Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #56736794

Tender For Repair And Maintenance Of Ci/Gi/Di Pipe Line, Pumping Set, Sluice/ Foot Valve, Nrv Valve Chamber, Lt Control Panel Etc Incl Cleaning Of Oh Tank And Ug Sump In Ncat, Tech Area, Residential Area And Bhingar Pump House At Vrde Ahmednagar.

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
40 Lakhs
Estimated cost
Bid Submission
26 Aug 2026
1 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Ci/Gi/Di Pipe Line, Pumping Set, Sluice/ Foot Valve, Nrv Valve Chamber, Lt Control Panel Etc Incl Cleaning Of Oh Tank And Ug Sump In Ncat, Tech Area, Residential Area And Bhingar Pump House At Vrde Ahmednagar.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 19-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-Aug-2026

BOQ

Name of Work:- REPAIR AND MAINT OF CI/GI/DI PIPE LINE, PUMPING SET, SLUICE/ FOOT VALVE, NRV VALVE CHAMBER, LT CONTROL PANEL ETC INCL CLEANING OF OH TANK AND UG SUMP IN NCAT, TECH AREA, RESIDENTIAL AREA AND BHINGAR PUMP HOUSE AT VRDE AHMEDNAGAR.
Sl. No. Item Description
1Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying GI/DI/CI pipe and getting out trimming the sides, forming bottom surface to required level in soft/loose soil complete all as specified and as directed.
2Returning, filling in , including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick after laying and testing of cable/pipes complete all as specified and as directed.
3Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
4Supply and fix in replacement gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipes including taking down the existing unserviceable one of following sizes complete all as specified and directed.(a) 20 mm dia.
5(b) 25 mm dia.
6(c) 40 mm dia.
7(d) 50 mm dia
8Taking down the steel tubing and connections in trenches, wall / floor including cleaning for refixing or removal to store for pipe line of following bore. complete all as specified and directed. (a) 15 mm to 40 mm nominal bore
9(b) Above 40 mm nominal bore
10Supply and laying steel tubes, galvanised,\\"medium \\" grade, including necessary GI fitting such as elbows, bends, Tees , Unions, nipples etc, laid in trenches fixed on wall/floor/ceiling and refilling complete with fixing accessories such as clamps, hooks etc , complete all as specified and directed for following size:-(a) 15 mm bore pipe
11(b) 20 mm dia pipe
12(c) 25 mm dia pipe
13(d) 40 mm dia pipe
14(e) 50 mm dia pipe
15(f) 80 mm dia pipe
16(g) 100 mm dia pipe.
17Supply and laying High density polyethylene pipes (HDPE) 75 -100mm bore pipe of pressure rating 6 kgf/cm2 , including necessary fittings such as elbows, bends, Tees , Unions, nipples etc, laid in trenches fixed on wall/floor/ceiling complete with fixing accessories such as clamps, hooks etc , complete all as specified and directed.
18Laying only in trenches/wall/floor, in old or new position, old GI pipes obtained from item No-04.00 after necessory cleaning internally and externally both, returning the old screw threads and replacement of all old fittings with new of size of pipe 15mm. complete all as specified and directed.
19All as per above item but of size 20 mm dia.
20All as per item herein above but of size 25 mm dia.
21All as per item herein above but of size 40 mm dia.
22All as per item herein above but of size 50 mm dia.
23All as per item herein above but of size 80 mm dia.
24All as per item herein above but of size 100 mm dia.
25Taking up and down CI / DI water mains including all fittings lead / tyton joints, buring out of joints and recovering lead for the following bore sizes of pipes complete all as specified and directed. Note:- Earth work /excavation for taking out pipe lines shall be measured and paid separately under relevant items. (a) 200 mm dia
26(b)150 mm dia
27(c) 100 mm dia
28M & L for ductile iron pipes type K-9, 100 mm dia with spigot and socket ends centrifugally cast in any lenth laid in trenches complete all as specified and directed.
29M & L for 150 mm dia ductile iron pipes Type K-9 with spigot and socket ends centrifugally cast in any length laid in trenches complete all as specified and directed.
30M & L for ductile iron pipes type K-9, 200 mm dia with spigot and socket ends centrifugally cast in any lenth laid in trenches complete all as specified and directed.
31Providing and laying in position cement concrete of 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level
32Taking out sluice valves refacing, regrinding and refixing for following diameters of pipe line. complete all as specified and directed.a) 200 mm dia
33b) 150 mm dia
34c) 100 mm dia
35d) 80 mm dia
36M&L for run lead joint in position of size 200 mm CI/DI pipes by burning out existing joints,recovering lead, cleaning internal surfaces of socket and providing new joints with using recovered lead and additional new lead,and new spurnyarn making joint leak proof. complete all as specified and directed.
37All as per item herein above but Size of CI/DI pipe 100mm.
38Supply and fix in replacement sluice valve both ends flanged, ISI marked with CI body, heavy duty, high pressure with CI wheel and stainless steel spindle of class PN 1.6 complete including rubber gasket and suitable size ms bolts, nuts and washers complete all as specified and directed of following sizes: (a) 80 mm dia pipe.
39(b) 100 mm dia pipe
40(c) 150 mm dia pipe
41(d) 200 mm dia pipe
42Supplying, fixing, jointing and testing cast iron double acting air release valve heavy duty ISI marked with iron wheel and stainless steel spindle conforming to latest IS with flanged ends complete all as specified and directed for the following sizes:-a) 80mm bore
43b) 100mm bore
44Material and labour for providing and fixing flanged joints, including nuts, bolts and gaskets of the following sizes, complete with testing of joints. complete all as specified and directed.(a) 80 mm dia pipe
45(b) 100 mm dia pipe
46(c) 150 mm dia pipe
47(d) 200 mm dia pipe
48M&L for lead wool joint in position of size 200 mm CI/DI pipes by providing new additional lead wool complete all as specified and directed.
49M&L for lead wool joint in position of size 150 mm CI/DI pipes by providing new additional lead wool complete all as specified and directed.
50M&L for lead wool joint in position of size 100 mm CI/DI pipes by providing new additional lead wool complete all as specified and directed.
51M&L for lead wool joint in position of size 80 mm CI/DI pipes by providing new additional lead wool complete all as specified and directed.
52Supply and fix in replacement Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of following size complete all as specified and directed.(a) 25 mm dia
53(b) 20 mm dia
54Providing and laying S&S C.I. /D.I. standard specials upto 200mm dia such as tees, bends,collars, tapers, caps etc complete all as specified and directed.
55Providing and laying flanged C.I./D.I. standard specials upto 200 mm dia such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing complete all as specified and directed.
56Cutting existing road black top surfaces of required width and depth for laying of pipe line, refilling and making good after laying of pipe with removed soil and finally sealed with cement concrete of thickness not less than 100 mm to match with the top surface of Road.(Cement concrete shall be measured and paid seperately under appropriate item) complete all as specified and directed.
57Supply and fixing (in repair ) mechanical joint made out of MS sheet fabricated as per existing site requirement including long MS nuts bolts rubber gasket cutting of pipe of any size GI/CI/MS/AC/DI pipe complete all as specified and directed. of following sizes:-(a) 200 mm bore
58(b) 100 mm bore
59(c) 80 mm bore Please Enable Macros to View BoQ information
60(c) 80 mm bore Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56736794
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 26-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Ci/Gi/Di Pipe Line, Pumping Set, Sluice/ Foot Valve, Nrv Valve Chamber, Lt Control Panel Etc Incl Cleaning Of Oh Tank And Ug Sump In Ncat, Tech Area, Residential Area And Bhingar Pump House At Vrde Ahmednagar.
Basic Detail
Tender No GE I R AND D GNR TOKEN 36 OF 2026-27(8024)
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 19 Aug 2026
Submission Date 26 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
34312e0b-638e-47d6-81dd-2153d5ab2c4f.html
BOQ_875358.xls
TENDERDOCUMENTS.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Aug 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

34312e0b-638e-47d6-81dd-2153d5ab2c4f.html

xls

BOQ_875358.xls

pdf

TENDERDOCUMENTS.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender