Tender For Procurement And Installation Of Cctv, Nurse Calling System, Access Control, Fire Pump, Swimming Pool Filtration System In Ayush Hospital At Pati, Dnh.
Tender Value
1.58 Crore
Estimated cost
Bid Submission
06 Aug 2026
6 days left
EMD
3.18 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dadra and Nagar Haveli → Dadra and Nagar Haveli
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Procurement And Installation Of Cctv, Nurse Calling System, Access Control, Fire Pump, Swimming Pool Filtration System In Ayush Hospital At Pati, Dnh.
BOQ
| Sl. No. | Item Description |
| 1 | CCTVHoneywell Impact I−HIPD5PI−MF 5 MP IP IR Dome Camera |
| 2 | Honeywell Impact I-HIPB5PI-MF 5 MP IP IR Bullet Camera |
| 3 | Honeywell NVR Impact I-HPNVR-864 64ch 8 Sata 640mbps |
| 4 | D-Link 16 Port Gigabit PoE Switch - 16 PoE+ 2 SFP Ports 250m DGS-F1018P-E |
| 5 | D-Link 24 Port Gigabit DGS-F1026P-E 24GE PoE + 2 SFP Ports 250m PoE Switch |
| 6 | HDD Surveillance 16TB WD Enterprise (For 60 Days Recording) |
| 7 | 12U Fan Pdu full tray |
| 8 | 4U Fan Pdu full tray |
| 9 | Birla 4Core Fiber Cable |
| 10 | LIU Small Box |
| 11 | SFP Module LC Duplex |
| 12 | Fiber patch code Lc-Lc duplex sm 2mtr |
| 13 | Lc pigtails sm 1mtr |
| 14 | 24 port liu LC loaded |
| 15 | 5x5 Heavy box |
| 16 | D-link rj45 connector |
| 17 | Fiber Splicing per core |
| 18 | Camera installation and configuration charges |
| 19 | S/I Nextview 43inch 4K ultra Google TV |
| 20 | Nurse calling systemSupply, Installation, Testing & Commissioning of 24 Line central display Unit. |
| 21 | Supply, Installation, Testing & Commissioning of Bed Side Unit without Voice. |
| 22 | Supply, Installation, Testing & Commissioning of Pull Cord Unit. |
| 23 | Supply, Installation, Testing & Commissioning of Door Display Unit. |
| 24 | Software |
| 25 | Access control solutionsSITC of Client PC with Intel i7 processor with 16GB RAM , 4GB NVDIA graphics card and 1TB minimum HDD |
| 26 | SITC of Access control Licenses of Time attendance, Access Control for up to 200 Users. |
| 27 | Providing & erecting approved make Fingerprint and card based Premium Door Controller with LCD and Keypad having following features.(A) Optical Fingerprint and Card based Reader (Card personality Module not included](B) Dot-Matrix LCD and Touch sense Keypad(C) Built-In interfaces like door lock, door sense, exit Reader, Exit switch, Ethernet RS485, Aux Input & Aux Output Port(D) 5000 Events, Access Control, Time Attendance, Tamper Detection(E) 4 LEDS and Buzzer |
| 28 | Providing & erecting approved make Card Personality Module (CPM) having following features(A) EM proximity Card Reader Module [Low frequency](B) Compatible with any COSEC Door Controllers and COSEC Reader CA(C) Supports EM Proximity Card |
| 29 | Supply, Installation, Testing & Commissioning of Exit Switch with Metal Finish. |
| 30 | Supply, Installation, Termination & Commissioning of EM Magnetic Lock 600 LBS with Door Sense, Mounting Clamp. |
| 31 | Supply Installation Testing & Commissioning of EM Prox Card without Printing |
| 32 | Supply of XLPE insulated FRLS cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 8/10/12 core ISI marked with copper stranded/solid conductor. |
| 33 | Swimming Pool: SITC of Jacuzzi equipment 1.spa jet massage nozzles 32/50mm. (air/water). Make: Aquafine 2.Air controller 32mm dia. Make: Aquafine 3.Circulation pumps. Make: Aquafine 4.ABS flange grate & seal Make: BWT/PROCOPI 5.2'' ASTM double union valve (for above massage pumps) Make: Cepex 6. 3\\" ASTM double union valve (for above massage pumps) Make: Cepex 7. control panel with necessary controls for pumps with ELCb & MCCB 8. Design, SITC, Technical supervision, Transportation etc. |
| 34 | SITC of Filtration system of swimming pool 1. Filter - Bobbin wound sand filter 960 mm dia with side mount 6 way multiport valve max flow rate of 31cum/hr. Maximum working pressure 2.5 bar, 2'' connection.Make: Aquafine make in India 2. Filter media (Silica sand) 50kg bags 16/32 grade. 3. Pump: PROCOPI S.A (France): Filtration pump with pre filter. Pump body is made from polypropylen. 2.54 Kw/3 phase. Inlet 2' and outlet 2'. Flowrate 29m3/hr. Model: BWT infinity 300T Item code: 125575510 (2 duty+ 1 stand by) 4(a). Salt Chlorinator: Procopi/BWT (France): salt chlorination system - BWT electrolyser PRO A22 saltchlorinator for pools upto 100m3, selection of chlorine productionlevel via LCD code: 125254493. 4(b). 63 mm PVC double union valve. Make cepex 5(a). Pool basin fittings: Main drain: Square main draingrille & frame only 300x300 mm in SS30445m3/hr Make:Aquafine make in India 5(b). Vacuum point: PROCOPI S.A (France): Vacuum point in white ABS with 50mm connection, model RB 312 Item code: 42660000 5(c). Floor Inlet: Bottom inlet (floor inlet), white ABS plastic bottom inlet nozzle for concrete with SS screws of capacity 9000LPH. Material of construction ABS plastics. Make: Aquafine make in India 6(a). Underwater light: SS 316 surface mounted LED light 9 W (3*3W) with SS fixing bracket, 12V DC, 2700K 1mtr cable 6(b). LED drive for above lights 6(c). LED drive for protection 7(a). Maintenance Equipments:PROCOPI SA: (france: concrete metal vacuum head 35cm, Item code: 862100 7(b). PROCOPI SA: (france): floating hose 250 Item code: 867000 7(c). supply of reinforced aluminium telescopic handle9.6 m long with clip connection. Make: Aquafine make in India 7(d). PROCOPI SA. (France): luxury deep leaf rake made in polypropelene and aluminium frame. Item code: 874800 7(e). PROCOPI SA (france): luxury surface hand skimmer with aluminium frame. Item code. 874400 7(f). PROCOPI SA (france): curved brushes made in poypropelene and with aluminium reinforcement 45 cms for pool basins. Item code: 875400 7(g). PROCOPI SA. (france): Test kit for chlorine and PH. Item code: 885200 8.ControlPanel: Control Panel wall mounting dust tight and vermin proof fabricated out of 16/18 SWG CRCA sheet chemically treated and powder coated of siemens grey with ELCB, MCB, DOL starter, illuminated on/off push button with elements. 9. 63 mm PVC double union valve make: cepex 10. 63 mm 3 piece union adaptor 11. 63mm brass NRV 12. start up chemicals 13. Design, supply, Installation, Technical supervision etc 14. Testing & Commissioning 15. As built drawing and O & M manual |
| 35 | FIRE FIGHTING PUMPS & EQUIPMENTS : The pumps shall be single stage/multistage designed for continuous operation and shall have a continuously rising head characteristic without any zone of instability. Pumps (excluding the jockey pump) shall be able to operate sequentially. The head vs. capacity, input power vs. capacity characteristics, etc. shall match to ensure load sharing and trouble free operation throughout the range. In case of accidental reverse flow through the pump the driver shall be capable of bringing the pump to its rated speed in the normal direction from the point of maximum possible reverse speed. The Pump with motor, base plate, coupling device and coupling guard shall be coupled at the works of the manufacturer. The motor shall have a 15% margin of power rating over the rated pump input power. The pumps shall be capable of delivering a minimum of 150 percent of rated capacity at a total head of not less than 65% of the total rated head. The total shut-off head shall not exceed 120 percent of total rated head on the pump. The pump shall be tested at the factory and test curve shall be submitted showing the performance and horse power requirement based on this test before final acceptance. Contractor shall provide necessary test certificates, type test certificates, technical data sheets performance curves and NPSH curves of the pumps, dimension detail, foundation detail from the manufacturer while submitting data sheet for approval. Pumps coupled with motor or engine on a common platform shall perform smoothly without any excessive noise or vibration. Each pump shall be provided with a plate giving, in the case of centrifugal pumps, the delivery head, capacity and the number of revolutions per minute, and in the case of reciprocating pumps, the diameter of the steam cylinders and water plungers and the length of the stroke, as also the ratios of the effective aggregate areas of the suction and the delivery valves to the area of the water plungers. Make : Kirloskar / Libi / CI Electric driven Hydrant/Sprinkler Pump suitable for automatic operation consisting of the following: Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump. Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. Make : Kirloskar / Libi / CI Common bed plate of fabricated mild steel channel or cast iron type. Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. (Client's Scope). The pump shall be of the following specifications: Discharge - 2850 lpm Head - 120 m No. of stage preferred - Single Speed RPM - 2900 |
| 36 | Electric driven Jockey Pump suitable for automatic operation consisting of the following: Horizontally mounted centrifugal end suction pump complete with mechanical seal and including necessary arrangement for testing of pump. Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. Common bed plate of fabricated mild steel channel or cast iron type. Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. (Client's Scope) Make : Kirloskar / Libi / CI The pump shall be of the following specifications: Discharge - 180 lpm Head - 110 m No. of stage preferred - Single stage Speed RPM - 2900 |
| 37 | Diesel engine standby Pump suitable for automatic operation consisting of the following: Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump Water coolled Diesel Engine developing suitable BHP at 1850 RPM for the Pump, common bed plate for mounting of engine and pump, (Others scope) and vibration damping arrangement by Cushy Foot and engine panel provided by engine manufacturer, connection to Engine Starting Panel as per item (4), sealed maintenance free batteries. Rate shall include Exhaust pipe of required length with asbestos lagging with aluminum cladding, muffler, day oil tank with first charge. Make : Kirloskar / Libi / CI Flexible coupling and coupling guard with the Pump, Common bed plate of fabricated mild steel channel or cast iron type. Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. (Cleint's Scope) ; Engine panel; Sealed maintenance free batteries. Day oil tank with first charge; The pump shall be of the following specifications: Discharge - 2850 lpm ; Head - 120 m ; No. of stage preferred - Single ; Speed RPM - 1850 |
| 38 | Air vessel for fire pumps as per following specifications: Air vessel shall be fabricated from MS plate conforming to IS:2002 grade 2A having 8mm thickness shell with 10 mm thick dished ends and suitable supporting legs. It shall be provided with a 80 mm dia flanged connections from pump, one 25 mm drain and Air Release Valve with ball valve and 15 mm sockets for pressure gauge and pressure switches. The air vessel shall be hydraulically tested to 20 kg/cm2 pressure for 30 minutes. Diameter - 450mm; Shell thickness - 8mm; Dish ends - 10mm; Height - 1500mm; Material of Construction - M.S.; Test Pressure - 20 Kg./sq.cm. |
| 39 | COMMON PUMP CONTROL PANEL : SITC of fire control panel metal clad type suitable for 415 V AC three phase 4 wire 50Hz supply system. The panel shall be suitable for automatic operation of the fire pumps as per the specified parameters. The panel shall be completely compartmentalised and complete with relays, contactors, starters, Copper Bus Bars, designation labels as per requirement, continuous earth bar, panel separators, protective screens, cable clamping support system, top/bottom cable gland plates for incoming and out going cable entries as per details given below: INCOMING: 630A 35KA TPN MCCB with rotary handles - 1 No. BUSBARS: A set of 800A 415V 50Hz 3 Ph 4 wire copper busbars. INSTRUMENTS FOR INCOMER: A set of instrumentation with a set of Current transformer 600/5A with Ammeter 0-600A, Selector Switch, Voltmeter 0-500V with selector switch and a set of phase-RYB indicating lights with MCB and energy meter. Provision for BMS connectivity. The panel should have sufficient no. of potential free contacts for connectivity with Building Management System for monitoring purposes; INSTRUMENTS ON OUTGOINGS : A set of instrumentation with ammeter with selector switch andcurrent transformer each pump. Indication lights for ON-OFF indication for each fire pump; OUTGOING FEEDERS: For Hydrant Pump 200A TP 35KA MCCB with rotary handle, 120HP star-delta starter, overload relay, single phase preventer, timer etc. - 1No.; For Sprinkler Pump ; 200A TP 35KA MCCB with rotary handle, 120HP star-delta starter, overload relay, single phase preventer, timer etc. - 1No.; For Jockey Pump; 63A TP 25KA MCCB with rotary handle, 20 HP DOL starter, overload relay, single phase preventer, timer etc. - 1 No. : For Diesel engine operated pump : AMF logic control for auto starting of the diesel engine operated pump when the electric driven pumps fail to start. The control cubicle shall consist of MCBs, 12/24V battery charger, DC ammeter and voltmeters , indicating lights , push buttons, hooter, lockout timers, interlocking relay, fuel level indicators etc. as required. Control wiring, auxiliary switches and timer for automatic starting and stopping of Jockey and electric driven pump with externally mounted pressure switches. The control wiring shall be done in such a way that the Jockey pump shall start when the pressure falls to 7.0 Kg/sq.cm and stops at 8.0 Kg/sq.cm pressure and Main fire pump shall start when the pressure drops below 6.5 Kg/sq.cm. and stops when the pressure builds above 8.0 Kg/sq.cm. Jockey pump shall stop when the main pump is working. Suitable timers shall be used for starting and stoping of the pumps operation. |
| 40 | Supplying, installation, setting, testing and commissioning of differential type pressure switches with one NO+ 1 NC contact 220 volts 5 amp and pressure rating 0-35 Kg//sq.cm for operation of fire pumps. Indfoss / Danfoss Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender