Bids Are invited for Radiation Monitoring And Safety Device - Required Dosimetry System Including Minimum 4 Real Time Dosimeters And Display To Monitor Wearers Exposure To Xray Radiations In Real Time. , The Dosimeter Should Be Able To Measure And Re
Tender Overview
Project Description
Bids Are invited for Radiation Monitoring And Safety Device - Required Dosimetry System Including Minimum 4 Real Time Dosimeters And Display To Monitor Wearers Exposure To Xray Radiations In Real Time. , The Dosimeter Should Be Able To Measure And Record Radiation Every Second . The Dosimeter Should Always Measure And Store Dose Data On Its Internal Memory, Regardless Of Whether There Is A Display In Range Or Not , The Easy To Clip Real Time Dosimeters Should Not Have Any Audio Visual Alarms. , The System Should Provide Live Visual Feedback Every Second With Colour Coded Bars – Green, Yellow, Red On The Display , The Dosimeter Should Be Light Weight – Less Than 35 Grams , The Dosimeters Should Be Connected To The Central Display For Data Transfer Through Radio Communication Which Is Not Based On Bluetooth , The Real Time Dosimeters Should Function On User Replaceable Battery, Each Working For Min 1 Year , Energy Dependence Should Be < 25% (N-Series, 40 – 150 Kv) , Operational Quantity : Hp(10) , Response Time < 1 S, Above 100 Μsv/H , If 1 Year Warranty, Wherever Applicable Are Not Adhered To, Tmc Reserves Right To Reject The Offer. , Please Mention Whether Ups Is Required For The Equipment. If So Should Be Included In The Offer. , Only Yes Or No Should Be Mentioned In Compliance Report And Additional Information In Remarks Column. , Please Provide List Of The Consumables/Spares/Reagents/Control/Calibrators (If Any) In Technical Documents And Cost Of The Same Should Be Uploaded In Pdf File In The Financial Documents. , Do Not Mention / Upload Price And Cost In The Technical Documents Otherwise Your Quotation Will Be Disqualified At Technical Stage.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Required dosimetry system including minimum 4 real time dosimeters and display to monitor wearer’s exposure to xray radiations in real time. | Required dosimetry system including minimum 4 real time dosimeters and display to monitor wearer’s exposure to xray radiations in real time. |
| 2 | The dosimeter should be able to measure and record radiation every second . The dosimeter should always measure and store dose data on its internal memory, regardless of whether there is a display in range or not | The dosimeter should be able to measure and record radiation every second . The dosimeter should always measure and store dose data on its internal memory, regardless of whether there is a display in range or not |
| 3 | The easy to clip real time dosimeters should not have any audio visual alarms. | The easy to clip real time dosimeters should not have any audio visual alarms. |
| 4 | The system should provide live visual feedback every second with colour coded bars – green, yellow, red on the display | The system should provide live visual feedback every second with colour coded bars – green, yellow, red on the display |
| 5 | The dosimeter should be light weight – less than 35 grams | The dosimeter should be light weight – less than 35 grams |
| 6 | The dosimeters should be connected to the central display for data transfer through radio communication which is not based on Bluetooth | The dosimeters should be connected to the central display for data transfer through radio communication which is not based on Bluetooth |
| 7 | The real time dosimeters should function on user replaceable battery, each working for min 1 year | The real time dosimeters should function on user replaceable battery, each working for min 1 year |
| 8 | Energy dependence should be < 25% (N-series, 40 – 150 kV) | Energy dependence should be < 25% (N-series, 40 – 150 kV) |
| 9 | Operational quantity : Hp(10) | Operational quantity : Hp(10) |
| 10 | RESPONSE TIME < 1 s, above 100 μSv/h | RESPONSE TIME < 1 s, above 100 μSv/h |
| 11 | If 1 year warranty, wherever applicable are not adhered to, TMC reserves right to reject the offer. | If 1 year warranty, wherever applicable are not adhered to, TMC reserves right to reject the offer. |
| 12 | Please mention whether UPS is required for the equipment. If so should be included in the offer. | Please mention whether UPS is required for the equipment. If so should be included in the offer. |
| 13 | Only Yes or No should be mentioned in compliance report and additional information in remarks column. | Only Yes or No should be mentioned in compliance report and additional information in remarks column. |
| 14 | Please provide list of the Consumables/Spares/Reagents/Control/Calibrators (if any) in Technical Documents and cost of the same should be uploaded in PDF file in the Financial Documents. | Please provide list of the Consumables/Spares/Reagents/Control/Calibrators (if any) in Technical Documents and cost of the same should be uploaded in PDF file in the Financial Documents. |
| 15 | Do not mention / upload price and cost in the technical documents otherwise your quotation will be disqualified at technical stage. | Do not mention / upload price and cost in the technical documents otherwise your quotation will be disqualified at technical stage. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender