Health and Family Welfare Government Departments Closing in 20 days TDR #56748087

Tender For Nursing Hostel At Diphu Accf Hospital

Issued by Government Departments · Kamrup Metro, Assam
Tender Value
7.90 Crore
Estimated cost
Bid Submission
20 Aug 2026
20 days left
EMD
10 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Nursing Hostel At Diphu Accf Hospital

BOQ

Name of Work:- Nursing Hostel at Diphu ACCF Hospital
Sl. No. Item Description
1Nursing College at Diphu ACCF Cancer Hospital 1. ESTIMATE FOR CONSTRUCTION OF BSc. NURSING COLLEGE AT DIPHU CANCER CENTRE Sl. No. Description Unit Quantity Basic rate GST Amount A. CIVIL WORKS
2MASONRY WORK Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mmdia M.S. bars at every third course of masonry work. cum 148.16 0.0
3Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
4REINFORCED CEMENT CONCRETE CAST IN SITU Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). cum 6.63 0.0
5FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 72.9 0.0
6Columns, Pillars, Piers, Abutments, Posts and Struts
7STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 831.11 0.0
8FINISHING CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) sqm 1015.13 0.0
9PUTTY AND PRIMER WORK Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastere wall surface to prepare the surface even and smooth complete. sqm 12603.74 0.0
10Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre sqm 12603.74 0.0
11INTERNAL PAINTING Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats sqm 12603.74 0.0
12FALSE CEILING Providing and fixing mineral fibre false ceiling tiles at all heights of size595X595mm of approved texture, design and pattern. The tiles shouldhave Humidity Resistance (RH) of 99%, Light Reflectance ? 85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance asper (BS 476 pt - 6 &7)in true horizontal level suspended on interlockingT-Grid of hot dipped all round galvanized iron section of 0.33 mm thick(galvanized @120 gsm) comprising of main T runners of 15x32 mm oflength 3000 mm, cross T of size 15x32mm of length 1200 mm andsecondary intermediate cross T of size 15x32 mm of length 600 mmto form grid module of size 600x600 mm suspended from ceiling usinggalvanized mild steel item (galvanised@80gsm) 50 mm long 8mmouter diameter M-6 dash fasteners, 6 mm diameter fully threadedhanger rod up to 1000 mm length and L-shape level adjuster of size85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.The system should rest on periphery walls /partitions with the help ofGI perimeter wall angle of size24x24X3000 mm made of 0.40 mmthick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40 mm long dry wall S.S. screws. The exposedbottom portion of all T-sections used in false ceiling support systemshall be pre-painted with polyester baked paint, for all heights. Thework shall be carried out as per specifications, drawings and as perdirections of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre falseceiling tile (NRC 0.55 to 0.6 sqm 2084.28 0.0
13FLOORING VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet forplacing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size Size of Tile 600 x 600 mm sqm 1443.56 0.0
14Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm sqm 220.0 0.0
15WALL TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. sqm 402.34 0.0
16Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimumthickness of powder coating 50 micron) Kg 932.43 0.0
17For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately) Powder coated aluminium (minimumthickness of powder coating 50 micron) Kg 1262.02 0.0
18Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item): With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm) sqm 323.51 0.0
19Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod ofapproved quality as per architectural drawings and direction ofEngineer-in-charge complete. Upto 5mm depth and 5 mm width Rm 704.25 0.0
20Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screwsetc. complete : 300x16 mm each 131.0 0.0
21Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 200x10 mm each 374.0 0.0
22Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-incharge Powder coated minimum thickness 50 micron aluminium each 187.0 0.0
23Providing and fixing ISI marked aluminium butt hinges anodised (anodiccoating not less than grade AC 10 as per IS: 1868) transparent or dyedto required colour or shade with necessary screws etc. complete: 100x75x4 mm each 748.0 0.0
24Providing and fixing aluminium die cast body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossedon the body, door weight upto 35 kg and door width upto 700 mm), withnecessary accessories and screws etc. complete.
25Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessary screwsetc. complete. Single rubber stopper each 131.0 0.0
26Providing and fixing bright finished brass 100 mm mortice latch andlock, ISI marked, with six levers and a pair of anodised (anodic coatingnot less than grade AC 10 as per IS : 1868) aluminium lever handles ofapproved quality with necessary screws etc. complete.
27Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately). Sal wood Cum 5.66 0.0
28Accoustic Treatment for Ceiling 1) Suspension System – Supply & installation of G.I. ceiling suspension system comprising perimeter channels, main runners, cross tees and hangers, complete as per manufacturer's specifications, fixed to RCC slab/structural soffit at required spacing to support the acoustic ceiling system.2) Acoustic Insulation – Supply & installation of 50 mm thick Rockwool insulation (48 kg/m³ density) placed above the false ceiling as an acoustic infill for sound absorption and reduction of sound transmission.3) Acoustic Ceiling Panels/Tiles – Supply & installation of 15 mm to 20 mm thick acoustical mineral fiber/fabric wrapped acoustic ceiling panels having NRC not less than 0.80, fixed on exposed/concealed grid system as per approved drawings and manufacturer's recommendations.4) Edge Trims & Accessories – Supply & installation of wall angles, perimeter trims, clips, hold-down clips and all necessary accessories required for complete installation of the acoustic ceiling system.5) Jointing & Finishing – All joints, cut-outs, penetrations and edge conditions to be neatly finished. Acoustic sealant shall be applied at perimeter joints and service penetrations wherever required to maintain the acoustic performance of the ceiling system.6) Complete Installation – The work shall include all labour, materials, lifting, scaffolding, fixing accessories, wastage, cutting around MEP services, and all incidental items necessary to complete the acoustic ceiling treatment as per specifications and approved drawings.
29Cement Fiber Board partition wall 109mm thk. DRY WALL PARTITION 109MM THK.1) LGSF Structures - Supply & Erection of Steel G.I. 89mm (0.75mm thick having one flange of 41-43mm and another flange of 41-43mm) placed at 600mm c/c in 89 mm floor and ceiling channel (0.75mm thick having equal flange of 41-43mm G.I. steel) Coating GIZ275 and CFS Steel 345Mpa. (Detailed section detail attached)2) Cement Particle Board - Supply & Erection of 8-10mm thick Cement bonded Particle board both side of frame conforming to IS 14276, fixed on frame work using 25mm fully threaded self-embedding type Cement board Screws @300mm c/c on either side of Steel G.I. 89mm studs.3) Insulation - Supply & Erection of 50mm Thick Rockwool Insulation (48kg/cu-m density) to be used in between the cavity as an infill for sound insulation.4) Jointing Compound - Supply & Erection of resin based elastomeric Jointing Compound and glass fiber tape 16 mm wide to be surficially fitted at joint and finished with resin based jointing compound 100 mm wide.
30WF SPC Flooring
31Accoustic Treatment for Wall 30A False Ceiling with V Board 2X2 Board 4 mm thickness, Channel thickness 0.35 mm, 24 mm width and 24 inch length sqm 2084.28 0.0
32Only laying of vitrified tile with mortar B. PLUMBING WORKS
33Providing and fixing floor mounted, white vitreous china single piece,double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern ofcapacity 10 litres with dual flushing system, including all fittings andfixtures with seat cover, cistern fittings, nuts, bolts and gasket etcincluding making connection with the existing P/S trap, complete inall respect as per directions of Engineer-in-Charge.
34Providing and fixing controlled flush, low level cistern made of vitreouschina with all fittings complete. 10 litre (full flush) capacity-coloured Each
35Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushingcistern Each 15.0 0.0
36Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require: White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps Each 27.0 0.0
37Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink asper IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making goodthe walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm Each 10.0 0.0
38Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with plastic moulded frame of approvedmake and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm Each 27.0 0.0
39Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms.
40Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittingsarrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. Each 27.0 0.0
41Providing and fixing PTMT Waste Coupling for wash basin and sink,of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms Each 10.0 0.0
42Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 38 mm single piece moulded with height of270 mm, effective length of tail pipe 260 mm from thecentre of the waste coupling, 77 mm breadth with 25 mmminimum water seal, weighing not less than 263 gms Each 27.0 0.0
43Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mmdiameter of the inner hinged round grating Each 68.0 0.0
44Providing and fixing C.P. brass long nose bib cock of approved qualityconforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore Each 32.0 0.0
45Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931 15mm nominal bore Each 121.0 0.0
46Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete : 25 mm nominal bore Each 29.0 0.0
47Providing and fixing gun metal non- return valve of approved quality(screwed end) : 32 mm nominal bore Horizontal Each 6.0 0.0
48Providing and fixing unplasticised P.V.C. connection pipe with PTMTNuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length Each 121.0 0.0 47A Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Flexible pipe 40 mm dia Each 52.0 0.0
49Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, includingpainting of fittings and brackets, cutting and making good the wallswherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a15 mm CP Brass single hole basin mixer Each 37.0 0.0 48A Cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of Engineer-in-charge. Each 69.0 0.0
50Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes Rm 93.3 0.0
5120 mm nominal dia Pipes
5225 mm nominal dia Pipes
5332 mm nominal dia Pipes
5440 mm nominal dia Pipes
5550 mm nominal dia Pipes
56Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and makinggood the same including testing of joints complete as per directionof Engineer in Charge. Concealed work, including cutting chases and making good the wallsetc. 15 mm nominal dia Pipes Rm 223.05 0.0
5720 mm nominal dia Pipes
5825 mm nominal dia Pipes
59Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes confirming to IS:15801 UV stabilized & anti - microbial fusionwelded, having thermal stability for hot & cold water supply, includingall PP - R plain & brass threaded polypropylene random fittings,including trenching, refilling & testing of joints complete as perdirection of Engineer-in-Charge. External work PN - 10 Pipe, 50 mm OD (SDR-11) R.m. 114.0 0.0
60PN - 10 Pipe, 75 mm OD (SDR-11)
61PN - 10 Pipe, 110 mm OD (SDR-11)
62Health Faucet 1.5 Mtr. C. INTERNAL ELECTRICAL WORKS
63Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A Point 1268.0 0.0
64Group B
65Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required.
66Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire meter 4575.78 0.0
67Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. 20 mm meter 510.0 0.0
6825 mm
69Supplying and installing following size of perforatedHot Dipped Galvanised Iron cable tray (Galvanisationthickness not less than 50 microns) with perforationnot more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with twonumbers GI Suspenders i/c base of suitable size GIangle, GI bolts & nuts, fastner etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness meter 216.0 0.0
70300 mm width X 62.5 mm depth X 2.0 mm thickness
71Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet 13.0 0.0
72Supplying and drawing co-axial TV cable RG-6 grade,0.7 mm solid copper conductor PE insulated, shieldedwith fine tinned copper braid and protected with PVCsheath in the existing surface/ recessed steel/ PVCconduit as required.
73Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
74Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) each 21.0 0.0
754 Module (125mmX75mm)
766 Module (200mmX75mm)
778 Module (125mmX125mm)
7812 Module (200mmX150mm)
79Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
80Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
81Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
82Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door each 8.0 0.0
8312 way (4 + 36), Double door
84Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole each 483.0 0.0
85Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required.
86Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A each 10.0 0.0
87Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A each 30.0 0.0
88Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing masonry open duct asrequired. Upto 35 sq. mm meter 184.0 0.0
89Above 185 sq. mm and upto 400 sq. mm
90Laying and fixing of one number PVC insulated andPVC sheathed / XLPE power cable of 1.1 KV grade offollowing size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) meter 752.0 0.0
91Above 185 sq. mm and upto 400 sq. mm (clampedwith 40x3mm MS flat clamp)
92Supplying and making end termination with brasscompression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade asrequired. 3½ X 25 sq. mm (28mm) each 40.0 0.0
933½ X 300 sq. mm (70mm)
94Providing and fixing 4.00 mm dia copper wire onsurface or in recess for loop earthing as required.
95Supplying, installation, testing & commissioning of heatdetector operating at 54ºC/57ºC with rate of rise cum fixedtemperature (dual thermistor) type with mounting basecomplete with all connection etc. as required.
96Intregation with the existing fire system
97Supplying, installation, testing & commissioning of intelligentanalog addressable smoke detector/multeria criteria detector complete withmounting base complete as required.
98Supplying, installation, testing & commissioning of responseindicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required.
99Supplying, installation, testing & commissioning of intelligentaddressable programmable sounder complete as required.
100Supplying, installation, testing & commissioning of faultisolator complete with base as required.
101Supplying, installation, testing & commissioning ofaddressable fire control module complete as required.
102Supplying, installation, testing & commissioning of intelligentaddressable duct detector including suitable Photo detectorcomplete with base as required.
103Supplying, installation, testing & commissioning ofaddressable manual call point complete as required.
104Supplying, installation, testing & commissioning of fire fightertelephone handset complete as required.
105Supplying, installation, testing & commissioning of fire fighterphone jack complete as required.
106Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required.
107LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 12 -15 watt each 615.0 0.0
10818 watt
109Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 36 watt each 516.0 0.0
110Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 40 watt each 16.0 0.0
111Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) each 189.0 0.0
112Supply of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 & 1/2 Core A2XFY 25.00 Sq. mm.3 & 1/2 Core U.G. armoured cable each 936.0 0.0
113300.00 Sq. mm.3 & 1/2 Core U.G. armoured cable D. FIRE FIGHTING WORKS SUB HEAD- II PIPES & ACCESSORIES
114Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(FOR DRAIN PIPE) 50 mm dia Rm 10.0 0.0
11580 mm dia
116Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel(SS-304) Set 4.0 0.0
117Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure atthe outlet to the level of 3.5 kg/cm2complete as required.
118Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless Steel (Grade 304) Set 8.0 0.0
119Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m Set 4.0 0.0
120Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) Each 4.0 0.0
121Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete : 25 mm nominal bore Each 4.0 0.0
122Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler (Quick Response) Each 371.0 0.0
123Upright Sprinkler (Quick Response)
124Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete asrequired. 1000mm Set 200.0 0.0
1251500mm
126Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. SUB HEAD- II PIPES & ACCESSORIES
127Providing, laying, testing & commissioning of 'C' class heavy duty GI pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia Rm 692.0 0.0
12832 mm dia
12940 mm dia
13050 mm dia
13165 mm dia
13280 mm dia
133100 mm dia
134150 mm dia
135Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI, short pieces, nipples, elbows, stainless steel 'U' tube & ball valve, etc as required as per specifications.
136Providing and fixing standard firemans axe with heavy insulated rubber handle tested for 20000 watts
137Providing and fixing inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete as per drawing and as per specifications.
138SUB HEAD- III FIRE EXTINGUISHER Capacity 4.5 Kg Each 16.0 0.0
139Providing and fixing ABC' stored pressure type Dry Chemical Powder fire extinguisher with fixing hangers, hose, brackets, screws to required size etc., complete .Confirming to IS:15683 Capacity 6Kg Each 16.0 0.0 E. HVAC WORKS VRV AIR CONDITIONING SYSTEM (VRV system performance shall be in compliance with the recommendations mentioned in ASHRAE-90.1.2010)
140Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) For Cooling or Heating or Both 50 HP Per HP 50.0 0.0
14138 HP
14234 HP
14332 HP
14430 HP
14526 HP
14624 HP
14720 HP
14814 HP
14912 HP
150Supply, Installation, Testing and Commissioning of following minimum capacity 4 way VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) 1.2 TR Nos. 1.0 0.0
1511.6 TR
1522.0 TR
1532.5 TR
154COPPER REFRIGERANT PIPING Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm meter 56.0 0.0
15534.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
15628.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
15722.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
15819 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
15915.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
16012.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
1619.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
1626.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
163Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs Indoor Units Each 12.0 0.0
164Outdoor Multi Joint
165HI - WALL SPLIT SYSTEMS Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating Each 4.0 0.0
166DUCTING, GRILLE, DIFFUSER AND INSULATION Supplying, fabricating, installing and testing of factory fabricated sheet metal ducts of following thicknesses including necessary supports, flexible hangers with isolators, flexible connections, nut bolts, gasket, splitter dampers and vanes, volume control dampers etc. complete as per specification in accordance with the approved shop drawings and required by the specifications. GSS Ducting: Thickness 0.63 mm sheet Sqm 1722.0 0.0
167Thickness 0.80 mm sheet
168Thickness 1.00 mm sheet
169Sheet Metal Duct site fabricated: Supplying, fabricating, installing and testing of site fabricated sheet metal ducts of following thicknesses including necessary supports, flexible hangers with isolators, flexible connections, nut bolts, gasket, splitter dampers and vanes, volume control dampers etc. complete as per specification in accordance with the approved shop drawings and required by the specifications. GSS Ducting: Thickness 0.63 mm sheet Sqm 431.0 0.0
170Thickness 0.80 mm sheet
171Thickness 1.00 mm sheet
172Volume Control Damper: Supplying, installing, and testing of GI volume control damper within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per approved shop drawings. Sqm 12.0 0.0
173Supply Air Grilles: Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per technical specifications with all the necessary mounting accessories as required for complete installation. Sqm 23.0 0.0
174Return Air Grilles: Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as per technical specifications with all the necessary mounting accessories as required for complete installation. Rm 454.0 0.0
175Thermal Insulation: Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm thick insulation. Sqm 1216.0 0.0 ELECTRICAL WORKS :
176Cable Termination Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cableof 1.1KV grade as required 3.5C x 120sq.mm (45mm) Each 2.0 0.0
1773.5C x 35sq.mm (32mm)
1783.5C x 25sq.mm (28mm)
1794C x 16sq.mm (28mm)
1804C x 10sq.mm (25mm)
1813C x 6sq.mm (19mm)
1824C x 6sq.mm (19mm)
183Cable Tray: Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm width x50 mm depth x 2.0 mm thick meter 30.0 0.0
184450 mm width x50 mm depth x 2.0 mm thick
185300 mm width x50 mm depth x 1.6 mm thick
186150 mm width x50 mm depth x 1.6 mm thick
187100 mm width x50 mm depth x 1.6 mm thick
188Supplying and fixing of following sizes of medium class PVC conduit along with accessories insurface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm dia. meter 200.0 0.0
189G.I. Earthing Strip/Wire: Supply, installation, testing and commissioning of following sizes of G.I. strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System / Lightning protection earthing complete as required including inter connection between length at joints, all fixing accessories saddles, clamps etc. and other fixing hardware material as required for proper installation. 25 mm x 5 mm GI strip meter 50.0 0.0
1906 SWG wire VRV COMPATIABLE AIR HANDLING UNITS
191Supply, installation, testing and commissioning of factory fabricated Weather proof outdoor rated Double Skinned refrigerant based Horizontal/ Vertical/ Ceiling Suspended eurovent certified air handling units fabricated out of 1.2mm pre-coated Aluzinc / PPGI steel sheet outside & 0.8mm Pri-plasticized Galvanised steel sheet inside. Alternatively, 0.8 mm plain 275 GSM Galvanised steel inside sheet can be provided. The unit shall be provided with Backward curved aerofoil blade Plug type direct driven fan, IE-3 TEFC type VFD compatiable motor suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Cooling coil with flange for pipe connection, made of Aluminium finned Copper tube with coil section, pre-filter section with non wovensynthetic media of 10 micron particle size with an efficiency of 90%, Sandwitch type insulated SS-304, stainless steel drain pan. The motor should be suitable for operation on VFD. Sound should not exceed 65 to 67 dDA at 3 meter from AHUs and should be selected for maximum efficiency. Damper at AHU discharge to control the air volume and Fire retardent Canvass connection for connection with duct. The Fan unit panels shall be insulated with 40mm thick & 36 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The Fan unit shall conform to standard specification. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across cooling coil shall be limited to 152 MPM maximum. Unit shall be provided with sloped top canopy with EPDM gasket and wire mesh guard on fresh air opining for terrace level-out door installation. AHU VRV Refrigerant kit with thermostat, Electronic Expansion valve and Control unit with all accessories and refnet. Limit switches with control wiring at fan section door to switch off the fan motor when fan section is opened. Price to include light point, light within the fan section alongwith wiring & earthing. All external electrical panel, JB shall be IP-55 rated weather proof. All external fasteners, hinges latches shall be SS-304. Curtain hooks at coil section for provision to install/ fix a water proof curtain to avoid travel of water to AHU fan section when coils are cleaned with water jet. Actual static pressures shall be checked by the vendor and consider accordingly and no extra cost shall be paid later incase any change of static pressure required during execution. Mixing box construction shall be same construction as AHU. Mixing box shall be provided with opening with VCD for return air and fresh air. Note: Contractor shall order the AHU and related equipment/accessories only after the approval from the consultant/architect/client's representative. The AHU shall be BMS compatible. 11000 CFM capacity floor mounted AHU, 6 row deep cooling coil , TSP 65mm Wg witg mixing box. Nos. 1.0 0.0
1928000 CFM capacity floor mounted AHU, 6 row deep cooling coil , TSP 65mm Wg witg mixing box.
1935500 CFM capacity floor mounted AHU, 6 row deep cooling coil , TSP 65mm Wg witg mixing box.
1944500 CFM capacity floor mounted AHU, 6 row deep cooling coil , TSP 65mm Wg witg mixing box.
1952500 CFM capacity floor mounted AHU, 6 row deep cooling coil , TSP 45mm Wg witg mixing box.
1961500 CFM capacity floor mounted AHU, 6 row deep cooling coil , TSP 45mm Wg witg mixing box.
197Drain piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification. 32 mm ID Rmt 60.0 0.0
19825 mm ID VENTILATION SYSTEM: FIRE RATED AXIAL FLOW FANS:
199Supply, installation, testing and commissioning of Axial flow fan complete with TEFC squirrel cage motors with H class insulation and IP 55 protection, as per the specifications enclosed. The fans should be AMCA certified for air performance & sound ratings and the fan should be selected for maximum efficiency. The fan should be rated for a minimum of 250 Deg C for a minimum of 2 Hrs. application. 8000 CFM Exhaust Air (25mm Static Pressure. Maximum sound power level at source (LWA) -90 DBA) Nos. 2.0 0.0
2004000 CFM Exhaust Air (25mm Static Pressure. Maximum sound power level at source (LWA) -90 DBA)
201Inline Fans : Supply,installation,testing and commissioning of Inline Fans exhaust/Fresh air fans complete with fire retardant Canvas gravitational louvers , bird skin, power and control wiring between the sockets and the fans of following sizes: 550 CFM (20mm Total Static Pressure) Nos. 3.0 0.0
202450 CFM (20mm Total Static Pressure)
203250 CFM (20mm Total Static Pressure) Propeller Fan
204Supply, installing, testing and commissioning of following Propeller fan gravity louver, Aluminium blades complete with induction Motor suitable for operation with 230 V 1 phase 50 Hz including providing suitable size opening in wall with suitable frame etc as per technical specifications with all the necessary mounting accessories as required for complete installation. The impeller of fan shall be ABS plastic or powder coated GI sheet. 225 Dia with 3-5mm TSP Nos. 1.0 0.0
205150 Dia with 3-5mm TSP
206Flexible Connection: Supplying, fabricating, installing and testing of 150mm long silicon based flexible connection with both side flanges constructed of fire resistant material as per the drawings/ specifications. Quantity is mentioned considering perimeter length. RM 20.0 0.0
207Louvers without VCD: Supplying, installing and testing of air Al outlet louvers with bird screen complete as per specification & drawings. Sqm 6.0 0.0
208Louvers with VCD: Supplying, installing and testing of aluminium air louvers with volume control damper, fresh air filter and bird screen complete as per specification & drawings. Sqm 6.0 0.0
209Supplying, Fixing,testing and commissioning of fusible link fire dampers in supply air duct/main branch and return air path as and where required of required sizes complete as required and as per specifications. Fusible Link Sqm 4.0 0.0
210Acoustic Lining of Ducts: Supplying, installing & testing of acoustic lining within supply and return air ducts as per the specifications. All ducts shown cross hatched on the approved shop drawings shall be provided with acoustic lining of open cell nitrile rubber insulation with density 140-160 Kg/ cum as per the specifications. 15 mm thick Sqm 25.0 0.0 ELECTRICAL WORKS :
211VRF Outdoor panel-1 Terrace (25KA ,IP-55) Incoming 1 Nos. 800A, 25KA 4P Microprocesser Relese MCCB WITH Adjustable O/L, S/C&E/F protection unit having following protection; 1 No. 800 Amps 4P AC3 duty contactor with following accessories,• ON/ OFF push button, • Auto/ Manual Switch, • Delay timer • electrically/ mechanically interlocking Metering & Indication 1No. Digital energy meter (DEM) for measuring following electrical parameters, 3 No. 800/5 amps 7.5VA CTs, Cl -1 • Current WITH RS-485.• Voltage• Frequency Phase indicating light shall be protected by 2 Amps SP MCB's. - 1 Set ON / OFF/ TRIP indicating lights with control 2 Amps SP MCB's. - 1 Set Bus Bar Electrolytic high conductivity aluminium three phase and neutral busbars rated at 1000 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25kA at 415 V. The neutral busbar is to be of same size as phases. Outgoing 2 No. 25A amp 4P 300 mA RCBO 5 No. 63 A amp 4P 300 mA RCBO 4 No.100A amp 4P 300 mA RCBO 1 No.125A amp 4P 300 mA RCBO 1 No. 63 A amp 4P 300 mA RCBO spare 1 No.100A amp 4P 300 mA RCBO spare 1 No.160A amp TPN MCCB (For AHU panel) 1 No. 63A amp TPN MCCB spare VRF Outdoor panel-1 described as above Set 1.0 0.0
212AHU panel-1 - Terrace (25KA ,IP-55) Outdoor rated Incoming 1 Nos.160A, 25 KA 4P Thermal Magnetic Relese MCCB WITH Adjustable O/L, S/C & &E/F Protections . 1 set of RYB & ON OFF TRIP indication lamp 1 set. cast resin current transformers of 160/5A ratio with 7.5 VA Burden & Class 1.0 with Ammeter with selector switch. 1 No 0-500 V voltmeter with selector switch. Bus Bar Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 25kA at 415 V. The neutral busbar is to be of same size as phases. Outgoing 1 Nos. suitable rating of TP MPCB for 11.0 KW motor with space for VFD starter and including star delta by-pass stater with On Off Trip Indication Lamp, A/M switch with 2A MCB. 4 Nos. suitable rating of TP MPCB for 7.5 KW motor with space for VFD starter and including sDOL Starter by-pass stater with On Off Trip Indication Lamp, A/M switch with 2A MCB. 2 Nos. suitable rating of TP MPCB for 5.5 KW motor with space for VFD starter and including DOL Starter by-pass stater with On Off Trip Indication Lamp, A/M switch with 2A MCB. 1 Nos. suitable rating of TP MPCB for 3.7 KW motor with space for VFD starter and including DOL Starter by-pass stater with On Off Trip Indication Lamp, A/M switch with 2A MCB. 1 Nos. suitable rating of TP MPCB for 2.2 KW motor with space for VFD starter and including DOL Starter by-pass stater with On Off Trip Indication Lamp, A/M switch with 2A MCB. 1 Nos. suitable rating of TP MPCB for 1.5 KW motor with space for VFD starter and including DOL Starter by-pass stater with On Off Trip Indication Lamp, A/M switch with 2A MCB. 13 No. 10A amp sp MCB . 1 No. 40A amp 4P MCB spare 1 No. 63A amp 4P MCB spare AHU panel-1 - described as above Set 1.0 0.0
213VFD Starter for AHUs/ TFAs etc. 1 No. IP-55 variable frequency drive with mains disconnect switch suitable for 11.0 KW motor. 1.0 0.0 4 No. IP-55 variable frequency drive with mains disconnect switch suitable for 7.5 KW motor. 2.0 0.0 2 No. IP-55 variable frequency drive with mains disconnect switch suitable for 5.5 KW motor. 4.0 0.0 1 No. IP-55 variable frequency drive with mains disconnect switch suitable for 3.7 KW motor. 1.0 0.0 1 No. IP-55 variable frequency drive with mains disconnect switch suitable for 2.2 KW motor. 1.0 0.0 1 No. IP-55 variable frequency drive with mains disconnect switch suitable for 1.5 KW motor. 1.0 0.0
214Cable Tray Cover: Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cover (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
215600 mm width x50 mm depth x 2.0 mm thick
216450 mm width x50 mm depth x 2.0 mm thick
217300 mm width x50 mm depth x 1.6 mm thick
218150 mm width x50 mm depth x 1.6 mm thick
219Supply, Laying, installation, testing and commissioning of following 1100 volt grade PVC FRLS sheathed XLPE 2XFY insulated aluminium conductor armoured cables as per specification in existing RCC/PVC pipe/Burried in ground or on cable trays, includes anchor fasteners with clamps, saddles fixing bolts, 1.2 mm thick aluminium engraved tags at both ends, etc. As per technical specifications with all the necessary mounting accessories as required for complete installation. 3.5cx120 Sq. mm. Al. Ar. XLPE Cable RM 60.0 0.0
220Supply, Laying, installation, testing and commissioning of following 1100 volt grade PVC FRLS sheathed XLPE 2XFY insulated copper conductor armoured cables as per specification in existing RCC/PVC pipe/Burried in ground or on cable trays, includes anchor fasteners with clamps, saddles fixing bolts, 1.2 mm thick aluminium engraved cable tags at both ends, etc. As per technical specifications with all the necessary mounting accessories as required for complete installation. 3.5cx35 Sq. mm. Cu. Ar. XLPE Cable RM 35.0 0.0
2213.5cx25 Sq. mm. Cu Ar. XLPE Cable
2224cx16 Sq. mm. Cu. Ar. XLPE Cable
2234cx6 sq mm Cu. Ar. XLPE Cable
2244cx10 Sq. mm. Cu. Ar. XLPE Cable
2253cx6 sq mm Cu. Ar. XLPE Cable
226Supply, installation, testing and commissioning of following cables: Supply and laying, testing & commissioning of following sizes of copper conductor Communication cables on existing tray including fixing clamps & proper connections to equipment etc. complete as required. 2C x 1.5 Sqmm. RM 200.0 0.0 F. CCTV SYSTEM WORKS
227CCTV System i) CP PLUS make 2 MP ip Dome/ Bullet camera 71 nos. Each 71.0 0.0 ii) Cp plus make 64 CH NVR 1 no. Each 1.0 0.0 iii) CP plus make 32 CH NVR 1 no. Each 1.0 0.0 iv) 16 port poe giga switch Make – Dlink 5 nos. Each 5.0 0.0 v) Seagate make 8 TB surveillance HDD 3 nos. Each 3.0 0.0 vi) D-link 6u/12u rack with Accessories 5 nos. Each 5.0 0.0 vii) Dlink make cat6 cable supply (305 mtr coil) 14 coil. Coil 14.0 0.0 viii) Pvc box with rj 45 connector 80 set. Set 80.0 0.0 ix) cable laying charges 4000 Rm. Rm 4000.0 0.0 x) 43” Display 4 nos. Each 4.0 0.0 Including installation testing and commissioning Job 1.0 0.0 Job 1.0 0.0 G. PA SYSTEM
228PA System ii) SITC of voice alarm call station with 6 zone selection keys & one all call key 2 nos. Each 2.0 0.0 iii) SITC of 6 w metal grill ceiling mount loudspeaker 90 nos. Each 90.0 0.0 iv) SITC of 480 w booster amplifier 2 nos. Each 2.0 0.0 v) SITC of compact mixer Amp with USB & bluetooth 1 no. Each 1.0 0.0 vi) SITC of 1.5 sq.mm vasiform ATC speaker cable (coil of 100m) 35 coil. Coil 35.0 0.0 vii) SITC of cat6 cable (coil of 305m) 1 coil. Coil 1.0 0.0 viii) PVC conduits (20mm, 3m) Job 1.0 0.0 Job 1.0 0.0 H. NETWORKING & SERVER WORKS
229Networking Server :i) Network Manage Switch Make: tp-Link Config: 24-port, PoE, 10/100/1000, SFP, O_C-Support HSN: 85365010 10 nos.ii) Network Manage Switch Make: tp-Link Config: 16-port, PoE, 10/100/1000, SFP, O_C-Support HSN: 85365010 2 nos.iii) Network Management Rack Make: D-LiinkConfig: 9U FL PDU WM HSN: 85341010 8 nos.iv) Network Connecting & Plug AccessoriesMake: D-LinkConfig: Patch Panel 24-PortHSN: 85367000 10 package.v) IO Box Component 01 Make: D-Link Config: CAT6 with all fittings, Single port HSN: 85177090 210 nos.vi) Networking Cable Box Make:m D-Link/ Fedus Config: Cat6 In Box: 305 Mtrs HSN: 85444999 28 box.vii) UPS 1000 VA Make: Cyber Power Config: 1 KV, IBB AVR HSN: 84715000 8 nos.viii) Router Broad and Plug-in Network Management Router & Controller Make: TP-Link, Config: L3 managed with Firewall HSN: 8517 1 no.ix) Network Connecting & Plug Accessories Accessories, PVC Casing, Cat 6 1 Mtr Patch Code HSN: 85367000 1 package.x) One Time Installation Charge Installation & Config with Testing SAC: 998736 210 job. i) Network Manage Switch Make: tp-Link Config: 24-port, non -PoE, 10/100/1000, SFP, O_C-Support HSN: 85365010 10 nos. Each 10.0 0.0 ii) Network Manage Switch Make: tp-Link Config: 16-port, PoE, 10/100/1000, SFP, O_C-Support HSN: 85365010 2 nos. Each 2.0 0.0 iii) Network Management Rack Make: D-LiinkConfig: 9U FL PDU WM HSN: 85341010 8 nos. Each 8.0 0.0 iv) Network Connecting & Plug AccessoriesMake: D-LinkConfig: Patch Panel 24-PortHSN: 85367000 10 package. Package 10.0 0.0 v) IO Box Component 01 Make: D-Link Config: CAT6 with all fittings, Single port HSN: 85177090 210 nos. Each 210.0 0.0 vi) Networking Cable Box Make:m D-Link/ Fedus Config: Cat6 In Box: 305 Mtrs HSN: 85444999 28 box. Box 29.0 0.0 vii) UPS 1000 VA Make: Cyber Power Config: 1 KV, IBB AVR HSN: 84715000 8 nos. Each 8.0 0.0 ix) Network Connecting & Plug Accessories , Cat 6 1 Mtr Patch Code HSN: 85367000 1 package. Package 1.0 0.0 Job 1.0 0.0 I. TELEPHONE & INTERCOM SYSTEM WORKS
230Telephone & Intercom System 1. EPABX Intercom Systemii) 20 Nos Lend-Line Receiveriii) 20 P DP Box, CT Box, RJ6 Cable, Surface Box, RJ11 Outlet HSN: 85176290 1 package. 2. One Time Installation Charge Installation, Configuration & Testing SAC: 998736 1 job. Job 1.0 0.0 TOTAL COST (A+B+C+D+E+F+G+H+I) with gst 0.0 0.0 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56748087
AUTHORITY Government Departments
TENDER VALUE 7.90 Crore
LAST DATE 20-08-2026
Authority
Authority Name Assam Cancer Care Foundation
Work Description Tender for Nursing Hostel At Diphu Accf Hospital
Basic Detail
Tender No ACCF/Nursing College /26-27/133
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 30 Jul 2026
Submission Date 20 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 7.90 Crore
Tender Fee 1000
EMD 10 Lakhs
Exemption Not Available
Document List
b2480872-bab7-42a5-8629-374f9f944b37.html
BOQ_83905.xls
DRAWINGS1.rar
RFP.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

b2480872-bab7-42a5-8629-374f9f944b37.html

xls

BOQ_83905.xls

rar

DRAWINGS1.rar

pdf

RFP.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders