Tender For Labour Charges For Operation And Maintenance Of Thiruvanthipuram Head Works And Capper Hills Head Works Including All Ohts , Attending And Repairing Of Water Supply Pumping Mains And Distribution Mains At Ward No.1 To 45 And Mainteance Of
Tender Overview
Project Description
Tender for Labour Charges For Operation And Maintenance Of Thiruvanthipuram Head Works And Capper Hills Head Works Including All Ohts , Attending And Repairing Of Water Supply Pumping Mains And Distribution Mains At Ward No.1 To 45 And Mainteance Of Attending And Repairing Of Different Type Of Pumpsets At All Head Works In Cuddalore Corporation (3Months)
BOQ
| Sl. No. | Item Description |
| 1 | Labour charges for Operation and maintenance of Thiruvanthipuram head works and Capper hills Head works including All OHT's for the period of ( 3 months ) in Cuddalore Corporation |
| 2 | Labour charges for Operation and maintenance of Thiruvanthipuram head works and Capper hills Head works including All OHT's in Cuddalore Corporation. The contractor should submit the attendance register, esi,pf certificate and salary paid certificate. The oht operator should clean the boundary area of the OHT Premises. The head works operator should clean the Boundary area of the head works premises.The Filter Bed mainteance assistant should clean the filter bed periodically. |
| 3 | Electrician Helper SOR 25-26pg.no.12 (4Nos.) |
| 4 | Electrician Helper SOR 25-26pg.no.16 (4Nos) |
| 5 | Mazdoor Category - II SOR 25-26pg.no.16 |
| 6 | All OHT and sump washout Labours Un Skilled Labour Mazdoor Category - II (2/ 3Nos x3monthx1times) |
| 7 | Mainteance of Attending and repairing of Different type of pumpsets at All Head works in cuddalore Corporation (3Months period) |
| 8 | Labour charges for the removal of submersible pumpset in borewell/openwell for attending repair.including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days-For repairing of pumpset. |
| 9 | Above 10.00 HP to 35.00 HP |
| 10 | Attending and repairing of Rewinding the burnt out coil to the following HP borewell type submersible motor with suitable insulated submersible copper induction wire and count including cost of coil wire and 30 days trail run (The retrived burnt out coil should be taken back by contractor) |
| 11 | For borewell type-35HP Headhouse |
| 12 | For borewell type-30HP Headhouse |
| 13 | For borewell type-25HP Headhouse |
| 14 | For borewell type-20HP Headhouse |
| 15 | For openwell type-12.5HP sump |
| 16 | Repairing and Reconditioning of following HP borewell submersible motor.includingall cost of materials such as Replacement of new thrust Bearing,shaft ,bushes,maching and labour cost etc.including all cost of materials,labours,etc.., complete as directed by the departmental officers. |
| 17 | For borewell type-35HP Headhouse |
| 18 | For borewell type-25HP Headhouse |
| 19 | For borewell type-20HP Headhouse |
| 20 | For Openwell type-30HP Headhouse |
| 21 | For Openwell type-12.5HP Sump |
| 22 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days-For Newly purchased pumpset. |
| 23 | Above 7.5 HP to 20 HP sump |
| 24 | Above 20HP to 30 HP borewell |
| 25 | Above 30 HP to 40 HP borewell |
| 26 | Attending and repairing of water supply pumping mains and distribution mains at ward No.1 to 45 and all Head works in cuddalore Corporation in cuddalore Corporation.( 3 Month Period) |
| 27 | Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B ( For leak purpose 5times rate will be multiplied including refilling ) (5times*205.84=1029.2Rs) |
| 28 | Removing the burst C.I/D.I pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.-For depth upto 2m TWAD 2024-25 PAGE NO:178 |
| 29 | 150mm dia C.I pipes |
| 30 | 200mm dia C.I pipes |
| 31 | 250mm dia C.I pipes |
| 32 | 300mm dia C.I pipes |
| 33 | 350mm dia C.I pipes |
| 34 | 400mm dia C.I pipes |
| 35 | 450mm dia C.I pipes |
| 36 | Removing the burst AC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.-For depth upto 2m |
| 37 | 200mm dia AC pipes |
| 38 | 250mm dia AC pipes |
| 39 | 300mm dia AC pipes |
| 40 | 350mm dia AC pipes |
| 41 | 400mm dia AC pipes |
| 42 | 450mm dia AC pipes |
| 43 | Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers |
| 44 | 75mm dia (OD) PVC Pipes |
| 45 | 90mm dia (OD) PVC Pipes |
| 46 | 110mm dia (OD) PVC Pipes |
| 47 | 125mm dia (OD) PVC Pipes |
| 48 | 140mm dia to 160mm dia (OD) PVC Pipes |
| 49 | Lowering CI collars with flange into the trench and laying to proper grade and alignment and jointing PSC pipes with 2 Nos of conical rubber rings and MS bolts and nuts excluding the cost of jointingf materials. For depth upto 2m |
| 50 | Upto 350mm dia meter pipe |
| 51 | Supply and delivery of folowing dia 6KSC unplasticized PVC pipes for portable water supply works as per IS 4985/2000.including all cost of materials and labour charges etc.., complete as directed by the departmental officers. |
| 52 | 75mm dia (OD) PVC Pipes |
| 53 | 90mm dia (OD) PVC Pipes |
| 54 | 110mm dia (OD) PVC Pipes |
| 55 | 140mm (OD) PVC Pipes |
| 56 | Supply and delivery of following size Leak Arresting Flexible SS Clamps of Wrap Around Single Section type upto 500 mm diameter and Maxi Range double section type beyond 500 mm od of all rigid pipe sections. The Clamps made of mild steel 6mm thick joint portion made with 2 Nos.6mm thick Equal angle.Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack.ecessary drilling arrangements to insert the MS bolt and nuts.including all cost ofmaterialssuchasMSpipe,Equalangle,welding,cutting,grinding,finishing,conveyance,labours,etc..,complete as directed by the departmental officers. |
| 57 | 200mm dia |
| 58 | 250mm dia |
| 59 | 300mm dia |
| 60 | 350mm dia |
| 61 | 400mm dia |
| 62 | GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender