Tender For Provn To Extend Existing Roof Area Of Four Pole Hydraulic Jack, Provn Of Reinforced Cement Concrete Jali And Provn Antenna Obstruction Light At Sdr Tower At Af Stn Bikaner Under Ge (Af) Nal
Tender Overview
Project Description
Tender for Provn To Extend Existing Roof Area Of Four Pole Hydraulic Jack, Provn Of Reinforced Cement Concrete Jali And Provn Antenna Obstruction Light At Sdr Tower At Af Stn Bikaner Under Ge (Af) Nal
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in post holes(or similar holes)each n exc 0.5 cum ,getting out soft or loose soil ,returning ,filling in and ramming earth or broken rubble mixed with earth around ,in layers not exceeding 25 cm complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8 type D2 (40mm graded aggregate)as in foundation filling and mass concrete complete all as specified and directed. |
| 3 | M&L for MS work in roof trusses (framed), trussed, purlins, crane gantries, rails, posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. including special shaped washer etc. complete and including all necessary drilling or cutting holes in brick/ concrete surfaces and making good, welding work, bolting or reveting etc and similar work conforming to Fe-290 Gde E-165 complete and all as specified |
| 4 | S & F Framed work as in Steel Gate of angle or other section with gusset plate, rails, braces, stair case etc Fe 410-W (Gde-E-250) quality 'A' complete drilled for fixing of steel including welding etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, locking arrangement, gate closer, stopper etc and hanging also fastening and fixing and building upto 8 mtr complete all as specified and directed. |
| 5 | Supply and fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenght of 550Mpa as in roof covering / clading to wall, fixed with self tapping screws as per existing shed profile complete all as specified and directed. |
| 6 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 7 | Material & Labour for 150 mm thick cement concrete type D-2,1:4:8 (40mm graded stone aggt) as in sub base concrete all as specified and directed. |
| 8 | M&L for 40 mm thick Sand filling under floors or in foundation including consolidation complete all as specified and directed. |
| 9 | M&L for 60 mm Machine pressed precast interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thick ness , M-35 grade with grey cement and pigment fixed with cement complete all as specified and directed. |
| 10 | Supply and Fixing pre cast cement concrete jallies, 35 mm thick, type B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) including wire fabric set and jointed in cement mortar 1:4, design and pattern as approved by Engineer - in- charge, and complete all as specified and directed . |
| 11 | M&L for brick work with sub class \\"B\\" brick burnt clay straight or curved on plan exc 6 m mean radius and built in cement mortar 1 : 6 . complete all as specified & directed. |
| 12 | M&L for rendering 15 mm thick on wall (brick or concrete surfaces) in cement mortar 1:4 and surface finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | M&L for Preparation of newly plastered or unplastered surfaces of walls and applying two coats of exterior acrylic emulsion in any pattern (approved by GE), paint over and including a coat of exterior primer complete all as specified and directed. |
| 14 | M&L for Preparation of newly plastered or unplastered surfaces of walls and applying two coats of exterior acrylic emulsion in any pattern (approved by GE), paint over and including a coat of exterior primer complete all as specified and directed. |
| 15 | M&L for 3mm thick wall care putty on wall complete all as specified and directed. |
| 16 | Excavation in soft/loose soil in trenches not exceeding 1.5 metre wide / manholes area n exc 10sqm on plan and depth not exceeding 1.5 metre and getting out complete all as specified and directed. |
| 17 | Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. |
| 18 | Removing excavated material to a distance exc. 50 metre but not exceeding 100 metre and depositing where directed at a level not exceeding 1.5 Metre above starting point, complete all as specified and directed. |
| 19 | M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in sides of rounded or chamfered on edges of brick work complete all as specified and directed by Engr -in-charge. |
| 20 | Supply and fix Low intensity twin aviation obstruction warning light, 230 V, AC, High flow LED based, Red colour, IP 65 as per IS/IEC 60529:2001, Non Flashing, Pre-cast Aluminum Housing, Polycarbonate dome glass for 360 degree illumination, high quality transparent polycarbonate diffuser complete all as specified and as directed by Engineer -in-Charge. Note : Rate quoted by the contractor deemed to be including for the followings:-(i) The light will be fixed at antena tower having height of not less than 25mtr. (ii) Contractor should follow all safety measure to install the light at tower. (iii) All tools and plants required will be provided by contractor. |
| 21 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge Note : Rate quoted by the contractor deemed to be incl for the followings:-(i) The cable will be fixed at antena tower having height of not less than 25mtr. (ii) Contractor should follow all safety measure to install the light at tower. (iii) All tools and plants required will be provided by contractor. |
| 22 | M&L sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. |
| 23 | Material and labour for fixing of new un-reinforced pre-cast concrete cable covers, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed. M&L for disconnecting from the existing location cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking out existing cable of any size. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender