Tender for special Repair Of Parking Shed To Bldg No Vps-01 At Transit Camp Of Age B/R And Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting of any thickness as in roof coverings complete all as specified and directed. |
| 2 | Supply and Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 3 | Supply and Fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 4 | Demolition of cement concrete (unreinforced) in ground floors and paving’s not exc 15 cm thickness (below or above ground level) |
| 5 | M&L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in sub floor finishing cement concrete surface complete all as specified and directed. |
| 6 | M&L for 15 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified and directed. |
| 7 | M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 8 | Dismantling of wall and ceiling board or insulation boards/slabs/blanckets/any thickness including cover fillets complete all as specified and directed. |
| 9 | S&F in repairs 4 mm thick ply wood, grade BWR, type BB, fixed with nails to timber frame work on ceiling surfaces. |
| 10 | M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 11 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm complete all as specified and directed. |
| 12 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm |
| 13 | S & F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 14 | S & F 2nd class hard wood plain framed panelled shutter 35mm thick (any number of panels) with panels of timber flat on both sides, feather edged or of veneered particle board medium density, wood particle board with commercial face veneer 30mm thick |
| 15 | S & F 2nd class hard wood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 16 | S & F 100mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 17 | S & F 75mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 18 | S& F Aluminium anodised barrel tower bolts 150mm long of extruded section and fixed |
| 19 | S& F Aluminium anodised barrel tower bolts 100mm long of extruded section and fixed |
| 20 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised |
| 21 | S & F 100mm size extruded aluminium alloy handles, fabricated type anodised |
| 22 | S & F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed. |
| 23 | S&F pre coated mild steel floor door stopper ,tongue anodized 140mm length including vulcanised rubber piece complete all as specified and directed. |
| 24 | S & F GI steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm etc all as specified. |
| 25 | S & F Sheet glass 3mm,ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane all as specified. |
| 26 | S&F PVC coated 25mm dia mild steel chromium plated curtain rod of medium weight and including fixing brackets, finals and decorative end supports etc complete all as directed” |
| 27 | S&F in repair 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed (Helical door closer). |
| 28 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar . |
| 29 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed. |
| 30 | M&L for Rendering 10mm thick in CM 1:3 work or concrete surfaces to recive wall tiles complete all as specified and directed. |
| 31 | M&L for Rendering 10mm thick in CM 1:4 work for fair faces of brick work or concrete surface complete all as specified and directed. |
| 32 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 33 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips as specified & directed. |
| 34 | M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders as specified & directed. |
| 35 | M&L for Flat Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc. as specified & directed. |
| 36 | M&L for RCC B1 1:2:4(20mm graded agg) in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and inshelves and the like complete all as specified and directed. |
| 37 | M&L for preparation of new surfaces of walls and applying two coat of OBD over a coat of alkali resitent primer as specified & directed. |
| 38 | M&L for preparation of new surfaces of walls and applying two coats of cement base paint over a coat of alkali resitent primer as specified & directed. |
| 39 | M&L for preparation of old surfaces of walls and applying one coat of OBD over a coat of alkali resitent primer as specified & directed. |
| 40 | M&L for preparation of old surfaces of walls and applying one coats of cement base paint over a coat of alkali resitent primer as specified & directed. |
| 41 | M&L for 75 mm thick plain cement concrete type C-2, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement complete all as specified and directed. |
| 42 | M&L for 20 mm thick screed bed in CM 1:4 for laying floor tiles complete all as specified and directed. |
| 43 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm/ 30cm x 30cm x 25cm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & no pigments as specified. |
| 44 | Dismantling wrought iron or mild steel work of any description not otherwise provided for as specified & directed. |
| 45 | M&L for Steel work in tubular trusses including special shaped washer etc. complete usingERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 as specified & directed. |
| 46 | Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 47 | All as per item No. 46 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 48 | All as per item No. 46 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 49 | All as per item No. 46 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified. |
| 50 | S&F Socket outlet 2 in 1, 3 pin, 6 amp flush type |
| 51 | S&F Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type |
| 52 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 16 Amp, 240 Volts complete all as specified & directed. |
| 53 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 54 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified & directed. |
| 55 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 56 | S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connecting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 Hz complete all as specified and directed. |
| 57 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbers clamps, all fixing arrangements such as fastners, bolts, nuts washers etc all as specified and directed. |
| 58 | S&F in replacement of distribution board Double door vertical type TPN 415 Volt for fixing MCB/Isolator as incomer, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed. |
| 59 | S&F MCB TPN having breaking capacity 10KA,'C' curve, 40-100 Amps, 415 V complete all as specified and directed. |
| 60 | S&F MCB SP having breaking capacity 10KA,'C' curve, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 61 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 62 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 6 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.) |
| 63 | S & F incl leakage testing galvanised steel water tubing medium grade 40 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. |
| 64 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 25 Sqmm 4 core complete all as specified and directed. |
| 65 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out complete all as specified and as directed. |
| 66 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 67 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 68 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 69 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection all as specified and directed. |
| 70 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 71 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. |
| 72 | Taking down sub main wiring of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender