but for CI/DI pipe 80 mm bore complete all as specified & directed.
61M&L for detecting the leakage from underground GI pipe 15 to 50 mm bore and rectifying the leakage by cutting/threading/adding extra length (up to 1 RM only) of pipe if required complete all as specified & directed.
62M&L for painting steel or iron surface of any description wih two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
63M&L in replacement of Old Unsv MS sheet pit cover of 3.15 mm thick along with angle iron frame,locking arrangements and necessay civil works including taking up old iron cover and painting with synthetic enamal paint complete all as specified and directed.
64Supply connecting and testing and comissioning complete in replacement of existing unserviceable electric cable PVC insulated and PVC sheathed water proof 3 phase 3 core AC 1100 volts grade 25 sqmm multistarnded flat copper conductor suitable for submersible pump including making connection to pump set as well as to control panel complete including taking out old cable all as directed. Please Enable Macros to View BoQ information
65Supply connecting and testing and comissioning complete in replacement of existing unserviceable electric cable PVC insulated and PVC sheathed water proof 3 phase 3 core AC 1100 volts grade 25 sqmm multistarnded flat copper conductor suitable for submersible pump including making connection to pump set as well as to control panel complete including taking out old cable all as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56759570
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 20-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement To External Water Supply Lines And Connecting Works At Nabha Under Ge (S) Patiala.
Basic Detail
Tender No GE(S)/PAT/T-40/2026-27
Bidding Type Tender
Location
City Patiala
State Punjab
Key Dates
Publish Date 30 Jul 2026
Submission Date 20 Aug 2026
Open Date 22 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 36000
Exemption Available
Document List
T-40.pdf
Tendernotice_1.pdf
BOQ_875827.xls
f76ddfc2-27f3-48aa-8d7d-4c02c073334f.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

T-40.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_875827.xls

html

f76ddfc2-27f3-48aa-8d7d-4c02c073334f.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders