Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56738370

Tender For Running Maintenance Of Pipelines Of Various Existing Piped Water Supply (Pws) Schemes At East Noabadi, Herbang, Wakhinagar, And Dinabandhunagar Under Pwd (Dws), Mandwi Rd Block, Within The Jurisdiction Of Pwd (Dws) Sub-Division, Mandwi.Sh:

Issued by Government Departments · tripura, Tripura
Tender Value
3.79 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
5 days left
EMD
7583
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Running Maintenance Of Pipelines Of Various Existing Piped Water Supply (Pws) Schemes At East Noabadi, Herbang, Wakhinagar, And Dinabandhunagar Under Pwd (Dws), Mandwi Rd Block, Within The Jurisdiction Of Pwd (Dws) Sub-Division, Mandwi.Sh:Maintenance Of Pipelines And Other Allied Works Of Existing Piped Water Supply (Pws) Schemes During The Year 2026-27.Gp-1

BOQ

Name of Work:- Running maintenance of pipelines of various existing Piped Water Supply (PWS) schemes at East Noabadi, Herbang, Wakhinagar, and Dinabandhunagar under PWD (DWS), Mandwi RD Block, within the jurisdiction of PWD (DWS) Sub-Division, Mandwi.SH:Maintenance of pipelines and other allied works of existing Piped Water Supply (PWS) schemes during the year 2026–27.GP-1
Sl. No. Item Description
1Washing & removal of deposited iron sludge & any other foreign materials etc. from inside the existing water distribution pipe line foreign materials from inside the excavation trenches up to required width & depth cutting of PVC pipe line at a length of every 55.00 Mtr. interval jointing of pipe with PVC coupler and solvent cement in/c satisfactory testing of joints refilling trenches with available excavated earth etc. complete as per direction of the Engineer-in-charge [Rate in/c the cost of cement solvent PVC pipe for making PVC couplers, will be issued by the Department at free of cost).
2i) 90 mm dia
3ii) 110 mm dia
4iii) 140 mm dia
5Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge.
6i) 10 mm nominal bore
7Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
8i) 40 mm OD
9ii) 50 mm OD
10iii) 90 mm OD
11Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
12i) 40 x40 mm dia
13ii) 50 x50 mm dia
14iii) 90 x 90 mm dia
15iv) 110 x 110 mm dia
16Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
17i) 50 x 40 mm dia
18ii) 110 x 90 mm dia
19Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as er CPWD specification anddirection of the Engineer - in - charge
20i) 90 mm dia
21ii) 110 mm dia
22iii) 140 mm dia
23Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
24i) 40 mm dia
25ii) 50 mm dia
26iii) 90 mm dia
27iv) 110 mm dia
28v) 140 mm dia
29Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in charge.
30i. 90 mm OD
31ii. 110 mm OD
32iii. 140 mm OD
33Providing and fixing G.I. Nipple of medium class as per CPWD specification and direction of the Engineer - in - charge.
34i) 15 mm dia 150 mm long
35Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately).
36i) 15 mm dia
37Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
38i) 15 mm dia
39Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.
40i) 15 mm dia
41Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.
42i) 15 mm dia
43Making road crossing by horizontal boaring for smooth laying of UPVC/CI/DI/GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.
44A. By manual means
45Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.
46(i) 15 mm dia PVC /plastic bib cock
47Supplying and wooden toolbox of size 1.00 x 0.60 x 0.75 m in/c MS bolt hinge with necessary screw, sliding door bolt and painting complete as per direction of the Engg-in-Charge.
48Supplying ISI marked/ Taparia make tools for water scheme.
49i) Sly wrenches (12”)
50ii) Pipe wrench (14”)
51iii) Pliers (8”)
52iv) Screw Driver (8”)
53v) Hacksaw frame with blade 2 Set
54Providing & fitting, fixing of signboard (Size 1.00 X 0.75m) at water supply scheme in/c cost of 1mm thick plain aluminum or G.I. sheet with necessary MS angle (40 X 40 X 5mm) in/c necessary bending and fixing on the GCI walling of pump house and painting writing nail spikes etc. and carrying to the work site complete as per direction of the Engineer-in-Charge.
55Supplying of armed plastic chair for DTW Scheme
56Wall Colouring,lettering,picture and drawing etc.
57Supplying of wooden table with a drawer to the right side of size 48” X 30” X 30” for DTW Scheme Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56738370
AUTHORITY Government Departments
TENDER VALUE 3.79 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Running Maintenance Of Pipelines Of Various Existing Piped Water Supply (Pws) Schemes At East Noabadi, Herbang, Wakhinagar, And Dinabandhunagar Under Pwd (Dws), Mandwi Rd Block, Within The Jurisdiction Of Pwd (Dws) Sub-Division, Mandwi.Sh:Maintenance Of Pipelines And Other Allied Works Of Existing Piped Water Supply (Pws) Schemes During The Year 2026-27.Gp-1
Basic Detail
Tender No 40/DNIeT/EE/DWS/JRN/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 29 Jul 2026
Submission Date 06 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 3.79 Lakhs
Tender Fee 1000
EMD 7583
Exemption Not Available
Document List
15b1e389-d4d7-410a-aaac-10d49a07648f.html
BOQ_76409.xls
SBD40PLMtcmndi.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

15b1e389-d4d7-410a-aaac-10d49a07648f.html

xls

BOQ_76409.xls

pdf

SBD40PLMtcmndi.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender