Tender For Supply, Installation, Testing & Commissioning (Sitc) Of One Passenger Lift At Executive Residence-01, Iim Indore
Tender Value
36.03 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
19 days left
EMD
72075
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing & Commissioning (Sitc) Of One Passenger Lift At Executive Residence-01, Iim Indore
BOQ
| Sl. No. | Item Description |
| 1 | Design, Supply, Installation, Testing & Commissioning (SITC) of Fully Automatic Machine Room Less (MRL), Gearless Electric Traction Passenger Lift of 8 Passenger (544 kg) Capacity with 2 Stops, complete with 24 months comprehensive OEM warranty, suitable for operation on 415 V ±10%, 3 Phase, 50 Hz AC supply, incorporating VVVF drive with microprocessor-based controller, SS 304 hairline finish three-side cabin enclosure (1.2–1.5 mm thick), automatic centre-opening front SS car and landing doors (1.5–2.0 mm thick) fitted with toughened clear vision glass panels (12 mm) in stainless steel framing, 6 mm thick tempered safety mirror on the rear wall extending up to full height with the bottom edge not extending below 900 mm above the finished lift floor, anti-skid flooring, stainless steel handrail, Car Operating Panel (COP) with Braille push buttons, |
| 2 | Landing Operating Panels (LOP), digital floor position indicators, voice annunciation, overload indicator, Automatic Rescue Device (ARD), full-height infrared light curtain, emergency alarm, automatic emergency lighting, ventilation fan, hands-free intercom compatible with the Institute's EPABX system, Fireman's Switch, phase failure, phase reversal, under-voltage and over-voltage protection, guide rails, controller, suspension ropes, counterweight, hoistway wiring, travelling cables, and all standard safety devices, fixtures, fittings and accessories, including loading, unloading, transportation, insurance, installation, testing, commissioning, statutory inspections, approvals, safety certification, labour, tools & plants (T&P), consumables, and all other materials, components and incidental works required for the complete, safe, reliable and satisfactory operation of the lift, as directed by the Engineer-in-Charge. |
| 3 | Statutory approvals, inspection and licensing assistance complete. |
| 4 | The indicative layout plan for entire lift system, including its connection with the main building is attached. However, The Contractor will first submit layout plan showing all dimensions as per site conditions as prepared by him & get it approved from IIM Indore before going ahead with structural design. The entire structural design (using structural steel sections)including electrical for lift system shall be done by the Contractor and the Contractor shall also get the design and drawings vetted by IIT Indore, all complete to the satisfaction of the Engineer-in-Charge. |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 7 | Excavation:- Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 9 | PCC:- 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 11 | (1) Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | (2) Suspended floors, roofs, landings, balconies and access platform |
| 13 | Providing and laying in position ready mixed or site batched Nominal design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level :Concrete of 1:1.5:3 grade with minimum cement content of 380 kg /cum |
| 14 | Brick work:-Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 15 | Plaster:- 18 mm cement plaster in two coats under layer (at all height) 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) with water proofing compound as mixing with dry cement as per manufacturer.Outer building area |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-550D |
| 17 | Scaffolding:- Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 18 | Toughened GlassProviding and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).(Make:- Saint-Gobain Glass, Asahi India Glass (AIS), Hardware- Ozone, Hafele )Note:- The Design of the toughened glass and its framing work shall be submitted by the vendor. |
| 19 | MS Structure:- Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer all complete.MS support structure (Grade of steel will be as pet IS codes & Approval of structural drawing by IIT) for lift well as per design drawing submitted by the vendor & vetted by the IIT for execution of the work. ( Make :- TATA, SAIL) |
| 20 | Tile Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 600x600 mm(Make:- Kajaria / Somany / Johnson). |
| 21 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm(Make: Kajaria / Somany / Johnson). |
| 22 | ACP Sheet for MRL :- Supply & Fixing of Peripheral ACP sheet of thickness 4mm with including all Fitting items with approved brand complete. As per approved design. (Make :- Viva/Wonder) |
| 23 | Granite :- Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby redArea of slab Over 0.50 sqm |
| 24 | Enamel paint:-Painting with synthetic enamel paint of approved brand and manufacture to give an evenshade :Two or more coats on new work ( make-Asian paints) |
| 25 | Primer:- Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 26 | Putty:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 27 | Paint:- Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats (Make :- Royale Luxury Emulsion Shyne-Asian paint/Velvet Touch Diamond Glo-Dulux Paint) |
| 28 | Paint:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as required at walls. (Make :- Royale Luxury Emulsion Shyne-Asian paint/Velvet Touch Diamond Glo-Dulux Paint) |
| 29 | Providing & applying water-proofing treatment of 2 K component, acrylic polymer based cementitious waterproofing coating system with 1:2 mix ratio, Adhesion to concrete 1.75 N/sqmm, polymer content > 18%.in Lifts area (2 coats), with a consumption of minimum 2 kg/sqm (make-Asian paints, pidilite or as approved by Engineer -Incharge )SR-12, SR-14, SR-16, and NLT (D & E Block) |
| 30 | Providing & applying PU Foam Grouting resin based Dr. fixit 230 or smart care from Asian paints PU at weaker points with expansion of 30 times, mix viscosity <350cP., bond strength 0.43N/sqmm for Lift area. The cost is Incliding the drilling with pressure machine & packers etc. all complete or as approved by Engineer –Incharge. The nozzle shall be metallic of company as approved by EIC.The hole position must be zig zag and spacing shall not more than 300 cc. or as decided by Engineer-In-Charge.After packer removal, damaged area shall be sealed with polymer modified mortar.SR-12, SR-14, SR-16, and NLT (D & E Block) |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Amp TPN |
| 32 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 AMP |
| 33 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 16 AMP Single pole and neutral |
| 34 | Supply of 10 sqmm 4 core armoured copper cable, make polycab/Finolex |
| 35 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 10 sq. mm (clamped with 1mm thick saddle) |
| 36 | Supply of 2.5 sqmm 2 core armoured copper cable, make polycab/Finolex |
| 37 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 2.5 sq. mm (clamped with 1mm thick saddle) |
| 38 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-C |
| 39 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 40 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 41 | Supply, installation, testing and commissioning of 15 W LED Bulkhead Light, surface mounted, die-cast aluminium/UV stabilized polycarbonate housing with opal diffuser, minimum 1650 lumens, efficacy ≥110 lm/W, PF ≥0.95, THD ≤10%, IP65, IK07, 140–270 V AC, 50 Hz, CRI ≥80, surge protection 4 kV, BIS approved driver, complete with all mounting accessories, wiring connections, testing and commissioning as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender