Tender For Provn Of 01 X Living Shelter For 20 Men At Mtn Art Bde Camp And Provn Of Drainage In Bathroom For Ors At Fd Regt (Parbat Ali) Of Age B/R And Age E/M Under Ge Tenga
Tender Value
34.90 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
3 days left
EMD
69800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kameng → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of 01 X Living Shelter For 20 Men At Mtn Art Bde Camp And Provn Of Drainage In Bathroom For Ors At Fd Regt (Parbat Ali) Of Age B/R And Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n,exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in hard/dense soil all as specified and directed by Engr-in-Charge. |
| 2 | M&L PCC 1:2:4 type B2(using 40mm graded aggregate)as in suface channel and drain etc all as specified and directed by Engr-in-Charge. |
| 3 | Returning/filling in including spreading, levelling, watering and well remming in hard/dense soil . |
| 4 | Removing excavated material n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point. |
| 5 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for providing PCC (1:3:6) type C1 using (20mm graded crush stone aggregate) as in copings including necessary formwork complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for rendering 15 mm in CM (1:6) over concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for MS TMT bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 10 | M&L for providing pre-cast RCC (1:2:4) type B1 using (20mm graded crush stone aggregate) as in cover slabs of manholes and similar location including necessary formwork and set in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 11 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil. |
| 12 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard /dense soil |
| 13 | M&L PCC 1:4:8 type D2(using 40mm graded aggregate)as in foundation filling and mass concrete etc complete all as specified and directed. |
| 14 | M&L for PCC 1:2:4 type B-2 using (40 mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 15 | M&L for rendering 15 mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L for rendering 10 mm in CM (1:6) over concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 17 | M&L for newly plastered surfaces of walls and applying two coats of cement based paint, over a coat of primer complete all as specified and directed. |
| 18 | M&L for Preparing new plastered surfaces of wall and applying Two coats of acrylic distemper/ distemper oil emulsion (OBD), over a coat of 3mm thick wall care putty all as specified including preperation of surfaces complete all as specified and directed. |
| 19 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 20 | M & L for applying two coat of synthetic enamel paint over a coat of red oxide primer to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of new steel surfaces complete all as specified and directed. |
| 21 | S&F Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 22 | S&F Pre-Painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having testile strenght of 550 Mpa as in roof ridge fixed with self tapping screws as specified and directed. |
| 23 | M&L hard core of gauge n.exc 63mm, deposited, spread and levelled in layers nexc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 24 | M & L 100 mm thick Cement concrete type B2,1:2:4 (40mm graded aggregate) as in sub base, including form work complete as as specified and directed by Engineer-in-Charge |
| 25 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed. |
| 26 | M&L for Virified Ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 27 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 28 | S & F 2nd class hard wood plain framed panelled shutter 35mm thick (any number of panels) with panels of timber flat on both sides, feather edged or of veneered particle board medium density, wood particle board with commercial face veneer complete all as specified and directed. |
| 29 | S & F 30mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc but divided into squares, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads etc for securing glass etc sizes of members of shutters as specified in SSR Part I Section 8, Clause 8.24(a) supplied and fitted to chowkhats complete all as specified and directed. |
| 30 | S&F MS window guard bars, window frames etc articles confirming to Fe 410-0 or Fe 310-0. |
| 31 | M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 32 | S&F 100mm size stainless steel butt hinges, medium weight, cold rolled complete with stainless steel screw etc. all as specified as directed. |
| 33 | S & F 75mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 34 | S& F Aluminium anodised barrel tower bolts 150mm long of extruded section and fixed |
| 35 | S& F Aluminium anodised barrel tower bolts 100mm long of extruded section and fixed |
| 36 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised |
| 37 | S & F 100mm size extruded aluminium alloy handles, fabricated type anodised |
| 38 | S & F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed. |
| 39 | S&F sheet glass 3mm thick ordinary quality and glazing with oil putty in squares n exc 0.50 Sqm in each pane complete all as specified and directed. |
| 40 | M&L for 75 mm thick plain cement concrete type C-1, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement complete all as specified and directed. |
| 41 | Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 42 | All as per item No. 41 here in before One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 43 | All as per item No. 41 here in before but for one 3 pin socket outlet 5 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 44 | All as per item No. 41 here in before but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified and directed. |
| 45 | S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type |
| 46 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type |
| 47 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed. |
| 48 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 49 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. |
| 50 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 51 | Supply and fixing LED light fitting 1 x10W bulkhead luminaires inculding LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as directed. |
| 52 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbers clamps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed. |
| 53 | Supply and fix sheet metal enclosures for DBs double door when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 54 | S&F MCB SPN having braking capacity 10KA, 32 Amps, 'C' curve, 240 V complete all as specified and directed. |
| 55 | S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 'C' curve, 240 V complete all as specified and directed. |
| 56 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 57 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 16 Sqmm 2 core complete all as specified and directed. |
| 58 | S & F incl leakage testing galvanised steel water tubing medium grade 40 mm dia bore with all fittings such as bends, elbow, socket, reducer,clamps etc, laid under floor / trenches all as specified & directed. |
| 59 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out complete all as specified and as directed. |
| 60 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 61 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection laid flat ie length of cable cover shall be laid across the cable all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender