Tender For Urgent Supply Of Spares For 3.3Kv 400Kw Rating Jyoti Make Vacuum Contactor Of Elevation Pumps At 12Mld And 30Mld Plant At Assonora
Tender Overview
Project Description
Tender for Urgent Supply Of Spares For 3.3Kv 400Kw Rating Jyoti Make Vacuum Contactor Of Elevation Pumps At 12Mld And 30Mld Plant At Assonora , Supply Of Jyoti Make Closing Coil 110V/220V, Moc Ss/Brass Part No. J369-006 , Supply Of Jyoti Make Tripping Coil 110V/220V, Moc Ss/Brass Part No. J469-092 , Supply Of Jyoti Make 2 Pole Aux. Switch (1No+1Nc) Part No. J309- 021 Component Type: Circuit Trip Unit Technology: Thermal-Magnetic , Supply Of 3.3Kv Ht Hrc Fuse 160 Amps Voltage: 3.3Kv To 11Kv Rated Current: Upto 160A Usage/Application: Transformer Protection Rated Voltage:3.6Kv To 12Kv 5 Fuse Type: Clip Type , Supply Of Limit Switches For Vcb , Supply Of Jyoti Vaccum Interrupter Switching Motors Transformers And Capacitors. -Versions Electrical -Low Chopping Current (Maximum 1.5 annual periodical maintenance And Avg 0.9 Amp) -Suitable For High Switching Frequency (Around 300 Operations Per Hour) -Suitable For 3.3Kv / 6.6Kv 400 Amp. Rated Current - annual periodical maintenance 4 00 Interrupting Capacity-Ka 8.0 , Supply Of Jyoti Make Control Transformer Type Of Isolation Transformers: Control Circuit Isolation Trans Former Cooling Type: Air Cooled Frequency: 50 Hz Va Rating: 200 Kva Phase: Three Phase
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Jyoti make Closing Coil 110V/220V, MOC SS/Brass Part NO. J369-006 |
| 2 | Supply of Jyoti make Tripping Coil 110V/220V, MOC SS/Brass Part NO. J469-092 |
| 3 | Supply of Jyoti make 2 pole Aux. Switch (1NO+1NC) Part No. J309- 021 Component Type: Circuit Trip Unit Technology: Thermal-magnetic |
| 4 | Supply of 3.3KV HT HRC Fuse 160 Amps Voltage: 3.3kV to 11kV Rated Current: upto 160A Usage/Application: Transformer Protection Rated Voltage:3.6kV to 12kV 5 Fuse Type: Clip Type |
| 5 | Supply of Limit Switches for VCB |
| 6 | Supply of Jyoti Vaccum Interrupter Switching motors transformers and Capacitors.-Versions Electrical-Low Chopping Current (maximum 1.5 Amp and Avg 0.9 Amp) -Suitable for High Switching frequency (around 300 operations per hour)-Suitable for 3.3kv / 6.6kV 400 Amp.Rated Current - Amp 4 00 Interrupting Capacity-KA 8.0 |
| 7 | Supply of Jyoti make Control Transformer Type of Isolation Transformers: Control Circuit Isolation Trans former Cooling Type: Air cooledFrequency: 50 Hz VA Rating: 200 kVA Phase: Three Phase Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender