Tender For Construction Of Helipad And Waiting Loungue At Rajouri
Tender Value
16.70 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
5 days left
EMD
33400
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Helipad And Waiting Loungue At Rajouri
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering –All work upto plinth level 1:3:6 using 20% plum of nallah split stone ( 1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size ) crushed |
| 2 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 3 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm |
| 4 | Providing and laying Reinforced Cement Concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) in suspended floors, balconies, landings and staircase having upto 15° slope. excluding cost of centering and shuttering , all work upto floor V level |
| 5 | Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete .Cold Twisted Bar |
| 6 | Centering and Shuttering including strutting, propping etc and removal of form work for mass concrete |
| 7 | Foundations, footings, bases of columns |
| 8 | Suspended floors, roofs, landings, balconies and access platforms |
| 9 | Stone filling hand packed in horizontal level including the cost of the stone |
| 10 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 11 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before B30treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 12 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels .Raj Nagar plain white marble/Udaipur green marble/zebra black marble (Area of slab over 0.5 sqm) |
| 13 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 14 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 15 | Making cup boards/wardrobes using water proof ply 19 mm thick all sides and for selves and lipping with 1 mm thick mica inner and outer including fillings junctions gaps fittings and fixtures complete job as per direction of engineer Incharge NSI |
| 16 | Providing, storing, handling, shifting, installation, testing & commissioning of vertical / horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 20mm CP brass cock and 20mm non return valve complete including making connection with 15 mm dia CP connecting pipe on Inlet and Outlet, suitable length of power cable and 15A plough (for pantry & Toilets). (Make : Hindware, Bajaj or equivalent) |
| 17 | Wiring for light point /fan point/exhaust fan point call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.( Group A) |
| 18 | Wiring for light point /fan point/exhaust fan point call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.( Group B) |
| 19 | Wiring for circuit/ sub-main wiring along with earth wire the following size of FRLS PVC insulated copper conductor single core cable in existing surface /recessed medium class PVC conduit. |
| 20 | 2 x 1.5sq.mm +1 x 1.5 sq.mm earthwire |
| 21 | 2 x 2.5sq.mm +1 x 2.5 sq.mm earthwire |
| 22 | 2 x 4.sq.mm +1 x 4 sq. mm earthwire |
| 23 | 4 x 6. sq.mm + 2 x 6 sq. mm earthwire |
| 24 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the esisting surface/recessed steel PVC conduit as required 2 pair |
| 25 | Supplying and fixing following modular switch/socket on the existing modular plate & switch including connections but excluding modular plate etc. as required. |
| 26 | 5/6 A Switch |
| 27 | 15/16 A Switch |
| 28 | 3 pin 5/6 A Socket outlet |
| 29 | 6 pin 15/16 A Socket outlet |
| 30 | Telephone Socket outlet |
| 31 | Bell push |
| 32 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 33 | Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required . |
| 34 | Supplying and fixing following Modular base & cover plate on modular metal boxes etc. as required. |
| 35 | 1or 2 Module |
| 36 | 3 Module |
| 37 | 4 Module |
| 38 | 6 Module |
| 39 | 8 Module |
| 40 | Installation, testing and commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamp per fitting, complete with all accessories including |
| 41 | Supply and fixing call bell/buzzer suitable for single phase, 230V, Complete as required. |
| 42 | Installation, testing and commissioning of ceiling fan , including writing the down rods of |
| 43 | standard length ( upto 30 cm) with 1.5 sq mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box as required. |
| 44 | Supply and drawing of UTP pair CAT 6 LAN cable in the existing surface / recessed steel/PVC conduit as required (1 run of cable) |
| 45 | Supplying and fixing 5 A rating, 240/ 415 V,10 KA,”C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 46 | Single pole |
| 47 | Single pole with neutral |
| 48 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 49 | Supplying and fixing of following rating 240 volts “C” series miniature circuit breaker suitable for lighting and other loads of following poles n the existing MCB DB complete with connections, testing and commissioning.( make as per annexure enclosed ) |
| 50 | Triple Pole and neutral 63/40Amp. |
| 51 | Supplying and fixing of surface 10 watts LED batten fitting for Mirror light including connections etc. as required. |
| 52 | Providing and installation of 2 core 10sq mm Al cable for temporary Electerification |
| 53 | Supplying and fixing of surface 20/22watts batten LED tube fitting 4 feet long including connections etc. as required |
| 54 | Supplying and fixing of surface mounted bracket light fitting suitable for one no 9watts LED bulb including connections etc. as required complete with 9watts LED bulb. |
| 55 | Supplying and fixing of following electrical items suitable for operating on 240/230V AC, 50Hz including connections etc. |
| 56 | Ceiling fan 1200mm sweep ( 5 star rating) |
| 57 | Wall fan 400mm sweep |
| 58 | Exhaust fan 300mm size |
| 59 | 2- way AC box |
| 60 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface recess including cutting the wall and making good the same in case of recessed conduit as required |
| 61 | Providing and fixing of LT Panel after fabrication of panel with 14 CRCA Sheet, hinged lockable door, LED indicator lamp, Bus Bar, powder coated along with following accessories:- incoming- 240A 4P 36K MCCB- 01Nos, outgoing- 100A 4P 25K MCCB- 09 Nos, 63A TPN MCB- 01Nos, 63A SPN MCB-01Nos. Complete with all lift and leads, testing commissioning etc. MAKE: MCCB/MCB-LEGRAND/ABB- (Emergency L T Panel) with Changeover 250 amp. of some reputed make such as Havels including wiring all complete |
| 62 | Providing and laying of 300 sq mm 3.5 core PVC insulated Al cable along with reqd. size of Al Glands and also laying of cable after complete digging process with the cost of PVC pipe of dia 110mm of 6kg Pressure, including excavation work, concreting etc. |
| 63 | Providing and laying of 185sq mm 3.5 core PVC insulated Al cable along with reqd. size of Al Glands and also laying of cable after complete digging process with the cost of PVC pipe of dia 110mm of 6kg Pressure, including excavation work, concreting etc. |
| 64 | Carriage of material from source to site of work by mechanical transport including loading /unloading and stacking complete. |
| 65 | Sand for an average distance of 120 kms by M.T |
| 66 | Stone aggregate below 40 mm nominal size for an average distance 25 kms by M.T |
| 67 | Stone for an average distance of 5 Km by M.T Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender