Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56740142

Tender For Facelifting And Renovation Works In Trauma Care, Government General Hospital, Karaikal.

Issued by Government Departments · Karaikal, Puducherry
Tender Value
14.16 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
6 days left
EMD
28335
Bank guarantee accepted
Document Fee
525
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Karaikal → Puducherry
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Facelifting And Renovation Works In Trauma Care, Government General Hospital, Karaikal.

BOQ

Name of Work:- Facelifting and Renovation works in Trauma Care, Government General Hospital, Karaikal.
Sl. No. Item Description
1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:4:8 (1 cement : 4 fine aggregate : 8 graded stone aggregate 40mm nominal size)
2Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping,bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centering ,shuttering and finishing - 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate 20mm nominal size)
3Providing , hoisting and fixing above plinth level upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement , with 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size)
4Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars Fe - 500D or more
5Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 fine aggregate)
6Mirror polishing on marble work / granite work / stone work where ever required to give high gloss finish complete
7Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding
8Providing and fixing ISI marked powder coating tower bolt black finish (Barrel type) with necessary screws etc.complete - 250 x10 mm
9Providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc complete
10Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI , IS :3564 , embossed on the body , door weight upto 35 kg and door width upto 700 mm ), with necessary accessories and screws etc complete
11Providing and fixing aluminium hanging floor door stopper , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc complete - Single rubber stopper
12Providing and fixing factory made uPVC white colour fixed glazed windows / ventilators comprising of uPVC multi - chambered frame and mullion (where ever required ) extruded profiles duly reinforced with 1.6 + or - 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension , EPDM gasket, G.I.fastners 100 x 8 mm size for fixing frame to finished wall , plastic packers , plastic caps and necessary stainless steel screws etc.Profile of frame shall be mitred cut and fusion welded at all corners , mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality , all complete as per approved drawing. (Single / double glass panes and silicon sealant shall be paid separately) - Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 + or - 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm) - Fixed window size - 1.20x0.50 m
13Steel work in built up tubular (round,square or rectanglar hollow tubes etc.) trusses etc., including cutting , hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete - hot finished welded type tubes
14Providing and laying vitrified floor tiles of size 600 x600 mm (thickeness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make , in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 fine aggregate) ,jointing with grey cement slurry @3.3 kg per sqm including grouting the joints with white cement and matching pigments etc., complete - size of tile600x600mm
15Extra for making chequers of approved pattern on cement concrete floors , steps, landing , pavements etc.,
16Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter
17Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
18Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
19Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe
20Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 fine aggregate) and making good the wall etc., complete - 110mm
21Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineerin-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
22Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm, zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns using self drilling / self tapping screws complete - Crimp curve
23Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade - New work (two or more coats applied @1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @0.90 litre / 10sqm)
24Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
25Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture , including applying additional coats wherever required to achive even shade and colour - Two coats
26Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content - with water thinnable cement primer on wall surface having VOC content less than 50 grams / litre
27Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc., complete
28Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade- One or more coats on old work
29Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story height made with 40 mm dia .M.S.tube 1.5m centre to centre , horizontal & vertical tubes joining with cup & lock system with M.S.tubes, M.S.tube challies, M.S.clamps and M.S.staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc.complete as approved. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. (Note: This item to be used for maintenance work judicically, necessary deduction for scaffolding in the existing item to be done.)
30Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. - Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
31Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead - of area 3 sqm and below
32Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - for thickness of tiles 10mm to 25mm
33Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead
34Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead
35Acid cleaning for the existing Mosaic floors , glazed tiles work and removing the stains and decays to give a glassy look etc complte (The Acid used shall be 32% concentrated hydrochloric acid after taking on the precautionary measures)
36Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I. brackets , 40 mm flush bend , overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets , cutting and making good the walls and floors wherever required - W.C.pan with ISI marked white solid plastic seat and lid
37Providing and fixing CP brass health faucet of approved quality - 15 mm nominal bore
38Providing and fixing Chlorinated Polyvinnyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer-incharge - internal work - exposed on wall - 25mm nominal dia pipes
39Providing and fixing Chlorinated Polyvinnyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer-incharge - internal work - exposed on wall - 32mm nominal dia pipes
40Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 25mm nominal bore
41Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 32mm nominal bore
42Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
43Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15 mm nominal bore
44Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore
45Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes - 110mm diametre
46Providing and fixing on wall face / column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS :5382 leaving 10mm gap for thermal expansion - Single tee without door - 110 x110x110mm
47Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend 110 mm
48Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
49Filling the gap in between aluminium / stone / wood frame and adjacent RCC / Brick / Stone / Wood / Ceramic / Gypsum work by providing weather / structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction complete, complying to ASTM C920 , DIN 18540-F & ISO 11600 - upto 10mm depth and 10 mm width
50Grading roof for water proofing treatment with - Cement concrete 1:2:4 (1 cement : 2 fine aggregate : 4 graded stone aggregate 20 mm nominal size)
51Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-incharge - 25 mm average thickness
52Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry , all complete as per direction of the Engineer-in-chargeBars above 12mm diameter
53Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. 26.31.1SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
54Providing , mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement : 4 graded fine aggregate with polymer minimum 2% by wt.of cement used) as per specifications and direction. Note: Measurement and Payment : The Pre-meaurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and / or the 75mm size cube crusing strength at the end of 28 days to be not less than 30 N / Sqmm) - 25 mm average thickness in two layers
55Providing and fixing factory made single extruded WPC (Wood Polymer composite) solid door / window / Ceosetory windows and Other frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 ( Suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frames density of 750 kg / cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compresssive strength of 58N/sq.mm, modulus of elasticity 900 N/sq.mm and resistance to spread of flame of class A category with property of being termite / borer proof, water / moisture proof and fire retardant and fixed in position of with M.S hold fast/lugs /SS dash fasteners of required dia and length complete as per direction of Engineerin-charge (M.S hold fast/lugs or SS dash fastners shall be paid for separately) Note: For WPC solid door / window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable . Variation in profile dimension on plus side shall be acceptable but no extra payments on this account shall be made. - Frame size 45 x 85 mm
56Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawl strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength 50N/sq.mm , modulus of elasticity 850 N/sq.mm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/ soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S.screws, all as per direction of Engineer-in-charge. (Note: Stainless steel piano hinges/ soft close clip on concealed hinges and necessary S.S.screws shall be paid separately) - 25 mm thick
57Providing and Laying non shrinkl free flow micro concrete renderoc RG or equialent in the proportion 1:1 (One renderoc Rg: one graded stone aggregate of 12.5mm and below through the drilled holes till the voids and damaged area are completely filled and set to an average thickness of 50mm as directed by the Engineer-In-charge.
58Providing leak proof centering and shuttering using 25mm thick plywood for damage slab / beam to carrying out micro concreting work including ceiling the gaps if any with renderoc plugging compund and removal of form work.
59Supply, erection testing and commissioning of 1.50 ton split type Air conditioner approved brand and manufacture of Daikin / mitsubishi / Hitachi / O General of the following specification - the Air conditioner shall be fit to run at single phase 230 volts 50 Hz, with capacity of 17750 btu per hour and 5.2KW with cop 2.86. The indoor unit shall have five step and automatic fan speed controls an air flow of minimum 17.5 cum/ min (618 cfm) sound level 3550DB (A) with horizontal and vertical air flow features cordless remote control unit and batteries as supplied by the manufacturer the outdoor unit shall have the compressor of hermetically set added rotary type with safety grills power consumption of 1530W with refrigerate charges (R-22) at 1.00 Kg and sound level below 55 DB, required provision in for liquid gas and drain connections for a maximum piping length upto 20M. The indoor and outdoor units shall be supplied as packed by the manufacture with user manual and warranty cards and reacted at a suitable location selected by the Department etc., complete all as directed by the Engineer-in-charge.
60Supply and fixing copper pipe 1/2\\" softness copper pipe 2mm thick for suction and delivery.
61Supply and fixing powder coated MS stand with the necessary screws / bolts and nuts weighting not less than 2.50Kg capable of holding the outdoor unit for fixing outdoor unit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56740142
AUTHORITY Government Departments
TENDER VALUE 14.16 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Facelifting And Renovation Works In Trauma Care, Government General Hospital, Karaikal.
Basic Detail
Tender No 09-02/PW/BRK/2026-27
Bidding Type Tender
Location
City Karaikal
State Puducherry
Key Dates
Publish Date 30 Jul 2026
Submission Date 06 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 14.16 Lakhs
Tender Fee 525
EMD 28335
Exemption Not Available
Document List
ad4f35cc-0f7a-4d56-beb4-9cc7a2a6a61b.html
BOQ_23100.xls
Tendernotice_1.pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

ad4f35cc-0f7a-4d56-beb4-9cc7a2a6a61b.html

xls

BOQ_23100.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail