Tender For Renovation And Upgradation Of Residential Colony At Balasore Under Odisha State Office
Tender Value
4.98 Crore
Estimated cost
Bid Submission
13 Aug 2026
9 days left
EMD
1.25 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation And Upgradation Of Residential Colony At Balasore Under Odisha State Office
BOQ
| Sl. No. | Item Description |
| 1 | DEMOLISHING WORK |
| 2 | Demolishing brick work (all type) manually or by mechanical means including stacking of serviceable material at desired location within the IOCL premises and disposal of unserviceable material (as identified by IOCL) outside the IOCL premises at unobjectionable place (outside municipal limits / boundaries) as per direction of Engineer-in-charge. If any statutory approval required then vendor should take the same with no extra cost to IOCL. |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge. |
| 4 | Dismantling the existing PCC/flooring/Kota stone/mosaic/tiling work/Granite (all type) and disposal of unserviceable material (as identified by IOCL) outside the IOCL premises at unobjectionable place (outside municipal limit /boundaries) as per direction of Engineer-in-charge.If any statutory approval required then vendor should take the same with no extra cost to IOCL. |
| 5 | Dismantling the existing Wall Plaster/ wall Tile (all type) including cleaning the surface for further work of plastering / tiling and disposal of unserviceable material (as identified by IOCL) outside the IOCL premises at unobjectionable place (outside municipal limits / boundaries) as per direction of Engineer-in-charge.If any statutory approval required then vendor should take the same with no extra cost to IOCL. |
| 6 | Dismantling the existing wooden / Gypsum / aluminum / Glass etc. i.e. all type of Panel / Partition / Door / Window / fixed glazing / false ceiling etc. including stacking of serviceable material at desired location within the IOCL premises and disposal of unserviceable material (as identified by IOCL) outside the IOCL premises at unobjectionable place (outside municipal limits / boundaries) as per direction of Engineer-in-charge.If any statutory approval required then vendor should take the same with no extra cost to IOCL. |
| 7 | Dismantling Metal pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within premises as per direction of Engineer-in-charge : |
| 8 | Disconnecting, dismantling the existing GI/CI/PVC/CPVC etc. pipeline item including dismantling sinks, wash basins, WCs, Urinals, Taps, etc. and including stacking of serviceable material at desired location within the IOCL premises and disposal of unserviceable material (as identified by IOCL) outside the IOCL premises at unobjectionable place (outside municipal limits / boundaries) as per direction of Engineer-in-charge. If any statutory approval required for the disposal of the same outside from IOCL premises then vendor should take the necessary approval from statutory agencies with no extra cost to IOCL. |
| 9 | Demolishing C.C. / R.C.C. work (all type) manually or by mechanical means including stacking of serviceable material such as reinforcement, etc. at desired location within the IOCL premises and disposal of unserviceable material (as identified by IOCL) outside IOCL premises at unobjectionable place (outside municipal limits / boundaries) as per direction of Engineer-in-charge.If any statutory approval required then vendor should take the same with no extra cost to IOCL. |
| 10 | Demolishing/Chipping carefully the loose concrete of distressed Structural member (columns, beams, slabs,Chajjas, Pardi etc) without damaging existing strong concrete by means of sharp chissle which should tempered regularly or high frequency low impact hammers to be used, cleaning the surface by water jet pressure pump at 4 to 5 kg/ sqcm pressure to remove chlorides and loose particles, air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damaged area of member / concrete will be measured, Avg thickness upto 10-100 mm) etc. complete. The dismantled materials are to be stacked in gunny Bags and removed from site. If any approval for Dumping/disposal of the same is required from BM , it shall be in scope of bidder. |
| 11 | Removing existing commode/Wash Basins and disposing off the material to an unobnectionable place as directed by Engineer-In-Charge.The item also includes dismantled materials shall be disposed off by the contractor (in area designated by BM) and neccesary approval required for the same shall be in the scope of Contractor. |
| 12 | DISMANTLING Dismantling of following electrical fittings / fixtures with all leads and lifts.Disconnecting, dismantling the existing Light Fixture, Electrical points, CONNECTING cables of any size, wiring, etc including stacking of serviceable material at desired location within the IOCL premises and disposal of unserviceable material (as identified by IOCL) outside the IOCL premises at unobjectionable place (outside municipal limits / boundaries) as per direction of Engineer-in-charge.If any statutory approval required then vendor should take the same with no extra cost to IOCL. |
| 13 | Electrical cables of all sizes from under / above ground position |
| 14 | DPS board all types with/ without stand |
| 15 | 5 to 15A switches/MCBs/plugs |
| 16 | 32/63/100A DP/TPN switches/ MCCBs /MCBs |
| 17 | Flourescent tube light fittings of all sizes |
| 18 | BUILDING INSIDE & OUTSIDE WORK |
| 19 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees & saplings of girth upto 30cm measured at a height of 1m above ground level and removal of rubbish outside the site and to an unobjectionable place. |
| 20 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 21 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. All kinds of Soil |
| 22 | Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : |
| 23 | Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : Plain Cement Concrete 1:3:6 (1-Cement: 3-Coarse sand: 6-Coarse aggregate) using 20mm nominal size graded aggregates. |
| 24 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 25 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:Plain Cement Concrete 1:3:6 (1-Cement: 3-Coarse sand: 6-Coarse aggregate) using 20mm nominal size graded aggregates. |
| 26 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: PCC 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 27 | Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : |
| 28 | Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 20mm |
| 29 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 30 | Half brick masonry with Class designation 5.0 bricks in Cement mortar 1:4 ( 1 cement : 4 coarse sand) IN superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL |
| 31 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in: |
| 32 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in 1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 33 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 34 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth-Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 35 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 36 | Providing & applying 12mm thick CM 1:4 (1Cement: 4Coarse sand) cement plaster for walls, columns, beams etc. Including chipping concrete surface, finishing, scaffolding, curing, etc, complete up to floor V levels. |
| 37 | Providing and laying cement plaster on surfaces with fine sand including curing etc 20mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 38 | Providing and fixing 150 mm wide Chicken Wire mesh between junctions of column/beam and walls, fixed with U nails 150 mm centre to centre before plastering the junction etc. complete in all respects. |
| 39 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) |
| 40 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 41 | RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 42 | RCC 1 Cement :2 Coarse Sand: 4 Graded Stone Aggregate 20mm |
| 43 | Providing & laying factory made Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih strong vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881 maximum dimensional deviations of +/- 3mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. |
| 44 | ii) M40 grade 80 mm thick Plain finish |
| 45 | Taking out existing CC interlocking paver blocks from footpath central verge, including removal of rubbish etc., disposal of unserviceable material out of site serviceable material within 50 metre lead as per direction of Engineer - in-Charge |
| 46 | Laying Corporation supplied interlocking paver blocks of any design /shape laid in required line,level,curvature,colour & pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as/ direction of Engineer-in-charge. |
| 47 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design,With Common burnt clay bricks of class designation 75 |
| 48 | Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 49 | Constructing masonry Chamber 90x90x100 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice valves etc, with CI surface box 100 mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design: With Common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 50 | M.S. STEEL PROPS:-Providing and fixing in vertical position telescopic M.S.prop under deflected beam/lintel/slab/chajjas by using teak wood battens of size 1000 x 80 x 80 for packing between prop plate and the beam/lintel/slab/chajjas bottom surface as per the directions of engineer-in-charge.Mode of measurement : Per number of uses shall be recorded for measurement. After completion of work, it shall be property of contractor. |
| 51 | Temporary Protection to Flooring:-Laying POP for Floor protection & later Removing & Cleaning, Complete.The item includes laying of plastic sheet of any thickness on floor to be protected and over this sheet 10-15 mm POP shall be applied.This protection is to be retained till completion of works in the flat so as to prevent damage to the flooring and removing the same after completion of work.Any damage to the tiles/floor shall be responsibility of contractor and same shall be rectified/replaced with new tile. |
| 52 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 53 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 54 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters,sills,facias, and & similar locations of required size of shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement mixed with matching pigment,epoxy touch ups, including rubbing,curing moulding & polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade having Area of slab upto 0.50 sqm |
| 55 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters,sills,facias,Stair & similar locations of required size of shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement mixed with matching pigment,epoxy touch ups, including rubbing,curing moulding & polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade having Area of slab over 0.50 sqm |
| 56 | Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge. |
| 57 | Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge.(Marble work) |
| 58 | Extra for providing edge moulding to 18mm Granite/ marble stone counters,Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge.(Granite Work) |
| 59 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters & similar location in marble/Granite/stone work including necessary holes for pillar taps etc.including rubbing and polishing of cut edges etc.complete |
| 60 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified |
| 61 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified- Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 62 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. |
| 63 | Providing and applying two or more coats of machine polishing to existing mosaic/marble/kota tiles/Granite with tin oxide and wax polishing to get maximum shine to the flooring. |
| 64 | 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 65 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 66 | Foundations,footings,bases of column |
| 67 | Retaining/return wall, wall (any Thickness) including attached pilaster buttresses, plinth & string courses, fillets, kerbs&steps etc |
| 68 | Columns, piers, abutment, pillars,posts & struts |
| 69 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty |
| 70 | 150 mm dia. R.C.C. pipe |
| 71 | 250 mm dia. R.C.C. pipe |
| 72 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position andbinding all completeat all levels |
| 73 | Thermo Mechanically Treated Bars of Fe- 500D grade or more,conforming to IS1786 |
| 74 | Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth andstring courses, fillets, columns, pillars, piers, abutments, posts andstruts etc. above plinth level UP TO FLOOR V LEVEL excluding cost ofcentering, shuttering,finishing and reinforcement |
| 75 | RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 76 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies,terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster & finally finishing surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order & as directed and specified by the Engineer-in-Charge : with average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 77 | Providing & laying water proofing treatment in sunken portion of WCs, bathroom etc. by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment & sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 78 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 79 | Providing and injecting chemical emulsion antitermite treatmen & creating a chemical barrier t as per IS : 6313 (Part-III) by treating the bottom surface,under & aroundcolumn pits, wall trenches, basement excavation, top surface plinthfilling, junction of wall and floor, along external perimeter ofbuilding, expansion joints, surrounding of pipes & conduits etc. the sides of excavat ion, backfill in immediate contact with foundation, treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate of 0.5% of chloropyrifos or equivalent per square metre of surface area covering and directed by PMC/ IOCL. |
| 80 | Stone flooring with 18mm thick Marble/Granite stone (sample of stone shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry including rubbing and polishing complete.Granite stone/Makrana White second quality in flooring |
| 81 | Carriage charge for disposal of earth by mechanical means, including loading, transporting, stacking, unloading to approved municipal dumping ground / unobjectionable place as per direction of Engineer- in-Charge beyond IOCL Premises for all leads and including all lifts. |
| 82 | Distance > 1 km< 3 km |
| 83 | Distance > 3 km< 5 km |
| 84 | Distance > 5 km< 10 km |
| 85 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'X' shaped placed 3.00 m apart and with 5 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) /Spring core (2.5mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 86 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 87 | Providing & fixing MS grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.including priming coat with approved steel primer (fixed to steel windows by welding) all complete. |
| 88 | Dismantling Steel work in built up sections in angles, tees, flats channels etc. including all gusset plates, bolts nuts, cutting rivets welding etc. including dismembering and stacking within premises |
| 89 | Fabrication & Erection of IOC supplied structural steel work riveted, bolted or welded in single/ built up sections,trusses & framed work hoisting, fixing in position and applying a priming coat of approved steel primer all including cutting, complete |
| 90 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover |
| 91 | Supply, installation and fixing of 316-grade stainless steel 3.0 mm Grills of any size on windows/Balcony. The required fasteners/any othe assembly required shall be in scope of bidder. Finshed area shall be considered for measurement.The distance between two vertical ropes (ss wire) should not be more than 50 mm. |
| 92 | Providing and fixing Stainless steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting( fitting shall be paid separately) including fixing of the pipe with clamps at 1.00m spacing including cutting and making good the walls including testing of joints complete as/direction of Engineer in charge.(pipe length inserted in the fitting shall not be measured for payment) Exposed on walls or concealed in walls /others |
| 93 | railing pipe-P/F 28.58MM OD SS PIPE |
| 94 | railing pipe-P/F 48.60MM OD SS PIPE |
| 95 | railing pipe-P/F 15.88MM OD SS PIPE AISI 304 |
| 96 | Providing and laying class-B 50mm dia GI pipe |
| 97 | PAINTING WORK |
| 98 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 99 | Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 100 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 101 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 102 | Finishing with Epoxy paint, 2 or more coats at all locations on steel work prepared & applied as per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. |
| 103 | Finishing with Epoxy paint, 2 or more coats at all location on concrete work prepared & applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. |
| 104 | Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution |
| 105 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 106 | Lettering with black japan paint of approved brand & manufacture and (unit/letter/cm ht) |
| 107 | Door, Window, Kitchen modular Works |
| 108 | Providing & fixing ISI mark flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains/cross bands & face veneers on both faces of shutters |
| 109 | Providing & fixing ISI mark flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains/cross bands & face veneers on both faces of shutters i) 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 110 | WindowsProviding and fixing pristine white finish UPVC doors & windows as per drawings provided by vendor only. Company must have own production facilities (extrusion & fabrication) & controlthe entire cycle from Extrusion toInstallation to Post Sales Service in India or as per detail drawing and to the satisfication of the Architect/PMC/IOC.Wall thickness of profile must be min 1.8±0.3mm, which shall bemanufactured from tropicalized Blend with TiO2 and required additives.The profile sections should have multihollow (min 2 to 3 chambers)chamber to include GI reinforcement with 120 GSM zinc coated, fitted incontinuouslength, in closed chamber. The thickness of GI should beselected to meet the wind load requirement as per IS 875 - Part III onsash / mullion. Supplier should be submitting wind load calculation &validation complying with IS 875 - Part III before material supply.Minimum steel reinforcement hickness should be 1.2 mm to 2.5mm. UPVCWindows & Doors must be fabricatedwith fusion welded corners & mustconform to the strengthrequirements based on wind load as per IS 875 -Part III. All hardware fitted must be of SS, except handles to beofZinc / Al. alloy casted with powder coated. UPVC windows & doors must beinstalled by profile manufacturer only.There would be Warranty of 10 Years on profile and 1 Year on hardwarefrom the date of installation.Providing and fixing Pristine white 3 Track two glass panels one fibermesh panel combination slidingwindows having movable panel made ofouter frame of about 170mm x 58mm & sash 45mm x 90mm. All having wall thicknessof min1.8+-0.3mm with EPDM/TPE Gasket, wool pile with rollers, GIfastners for fixing frame to finalized wall andnecessary stainlesssteel screws etc. & Glass should be DG INS TGH - 24mm Clear DGU ( 6mmToughened glass + 12mm AG+ 6mm Toughened glass) of any size of window complete system as per approved design & drawing and specified intechnical specification, scope of work and directed by PMC/IOCL.\\" Architectural Drawings and working drawing to be provided by Vendor only before start of work, No extra cost for drawings borne by IOCL, Item rate is including provision of submission of drawing to IOCL/PMC before start of work. |
| 111 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length |
| 112 | i) Second class teak wood |
| 113 | ii) Sal wood |
| 114 | Providing & fixing ISI mark flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains/cross bands & face veneers on both faces of shutters |
| 115 | iii) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws |
| 116 | Providing & fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked with one side decorative & other side balancing lamination Grade I, Type II exterior grade IS :12823 marked in shelves with all necessary screws and fittings wherever required, edges to be painted with polyurethane primer |
| 117 | i) 18 mm thick |
| 118 | Providing and fixing panelling or panelling and glazing in panelled or panelled & glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 119 | ii) 12mm thick particle board with Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS:3097, Grade I |
| 120 | Extra for providing lipping with 2nd class teak wood battens 30mm minimum depth on all edges of flush door shutters (over all area of door shutters to be measured) |
| 121 | KITCHEN OVER HEAD MODULAR GLASS CABINET - Providing, making & assembling Kitchen Over head Modular Cabinet of about 2050 x 700 x 350 mm in depth as per architectural drawing and vendors specifications & instructions. Necessary Architectural and working drawing to be provided by Vendor only with no extra cost to IOCL. Item rates are including provision of submission of architectural and working drawing before start of the work by Vendor to IOCL/PMC. The system shall be comprising of following.Ply Boxing - Providing, making and fixing 18mm thick marine prelaminated ply (IS 710) boxing work with provision for fixing the chimney/ Aquaguard as per architectural drawing & instructions. Storage back shall be of 12mm thick marine prelaminated ply (IS 710) as per drawing. Shutters- Providing & making 2 nos. storage partly glazed shutters (450 x 700 mm in size) made out 25mm thick marine approved color prelaminated ply (IS 710). p/f 8mm thick frosted glass (about 350 x 600 mm in size) in the shutter and 1 no shutter (about 450 X 700 mm in size). Providing & making 1 no top hung about 700 x 700 mm in size) made out 25mm thick approved color marine prelaminated ply (IS 710) and hung the shutter to the ply boxing with heavy duty ss hinges as per drawings and 18 mm thick marine prelaminated ply (IS 710) boxing above the storage area for chimney ducting. Rate also included providing, making & fixing 1 no .20mm thick fixed shelves (about 100 x 350mm in size) made of 18mm approved color marine prelaminated ply including approved profile ss handle of approved make, hardware and fittings of approved make, p/f 2mm thick matching pvc beading, mouldings, lipping, providing & fixing hardware fittings, finishing and cleaning etc. completed as per vendors specifications and instructions of the PMC/IOCL officials. Hardware fittings & Fixtures-a) SS reversible/ Auto loaded Hinges 3 nosb) Magnetic catch- 2 nos. |
| 122 | KITCHEN OVER HEAD MODULAR CABINET - Providing, making & assembling Kitchen Over head Modular Cabinet about 2350 x 1200 x 350 mm in depth as per architectural drawing and Vendor specifications & instructions. Necessary Architectural and working drawing to be provided by Vendor only with no extra cost to IOCL. Item rates are including provision of submission of architectural and working drawing before start of the work by Vendor to IOCL/PMC.The system shall be comprising of following.Ply Boxing - Providing, making and fixing 18mm thick approved color prelaminated marine ply boxing work as per architectural drawing & instructions. Storage back shall be of 12mm thick approved color marine prelamianted ply (IS 710) as per drawing. Shutters- Providing & making 5 nos. storage shutters (about 450 x 1200 mm in size) made out 25mm thick marine approved color prelaminated ply (IS 710) and hung the shutter to the ply boxing with heavy duty ss hinges as per approved make and as per drawings. Rate also included providing, making & fixing 20mm thick fixed shelves made of approved color prelaminated marine ply including approved profile ss handle of approved make, hardware and fittings of approved make, p/f 2mm thick matching pvc beading, mouldings, lipping, providing & fixing hardware fittings, finishing and cleaning etc. completed as per vendors specifications and instruction of the PMC/IOCL officialsHardware fittings & Fixtures-a) SS reversible/ Auto loaded Hinges 5 nos.b) Magnetic catch- 5 nos. |
| 123 | KITCHEN OVER HEAD MODULAR CABINET - Providing, making & assembling Kitchen Over head Modular Cabinet about 2350 x 700 x 600 mm in depth as per architectural drawing and Vendor specifications & instructions. Necessary Architectural and working drawing to be provided by Vendor only with no extra cost to IOCL. Item rates are including provision of submission of architectural and working drawing before start of the work by Vendor to IOCL/PMC. The system shall be comprising of following.Ply Boxing - Providing, making and fixing 18mm thick approved color prelaminated marine ply boxing work as per architectural drawing & instructions. Storage back shall be of 12mm thick approved color marine prelamianted ply (IS 710) as per drawing. Shutters- Providing & making 5 nos. storage shutters (about 450 x 700 mm in size) made out 25mm thick marine approved color prelaminated ply (IS 710) and hung the shutter to the ply boxing with heavy duty ss hinges as per approved make and as per drawings. Rate also included providing, making & fixing 20mm thick boxing at the bottom (wherever lofts are not available) made of approved color prelaminated marine ply including approved profile ss handle of approved make, hardware and fittings of approved make, p/f 2mm thick matching pvc beading, mouldings, lipping, providing & fixing hardware fittings, finishing and cleaning etc. completed as per vendors specifications and instruction of the PMC/IOCL officialsHardware fittings & Fixtures-a) SS reversible/ Auto loaded Hinges 5 nos.b) Magnetic catch- 5 nos. |
| 124 | Removing of existing shutters / storage units / trolleys / drawers and storage spaces all complete and Providing and fixing in position 25mm thick Shutters/ Trolley Facia below platform made of 25mm thick approved color marine prelaminated ply. Shutter shall be fixed on marine approved prelaminated ply frame ( 50 x 25mm in size) and SS Trolley as per drawing including providing wall necessary consumables, necessary hardware, p/f 2mm thick matching pvc beading, molding, lipping, SS reversible hinges, ss profile handle and as per specification & instructions of the PMC/IOCL. Excluding the cost of the SS Trollies. |
| 125 | Providing and fixing SS 304 Kitchen Accessories/ Trolleys with soft closures as per drawing and vendor specifications & instructions as belows including cutting welding/ soldring, grinding, necessary ss frame work, polishing/buffing, necessary hardware, drilling, p/f hafale hardware fittings, finishing and cleaning etc. completed as per specification & direction of the PMC/IOCL officials. Size of SS Trolley about 700 X 150 X 350 mm deep |
| 126 | Providing and fixing SS 304 Kitchen Trolleys with soft closures SS Trolley as per drawing and specifications & instructions as bellows including cutting welding/ soldering, grinding, necessary ss frame work, polishing/buffing, necessary hardware, drilling, p/f hafale hardware fittings, finishing and cleaning etc. completed as per specification and direction of the PMC/IOCL.Size of SS Trolley about 700x 300 x 350 mm deep |
| 127 | Providing and fixing SS 304 Kitchen Trolleys (oil Pull) with soft closures SS Trolley as per drawing and specifications & instructions as bellows including cutting welding/ soldering, grinding, necessary ss frame work, polishing/buffing, necessary hardware, drilling, p/f hafale hardware fittings, finishing and cleaning etc. completed as per specification and direction of the PMC/IOCL.Size of SS Trolley about 300 x 250 x 350 mm deep |
| 128 | Providing and fixing SS 304 Kitchen Dustbin holder as per drawing and specifications & instructions as bellows including cutting welding/ soldering, grinding, necessary ss frame work, polishing/buffing, necessary hardware, drilling, p/f hafale hardware fittings, finishing and cleaning etc. completed as per specification and direction of the PMC/IOCL.Kitchen Dustbin size = 8-10 L |
| 129 | Providing and fixing 600mm wide and 20mm thick marine prelaminated ply (Century Ply, Greeen ply, Sharon or Kitply) Shelves fixed below kitchen platform at given location properly as per architectural drawing and instructions made out of 20mm thick marine approved prelaminated ply including providing all necessary consumables viz. adhesive, necessary hardware, 2mm thick matching pvc beading, fastenings, cleaning, finishing and cleaning etc. complete at all floors & heights as specified and as directed by PMC/IOCL. ( Mode of measurement- Only running length of shelves shall be measured for payment ) |
| 130 | Supplying and fixing Electric Chimney, 600mm wide having suction capacity of 700 cum/ hour with filter and duct complete in all res pects (Make : Glen/Sleek/Faber) or equivalent). Cost is inclusive of supply and installation of chimney with max. 6m long exhaust pipe and accessories along with liasoning with vendor's representative complete. |
| 131 | TV CONSOLE - Providing, making and assembling TV Console (about 1800 x 420 x 350 mm in size) , as per architectural drawing and instructions. The TV console shall be fixed on wall at given location as per drawing provided by Vendor. The system details shall be specified in technical specification etc. complete as directed by PMC/IOCL. |
| 132 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) |
| 133 | Fixed glazing with powder coated aluminium (minimum thickness of powder coating 50 micron) sections. |
| 134 | Providing & fixing fly proof galvanised M.S. wire gauze to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm with 2nd class teak woodbeading 62x19 mm all complete |
| 135 | For shutters of doors, windows & ventilators with powder coated (minimum thickness of powder coating 50 micron) aluminium sections including providing fixing SS hinges / pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) |
| 136 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness. |
| 137 | Extra for providing heavy sheet float glass panes of 5mm thickness instead of ordinary 4mm thick float glass in glazed doors, windows & clerestory window shutters.(Area of opening for glass panes excluding portion inside rebate shall be measured) |
| 138 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
| 139 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8.0 mm thickness. |
| 140 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather resistant silicon sealant of make Dr. Fixit Silicon or equelent over backer rod of approved quality as per direction of Engineer in Charge complete up to required depth and width as per site condition. |
| 141 | Providing & fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). |
| 142 | Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). |
| 143 | Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (Best make of approved quality) of : |
| 144 | i) Size 50 |
| 145 | ii) Size 75 |
| 146 | Providing & fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. |
| 147 | Providing & fixing chromium plated brass handles with necessary screws etc. complete: |
| 148 | i) 125 mm |
| 149 | ii) 100 mm |
| 150 | iii) 75 mm |
| 151 | Providing and fixing 25 mm dia curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc. complete. and directed by PMC/IOCL. |
| 152 | Providing & fixing chrome plated brass100mm mortise latch with one dead bolt with 6 levers & a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 153 | Door hinges Stainless steel butt hinges with ball bearings 125mm long |
| 154 | Steel peep hole with chromium plating |
| 155 | Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete |
| 156 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 157 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm |
| 158 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete :i) 200x10 mm |
| 159 | Handling and Refixing of IOCL supplied existing wardrobe / kitchen cabinet on walls with proper clamps/ screws including repairing of the same and replacing the damaged fittings (locks/Handles/drawer/slding rails/hindges etc) if required and other allied work as per direcition of Engineer-In-Charge. |
| 160 | PLUMBING WORK |
| 161 | Supply, Installation, Testing and Commissioning of 15mm dia C.P. Two way Two way bib cock jaquar make / modelThisincludes jointing of pipes &fittings with one step CPVC solventcementand the cost of cutting chasesand making good the sameincludingtesting of joints complete asper direction of EngineerinCharge.Concealed work includingcutting chases and making good thewallsetc.i) 15 mm nominal outer diaPipesRemoved/Dismantled piping shall bethe property of the contractor and toberemoved from site with the approval ofPMC/IOCL.\\" |
| 162 | Supply, Installation, Testing and Commissioning of approved make / model 15mm dia C.P. Angular stop cock with wall flange Jaquar make or equivalent continental (CAT.NO.CON-059) including necessary sockets/union nut etc. as pertechnical specifications and directionsof PMC/IOCL. |
| 163 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes 75 mm diameter |
| 164 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes 110 mm diameter |
| 165 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes 160 mm diameter |
| 166 | Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. |
| 167 | i) 75mm Coupler |
| 168 | ii) 110mm Coupler |
| 169 | iii) 75 mm Single pushfit Coupler |
| 170 | iv) 110 mm Single pushfit Coupler |
| 171 | v) Single tee with door of 75x75x75 mm |
| 172 | vi) Single tee with door of 110x110x110 mm |
| 173 | vii) Single tee without door of 75x75x75 mm |
| 174 | viii) Single tee without door of110x110x110 mm |
| 175 | ix) 87.5° Bend of 75 mm |
| 176 | x) 87.5° Bend of 110 mm |
| 177 | xi) Shoe (Plain) of 75 mm |
| 178 | xii) Shoe (Plain) of 110 mm |
| 179 | i) 160 mm UPVC Coupler |
| 180 | ii) 160 mm Single push fit Coupler |
| 181 | iii) Single tee with door of 160x160x160 mm |
| 182 | iv) Single tee without door of 160x160x160 mm |
| 183 | v) 87.5 degree bend of 160 mm |
| 184 | vi) Shoe (Plain) of 160 mm |
| 185 | Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100mm inlet & 75mm outlet SCI S&S as per IS - 3989. |
| 186 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 187 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed workincluding cutting chases and making good the walls etc- 32 mm nominal outer dia Pipes |
| 188 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed workincluding cutting chases and making good the walls etc.. - 20 mm nominal outer dia Pipes. |
| 189 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed workincluding cutting chases and making good the walls etc.. -15 mm nominal outer dia Pipes. |
| 190 | iii) 25 mm nominal outer dia CPVC Pipes |
| 191 | v) 40 mm nominal outer dia CPVC Pipes |
| 192 | vi) 50 mm nominal outer dia CPVC Pipes |
| 193 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required, Kitchen Sink with Drain board |
| 194 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required, Kitchen Sink with Drain boardSink with drain board 510x1040mm bowl depth 250mm |
| 195 | Providing and fixing soil, waste and vent pipes : |
| 196 | Providing and fixing soil, waste and vent pipes : 100mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. |
| 197 | Providing and fixing soil, waste and vent pipes : 75mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 198 | Providing and fixing front operated concealed cistern Kohler cat no- K-77029IN-M-NA or equivalent make with loop type actuator plate complete including integrated angle stop valve, flush bend with protective cover, slotted flat irons, fastening brackets and flushing pipe etc. as per specification and direction of Engineer-in-charge. |
| 199 | Providing and fixing first quality (heavy duty) type glazed vitreous china P or S trap Wall hung coloured water closet, seat cover, CP nuts, bolts and other necessary fittings all complete and as per specification and direction of Engineer-in-charge. |
| 200 | Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 201 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 202 | White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap |
| 203 | Supply, Installation, Testing and Commissioning of Off-white/Ivoryglazed vitreous under counter Hand Wash Basin list of approved size,make/model including of Basin Mixer C.P. Angle cock, CP Connector PipesC.P. waste coupling, C.P. bottle-trap with extension piece, C.I.brackets for the same, including providing consumable item such as Hotdeep galvanised nut bolts, s.s. screws etc complete of approved make asper technical specifications and directions of PMC/IOCL.Make :JAQUAR/HINDWARE/KOHLER.Model No.(CNS-WHT#705/10080/2949T-0) |
| 204 | Providing and fixing C.P. brass angle valve for basin mixer & geyser points of approved quality conforming to IS:8931 - 15mm nominal bore |
| 205 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 206 | Supply,Installing, Testing & Comissioning of approved make / model Health Faucet as per technical specifications and directions of PMC/IOCL. |
| 207 | Providing and fixing toilet paper holder : |
| 208 | Providing and fixing toilet paper holder : C.P. brass as per approval and instructions of the Engineer-in-charge. |
| 209 | Providing and fixing 450 mm long CP Brass towel rail complete with brackets fixed to wooden/PVC cleats with SS screws with concealed fittings arrangement of Make: Cera F5007104 or equivalent all complete and as per direction of Engineer-in-charge.. |
| 210 | Providing and fixing of SS single Soap tray with all fittings and all complete, as per specification and approval and instructions of the Engineer-in-charge. |
| 211 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 212 | Supply, Installation, Testing and Commissioning of approved make / model Shower assembly such as 4 way single lever diverter having inbuilt NRV, Wall spout, overhead rose shower with revoling joint pattern all complete with Hot & Cold connections of approved make as per technical specifications and directions of PMC/IOCL. |
| 213 | Supply, Installation, Testing and Commissioning of Hand shower with hose in polished chrome and handshower bracket as per technical specifications and directions of PMC/IOCL including Wall cutting & filling, Material Loading,Unloading shifting,installation.testing & commisioning inclusive of all accessories & fixtures required for installation. |
| 214 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 215 | 160 mm diameter PVC Rain water pipe |
| 216 | Supply,Installation, Testing & Comissioning of approved make / model recessed type S.S /Vitreous Soap dish of size 200 x 150mm as p er technical specifications and directions of PMC/IOCL. |
| 217 | Gardening (Lawn) |
| 218 | Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within premises and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 219 | Supplying and stacking of good earth at site including royalty and carriage up to 5 km (earth measured in stacks will be reduced by 20% for payment). |
| 220 | Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). |
| 221 | Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : |
| 222 | i) Screened through sieve of I.S. designation 20mm |
| 223 | ii) Screened through sieve of I.S. designation 16mm |
| 224 | iii) Screened through sieve of I.S. designation 4.75mm |
| 225 | Rough dressing the trenched ground including breaking clods. |
| 226 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 227 | Fine dressing the ground |
| 228 | Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately). |
| 229 | Mixing earth and sludge or manure in proportion specified or as directed by Engineer I/c |
| 230 | Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth if needed (the grass and good earth shall be paid for separately). |
| 231 | Grassing With grass turf |
| 232 | Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and levelling (cost of supplying earth and sludge or manure and mixing excluded). |
| 233 | Non Civil |
| 234 | ELECTRICAL WORK |
| 235 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). |
| 236 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). ii) 9\\" dia light duty, make Khaitan or equivalent |
| 237 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: |
| 238 | WALL FANS Supply & fixing of ceiling fan for inside of the sales building of following type: 300 MM Sweep wall mounted fan |
| 239 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: 1200 mm sweep |
| 240 | Supply, Installation, Testing andCommissioning of approved make/ model 3 litres Geyser, Concealed Stop / Angle Cock with supply of consumablematerial such as flexible pipe /C.P. pipe as per the length required,hot dip galvanised Brackets & Nut-bolts, Anchor Fasteners C.P. Elbow ofapproved make complete with connection of approved make as per technicalspecifications and directions of PMC/IOCLMake: |
| 241 | Supply, Installation, Testing and Commissioning of approved make / model 15 litres Geyser, Concealed Stop / Angle Cock with supply of consumable material such as flexible pipe /C.P. pipe as per the length required, hot dip galvanised Brackets & Nut-bolts, Anchor Fasteners C.P. Elbow of approved make complete with connection of approved make as per technical specifications and directions of P MC/IOCL. |
| 242 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 243 | Supply and Laying 3.5 Core x 70 sq. mm Aluminium Cable FRLS as per specifications and direction of Engineer in charge. |
| 244 | Supply and Laying 4 Core x 16 sq. Aluminium Cable FRLS as per specifications and direction of Engineer in charge. |
| 245 | CABLE JOINTING Cable Jointing : Providing straight through joint of following 1.1 KV grade XLPE insulated armoured cable with M-Seal make jointing kit, and other jointing material, etc. all complete including supply of all materials as per specification & direction of Engineer In-charge. |
| 246 | Supply and Laying 3.5 Core x 95 sq. mm Aluminium Cable FRLS as per specifications and direction of Engineer in charge |
| 247 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 248 | S/P Cable termination for 3.5 Core x 70 sq. mm. including double compression Non-FLP Glands etc. as per specifications and direction of Engineer-in charge. |
| 249 | S/P Cable termination for 4 Core x 16 sq. mm. including double compression Non-FLP Glands etc. as per specifications and direction of Engineer-in charge. |
| 250 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 251 | P/F Cable termination for 3.5 Core x 95 sq. mm with FLP double compression glands, lugs etc. as per specifications and direction of Engineer-in charge |
| 252 | PROVISION OF EARTHING |
| 253 | Providing earthing with 80MM dia 3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt and charcoal, making earth pit chamber with chequered plate cover as per standard Drawing all complete as per specification and direction of Engineer In-charge. |
| 254 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
| 255 | Supply & Laying Earthing 50 x 10mm G.I. Strip as per specifications and direction of Engineer in Charge |
| 256 | Supply & Laying Earthing 50 x 6mm G.I. Strip as per specifications and direction of Engineer in Charge |
| 257 | Supply & Laying Earthing 25 x 3 mm GI strip as per specifications and direction of Engineer in Charge |
| 258 | Supply & Laying Earthing 8 S.W.G. G.I. Wire (bare) as per specifications and direction of Engineer in Charge |
| 259 | Supply & Laying Earthing 6 S.W.G. Cu. Wire as per specifications and direction of Engineer in Charge |
| 260 | MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) |
| 261 | ii) S/E 6 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1No. & 6 to 16A SP as outgoing - 6 Nos. for each phase. |
| 262 | iii) S/E 8 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1 No. & 6 to 16A SP as outgoing - 8 Nos. for each phase. |
| 263 | PROVIDING INTERNAL WIRING |
| 264 | Providing internal Wiring :-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 265 | Wiring for light / power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable of approved make Anchor/Finolex/Havells etc in surface/ recessed appropriate size of PVC conduits (size25mm & thickness1.5mm) ISI mark (IS:9537)PVC along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required including modular switch of MK/ CRAB TREE (Murano or Equivalent )/ ABB with (Double module)all modular base plates & cover plates, GI box of same make , etc. complete. (Cost of modular switch, modular plate, moduler frame, modular socket, etc. to be made separately) |
| 266 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. |
| 267 | S/F modular switch frame with 6A, 3 Pin Modular Socket of MK/ CRAB TREE (Murano or Equivalent )/ ABB with (Double module)all modular base plates & cover plates, M.S. box of same make , etc. complete, as per specifications and direction of Engineer in Charge. |
| 268 | S/F modular switch frame with 15 A 6 Pin Modular socket of MK/ CRAB TREE (Murano or Equivalent )/ ABB with (Double module)all modular base plates & cover plates, M.S. box of same make , etc. complete, as per specifications and direction of Engineer in Charge. |
| 269 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge.:-i) Fan Regulator of stepped modular type |
| 270 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. |
| 271 | S/I/T/C of Electrical Panel, Standard drawing No. ENG/IOCL/PDIL-1. List of Componets are: (a) 1 No. MCCB (3P+N) of 160 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-150A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 160 A, Manually Operated Change over switch suitable for connection of Mains supply and 75 KVA DG Set /10 KW Solar system with required No. of MCCB (160 A, 35 KA, 3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 160A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/ Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 160/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 160 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4. (l) 12 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB 20 A, 10KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA,6 Nos DP MCB of 20A, 10 KA & 3 Nos DP MCB of 25 A, 10 KA in outgoing Feeder-3 (o) 3 Nos TP MCB of 16 A, 10 KA,3 Nos TP MCB of 20A, 10 KA & 6 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. |
| 272 | S/T/T/C of Electrical Panel, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. |
| 273 | Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc |
| 274 | Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. |
| 275 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 276 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make i) f 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire, as per specifications and direction of Engineer in Charge |
| 277 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 278 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire, as per specifications and direction of Engineer in Charge |
| 279 | Providing following point wiring with standard wire/ cable, plug, fittings, with suitable sockets, suitable GI box with front plate etc. complete, to include circuits from distribution boards to individual point boards, suitable PVC casing capping and required accessories pulling of wires, etc. complete. |
| 280 | Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 281 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 282 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 283 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 284 | Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 285 | Supply, installation, connection, testing and commissioning of Ding Dong / electronic musical type call bell with heavy duty coil su itable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size as per direction of PMC /IOCL. |
| 286 | Supplying & fixing Mirror light with fixing at site with required accessories, hardware & connection etc. complete for flat (7 watt to 9 watt lamp) |
| 287 | Supplying & fixing Door light with fixing at site with required accessories, hardware & connection etc. complete for flat (13 watt t o 15 watt lamp) |
| 288 | Supply, installation, connection, testing and commissioning of T8 LED 20W 4 feet tube light fitting with aluminium housing, heat si nk, integrated HF electronic driver complete (THD<15%)( including lamp) as per direction of PMC/IOCL. |
| 289 | Supply, installation, connection, testing and commissioning of Bulkhead fitting suitable for upto LED upto 12W fixed on wall as per direction of PMC/IOCL. |
| 290 | Supply, installation, connection, testing and commissioning of LED square / circular 5 to 8W down lighter having pressure die-cast a luminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete as per direction of PMC/IOCL. |
| 291 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 292 | xxii) 3.5 Core x 150 sq. mm Aluminium Cable FRLS |
| 293 | xiv) 4 Core x 16 sq. mm Aluminium Cable FRLS |
| 294 | xiii) 4 Core x 10 sq. mm Aluminium Cable FRLS |
| 295 | xii) 4 Core x 6 sq. mm Aluminium Cable FRLS |
| 296 | Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 297 | Supply and fixing of 3-phase,4 Wire energy meter (KWH)-electronic type |
| 298 | ii) CT operated |
| 299 | Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long |
| 300 | Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs |
| 301 | ii) 2+8 way SPN |
| 302 | iv) 4 way (4+12) TPN |
| 303 | Supply & fixing of 30mA RCCB of approved Make of following ratings: |
| 304 | Supply & fixing of 30mA RCCB of approved Make of following ratings:ii) 2 poles, 40A |
| 305 | Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. |
| 306 | Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc.i) Upto 32A SP MCB |
| 307 | MINIATURE CIRCUIT BREAKERS (MCB) Supplying & fixing of Miniature Circuit Breakers as per approved make of 10KA Breaking cpacity of following ratings |
| 308 | MINIATURE CIRCUIT BREAKERS (MCB) Supplying & fixing of Miniature Circuit Breakers as per approved make of 10KA Breaking cpacity of following ratings :i) 6A to 32A SP MCB |
| 309 | Supply and fixing 3-pole MCCB of breaking capacity 16 KA in existing panel board. |
| 310 | ii) 63 Amp |
| 311 | Supplying and erecting shockproof 6A porcelain base T.Switch / bell push erected on filled polypropylene board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected.(CSR2022-23,1-5-1) |
| 312 | Supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete.(CSR2022-23,1-6-18) |
| 313 | Supplying and erecting modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete.(CSR2022-23,1-6-19) |
| 314 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 315 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 316 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 317 | Supply & laying of CAT 6 network cable of approved make suitable for networking as per specification. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender