Tender For Construction Of Sewage Treatment Plant (Stp) Of Capacity 20 Mld And Construction Of Main Pumping Station (Mps) Of Capacity 45 Mld (Peak Flow) Including 5 Years O&M And Providing, Laying, Jointing, Testing And Commissioning Of: (A) 700 Mm I
Tender Overview
Project Description
Tender for Construction Of Sewage Treatment Plant (Stp) Of Capacity 20 Mld And Construction Of Main Pumping Station (Mps) Of Capacity 45 Mld (Peak Flow) Including 5 Years O&M And Providing, Laying, Jointing, Testing And Commissioning Of: (A) 700 Mm I/D Di-K9 Pumping Main From Proposed Mps To Inlet Of 20 Mld Stp (B) 1200Mm Dia Rcc-Np3 With Hdpe Liningmain Gravity Sewer Line From Existing Mh To Proposed Mps At Ferozepurtown, District Ferozepur Under Amrut 2.0 Scheme
BOQ
| Sl. No. | Item Description |
| 1 | NIT No.: Date: STANDARD BIDDING DOCUMENT FOR PROCUREMENT OF WORKS Construction of Sewage Treatment Plant (STP) of capacity 20 MLD andConstruction of Main Pumping Station (MPS) of capacity 45 MLD (Peak flow) including 5 years’ O&M and Providing, Laying, Jointing, testing and commissioning of: (a) 700 mm i/d DI-K9 Pumping Main from proposed MPS to inlet of 20 MLD STP (b) 1200mm dia RCC-NP3 with HDPE Lining Main Gravity Sewer Line from existing MH to proposed MPS at Ferozepur Town, District Ferozepur under AMRUT 2.0 Scheme Volume -3 Project Value: Capital cost (Part- A, B & C) Percentage Rate : Rs. 461.77 Lakh Capital cost (Part- D):LS5 Years' O&M (Part- E): LS Price Bid JULY, 2026 NIT No.: Date: Name of Work: Construction of Sewage Treatment Plant (STP) of capacity 20 MLD and Construction of Main Pumping Station (MPS) of capacity 45 MLD (Peak flow) including 5 years’ O&M and Providing, Laying, Jointing, testing and commissioning of: (a) 700 mm i/d DI-K9 Pumping Main from proposed MPS to inlet of 20 MLD STP (b) 1200mm dia RCC-NP3 with HDPE LiningMain Gravity Sewer Line from existing MH to proposed MPS at FerozepurTown, District Ferozepur under AMRUT 2.0 Scheme Name of Bidder: General Summary S.No Particulars Total Amount (Rs) Capital Works: Percentage Rate- MPS and Sewer works (Part 1) |
| 2 | CIVIL (PART-A) |
| 3 | MECHANICAL WORKS (Part - B) |
| 4 | ELECTRICAL WORKS (Part - C) Estimate Amount (Part A+B+C ) (In Rs): 46177115.32994498 Enter Rate below without (+), (-) and (%) symbols For \\"At Par\\" Rate, Enter Zero. Percentage Above/Below/At Par At Par 0.0 % Amount as per percentage quoted, Percentage Rate (Part A,B & C) (Amount in Rs) 46177115.32994498 |
| 5 | Construction Phase and O&M Phase: LS (Part 2) Part - D Construction of 20 MLD Sewage Treatment Plant 0.0 Part - E 5 years' Operation and Maintenance cost MPS & STP 0.0 Sub Total: Part 2 (Part-D & E) 0.0 Total (Part-1 + Part-2): Bid Price 46177115.32994498 Amount In Words Four Crores Sixty One Lacs Seventy Seven Thousand One Hundred Fifteen Rupees and Thirty Two Paise Provisional Sum (Not part of bidding) Rs in Lakh = 407.90083393919247 Provisional Sum S.no. Description Unit Qty Amt.(Rs.lakh) (A) Provisional Sum : Price Escalation = 3.75 % of Capital Cost ( @ 7.50 % per annum and average 3.75% per year) 94.7752499820025 Contingencies = 1 % of Capital Cost 25.27339999520067 Shifting of utilities 10.0 Electrical connections charges Main Pumping Station (Proposed) 19.27 STP 20 MLD 29.85 BT bill charges for road restoration (B&R) LS 10.0 Sub Total (A) Provisional Sum 189.1686499772032 (B) PWSSB Charges and Cess : Contingencies Charges on work @ 1% ( To be paid on actual limited to maximum @ 1% of Capital cost) 27.61769999520067 PWSSB ( Admin ) Charges @ 6 % on Capital Cost 165.706199971204 Third Party Inspection Charges @ 0.92% 25.408283995584615 Sub Total (B) Provisional Sum 218.73218396198928 Total (A+B) Provisional Sum 407.90083393919247 Provisional Sum (in Lakhs) 407.90083393919247 Lump Sum Rate (Construction of 20 MLD Sewage Treatment Plant ) Sl.no. Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) Capital Works |
| 6 | Designing, providing, constructing, hydraulic testing, commissioning of new STP of Capacity 20 MLD including 3 months stabilization period based on any suitable, sustainable and proven technology, meeting treated effluent quality parameters consisting of Inlet Chamber, Screen Chamber, Grit-Detritus Tanks, Distribution Chamber, Cyclic Aerobic Reactor Basins, Chlorine Contact Tank, Chlorinator with Chlorinator Room & Tonner Room, Chemical Storage & Dosing shed with dosing Equipment, Blower Room, Metering Room, Sludge Sump, Sludge dewatering system and building, Raw sewage bypass system from pumping header and sludge storage shed, necessary piping work with required valves, gates, storm water drains and rain water harvesting system, roads & pathways (including restoration of existing interlocking tiles/ brick on edge etc. near proposed MPS), landscaping, Laboratory Equipment , Tools and Spare Parts to be placed in existing building, etc. complete as turnkey job with all involved civil, electrical, instrumentation and mechanical works inclusive of all above items, units as per detailed specification for civil, electrical, instrumentation and mechanical components with all duties and taxes, etc. complete to get reusable quality of water for agricultural purposes including PLC-SCADA and Instrumentation and treated wastewater disposal to location as per directions of Engneer. Sub-Total Part - D Sub Head -6: Capital Works ( In Rs) 0.0 Part - E: Lump Sum Rate for 5 years’ Operation and Maintenance for MPS of Capacity 45 MLD, 20 MLD STP and 700 mm i/d DI-K9 Pumping Main from proposed MPS upto 20.0 MLD STP & other related works S. No. Period Unit Total Qty Rate Amount Amount In words (In Rupees) (In Rs) (In Rs) |
| 7 | Construction period (30 Months incl. stabilization period of STP) |
| 8 | 1st Year. |
| 9 | 2nd Year. |
| 10 | 3rd Year. |
| 11 | 4th Year. |
| 12 | 5th Year. Total (PART - E) 05 Years' O&M in Rs. 0.0 No Rupees and No Paise CIVIL WORKS Sr.no CSR Ref. Description Unit Qty Rate(Rs) Rate (Rs. In Words) Amount (Rs) 1.Capital Works ' CSR based Items ( Part -A) - CIVIL Sub - Head -1 Dismantling Work : PCC : |
| 13 | 8.6 (a) RCC : |
| 14 | 8.41 Brick work : |
| 15 | 8.39 Steel work : |
| 16 | 8.46 Doors and Windows : |
| 17 | 8.44 Wire gauge doors : |
| 18 | 8.32 Conglomerate floor ; |
| 19 | 8.16 Terracing ; 8.31 Scraping : |
| 20 | (g) 8.8 Dismantling roofing: |
| 21 | (a) Carriage of Good Earth |
| 22 | 5.2 (i) from 10 km. Credit of old/unserviceable material |
| 23 | Sub - Head -2 Re- Construction : (i) Constrcution of Meter Room 3.5 x 3.5 Mtrs. Excavation : |
| 24 | 6.19 CC 1:4:8: 10.13 Cement concrete 1:4:8 a With stone ballast or shingle |
| 25 | 10.27 |
| 26 | 11.4 (i) |
| 27 | 15.9 M-25 : |
| 28 | 10.16 Flooring : 40 mm.Thick Grey Polished Floor : |
| 29 | 14.1 Floating Coat : |
| 30 | 14.4 Terracing : |
| 31 | 13.13 (i) |
| 32 | 13.55 Rain water pipe : |
| 33 | 13.74 Top Khurra : |
| 34 | 13.45 uPVC Pipe : 28.12 Providing and laying,jointing,fixing and testing ISI Marked uPVC Pipe Lines as per IS:4985-2000, including specias such as tees,bends,sockets,elbows etc. cutting,testing (including cost of specials) in the ground complete in all respects. B UPVC Pipe 10 Kgf/cm2 |
| 35 | b Upvc Bend : 13.75 Providing and fixing 110 mm. dia. U.P.V.C bend for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge. |
| 36 | (a) Upvc Coupling/socket : 13.76 Providing and fixing 110 mm. dia. U.P.V.C Coupling / Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge. |
| 37 | (a) Door & Windows |
| 38 | 17.45 (a) |
| 39 | 17.45 (b) |
| 40 | 17.46 (ii) Steel : |
| 41 | 18.18 Shuttering : |
| 42 | 9.8 Distemper : |
| 43 | 16.1 Diff.in Rates of materials : |
| 44 | Carriage of Materials : 5.2 (i) Earth, Surkhi, Sand, earth, Fly Ash, Bajri, Ballast, Stone Boulders, Kankar and Building Rubbish, Earth |
| 45 | (ii) Boundary wall Excavation : |
| 46 | 6.19 CC 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle |
| 47 | ii M-30 : |
| 48 | 10.17 Steel : |
| 49 | 18.18 Shuttering : |
| 50 | 9.1 C / shuttering : ( Columns) |
| 51 | 9.4 C / shuttering : ( Beams) |
| 52 | 11.6 CP 20 mm.thk. : |
| 53 | 15.2 White wash : |
| 54 | 16.3 Dry distemper : |
| 55 | 16.7 Sliding Shutters : |
| 56 | 18.9 Diff.in Rates of materials : |
| 57 | Carriage of Materials : 5.2 (i) Earth, Surkhi, Sand, earth, Fly Ash, Bajri, Ballast, Stone Boulders, Kankar and Building Rubbish, Earth |
| 58 | Sub-Head-3: P/L RCC NP3 Main Gravity Sewer Line (i) 1200 mm i/d RCC NP3 Pipe Line 29.5 Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines,water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches,watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. i All kinds of soil except rocky |
| 59 | c 29.42 Providing, lowering in trenches to correct gradient andallignments, jointingwithtytone rubber joint and cuttingof RCCS/S pipes havinginsideHDPE. liningISImarekdasper ISI code IS:458-2003 into trenches for all depths and layingout the same to correct alignment, gradients, levels etc.,cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigidmanner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed.Thepipesshall rest on thebeds at all joints through their lengths and to ensurethis, testingthepipesfor leakageand making good the same leakage and all defects to the entire satisfaction of the Engineer incharge including all cartage etc. copmplete in all respects. A R.C.C. pipe with inside H.D.P.E. lining class- NP-3 |
| 60 | 28.48 |
| 61 | 10.13 a (ii) |
| 62 | 9.1 29.72 Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda |
| 63 | C (ii) Manholes 29.55 Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) with RCC core wall between masonary, R.C.C. top slab 20mm thick using M-20 mix, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame internal dimensions.complete as per standard design. (In water logged area). |
| 64 | (d) 29.57 Extra payable for every 0.30m additional depth of manhole chamber in item 29.56 upto 1.80 m increase in depth. |
| 65 | (d) (iii) Road Works (a) Dismantle of Road Work : Flexible pavements : |
| 66 | 24.3 (a) (b) Road Restoration Work Earthwork : 6.2 Earth work excavation in ordinary soil exclusive of compensation of earth |
| 67 | (a) Compacting Original Ground below embankment : |
| 68 | 24.4 (b) WBM Grade-II : 24.12 (ii) Water Bound Macadam Grading II (Without Screening for low volume Roads/ undesigned roads)Providing, laying, spreading and compacting stone aggregates of Grading II to water bound macadam specification including spreading in uniform thickness,hand packing, rolling with smooth wheeled roller 8 -10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications. |
| 69 | WBM Grade-I: 24.11 (ii) Water Bound Macadam Grading I (Without Screening for low volume Roads/ undesigned roads)Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical specifications |
| 70 | Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,Earth,FlyAsh,Bajri,Ballast,Stone Boulders, Kankar and Building Rubbish, Earth. Carriage of stone aggregate : (For WBM) |
| 71 | CSR ref. CSR ref. Less for difference in rates of materials : For stone metal : |
| 72 | iv Prime coat @ 0.85 kg per sqm. |
| 73 | 24.15 Tack coat @ 0.40 Kg per sqmt. |
| 74 | 24.16 (b) Surface dressing : |
| 75 | 24.24 Open graded pre mix surface : |
| 76 | 24.25 (b) Seal coat type B : |
| 77 | 24.28 (d) Carriage of materials : 5.2 (i) Earth, Surkhi, Sand, Earth, Fly Ash, Bajri,Ballast, Stone Boulders, Kankar and Building Rubbish, Earth. Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface) Crushed Bajri (12.5 / 13.2 mm ) : |
| 78 | Carriage of stone aggregate : (For Surface dressing & Open graded pre mix surface) Crushed Bajri (10.0 / 11.2 mm ) : |
| 79 | Coarse sand : Carriage of Coarse sand : (For seal coat type-B) |
| 80 | CSR Ref. CSR Ref. Less for difference in rates of materials : For stone metal |
| 81 | iii) Carriage of materials : 5.2 (iii) Tar,Bitumen and other Road Binders : 0.85 Carriage of Bitumen : Round the Trip lead is considered from Panipat Refinery. Sqm |
| 82 | ii Sub-Head-4:Construction of Main Pumping Station of capacity 45 MLD Earthwork excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A Depth upto 1.50 m.B.G.L. |
| 83 | i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a) |
| 84 | 6.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead. |
| 85 | 4.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash, Bajri, Ballast, Stone Boulders, kankar and Building Rubbish. |
| 86 | 2 nd and 3 rd chain,per chain of 30 meters |
| 87 | For subsequent chain per chain of 30 meters up to 0.50 km |
| 88 | C.C. 1:2:4 : |
| 89 | 10.13 a (ii) M-30 : |
| 90 | 10.17 M-25 : |
| 91 | 10.16 |
| 92 | 18.18 Shuttering |
| 93 | 9.3 PVC Foot Steps : |
| 94 | 29.35 Pump Chamber above GL |
| 95 | 10.22 Brickwork in CM.1:5 in first storey. :Panel Room Brickwall portion : |
| 96 | 11.4 (i) Plaster : |
| 97 | 15.9 White washing : |
| 98 | 16.3 Distempering (OBD) : Inside Painting : |
| 99 | 16.11 Exterior paint : |
| 100 | 16.14 Cement Concrete 1:2:4 gola : |
| 101 | 13.55 Top Khurra : |
| 102 | 13.45 Rain water pipes : |
| 103 | 13.74 Rain Water Pipe bend : |
| 104 | 13.75 (a) Rain Water Pipe coupling/socket : |
| 105 | 13.76 (a) 40 mm.Thick Grey Polished Floor : |
| 106 | 14.4 Plinth Protection |
| 107 | 14.1 Rolling Shutter : |
| 108 | 18.11 (a) Door & Windows |
| 109 | 17.45 (a) |
| 110 | 17.45 (b) |
| 111 | 17.46 (ii) |
| 112 | 17.47 |
| 113 | 18.3 Diff. rates of materials : |
| 114 | Carriage of Materials : 5.2 (i) Earth, Surkhi, Sand, earth, Fly Ash, Bajri, Ballast, Stone Boulders, Kankar and Building Rubbish, Earth |
| 115 | Sub-Head-5: Supply, laying, testing and commissioning of Pumping Main DI-K9 700 mm i/d pipeline from proposed MPS to 20 MLD STP Excavation : ( Manually) 28.1 Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earthwork upto 1.50 mt.Depth. |
| 116 | i Excavation : (Mech.) 28.2 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. (a) Earthwork upto 1.50 mt.Depth. |
| 117 | i DI K-9 Pipes : 28.7 B Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as perIS 8329 and laying the same in trenches to correct alignment and gradients, jointed withrubber tyton joints fitted complete including all cartage, cost of rubber ring. |
| 118 | (l) DI Specials : 28.25 Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the priorapproval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumencoating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc.Complete in all respects. |
| 119 | b D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. Pipe lines laid complete. |
| 120 | e Air Valve Concrete : |
| 121 | CSR Based |
| 122 | CSR based item Sub-Head-7: (i) DG Platform For Proposed Mps Excavation : |
| 123 | 6.19 CC 1:4:8: |
| 124 | 10.13 a (ii) |
| 125 | 11.6 Plaster : |
| 126 | 15.9 Sand filling |
| 127 | 14.107 M-25 : |
| 128 | 10.16 Steel : |
| 129 | 18.18 Diff.in Rates of materials : |
| 130 | Carriage of Materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth |
| 131 | (ii) Transformer Platform For Proposed Mps |
| 132 | 10.6(b)(ii) |
| 133 | 10.21 |
| 134 | 18.18 |
| 135 | 10.27 |
| 136 | 9.8 1.2 Meter High G.I.Barbed Wire fencing |
| 137 | 24.43 (a) |
| 138 | 16.17 |
| 139 | 18.6 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth |
| 140 | Lohand Khad 85 Km. |
| 141 | From Mirthal 192 km |
| 142 | From Mirthal 192 km |
| 143 | Difference in Rates of materials |
| 144 | (iii) DG Platform For Existing Mps (02 Nos) |
| 145 | 6.19 CC 1:4:8: 10.13 Cement concrete 1:4:8 a With stone ballast or shingle |
| 146 | 11.6 Plaster : |
| 147 | 15.9 Sand filling |
| 148 | 14.107 M-25 : |
| 149 | 10.16 Steel : |
| 150 | 18.18 Diff.in Rates of materials : |
| 151 | Carriage of Materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth |
| 152 | (iv) Transformer Platform For Existing Mps |
| 153 | 10.6(b)(ii) |
| 154 | 10.21 |
| 155 | 18.18 |
| 156 | 10.27 |
| 157 | 9.8 1.2 Meter High G.I.Barbed Wire fencing |
| 158 | 24.43 (a) |
| 159 | 16.17 |
| 160 | 18.6 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth |
| 161 | Lohand Khad 85 Km. |
| 162 | From Mirthal 192 km |
| 163 | From Mirthal 192 km |
| 164 | Difference in Rates of materials |
| 165 | (v) Construction of VCB Room Excavation : |
| 166 | 6.19 CC 1:4:8: 10.13 Cement concrete 1:4:8 a With stone ballast or shingle |
| 167 | 10.27 |
| 168 | 11.4 (i) |
| 169 | 15.9 M-25 : |
| 170 | 10.16 Flooring : 40 mm.Thick Grey Polished Floor : |
| 171 | 14.1 Floating Coat : |
| 172 | 14.4 Terracing : |
| 173 | 13.13 (i) |
| 174 | 13.55 Rain water pipe : |
| 175 | 13.74 Top Khurra : |
| 176 | 13.45 uPVC Pipe : 28.12 Providing and laying,jointing,fixing and testing ISI Marked uPVC Pipe Lines as per IS:4985-2000, including specias such as tees,bends,sockets,elbows etc. cutting,testing (including cost of specials) in the ground complete in all respects. B UPVC Pipe 10 Kgf/cm2 |
| 177 | b Upvc Bend : 13.75 Providing and fixing 110 mm. dia. U.P.V.C bend for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge. |
| 178 | (a) Upvc Coupling/socket : 13.76 Providing and fixing 110 mm. dia. U.P.V.C Coupling / Socket for Rain water pipe as per IS : 14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge. |
| 179 | (a) Door & Windows |
| 180 | 17.45 (a) |
| 181 | 17.45 (b) |
| 182 | 17.46 (ii) Rolling Shutter : |
| 183 | 18.11 (a) Steel : |
| 184 | 18.18 Shuttering : |
| 185 | 9.8 Distemper : |
| 186 | 16.1 Diff.in Rates of materials : |
| 187 | Carriage of Materials : 5.2 (i) Earth, Surkhi, Sand, earth, Fly Ash, Bajri, Ballast, Stone Boulders, Kankar and Building Rubbish, Earth |
| 188 | Capital Works 'CSR based Civil Items ( In Rs) 20867641.219999984 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 0.0535 1116418.8052699992 Total Capital Works Amount after adding 5.35% ( In Rs) 21984060.02526998 Capital Works Non CSR Items ( Part - A)- Civil Sub - Head -2 Re- Construction : (ii) Boundary wall Barbed wire fencing : 1.2 Meter High G.I.Barbed Wire fencing |
| 189 | (Rate analysis based on CSR item no.24.43 ) Sub-Head-4:Construction of Main Pumping Station of capacity 45 MLD Providing and Applying Food grade Epoxy based water proof coat : |
| 190 | Telengana CSR 2023 - 24 Buildings ( Part -III ) Sl.no.886 / TBSC - Q -VII -12 Sub-Head-5: Supply, laying, testing and commissioning of Pumping Main DI-K9 700 mm i/d pipeline from proposed MPS to 20 MLD STP Air Valve : PHED Rajasthan 2023Code no.6.6 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide-HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material,labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 191 | 6.6.1.6 Sub-Head-7: (ii) Transformer Platform For Proposed Mps |
| 192 | RUIDP SOR 20231330 (iv) Transformer Platform For Existing Mps |
| 193 | RUIDP SOR 20231330 Capital Works ' Non CSR based Civil Items ( In Rs) 749944.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 21984060.02526998 Non - CSR based amount ( In Rs) 749944.0 Sub-Total Part - A Sub Head (I) : CSR + Non CSR Amount : ( Rs) 22734004.02526998 MPS at Ferozpur Town (under AMRUT 2.0) Mechanical Works Sr.no CSR Item No Specification Unit Qty Total Rate(Rs) Rate (Rs. In Words) Amount (Rs) Mechanical Work: D.I.Specials : 28.25 Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects. |
| 194 | b CSR Items 851975.2000000001 Non Return Valve RUIDP 2023,19.52 Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as perIS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.6 |
| 195 | Non-Clog Submersible Pumping Set : RUIDP SOR 2023,18.1 Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Non clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M ,Shaft SS 410,mechanical seal with 10M Power & Control cable , 5M Galvanized Chain,,10M, 50mm MS galvanized Guide pipe, Duck Foot Bend, with Guide wire SS 304 etc. complete with all respect as per specification |
| 196 | D I Pipe RUIDP 2023,19.13 Providing, lowering, laying in trenches, aligning, fixing in position and double flanged (welded) centrifugally (spun) Ductile iron ISI marked K-9 grade pipes as per IS:8329-2000 (amended upto date), (including jointing and jointing material) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer.Note : E/w to be measured and paid separately. |
| 197 | Sluice Valve : RUIDP 2023,19.29 Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 1.6 |
| 198 | Manually Operated with gear Class PN 1.6 |
| 199 | Dismantling Joint RUIDP SOR 2023,19.56 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valve etc.) as per IS specification complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per technical specifications and as per direction of Engineer. |
| 200 | Sluice Gate : RUIDP 2017,18.7 Supply, Installation, Testing and Commissioning of CI Thimble Mounted Sluice Gate, Manually operated, Rising Spindle type. Sluice gates are as per IS 13349 Including all taxes, Freight, loading, unloading, fitting in position including Sluice gates are upward opening wall thimble mounted suitable for isolating the flow of sewer into out of the opening in the wall. It consists Gate frame, wall thimble, gate slide, shutter, seating/sealing faces .The gates will be provided with pads on sides, top and bottom to mount the wedges. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame & Shutter of CI Grade IS 210 FG 260, Head Stock assembly bolts & SS ASTM A276 Type 316, Stem, Operating Nut SS ASTM A276 Type 316., Duly tested for tensile strength, Tested for overall dimensions as per approved GA drawing complete in all respect as per specification and direction ofEngineer for following PEAK FLOW and depth up to 3M. |
| 201 | SS Manual Coarse Bar Screen ( 1.55 X 2.8 ) M NS Supply,fabrication,fixing and Testing of stainless steel (SS-304) Manual Coarse Bar Screen with flat bar 50 mm x 10 mm, spacing of bars 20 mm suitable for mounting in channel of specified size with inclination not more than 75 degree and a movable complete in all respect as per Technical specification,reputed make and the direction of the Engineer |
| 202 | RUIDP 2023,3815 G.I.Pipe : 40 mm.i/d. 28.36, Providing and laying,jointing,fixing,testing ISI Marked G.I.Pipe ( as per IS : 1239) B-Class premium make such as (approved make) including cost of specials such as tees,bends,sockets,elbow etc.cutting,threading and testing in trenches in the ground complete. |
| 203 | e CSR ITEMS AMOUNT (RS) 10771269.5615 AC Slip no.5 /02-03-2023 Add for GST Diff.betw.from 12% to 18% on CSR items amount : (Rs) 897555.8732000001 TOTAL Non CSR & CSR ITEMS 11668825.4347 Total in Lakh 116.688254347 Electrical, Instrumentation & RTU Works for Main Pumping Station of 20 MLD STP at Ferozepur Sr. No. Item No. Description Unit Qty Rate (Rs) Rate (Rs. In Words) Amount (Rs.) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: 1. Capital Works ' CSR based Items A. HT Cables & Accessories: 34.36 XLPE INSULATED HT CABLES: 34.36 A XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- |
| 204 | (viii) 34.36 C S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:- |
| 205 | (viii) B. LT Cables & Accessories: 34.10 A XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1) 1988 to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & first class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- |
| 206 | (xxx) 34.10 B XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 207 | (xvii) |
| 208 | (xxviii) |
| 209 | (xxx) |
| 210 | (xxxv) 34.25 CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 211 | (ii) 34.37 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: 34.37 B Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2 mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 212 | (iii) |
| 213 | (vi) 34.38 C Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections. |
| 214 | (iii) |
| 215 | (xii) 34.38 A Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 216 | (viii) |
| 217 | (x) C. Earthing: 34.13 (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. To make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). |
| 218 | (b) 34.13 (xv) Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 219 | 34.13 (xx) D. Wiring, Lighting & Accessories (for VCB Room, Pump House): 34.04 RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES : Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked reccessed in wall etc., complete with powder coated/anodised concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts ( socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20 Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3 mm.thick etc. PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1.5\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 220 | (i) b |
| 221 | (vi) 34.09 (xiii) Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 222 | (c.) 34.17 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with rovision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General Specifications including connections with suitable size of thimbles and bonding to existing earth etc. |
| 223 | (iii) 34.16 A MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10KA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 224 | (vi) 34.29 B Single Arm Brackets for GI Pipe Pole: (i) Supply and erection of GI pipe 40mm dia (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105 deg., the bracket should be fixed on top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect approved by Engineer- in -charge at site:- |
| 225 | (a) 34.31 3-STEPPED STEEL TUBULAR POLE: Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SPMpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:- |
| 226 | (i) 34.33 CEMENT CONCRETE MUFFS: (v) Making of cement concrete muff of overall size 450mmdia., suitable length (15cm below ground level) with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole/ GI pipe pole. The outer surface of the muff shall be finished with 1:2 cement plaster with two coats of white snowcem complete in all respect as approved and desired by the Engineer in- Charge at site:- |
| 227 | (a) 34.29 C SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE: (i) Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos.½\\" x 1½\\" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:- |
| 228 | (a) 34.12 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposesincluding bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 229 | (x) 34.33 (vii) Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 230 | (a) 34.09 (xii) Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexiblewire with copper conductor cable (ISI marked) confirm to IS:694/1990 left barein pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 231 | (d) Capital Works 'CSR based Electrical, Instrumentation & RTU Items (In Rs) 2058423.4500000007 0.0535 110125.65457500004 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works 'CSR based Electrical, Instrumentation & RTU Items after adding 5.35% (In Rs) 2168549.1045750007 2.Capital Works ' Non-CSR based Items A. HT System: |
| 232 | RUIDP ISOR 2023, 72.4 RUIDP ISOR 2023, 72.7 SITC of Indoor Type Floor mounted metal clad 11 KV, 630 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 622711,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification totally enclosed with Aluminium bus bar of 630 Amps for each phase, flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assambly of 3 vaccum interrupters (VCB manufacturer's own make) , with each pole individually encapsulated by epoxy insulations to make it dust proof and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker. interconnected with HT sleeve bus bar of 630 Amps , Basic Insulation level (BIL) : 28KV (RMS) / 75KV (Peak) and Altiude less than 1000 meters, including all protection, indication, Operation, monitoring and control and accessories etc. as required. Factory Tests of VCB panel as per System Integrator's QAP in it's own Manufacturing facility shall be witnessed by department Engineer virtually / Physically. (Cost of RCC Foundation / Steel Structure to be paid Extra). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 233 | RUIDP ISOR 2023, 72.7.2 |
| 234 | RUIDP ISOR 2023, 72.7.3 RUIDP ISOR 2023, 72.2 SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. |
| 235 | B. B. DG Set & AMF Panel: RUIDP ISOR 2023, 72.31 CPCB-IV complianced DG Sets |
| 236 | RUIDP ISOR 2023, 72.29 RUIDP ISOR 2023, 72.29 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 237 | C. C. LT Panel & Starter: |
| 238 | NS RUIDP ISOR 2023, 44.6 SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
| 239 | D. D. LT Cables & Accessories: RUIDP ISOR 2023, 60.4 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 Sq. mm (Ref: 60.4.2) |
| 240 | E. E. Earthing: RUIDP ISOR 2023, 63.5 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 241 | F. F. Wiring, Lighting & Accessories (for VCB Room, Pump House): RUIDP ISOR 2023, 66.4 Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in- charge. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Surface Mounting (Ref: 66.4.2) |
| 242 | RUIDP ISOR 2023, 67.11 RUIDP ISOR 2023, 67.11 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 243 | RUIDP ISOR 2023, 64.12 RUIDP ISOR 2023, 64.12 Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 244 | RUIDP ISOR 2023, 64.11 RUIDP ISOR 2023, 64.11 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 245 | RUIDP ISOR 2023, 67.12 RUIDP ISOR 2023, 67.12 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 246 | G. G. RTU, Pressure Gauge & Cables: RUIDP ISOR 2023, 43.12 Providing, Installation, Testing and Commissioning of Ultrasonic Level Transmitter : Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1% |
| 247 | RUIDP ISOR 2023, 47.12 |
| 248 | RUIDP ISOR 2023, 73.41 RUIDP ISOR 2022, E111500 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111540) |
| 249 | RUIDP ISOR 2022, E111400 RUIDP ISOR 2022, E111400 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111440) |
| 250 | Capital Works 'Non CSR based Electrical, Instrumentation & RTU Items (In Rs) 8419467.0 Total : Part - C (Electrical, Instrumentation & RTU) CSR + Non CSR Amount : (Rs) 10588016.104575 Electrical Works for Existing Main Pumping Station, Sewerage- Ferozepur Sr. No. Item No. Description Unit Qty Rate (Rs) Rate (Rs. In Words) Amount (Rs.) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: Re-installation of Electrical Items due to shifting of Existing Transformer & DG Sets: 1. Capital Works ' CSR based Items A. HT System for Transformer: 34.36 XLPE INSULATED HT CABLES: 34.36 A XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- |
| 251 | (v) 34.36 C S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:- |
| 252 | (iii) |
| 253 | (vii) B. LT Cables & Accessories for Transformer & DG Sets: 34.10 A XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1) 1988 to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & first class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- |
| 254 | (xxvii) |
| 255 | (xxx) 34.10 B XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 256 | (xxvii) |
| 257 | (xxx) 34.25 CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 258 | (ii) 34.37 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: 34.37 B Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2 mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 259 | (iii) |
| 260 | (v) 34.38 C Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections. |
| 261 | (xii) 34.38 A Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 262 | (vii) |
| 263 | (x) C. Earthing for Transformer & DG Sets: 34.13 (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. To make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). |
| 264 | (b) Capital Works 'CSR based Electrical Items (In Rs) 945184.3999999999 0.0535 50567.365399999995 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works 'CSR based Electrical Items after adding 5.35% (In Rs) 995751.7653999999 2.Capital Works ' Non-CSR based Items A. HT System for Transformer: |
| 265 | RUIDP ISOR 2023, 72.4 C. Earthing for Transformer & DG Sets: RUIDP ISOR 2023, 63.5 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 266 | D. D. Dismantling & Re-installation Work: |
| 267 | NS Capital Works 'Non CSR based Electrical Items (In Rs) 190518.0 Total : Part - C (Electrical) CSR + Non CSR Amount : (Rs) 1186269.7654 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender