Tender For Construction Of 50 Kld Capacity Stp And 10 Kld Etp In Esi Hospital Bhopal
Tender Value
1.02 Crore
Estimated cost
Bid Submission
10 Aug 2026
4 days left
EMD
1.02 Lakhs
Bank guarantee accepted
Document Fee
2425
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 50 Kld Capacity Stp And 10 Kld Etp In Esi Hospital Bhopal
BOQ
| Sl. No. | Item Description |
| 1 | Eatth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of sutplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exteeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 4 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, wateting, etc. and disposing of sUJplus excavated soil as directed, within a lead of 50 111 : |
| 5 | All kinds of soil |
| 6 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mmdia |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutte1ing - All work up to plinth level : |
| 8 | 1:5:IO(I cement : 5 coarse sand (zone-iii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size de1ived from natural sources) |
| 9 | Extt-a for providing and mixing water proofing matciial in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centeting, shutteiing, finishing and reinforcement - All work up to plinth level : |
| 12 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement |
| 14 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 17 | Foundations, footings, bases of columns, etc. for massconcrete |
| 18 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 19 | Suspended floors, roofs, landings, balconies and accessplatform |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 21 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 22 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 23 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 25 | Hot finished welded type tubes |
| 26 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 27 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 28 | In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete |
| 29 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 30 | Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 31 | Ridges plain (500 - 600mm) |
| 32 | Flashings/ Aprons.( Upto 600 mm) |
| 33 | 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of single or half brick wall. |
| 34 | Neat cement punning. |
| 35 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 36 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 38 | 25 mm nominal dia Pipes |
| 39 | 50 mm nominal dia Pipes |
| 40 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 41 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 42 | 110 mm diameter |
| 43 | Providing and fixing square-mouth S.W. gully trap class SP-1complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 44 | 150 x 100 mm size P type |
| 45 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 46 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps |
| 47 | 150 mm diameter |
| 48 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 49 | 250 mm dia. R.C.C. pipe |
| 50 | Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 51 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 52 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 53 | Extra for depth for manholes : |
| 54 | Size 90x80 cm |
| 55 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 56 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete |
| 57 | For pipes 100 to 250 mm diameter |
| 58 | Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-charge: |
| 59 | Rectangular manhole 90x80 cm and 45 cm deep |
| 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge |
| 61 | 40 MM DIA |
| 62 | 50 MM DIA |
| 63 | Providing and Fixing CPVC Ball valve of approved quality complete as per the direction of engineer encharge |
| 64 | 50 mm nominal dia |
| 65 | Providing and Fixing CPVC Union in CPVC pipe including cutting and jointing of pipe & fitting with one step one step CPVC solvent cement and testing of joints complete as per direction of Engineer Incharge |
| 66 | Unions 50 mm OD |
| 67 | Supply and filling of Kopra of Approved quality in trenches plinth side of foundation etc in layer not exceeding 20 cm in depth consolidating each lyer by ramming and watering for all lead and lift all complete as per direction of engineer inchrge. |
| 68 | Consent to Stablishment along with NOC from Polution control Board. |
| 69 | Architecture Consultancy Fee |
| 70 | Bar Screen for STP and ETP |
| 71 | Providing Stainless Steel (SS304) Perforated Fine Bar Screen .The hole size of screen shall be for soild handling capacity of 8-10mm sewage flow. |
| 72 | Size : DDE |
| 73 | MOC : SS-304 |
| 74 | Qty - 02 Nos (for STP and ETP) |
| 75 | Application - To trap the larger and small particles/ debries upto 8-10mm size from the effluent. |
| 76 | Note - Bar Screen Clean Manually |
| 77 | Raw Sewage Transfer Pump for STP |
| 78 | Providing non clogging submersible type Wastewater lifting pump in single phase having CI casing & CI impeller complete with and foundation bolts all accessories, motor of required capacity. Pressure gauge on delivery line with isolation cock, level controller to control the level of sump automatically. Pumps shall have following duty: Three Phase. |
| 79 | Application - To transfer the sewage from Equalization/ Collection tank to Aeration (MBBR-1) tank |
| 80 | Quantity - 02 Nos (1W + 1S) |
| 81 | Type - Submersibe Pump |
| 82 | Flow Rate : Upto 3.5 M3/Hr |
| 83 | Head : 8-10 mtr |
| 84 | Solid handling : 18 MM |
| 85 | RPM- 2900 |
| 86 | Make - CRI/ Kriloskar/ Lubi |
| 87 | Recirculation/ Sludge Transfer Pump for STP |
| 88 | Providing non clogging monoblock type Wastewater lifting pump in single phase having CI casing & CI impeller complete with and foundation bolts all accessories, motor of required capacity. Pressure gauge on delivery line with isolation cock, level controller to control the level of sump automatically. Pumps shall have following duty: Three Phase. |
| 89 | Application- To transfer the slurry from bottom of tube settler tank to the Sludge Holding Tank and also recirculate the slurry to MBBR 1 Tank to maintain MLSS. |
| 90 | Quantity - 02 Nos (1W + 1S) |
| 91 | Type - Selfpriming/ Monobloc |
| 92 | Flow Rate : Upto 3.5 M3/Hr |
| 93 | Head : 10-12 mtr |
| 94 | RPM- 2700 |
| 95 | Solid handling : 5 MM |
| 96 | Make - CRI/ Kriloskar/ Lubi |
| 97 | Effluent Transfer Pump for ETP |
| 98 | Providing non clogging monoblock type Wastewater lifting pump in single phase having CI casing & CI impeller complete with and foundation bolts all accessories, motor of required capacity. pressure gauge on delivery line with isolation cock, level controller to control the level of sump automatically. Pumps shall have following duty: Three Phase. |
| 99 | Application - To transfer the effluent from Equalization/ Collection tank to Flash Mixer Tank |
| 100 | Quantity - 02 Nos (1W + 1S) |
| 101 | Type - Selfpriming/ Monobloc |
| 102 | Flow Rate : Upto 1 M3/Hr |
| 103 | Head : 8-10 mtr |
| 104 | RPM- 2700 |
| 105 | Solid handling : 5 MM |
| 106 | Make - CRI/ Kriloskar/ Lubi |
| 107 | Chemical Dosing System for ETP Plant |
| 108 | Note:- The Agitation in Chemical Dosing tanks/ Flash Mixer/ Flocculation Tank through Air Blower. |
| 109 | Lime Dosing System- |
| 110 | Providing and fixing of dosing system consisting one HDPE tank of 100 liters capacity .The Dosing of Chemical through Gravity with complete UPVC piping, valves, strainers & fittings. |
| 111 | Application - Dosing of Lime at Flash Mixer Tank to balance the pH of effluent during reaction. |
| 112 | Dosing Tank MOC - HDPE |
| 113 | Make of HDPE tank - Plasto/ Ganga/ Sheetal |
| 114 | Coagulant Dosing System |
| 115 | Providing and fixing of dosing system consisting one HDPE tank of 100 liters capacity .The Dosing of Chemical through Gravity with complete UPVC piping, valves, strainers & fittings. |
| 116 | Application - Dosing of coagulant like Alum/ PAC/ Ferrous Sulphate/ etc to the Flash Mixer tank to aggregate the impurities and suspended soilds and precipitate it. |
| 117 | Dosing Tank MOC - HDPE |
| 118 | Make of HDPE tank - Plasto/ Ganga/ Sheetal |
| 119 | Focculant Dosing System |
| 120 | Providing and fixing of dosing system consisting one HDPE tank of 100 liters capacity .The Dosing of Chemical through Gravity with complete UPVC piping, valves, strainers & fittings. |
| 121 | Application - Dosing of Flocculant like polyelectrolyte to the Flocculation tank to aggregate the flocs into larger/ heavier flocs. |
| 122 | Dosing Tank MOC - HDPE |
| 123 | Make of HDPE tank - Plasto/ Ganga/ Sheetal |
| 124 | Complete Air Diffusion System including Air Blower (Common for both STP and ETP Plant |
| 125 | Air Blower for both STP and ETP |
| 126 | Twin Lobe Rotary type Air Blowers capable of delivering of free air driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP, for 415 ± 10% volts, phase, 50 cycles A/C supply. Including foundation and foundation bolts work. Single Phase. |
| 127 | Application: For suplying of air to Equalisation/ Aeration Tank/ Flash Mixer/ Flocculation Tank/ Chemical Dosing Tanks. |
| 128 | Quantity - 02 Nos (1W + 1S) |
| 129 | Pressure - 0.5kg/cm2 |
| 130 | Capacity - Upto 130 m3/hr |
| 131 | Make- Akash/Beta/Airvac |
| 132 | Air Dispersion System |
| 133 | Non Clog Tubular Type Air Dispersion System capable of handling 3-5 cfm of Air with Oxygen Transfer efficiency of 3-4% per meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from platform at the top. (fine bubble membrane diffusers) |
| 134 | Application : Air dispersion system shall be provided to transfer the air to Equalization tank/ Aeration tank/ Flash Mixer/ Flocculation Tank/ Chemical Dosing Tanks. |
| 135 | Course Bubble Diffusers |
| 136 | Diameter-150mm |
| 137 | Type-Disc |
| 138 | Moc-EPDM |
| 139 | Application- To mix sewage in equal proportion (Homozonised Mixture) |
| 140 | For Equalization Tank (Course Bubble Diffusers) |
| 141 | For Flash Mixer/ Flocculation tanks (Course Bubble Diffusers) |
| 142 | For Sludge Holding Tank (Course Bubble Diffusers) |
| 143 | Fine Bubble Diffusers - For Moving Bed Bio-media Reactor (MBBR Tank) |
| 144 | Diameter-63mm |
| 145 | Length- 610mm |
| 146 | Type- Cylinderical shape |
| 147 | Application- Transfer the Oxygen/ Air to aeration tank to kill mocrobs, reduce BOD level and also mentain MLSS level. |
| 148 | Moc-EPDM/Cilicon |
| 149 | Media |
| 150 | MBBR Media for STP |
| 151 | Providing MBBR/ FAB media to be installed in MBBR reactor alongwith suitable sludge removal arrangement either by sludge transfer pump or air lifting pumps. |
| 152 | MOC-PVC |
| 153 | Type- Bio Pack Media |
| 154 | Application- To enhance surface area and Maintain MLSS level |
| 155 | Tube Deck Media for both STP and ETP |
| 156 | Providing suitable PVC tube deck settling media to be installed in Secondary Tube Setller tank alongwith suitable sludge removal arrangement either by pumps or air lifting pumps |
| 157 | Application- To separate liquid and solid part in tube Settler tank |
| 158 | Purpose: For Better Settlement of Sludge |
| 159 | Length- 750 mm |
| 160 | Type- Hexagonal chevron |
| 161 | MOC- PVC |
| 162 | Filtration Unit Common for both STP and ETP Plant |
| 163 | Filter Feed Pump |
| 164 | Providing Horizontal centrifugal non clog water pumps with CI casing and CI Impeller along with motor, pressure gauge with isolation valve, NRV on delivery line, stainer (with by-pass) at suction. Mechanical seal, suitable vibration elimination pads of approved design, for the pump. The pump shall be suitable for 415±10% volts Three phase AC supply. Including foundation bolts |
| 165 | Quantity - 02 Nos (1W + 1S) |
| 166 | Capacity : Upto 4 M3/Hr |
| 167 | Type of Pump : Monoblock |
| 168 | Head :25-30Mtr |
| 169 | Make - CRI/ Kriloskar/ Lubi |
| 170 | Multigrade Sand Filter Unit (MGF) |
| 171 | Vertical Filter with adequate dirt holding capacity (suitable for 3 Kg/Sq cm operating pressure). Vertical filter As per manufacturer's specifications complete with initial charge filter media including. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping (UPVC/ SCH-40) and Multiport valves designed |
| 172 | To remove the total suspended solids, dirt, iron and reduce silt density index which can foul the membranes |
| 173 | Quantity - 01 Set |
| 174 | MOC - FRP (Poly Glass) |
| 175 | Dia - 21 inch |
| 176 | HOS - 62 inch |
| 177 | Type - Top/ Bottom Mounted |
| 178 | Operationals- Manual |
| 179 | Media - Sand Media, Pebble, Gravel |
| 180 | Media Quantity - As per required |
| 181 | MPV Make - Inititive/ Midas |
| 182 | Activated Carbon Filter Unit (ACF) |
| 183 | Vertical Filter with adequate dirt holding capacity (suitable for 3 Kg/Sq cm operating pressure). Vertical filter As per manufacturer's specifications complete with initial charge filter media including. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping (UPVC/ SCH-40) and Multiport valves designed |
| 184 | Application : To remove the Color and Odour. |
| 185 | Quantity - 01 Set |
| 186 | MOC - FRP (Poly Glass) |
| 187 | Dia - 21 inch |
| 188 | HOS - 62 inch |
| 189 | Type - Top/ Bottom Mounted |
| 190 | Operationals- Manual |
| 191 | Media - Activated Carbon, Pebble, Gravel |
| 192 | Media Quantity - As per required |
| 193 | MPV Make - Inititive/ Midas |
| 194 | Hypo Dosing System for disinfection of treated water. |
| 195 | Providing Hypo/Chlorine Dosing System consist 100 ltrs HDPE tank with 0-6 lph electronic metering pump. |
| 196 | Cap- 0- 6LPH |
| 197 | Application- To kill Bacteria, viruses etc (As a disinfectant) |
| 198 | Dosing Tank Make- Plasto/Ganga |
| 199 | Dosing Pump Make- E Dose/Equil |
| 200 | Note - Fresh water line upto dosing tank (in client scope) |
| 201 | Sludge Dewatering System (Common for STP and ETP Plant) |
| 202 | Poly Dosing System |
| 203 | Providing polyelectrolyte Dosing System consist 100 ltrs HDPE tank with 0-6 lph electronic metering pump. |
| 204 | Capacity- 0-6 LPH @ 2.5kg pressure |
| 205 | Application- For Making Sludge thick. |
| 206 | Dosing Tank Make- Plasto/Ganga |
| 207 | Note - Fresh water line upto dosing tank (in client scope) |
| 208 | Filter Press Feed Pump/Screw Pump |
| 209 | Providing Positive Displacement type Screw Pump or Sludge Feed Pump for Sludge feed from Sludge Holding tank to Filter press, V belt motor derive. |
| 210 | Flow rate - Upto 1 m3/hr |
| 211 | Head - 30-35 Meter |
| 212 | MOC-CI |
| 213 | Application- feed sludge from sludge holding tank to filter press unit |
| 214 | Make- Miniflow/ Eq |
| 215 | Filter Press Machine- |
| 216 | Providing Filter Press for suitable capacity of STP, including filter press of Suitable Capacity with CI frame, PP plates complete with filter cloth complete with interconnecting piping, taps and drainage collector pipe system. |
| 217 | No. of Plates- 17 Nos |
| 218 | Plate Size - 18 inch |
| 219 | MOC- MS |
| 220 | Type- manual operation |
| 221 | Application- To make dry sludge |
| 222 | Instrumentation common for both STP and ETP Plant |
| 223 | Flow Meter (Digital) |
| 224 | Providing & fixing of Flow Meter mounted at final treated water line to record the outlet flow. |
| 225 | Size- 1 inch |
| 226 | Type- Digital |
| 227 | Application- To measure final treated water. |
| 228 | Make- Aster/ Eq |
| 229 | Float Sensor |
| 230 | Providing & fixing Electronic Type Level Indicator and Controller for Automatic Operation of the complete system with high/low level alarm complete with auxillary NO/NC contacts. |
| 231 | For required tanks |
| 232 | Application : For required tanks |
| 233 | Make :Aster/ Eq |
| 234 | Pressure Guages |
| 235 | Providing and fixing Pressure Guages in STP System to making the installation complete. |
| 236 | MOC-SS |
| 237 | Range- 0-7kg/cm2 |
| 238 | Size- 1 inch |
| 239 | Application- To calaculate Pressure for each unit in STP & ETP system |
| 240 | Make- Hguru/ Eq |
| 241 | Piping & Fitting for both STP and ETP Plant |
| 242 | MSEP Piping & Fitting for Non Submerged Air Blower Line (for STP) |
| 243 | MSEP Header with piping and fitting in MS is completed with fittings such as tees, Butterfly valves, crosses, sockets, elbows & making good. |
| 244 | Size of header - 3/ 4inch |
| 245 | Size of MS Pipe- 1/ 1.5/ 2/ 2.5 inch |
| 246 | MOC- MS |
| 247 | Application- For Maintaining air Pressure after blowing Air in UPVC Pipelines to Equalization tank, Aeration Tank, Sludge Holding tank |
| 248 | Make MS - Jindal/tata |
| 249 | UPVC Pipe & Fitting (for STP and ETP) |
| 250 | Providing and fixing all piping (as described below) and isolation control valves for making the system complete. |
| 251 | MS Header for ETP: MS Header for airblower |
| 252 | uPVC : Submerged air piping |
| 253 | uPVC : Air blower line after MS Header (Non submerged) |
| 254 | UPVC Pipe : Interconnecting pipe line after delivery header of pump/ filter |
| 255 | UPVC/PVC Pipeng : Pumped sewage (submerged) & tank overflow pipe line |
| 256 | Make- UPVC - Ajay/ Prince |
| 257 | Centralized Electrical Control Panel (Common for both STP and ETP Plant) |
| 258 | Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing and Commissioning of Motor Control Centre shall be Fabricated out of 16 Gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Galvanised hardware with zinc passivation shall be used in fabrication of panels. |
| 259 | Incoming (1 no.) |
| 260 | 32 Amps TPN Load break Isolator with the following accessories: |
| 261 | A set of 0-240 volts 96 x 96 mm square digital electronic voltmeter with selector switch shall be protected by suitable MPCBs |
| 262 | A set of 0-32 amps 96 x 96 mm square digital electronic ammeter with selector switch and 200/5 Amps 5VA CL: 1 CTs. |
| 263 | A set of R.Y.B. Phase indicating lamps shall be protected by suitable MPCBs |
| 264 | Notes: |
| 265 | All MCBs shall be of 10 KA breaking capacity and suitable for motor duty application. |
| 266 | All motor starter shall be provided with Automatic level controller. |
| 267 | Provision shall be made for providing potential free contacts to all pumps starters for connection to BAS |
| 268 | MCC- STP & ETP as described above |
| 269 | Installation/Commissioning and Training |
| 270 | CABLE & Wiring with Cable Trays Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender