Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56744996

Tender For Special Repair To Fire Fighting System Of Md Accn No. P-18, P-19, P-104, P-103 & P-94 At Ahrr Under Ge E/M R&R Hospital Delhi Cantt-10.

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
81.45 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
13 days left
EMD
1.47 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair To Fire Fighting System Of Md Accn No. P-18, P-19, P-104, P-103 & P-94 At Ahrr Under Ge E/M R&R Hospital Delhi Cantt-10.

BOQ

Name of Work:- SPECIAL REPAIR TO FIRE FIGHTING SYSTEM OF MD ACCN NO. P-18, P-19, P-104, P-103 & P-94 AT AHRR UNDER GE E/M R&R HOSPITAL DELHI CANTT-10.
Sl. No. Item Description
1Excavation in trenches in any kind of soil not exceeding 1.5 metre deep and not exceeding 1.5 metre wide for laying of pipes in trenches and getting out, complete all as specified & directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, after laying of pipeline complete all as specified & directed.
3Removing excavated surplus material to a distance not exceeding 50 metres and depositing where directed, at a level not exceeding 1.5 metre above the starting point, complete all as specified & directed.
4M&L for road cutting of average size 0.40m x 0.60 m for laying of any type of pipe, incl excavation, returning filling in, spreading, levelling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix capeting 25mm thick using ready mix patch repair work and make good complete all as specified & directed.
5Supply, installation, testing and commissioning, in replacement, of oblique type hydrant valve made of stainless steel, ISI marked, 75mm NB flange inlet, single way outlet type with hose coupling adaptor of 63 mm size, instantaneous spring lock arrangement and blank cap with chain, conforming to IS 5290, type 'A', suitable for hydraulic pressure of 21 kgf/cm2 incl pipe line of existing size / type incl welding, cutting, threading, screwing, making all connection for smooth functioning complete all as directed.
6Supply, installation & testing and commissioning in replacement of yard hydrant valve made of stainless steel, ISI marked, 75mm NB flange inlet, single way outlet type with hose coupling adaptor of 63 mm size, instantaneous spring lock arrangement and blank cap with chain, conforming to IS 5290, type 'A', suitable for hydraulic pressure of 21 kgf/cm2 incl MS pipe line of size 80 mm upto 1.5 mtr height incl MS flanged both ends making all connection for smooth functioning complete all as directed.
7S&F in replacement of hose box made of 18 gauge MS sheet 800mmx600mmx250mm with double door locking arrangement in front with 4mm thick glass and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside making good surface and making arrangement for 2 hose pipe inside the box incl 65 mm pad lock complete all as specified.
8S&F in replacement of Reinforced rubber lined fire hose pipe as per IS 636, type 'A', ISI marked, 63 mm nominal internal dia, 15 M long each, duly fitted with stainless steel coupling of 63 mm size, ISI marked with multi serrated tail and double instantaneous spring lock arrangement comprising of male half at one end and female half at other end complete with rubber cup washer and conforming to IS 903, suitable for hydraulic pressure of 21 kgf/cm2, complete all as directed.
9S&F in replacement of short branch pipe nozzle, made of gun metal, ISI marked, instantaneous pattern type to suit fire hose delivery coupling of 63 mm size complete with stainless steel nozzle of 15 mm nominal size conforming to IS 903, suitable for hydraulic pressure of 21 kgf/cm2, complete all as directed.
10Supply and fix in replacement of first aid hose reel with drum of 20 mm dia and 30 mtr length including branch nozzle conforming to IS-884 complete all as directed.
11Supply and Fixing Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. by taking down old frame complete all as specified and as directed.
12S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. by taking down old frame complete all as specified
13S&F Sheet glass, ordinary quality 5 mm thick and glazing in aluminium shutter exc 0.5 sq. m in each pane, by taking down old glass complete all as specified an as directed
14S&F Aluminium alloy, anodised, sliding door bolt,300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
15S & F aluminium anodised barrel tower bolt 200mm long.
16Supply and fix fire brigade valve connection 4 way incl MS pipe line of 100 mm size upto 1.5 mtr size making all connection for smooth functioning complete all as directed.
17Supply and fix fire brigade valve connection 2 way incl MS pipe line of 100 mm size upto 1.5 mtr size making all connection for smooth functioning complete all as directed.
18Supply and fix pressure gauge 100 mm dia ball valve of pressure 0 to 21 Kg/Sqcm with SS syphon pipe 'U' type and control valve complete all as directed. Make :- H-Guru/Fiebig/Wika.
19S&F stop valves , cast copper alloy, screwed down , high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed suitable for 25 mm bore complete all as directed.
20Taking out old MS ERW pipe 200 mm bore, laid in trenches, header, under the roads or fixed on walls, with and including all old fittings and connections, complete all as directed.
21All as per item No 20 here-in-before but for pipe of size150 mm bore.
22All as per item No 20 here-in-before but for pipe of size100 mm bore.
23All as per item No 20 here-in-before but for pipe of size 80 mm bore.
24All as per item No 20 here-in-before but for pipe of size 25 mm bore. Please Enable Macros to View BoQ information
25All as per item No 20 here-in-before but for pipe of size 25 mm bore. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56744996
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 81.45 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Fire Fighting System Of Md Accn No. P-18, P-19, P-104, P-103 & P-94 At Ahrr Under Ge E/M R&R Hospital Delhi Cantt-10.
Basic Detail
Tender No CWE-ND/T-36/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 30 Jul 2026
Submission Date 27 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value 81.45 Lakhs
Tender Fee 1000
EMD 1.47 Lakhs
Exemption Not Available
Document List
83979df6-fa78-415d-9e59-f5171f06e1cc.html
BOQ_875775.xls
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

83979df6-fa78-415d-9e59-f5171f06e1cc.html

xls

BOQ_875775.xls

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders