Heavy Industries and Public Enterprises Boards / Undertakings / PSU Closing in 9 days TDR #56739339

Bids Are invited for E4963042 For Wound Cts Slot Cts And Pts For Bpcl Bina Refinery Project Of Eil

Issued by Boards / Undertakings / PSU · Bhopal, Madhya Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Aug 2026
9 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
238

Project Description

Bids Are invited for E4963042 For Wound Cts Slot Cts And Pts For Bpcl Bina Refinery Project Of Eil E4963042 Wound Ct Slot Ct And Pt 01-Sg4950377175-Wound Ct Ratio 150_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-1. , 02-Sg4950377183-Wound Ct Ratio 250_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-2. , 03-Sg4950377191-Wound Ct Ratio 300_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-3. , 04-Sg4950377205-Wound Ct Ratio 300-150_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-4. , 05-Sg4950377213-Slot Ct Ratio 1000_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-5. , 06-Sg4950377221-Slot Ct Ratio 1250_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-6. , 07-Sg4950377230-Wound Ct Ratio 300_Slash_1A Core-I-Vk_Greateq_300V Rct_Less_3Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-7. , 08-Sg4950377248-Slot Ct Ratio 1000_Slash_1A Core-I-80Rct_Plus_15Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-8. , 09-Sg4950377256-Slot Ct Ratio 1000_Slash_1A Core-I-80Rct_Plus_36Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-9. , 10-Sg4950377264-Slot Ct Ratio 1250_Slash_1A Core-I-64Rct_Plus_12Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-10. , 11-Sg4950377272-Slot Ct Ratio 1250_Slash_1A Core-I-64Rct_Plus_30Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-11. , 12-Sg4950377280-Pt Ratio 6600_Slash_R3_Slash_ 110V_Slash_R3 _Slash_ 110V_Slash_R3 _Slash_ 100V_Slash_3 Core-I-100Va 3P Core-Ii-100Va 1.0 Core-Iii-50Va 3P As Per Ann-A It-12. , 13-Sg4950377299-Pt Ratio 6600_Slash_R3_Slash_ 110V_Slash_R3 _Slash_ 110V_Slash_R3 Core-I-100Va 3P Core-Ii-100Va 1.0 As Per Ann-A It-13. , 14-Sg4950377302-Pt Ratio 6600_Slash_110V Core-I-50Va 3P As Per Ann-A It-14.

BOQ

Sl. No. Item TitleItem Description
1E4963042 Wound CT Slot CT and PT 01-SG4950377175-WOUND CT RATIO 150_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-1.E4963042 Wound CT Slot CT and PT 01-SG4950377175-WOUND CT RATIO 150_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-1.
202-SG4950377183-WOUND CT RATIO 250_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-2.02-SG4950377183-WOUND CT RATIO 250_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-2.
303-SG4950377191-WOUND CT RATIO 300_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-3.03-SG4950377191-WOUND CT RATIO 300_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-3.
404-SG4950377205-WOUND CT RATIO 300-150_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-4.04-SG4950377205-WOUND CT RATIO 300-150_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-4.
505-SG4950377213-SLOT CT RATIO 1000_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-5.05-SG4950377213-SLOT CT RATIO 1000_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-5.
606-SG4950377221-SLOT CT RATIO 1250_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-6.06-SG4950377221-SLOT CT RATIO 1250_slash_1-1A CORE-I- 10VA 5P10 CORE-II- 15VA 1.0 AS PER ANN-A IT-6.
707-SG4950377230-WOUND CT RATIO 300_slash_1A CORE-I-VK_greateq_300V RCT_less_3OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-7.07-SG4950377230-WOUND CT RATIO 300_slash_1A CORE-I-VK_greateq_300V RCT_less_3OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-7.
808-SG4950377248-SLOT CT RATIO 1000_slash_1A CORE-I-80RCT_plus_15OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-8.08-SG4950377248-SLOT CT RATIO 1000_slash_1A CORE-I-80RCT_plus_15OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-8.
909-SG4950377256-SLOT CT RATIO 1000_slash_1A CORE-I-80RCT_plus_36OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-9.09-SG4950377256-SLOT CT RATIO 1000_slash_1A CORE-I-80RCT_plus_36OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-9.
1010-SG4950377264-SLOT CT RATIO 1250_slash_1A CORE-I-64RCT_plus_12OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-10.10-SG4950377264-SLOT CT RATIO 1250_slash_1A CORE-I-64RCT_plus_12OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-10.
1111-SG4950377272-SLOT CT RATIO 1250_slash_1A CORE-I-64RCT_plus_30OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-11.11-SG4950377272-SLOT CT RATIO 1250_slash_1A CORE-I-64RCT_plus_30OHM IE_lesseq_30MA AT VK_slash_2 AS PER ANN-A IT-11.
1212-SG4950377280-PT RATIO 6600_slash_R3_slash_ 110V_slash_R3 _slash_ 110V_slash_R3 _slash_ 100V_slash_3 CORE-I-100VA 3P CORE-II-100VA 1.0 CORE-III-50VA 3P AS PER ANN-A IT-12.12-SG4950377280-PT RATIO 6600_slash_R3_slash_ 110V_slash_R3 _slash_ 110V_slash_R3 _slash_ 100V_slash_3 CORE-I-100VA 3P CORE-II-100VA 1.0 CORE-III-50VA 3P AS PER ANN-A IT-12.
1313-SG4950377299-PT RATIO 6600_slash_R3_slash_ 110V_slash_R3 _slash_ 110V_slash_R3 CORE-I-100VA 3P CORE-II-100VA 1.0 AS PER ANN-A IT-13.13-SG4950377299-PT RATIO 6600_slash_R3_slash_ 110V_slash_R3 _slash_ 110V_slash_R3 CORE-I-100VA 3P CORE-II-100VA 1.0 AS PER ANN-A IT-13.
1414-SG4950377302-PT RATIO 6600_slash_110V CORE-I-50VA 3P AS PER ANN-A IT-14.14-SG4950377302-PT RATIO 6600_slash_110V CORE-I-50VA 3P AS PER ANN-A IT-14.

AI Tender Summary

OUR REF NO 56739339
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 10-08-2026
Authority
Authority Name Bharat Heavy Electricals Limited
Work Description Bids Are invited for E4963042 For Wound Cts Slot Cts And Pts For Bpcl Bina Refinery Project Of Eil E4963042 Wound Ct Slot Ct And Pt 01-Sg4950377175-Wound Ct Ratio 150_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-1. , 02-Sg4950377183-Wound Ct Ratio 250_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-2. , 03-Sg4950377191-Wound Ct Ratio 300_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-3. , 04-Sg4950377205-Wound Ct Ratio 300-150_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-4. , 05-Sg4950377213-Slot Ct Ratio 1000_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-5. , 06-Sg4950377221-Slot Ct Ratio 1250_Slash_1-1A Core-I- 10Va 5P10 Core-Ii- 15Va 1.0 As Per Ann-A It-6. , 07-Sg4950377230-Wound Ct Ratio 300_Slash_1A Core-I-Vk_Greateq_300V Rct_Less_3Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-7. , 08-Sg4950377248-Slot Ct Ratio 1000_Slash_1A Core-I-80Rct_Plus_15Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-8. , 09-Sg4950377256-Slot Ct Ratio 1000_Slash_1A Core-I-80Rct_Plus_36Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-9. , 10-Sg4950377264-Slot Ct Ratio 1250_Slash_1A Core-I-64Rct_Plus_12Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-10. , 11-Sg4950377272-Slot Ct Ratio 1250_Slash_1A Core-I-64Rct_Plus_30Ohm Ie_Lesseq_30Ma At Vk_Slash_2 As Per Ann-A It-11. , 12-Sg4950377280-Pt Ratio 6600_Slash_R3_Slash_ 110V_Slash_R3 _Slash_ 110V_Slash_R3 _Slash_ 100V_Slash_3 Core-I-100Va 3P Core-Ii-100Va 1.0 Core-Iii-50Va 3P As Per Ann-A It-12. , 13-Sg4950377299-Pt Ratio 6600_Slash_R3_Slash_ 110V_Slash_R3 _Slash_ 110V_Slash_R3 Core-I-100Va 3P Core-Ii-100Va 1.0 As Per Ann-A It-13. , 14-Sg4950377302-Pt Ratio 6600_Slash_110V Core-I-50Va 3P As Per Ann-A It-14.
Basic Detail
Tender No GEM/2026/B/7852421
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 30 Jul 2026
Submission Date 10 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
b7b85584-2480-4030-bdb5-5418e9bd5018.pdf
01_boq_pqr___specification_e4963042_mii_mar26_2026-07-30-09-17-52_8d43b43974b124d284072b6d184192a0.pdf
9681611_Boq_1.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

b7b85584-2480-4030-bdb5-5418e9bd5018.pdf

pdf

01_boq_pqr___specification_e4963042_mii_mar26_2026-07-30-09-17-52_8d43b43974b124d284072b6d184192a0.pdf

xlsx

9681611_Boq_1.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders