Tender For Repair, Maintenance & Replacment Of Apfc Panel, Distribution Panel, Mccb, Change Over Switch, Earthing And Other Connected Electrical Works At Pal Ur Mil Stn Under Ge Pal Ur.

Issued by Statutory Bodies & Commissions/Committees · Kangra, Himachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Aug 2026
17 days left
EMD
36000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair, Maintenance & Replacment Of Apfc Panel, Distribution Panel, Mccb, Change Over Switch, Earthing And Other Connected Electrical Works At Pal Ur Mil Stn Under Ge Pal Ur.

BOQ

Name of Work:- Repair, Maintenance & Replacment of APFC Panel, Distribution Panel, MCCB, Change over switch, Earthing and other connected electrical works At Pal ur Mil Stn under GE Pal ur.
Sl. No. Item Description
1Excavation in trenches in any type of soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting cut complete all as specified and directed.
2All as per item No 1 above but in hard/dence/PCC/Floor/road complete all as specified and directed.
3Returning, filling in including spreading, levelling,wstering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested, poles,stays,struts hane been erected and tested complete all as specified and directed.
4Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
5M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.
6M&L for laying in trenches burnt brick sub class 'B' for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified and directed.
7Taking out from trenches / floors/ road/ wall/ pipe/pole LT cable of any size/description and removing from site incl making good the disturbed surfaces to match with existing surface complete all as specified and directed.
8Supply & laying of LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 95 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. Note: (i) Cable joint shall be measured and paid separately.)
9All as per item No. 8 above but of cross sectional area 70 Sqmm, 3.5 core complete all as specified and directed.
10All as per item No. 8 above but of cross sectional area 50 Sqmm, 3.5 core complete all as specified and directed.
11All as per item No. 8 above but of cross sectional area 35 Sqmm, 3.5 core complete all as specified and directed.
12All as per item No. 8 above but of cross sectional area 25 Sqmm, 3.5 core complete all as specified and directed.
13M&L for Cable route indicator showing \\"LT Cable\\" and rout of cable with arrow made of CI in suitable elptical/round shape and each fixed on angle iron 40x40x6mm, 800mm long painted in Blue Colour with two coats of synthetic enamel paint cover a coat of red oxide primer duly embaded in PCC block (0.40x0.40x0.40)mtr including in ground and 0.15mtr above ground lable complete all as specified and directed.
14Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ / 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete all as specified and directed.
15Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ / 4 core XLPE armoured Al conductor cable of size 70 to 95 sq mm complete all as specified and directed.
16M&L for laying GI PIPE light grade 50mm dia for cable potection in road/floor complete all as specified and directed.
17M&L for laying GI Pipe light grade 80mm dia for cable potection in road/floor.
18Material and labour for removal green vegetation and dressing around the sub stn panels / structure / plinth/ hardstanding up to 1.5 mtr etc including disposal of vegitation /material up to 50 mtr distance from the site and levelling/surfacing the ground complete all as specified and directed.
19Demolition of concrete (coping of steel /PCC pole/Road) of any description and in any position complete all as specified and directed.
20M&L for Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles,earth pit ,including provision of necessary form work, finishing even and smooth without using extra cement complete all as specified and directed.
21M & L Plain Cement Concrete 1:3:6 type C2 using 40mm graded stone aggregate as in road cutting filling, foundation, fencing post , struts etc. complete all as specified and directed.
22S&F MCCB Enclosure for frame optium alongwith MCCB, 3 pole 100 Amp complete all as specified and directed.
23Supply and fixing in replacement of MCCB 400 Amp rating,4-pole 415V, 50 Hz breaking capacity 36 KA, Adjustable & fixed magnetic setting type complete all as specified and directed.
24Supply and fixing in replacement of MCCB 250 Amp rating,4-pole 415V, 50 Hz breaking capacity 36 KA, Adjustable & fixed magnetic setting type complete all as specified and directed.
25Supply and fixing in replacement of MCCB 200 Amp rating,4-pole 415V, 50 Hz breaking capacity 25 KA, Adjustable & fixed magnetic setting type complete all as specified and directed.
26Supply and fixing in replacement of MCCB 125 Amp rating,4-pole 415V, 50 Hz breaking capacity 16 KA, Adjustable & fixed magnetic setting type complete all as specified and directed.
27Supply and fixing in replacement of MCCB 160 Amp rating,4-pole 415V, 50 Hz breaking capacity 25 KA, Adjustable & fixed magnetic setting type complete all as specified and directed.
28Earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete all as specified and directed. (Note: GI strip & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid separately.)
29All as per item Srl No. 28 above but by using GI wire 4mm dia as earth lead & 15mm bore medium grade GI pipe for protection of earth wire from plate to main switch board complete all as specified and directed.
30M&L for provn of Earthing complete with Copper earth plate electrode 600 x 600 x 3 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.50 M below normal GL, connected to copper earth strip 25 x 3.15 mm upto 7.5 mtr protection pipe by means of copper bolts, nuts, check nuts & washers incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No.3 of SSR Pt-I specification. Note :- (i) The excess requirement (if more than 7.5 Mtr) of copper strip, GI protection pipe 40 mm dia and their joints for connecting upto the test point will be measured and paid separately) (ii) The excavation exceeds if any of the above will be deemed to be included in the item rate.
31Supply, install, testing & commissioning of CPRI approved LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire , 50 Hz , AC supply system having busbar chamber with Aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of sie 40X40X6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:- (a) MCCB 250 A, 4P, 415 Volts AC supply , thermal magnetic release type 36 KA-01 No (b) MCCB 100A, 4P, 415 Volt 10 KA thermal magnetic relase type -02 Nos. (c) MCCB 63A, 4P, 415 Volt 10 KA thermal magnetic relase type -01 Nos. (d) Timelite -110 A 3 Pole, 230 V Digital time switch Make : Indoasian 01 Nos (e) On load change over switch 250Amp inbuilt with panel -01 Nos (f) Panel mounted multi function meter for measuring Voltage (0-500 Volts), Current (0- 100 Amps) and frequency-01 No (g) RYB neon indicating lamp panel mounting type (Set of three ) - 01 No (h) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses (j) Cable entries gland and two no earthing terminal
32Supply and fixing automatic power factor controller relay 8 Steps as per Cat Part No RG-8T complete all as specified and directed
33Supply and fixing automatic power factor controller relay 12 Steps as per Cat Part No RG-12T complete all as specified and directed
34Supply and fixing automatic power factor contactor 73 Amp 3 pole 415 volt, 37 KW,AC3 as per existing Cat Part No complete all as specified and directed.
35Supply and fixing automatic power factor contactor 50 Amp 3 pole 415 volt ,22 KW,AC3 as per existing Cat Part No No complete all as specified and directed.
36Supply and fixing automatic power factor contactor 40 Amp 3 pole 415 Volt ,18.5 KW,AC3 as per existing Cat Part No No complete all as specified and directed.
37Supply and fixing automatic power factor contactor 25 Amp 3 pole 415 volt ,11 KW,AC3 as per existing Cat Part No No complete all as specified and directed.
38Supply and fixing Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 30 KVAR complete all as specified and directed.
39Supply and fixing Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 20 KVAR complete all as specified and directed.
40Supply and fixing Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 15 KVAR complete all as specified and directed.
41Supply and fixing Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 10 KVAR complete all as specified and directed.
42Supply and fixing Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 5 KVAR complete all as specified and directed.
43Supply and fixing copper bus bar chamber suitable for 100 Amp TPN with 4 outgoing ways , IP-42 complete all as specified and directed.
44Supply and fixing in replacement of synthetic insulated mat suitable for 1100 volts grade (ISI Marked) of size 2mx1mx10mm complete all as specified and directed.
45S&F of cable gland of size 25 to 50 Sqmm for cable entry complete all as specified and directed.
46S&F of cable gland of size 70 to 95 Sqmm for cable entry complete all as specified and directed.
47M&L for painting for sheet metal enclosure of LT panels/Installation boards with two coats of synthetic enamel paint as directed colour after scraping of old paint & preparation of surface and applying a coat of red oxide primer complete all as specified and directed.
48Supply and fixing in replacement voltmeter for LT panel Square dial of size 96x96mm digital type complete all as specified and as directed. (Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work).
49Supply and fixing in replacement Ammeter for LT panel Square dial of size 100 mm digital type complete all as specified and as directed. (Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work).
50Supply and fixing in replacement indicator lamp assembly in red,yellow & blue colour for LT panels complete all as specified and directed.
51Supply and fixing 4 pole off load change over switch 200 Amp alongwith connected accessories complete all as specified and directed.
52Supply and fixing 4 pole off load change over switch 100 Amp alongwith connected accessories complete all as specified and directed.
53Supply and fixing 4 pole off load change over switch 250 Amp alongwith connected accessories complete all as specified and directed.
54Supply and fixing Double Wall Corrugated (DWC) pipe of size 63mm outer dia and 50mm inner dia confirming to IS:14930 Part- II including necessary pipe fittings such as couplers, end caps, bend etc. including fixed to wall/roof /pole/trench as required with suitable clamps for cable protection complete all as specified and directed.
55M&L for repair to APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, contactors ,relays and capacitor of loose parts/electrical wiring, complete testing of APFC relay with necessary settings with CTs /load adjustments to match with the APFC load management system complete with replacement of burnt/worn out unserviceable components /burnt wires thimbles /lugs etc for APFC panel capcity 50 KVAR to 150 KVAR complete all as specified and directed. Note : All unserviceable parts shall be measured and paid seprately .
56Supply and fixing in replacement of Auxiliary contractor 1 NO+1NC TP 415 volts suitable for 10 KVAR rating for existing APFC panel complete all as specified and directed.
57Supply and fixing in replacement of Auxiliary contractor 1 NO+1NC TP 415 volts suitable for 20 KVAR rating for existing APFC panel complete all as specified and directed.
58Supply and fixing in replacement of CT's suitable for Ampere meter 100/5A ratio for existing APFC panel complete all as specified and directed.
59Supply and fixing in replacement of CT's suitable for Ampere meter 200/5A ratio for existing APFC panel complete all as specified and directed.
60S&F glow sign boards made out of acraylic sheet 2 mm thick fitted on front side of the box and GI sheet 24 SWG for making installation mounted on a 25x25x4mm angle iron frame including tube light fitting of suitable size prewired complete with stranded accessories size of board is 150cmx0.60cmx0.15cm duly written in bold capital letters of size as suitable for sign board (Font as explained and approved by engineer in charge ) including necessary cable connection for supply to board complete all as specified and directed. (Note Sign board and name which to be written on board shall got approved from the engineer in charge before execution.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56736796
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair, Maintenance & Replacment Of Apfc Panel, Distribution Panel, Mccb, Change Over Switch, Earthing And Other Connected Electrical Works At Pal Ur Mil Stn Under Ge Pal Ur.
Basic Detail
Tender No GEP-56/2026-27
Bidding Type Tender
Location
City Kangra
State Himachal Pradesh
Key Dates
Publish Date 29 Jul 2026
Submission Date 19 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 36000
Exemption Not Available
Document List
92ef35a7-0a75-4574-8632-2aebf93f8827.html
BOQ_875517.xls
td.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.