Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56738974

Tender For Operation & Maintenance Of Street Lights & High Masts I/C Monitoring Of Street Light At Various Locations In North East Area Under Sub Division-I/M-2511 Delhi (Sh:- Replacement Of Rusted Poles Defective Fittings, Damaged Cables And Its Ass

Issued by Government Departments · Delhi, Delhi
Tender Value
29.02 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
5 days left
EMD
58058
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Operation & Maintenance Of Street Lights & High Masts I/C Monitoring Of Street Light At Various Locations In North East Area Under Sub Division-I/M-2511 Delhi (Sh:- Replacement Of Rusted Poles Defective Fittings, Damaged Cables And Its Associated Electrical Items)

BOQ

Name of Work:- Operation & Maintenance of Street lights & High Masts i/c monitoring of Street light at various locations in North East area under Sub Division-I/M-2511 Delhi (SH:- Replacement of Rusted Poles Defective fittings, Damaged cables and Its Associated Electrical Items)
Sl. No. Item Description
1Supplying & Erection of Hot Dipped galvanized 10 meter height octagonal pole with 1.5 meter long double arm Hot Dipped Galvanized GI bracket in approved design capable of holding the minimum weight of the luminaire. The pole structural design shall be as per ILE TR7 considering the wind speed as per IS:875, the HT steel for construction should be as pre BSEN10025 grade S355Jo, minimum thickness 3 mm, hot dip galvanizing on both internal and external surfaces as per IS:2629/ IS:2633/ IS:4759 with average coating thickness of 65/70 microns through a single dipping process. The pole shall also be provided with hinged/chained flush door of length not less than 300 mm at an elevation of 1.0 m (approx.) from the base plate with proper strengthening to the cutout of the door opening. Each pole shall be complete with a bakelite sheet complete with DIN Rail, 2/6 amps, 10KA SPN MCB, Screwless DIN mounting connectors suitable for cable terminations complete with Grade) of min. 20 mm dia each with three GI nuts and two GI washers etc. complete as per drawing. The pole shall have a minimum of OAF of 175mm at bottom and minimum of 70 mm at top. The pole bottom shall be enclosed with 200 mm dia DWC pipe upto a height of 2.5 mtr. to avoide theft and electrocution. The pole shall have a section thickness of not less than 3 mm, base plate minimum 275mm x 275mm x 16mm with 250 mm dia DWC pipe to cover/enclose the pole from prevention of the electrocution. The pole shall be fabricated in a single section. ...........................Cont....................................
2Pole foundation size must be 900 mm (L) x 900 mm (W) x 700 mm (D) using (1:2:4) reinforced cement concrete foundation with 20 Nos. 10 mm TMT Bars, 12 mm of 5.6 mtr. and 8 mm of 3.2 mtr. required etc. complete as required. The pole and pole foundation should be approved from Engineer- in-charge before starting of work.
3LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage rotection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of nitial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 m/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-charge as per requirement. (Thermal management: heat sink of Aluminium housing such that LED junction temperature shall to rise above 90°C).
4200 watt
5Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
663 mm dia (OD-63 mm & ID-51 mm nominal)
7Supplying and laying of following PVC insulated and PVC sheathed /XPLE armounrd Aluminum Conductor power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL pipe as required.
83.5 x 70 Sq. mm (surface with 25 x 3 mm flat clamp)
94 x 25 Sq. mm (In pipe)
104 x 16 Sq. mm (In pipe)
11Supplying & Fixing of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
123 output (1output per phase) and suitable for three phase supply
13Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
14100 A,30KA, FPMCCB
15Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)
16Credit for old dismantle
17Rusted Pole GI - 10 Mtr.
18Assorted timer
19Assorted MCCB Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56738974
AUTHORITY Government Departments
TENDER VALUE 29.02 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Operation & Maintenance Of Street Lights & High Masts I/C Monitoring Of Street Light At Various Locations In North East Area Under Sub Division-I/M-2511 Delhi (Sh:- Replacement Of Rusted Poles Defective Fittings, Damaged Cables And Its Associated Electrical Items)
Basic Detail
Tender No 56/EE(E)/PWD NES ED/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 29 Jul 2026
Submission Date 05 Aug 2026
Open Date 05 Aug 2026
Finance
Tender Value 29.02 Lakhs
Tender Fee Ref. Documents
EMD 58058
Exemption Available
Document List
71e49c97-f0ef-4005-b7e4-b1e6222a0b36.html
BOQ_394175.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

71e49c97-f0ef-4005-b7e4-b1e6222a0b36.html

xls

BOQ_394175.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders