Housing Urban and Rular Development Government Departments Closing in 10 days TDR #56737485

Tender For Electrical Installation Work Including Supply Installation Testing and Commissioning of Ac Machine At Proposed Vip Control Room Within The Premises Of Dtc, Barasat In North 24 Parganas District.

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Aug 2026
10 days left
EMD
2714
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Installation Work Including Supply Installation Testing and Commissioning of Ac Machine At Proposed Vip Control Room Within The Premises Of Dtc, Barasat In North 24 Parganas District.

BOQ

Name of Work:- Electrical installation work including SITC of AC machine at proposed VIP control room within the premises of DTC, Barasat in North 24 Parganas district.
Sl. No. Item Description
1Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Kabel / Polycab / Finolex/ Havells/ Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x 100mm x 65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.
2Average run 8 mtr
3Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Kabel / Polycab / Finolex/ Havells/ Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite / Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish.
4On Board
5Supplying & Fixing CRC sheet metal (16 SWG) JB-cum-Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite / Perspex coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
6240 mm x 200 mm x 65 mm
7Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Make- Anchor) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite /perspex cover and making necessary connections as required.
8Supply & Fixing 240 V, 2 nos. 6A plug socket with separate 2 nos. 6A Piano key type switch (Make- Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required.
9Supply & Fixing 240 V, 1 no. 6A, & 1 no. 20A plug socket with separate 1 no. 6A & 1 no. 20A Piano key type switch (Make- Anchor) on sheet metal switch board embedded in wall incl. S & F 200x150x65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
10Supply & Fixing 240 V, 25 A, Modular type AC starter (Make- North West/ Legrand/ Crabtree/L&T) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
11Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make- North West/ Legrand/ Crabtree/L&T), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
12Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
1320 mm size
14Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- RR Kabel / Polycab / Finolex/ Havells/ Gloster) of the following sizes in the prelaid polythene pipe/PVC rigid conduit as per GS.
153 x (1.5 sqmm)
162 x (2.5 sqmm) + 1 x (1.5 sqmm)
172 x (4 sqmm) + 1 x (2.5 sqmm)
182 x (6 sqmm) + 1 x (4 sqmm)
19Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
20a) 1.5 sq mm
21b) 2.5 sq mm
22c) 4 sq mm
23d) 6 sq mm
24Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make- Legrand/L&T/Schneider/ABB]
252+10 Way
26Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS. [Make- Legrand/L&T/Schneider/ABB]
2740 A DP
28Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per GS. [Make- Legrand/L&T/Schneider/ABB]
296-32 SP
30Dismantling of the existing old damaged unusable electrical installtaion incl. electrical wiring, fittings-fixtures, DB boxes & other materials by Co's own tools & tackels and shifting the same to site store as per direction of EIC.
31Supplying & fixing medium gauge GI Pipe (ISI- Medium) Protection with necessary fittings and jointing metarials as required.
3240 mm dia
33Supply & fixing of 230V, 50Hz, 24 hrs. Digital Time Switch (Make- L&T GIC, Crono 67DDTO) in existing SS enclosure for controlling of street light fitting as per direction of EIC.
34S & F of 250V 1-phase Timer DB (equivalent to 2+10 way SPNDB in size) on wall with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25A DPMCB (C-curve 10kA) and 1 no. 24 hr. Digital time switch (L&T, Crono 67DDTO) and 1 no. 22/25A 2 Pole power Contactor (L&T, MNX- 22 - 2P or MU-25 2P) complete with internal wiring with suitable size of PVC insulated copper wire with socketting and 2 nos. Connector including 1 no. Toggle switch for auto/manual operation and 1 no. LED indicator lamp and necessary earthing attachment as per direction of EIC. [Make: L&T/ABB/Legrand]
35Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
36Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
37Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, frequency 50/60 Hz, Operating temp range 0 deg to 40 deg C, internal surge protection of 2.5 KV (internal) with Short & Open circuit protection, THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K / 6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted.(System lumen efficacy ≥115 lm/Watt) [Make- Philips(signify)/Crompton/Wipro/Havells/Magik or Brand approved by EIC]
38Twin fittings along with S/F of 2 nos. 18-20 W LED lamps as per specification
39Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting
40Supply & Fixing Socket type fan regulator (Step type) (Make- Anchor) on existing sheet metal switchboard with bakelite / perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
41Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
42Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, Speed : 320 rpm (minimum), A.C. Ceiling Fan and class of insulation : B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum Air delivery : 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut-bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Make - Crompton Greaves/ Usha /Orient / Havells or Brand approved by EIC]
43Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
44Supplying, Installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.System lumen efficacy shall be as below : System lumen efficacy ≥135 lm/Watt [Make- Philips(signify)/ Crompton /Wipro / Havells / Magik or Brand approved by EIC]
4545 Watt
46Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below : By ISI-Medium GI pipe.
47Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
48Excavation of soil for installation of Earth Electrode and filling & ramming for Soft Soil.
49Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS.
50Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
51Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid GI wire
52No. 6 SWG
53Supply, Installation, Testing and Commissioning of air-cooled Hi-Wall Split type Air Conditioner of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/ concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification and air circulation functions conforming to IS-1391 (Part- II) with all amendments and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.(Make- Mitubishi Electric/O-General/Daikin/Blue Star/Carrier/Hitachi or brand approved by EIC)
54Cooling Capacity - 6.1 kW (Minimum), Air Flow Rate : 800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star (min)
55Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF/RAC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines all accessories as per specifications etc. as required :
566.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
5715.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
58S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines.
59i) 2.5 sqmm, 3/4 core copper cable (FRLS type make : Polycab /Finolex /RR Kabel / Havells)
60Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56737485
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 10-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Installation Work Including Supply Installation Testing and Commissioning of Ac Machine At Proposed Vip Control Room Within The Premises Of Dtc, Barasat In North 24 Parganas District.
Basic Detail
Tender No 32/T of 26-27 of AE/BESD
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 29 Jul 2026
Submission Date 10 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 2714
Exemption Not Available
Document List
1c8cecc4-d53a-4e33-af7e-8d3a227ee208.html
2911.pdf
BOQ_5087865.xls
Tendernotice_1 (16).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

1c8cecc4-d53a-4e33-af7e-8d3a227ee208.html

pdf

2911.pdf

xls

BOQ_5087865.xls

pdf

Tendernotice_1 (16).pdf