Tender For Repair & Maintenance Of Street Lights On V3,V4,V5,V6 Roads & Green Belt For Attending Online Complaints From August 2026 To October 2026 For Ward 21,22,33,34,35 Under Electrical Sub Division No. 3, Chandigarh.
Tender Overview
Project Description
Tender for Repair & Maintenance Of Street Lights On V3,V4,V5,V6 Roads & Green Belt For Attending Online Complaints From August 2026 To October 2026 For Ward 21,22,33,34,35 Under Electrical Sub Division No. 3, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | S/E of Collars of CC Collars including following:- a) The box shall be enclosed in a cement collar made form cement concrete 1:2:4 with outside dia. 16”.b) The collar shall be embedded in the ground up to 6” shall stand 9” above ground shall have housed 10” high SMC Box and 6” top over the box.c) The collar shall be provided with 2 PVC Pipes of 40mm dia. and 45cm long to facilitate entry of cables in the Jn.Box.d)n The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality. (e) Providing and Fing Junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement, provision for MCB/Kit installatin provision alongwith connector strip of 30 amps rating suitable for minimum 4x16 sq.mm aluminium cable termination. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect to the best satisfaction of Engg.in.charge. |
| 2 | G.I. Earth pipe electrode with salt/ Charcoal:-Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge. |
| 3 | P/F 6 SWG GI earth wire Providing & fixing earth connection from earth electrode with 6 SWG dia G.I. wire to pole. |
| 4 | Dismantling of existing Steel tubular pole 7.5/9 Mtr. Long along with Jn. Box, fittings with Wire & bracket etc. & other material complete in all respect to the satisfaction of Engineer-in-Charge. The contractor shall hand over the dismantled material to the J.E. In-charge at central store in proper form duly accounted.The poles to be dismantled at multiple locations in the area of sub division will be dismantled throughout the year, whenever online complaint will be rceived. Nothing extra will be paid for this. |
| 5 | Supply & erection of steel tubular 9 mtr pole 410 SP-27 conforming to IS-2713-1980, (Part-I & II) having overall length of 9 Meter and welded in 3 steps and having approximate Wt. 108 Kgs. With the following specifications: -a) The poll shall have cross-sectional length of 5.00, 2.00, 2.00 Mtrs.b) The outside dia and thickness shall be114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm.c) The pole shall be erected 1.50mtrs. Below the ground level in 8” internal readymade RCC muff.d) The gap between the pole and the muff shall be filled with the cement concrete 1:2:4. The cost includes all labour and material including carriage to the site of work. e) The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 6 | SUPPLY & ERECTION OF G.I.PIPE BRACKET 5 FEET O/H SINGLE ARM:-Supply and Erection of 5’ over hang bracket S/A made of G.I. pipe medium class ISI Marked with the following specifications of Make Tata/ Jindal. The work shall be executed to the entire satisfaction of engineer-in-charge.1. The bracket shall be made by G.I. pipe of 2” dia with an angle of inclination of 105 degrees to the vertical.2. The 2” dia G.I. pipe shall be welded to 3” dia G.I. pipe canopy at a distance of 2” from top end & top end of canopy shall be closed with 14 GMS sheet to avoid entry of rainwater in S.T. poles.3. The bracket shall be slipped over the top section of the steel tubular pole and fixed with 2 Nos. of ½” dia nuts and bolts suitable to hold the pipe absolutely tight in positions.4. Triangular 14 GMS sheet pieces of 6” diagonal shall be welded between two pipe.5. The sample of bracket shall be got approved from the Engineer in Charge before installation at the workshop where these are fabricated. |
| 7 | SUPPLY & ERECTION OF G.I.PIPE BRACKET 5 FEET O/H DOUBLE ARM:-Supply and Erection of 5’ over hang bracket Double Arm made of G.I. pipe medium class ISI Marked with the following specifications of Make Tata/Jindal/Hissar or Ravindra. The work shall be executed to the entire satisfaction of engineer-in-charge.1. The bracket shall be made from 2 ” dia G.I. pipe with an angle of inclination of 105 degrees to the vertical.2. The 2 ” dia G.I. pipe shall be welded to 3” dia G.I. pipe canopy at a distance of 2” from top end & top end of canopy shall be covered with 14 GMS sheet to avoid entry of rainwater in Steel Tubular Pole.3. The bracket shall be slipped over the top section of the steel tubular pole and fixed with 2 Nos. of ½” dia nuts and bolts suitable to hold the pipe absolutely tight in positions.4. A stiffnee plate of triangular shape of 14 G sheet of 6\\" dia shall be welded between two pipe.5. The sample of bracket shall be got approved from the Engineer in Charge before installation at the workshop where these are fabricated. |
| 8 | Painting and Numbering of 7.5/10 mtr long existing street light pole above ground level with two coats of Al. paint of superior quality alongwith single/ double/ triple arm/ round bracket. The pole surface should be cleaned well by removing dust/rust & other depositions .The job includes cost of labour required for holding the ladder and controlling the traffic while using crane/ boom.Numbering on the pole be done on two sides on each pole by painting 4\\" dia round with yellow paint and make number with black paint. The Cement collar around the pole should be painted with two coats of good quality white colored snowcem. The job includes the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge |
| 9 | Dismantling of old broken CC Collar and junction box and Digging of Existing Loops Upto 1 Mtr Below in Kutcha/Pakka Floor, Cutting, Dressing and Reconnections with Thimbles /Nuts &Bolts Complete in the Jn.Box And Lifting Any Malba From Site And Dumping at the C&D plant Industrial Area Phase-I. |
| 10 | Snowcen of CC Collar after removing of old snowcem. |
| 11 | Supply and erection of Junction Box cover of fibre sheet of 20\\"X5\\"/suitable size on existing octagonal pole. The fibre cover shall be installed on existing junction box with the help of screw. The job includes the cost of all labour charges and other petty material,nut & bolts required to complete the job upto entire satisfaction of Engineer-in-Charge. |
| 12 | Supply and erection of Junction Box cover of fibre sheet of approx 47\\"x10\\"/suitable size of high mast cover on existing high mast. The fibre cover shall be installed on existing junction box with the help of screw.The size of high mast should be measured before the supply of cover. The job includes the cost of all labour charges and other petty material,nut &bolts required to complete the job upto entire satisfaction of Engineer-in-Charge. |
| 13 | Providing and fixing of Pedestal Cover of size 1200x900x350 mm (16 SWG Sheet) with hinges, Red Paint 2 coat after red oxide primer , Fabrication, Welding & labour at site All T&P as required to the best satisfaction to the Engineer in-Charge. |
| 14 | Providing and fixing of Pedestal Cover of size 900x600x350 mm (16 SWG Sheet) with hinges, Red Paint 2 coat after red oxide primer , Fabrication, Welding & labour at site All T&P as required to the best satisfaction to the Engineer in-Charge. |
| 15 | Repair of Pedestal cover of size 1200X900X350 mm with Hinge,2 coat of paint, Welding & labour at site All T&P and Knob for door as required to the best satisfaction to the Engineer in-Charge. |
| 16 | Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.1 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 17 | Supply and laying of insulated 2 core x 10mm2 aluminium multi conductor twin core flat unarmoured cable to fixed on the suitable clamps and nuts /bolts etc make finolex/ lapp/ polycab/ havell's/ Cirtina or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge. |
| 18 | Supply and laying of insulated 2 core x4mm2 aluminium multi conductor twin core flat unarmoured cable make finolex/ lapp/ polycab/ havell's/ Cirtina or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge. |
| 19 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 20 | Supply & Erection of Three Phase Sensor based Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons /L&T/Scheinder or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-1. It shall have 3 contactors of capacity 40 Amp. Each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage. 2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet fo its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender